Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Improved measurements of the TeV-PeV extragalactic neutrino spectrum from joint analyses of IceCube tracks and cascades

The IceCube South Pole Neutrino Observatory has discovered the presence of a diffuse astrophysical neutrino flux at energies of TeV and beyond using neutrino induced muon tracks and cascade events from neutrino interactions. Here, we present two analyses sensitive to neutrino events in the energy range 1 TeV to 10 PeV, using more than 10 years of IceCube data. Both analyses consistently reject a neutrino spectrum following a single power-law with a significance of > 4⁢𝜎 in favor of a broken power law. We describe the methods implemented in the two analyses, the spectral constraints obtained, and the validation of the robustness of the results. Additionally, we report the detection of a muon neutrino in the medium energy starting events sample, or MESE, with an energy of 11.4$^{+2.46}_{−2.53}$ PeV, the highest energy neutrino observed by IceCube to date. The results presented here show insights into the spectral shape of astrophysical neutrinos, which has important implications for inferring their production processes in a multimessenger picture.

astroparticles↗

Electromagnetic modeling and science reach of DMRadio-m 3

DMRadio-m 3 is an experimental search for dark matter axions. It uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. DMRadio-m 3 is designed to be sensitive to Kim-Shifman-Vainshtein-Zakharov (KSVZ) and Dine-Fischler-Srednicki-Zhitnisky (DFSZ) QCD axion models in the 10–200 MHz (41 neV/𝑐 2 –0.83 μ⁢eV/𝑐 2 ) range, and to axions with 𝑔 𝑎⁢𝛾⁢𝛾 =𝑔 𝑎⁢𝛾⁢𝛾,DFSZ ⁡(30 MHz) =1.87 ×10 −17 GeV −1 over 5–30 MHz as an extended goal. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m 3 , which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of 2 larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a 3⁢𝜎 live scan time of 2.9 years.

Dark matter direct detection↗

Searches for Light Dark Matter and Evidence of Coherent Elastic Neutrino-Nucleus Scattering of Solar Neutrinos with the LUX-ZEPLIN (LZ) Experiment

We present searches for light dark matter (DM) with masses 3–9 GeV/𝑐 2 in the presence of coherent elastic neutrino-nucleus scattering (CE⁢𝜈⁢NS) from 8 B solar neutrinos with the LUX-ZEPLIN experiment. This analysis uses a 5.7 tonne-yr exposure with data collected between March 2023 and April 2025. In an energy range spanning 1–6 keV, we report no significant excess of events attributable to dark matter nuclear recoils, but we observe a significant signal from 8 B CE ⁢𝜈 ⁢NS interactions that is consistent with expectation. We set world-leading limits on spin-independent and spin-dependent-neutron DM-nucleon interactions for masses down to 5 GeV/𝑐 2 . In the no-dark-matter scenario, we observe a signal consistent with 8 B CE⁢ 𝜈 ⁢NS events, corresponding to a 4.5⁢𝜎 statistical significance. This is the most significant evidence of 8 B CE 𝜈 ⁢NS interactions and is enabled by robust background modeling and mitigation techniques. This demonstrates LZ’s ability to detect rare signals at keV-scale energies.

Dark matter detectors↗

Microcavities coupled to multilevel atoms

A three-level atom in the {Lambda} configuration coupled to a microcavity is studied. The two transitions of the atom are assumed to couple to different counterpropagating mode pairs in the cavity. We analyze the dynamics both in the strong-coupling and the bad-cavity limits. We find that, compared to a two-level setup, the third atomic state and the additional control field modes crucially modify the system dynamics and enable more advanced control schemes. All results are explained using appropriate dressed-state and eigenmode representations. As potential applications, we discuss optical switching and turnstile operations and detection of particles close to the resonator surface.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coulomb excitation of radioactive {sup 21}Na and its stable mirror {sup 21}Ne

The low-energy structures of the mirror nuclei {sup 21}Ne and radioactive {sup 21}Na have been examined by using Coulomb excitation at the TRIUMF-ISAC radioactive ion beam facility. Beams of {approx}5x10{sup 6} ions/s were accelerated to 1.7 MeV/A and Coulomb excited in a 0.5 mg/cm{sup 2} {sup nat}Ti target. Scattered beam and target particles were detected by the segmented Si detector BAMBINO, while {gamma} rays were observed by using two TIGRESS HPGe clover detectors perpendicular to the beam axis. For each isobar, Coulomb excitation from the (3/2){sup +} ground state to the first excited (5/2){sup +} state was observed and B(E2) values were determined by using the 2{sup +}{yields}0{sup +} de-excitation in {sup 48}Ti as a reference. The {phi} segmentation of BAMBINO was used to deduce tentative assignments for the signs of the mixing ratios between the E2 and M1 components of the transitions. The resulting B(E2){up_arrow} values are 131{+-}9 e{sup 2} fm{sup 4} (25.4{+-}1.7 W.u.) for {sup 21}Ne and 205{+-}14 e{sup 2} fm{sup 4} (39.7{+-}2.7 W.u.) for {sup 21}Na. The fit to the present data and the known lifetimes determined E2/M1 mixing ratios and B(M1){down_arrow} values of {delta}=(-)0.0767{+-}0.0027 and 0.1274{+-}0.0025 {mu}{sub N}{sup 2} and {delta}=(+)0.0832{+-}0.0028 and 0.1513{+-}0.0017 {mu}{sub N}{sup 2} for {sup 21}Ne and {sup 21}Na, respectively (with Krane and Steffen sign convention). By using the effective charges e{sub p}=1.5e and e{sub n}=0.5e, the B(E2) values produced by the p-sd shell model are 30.7 and 36.4 W.u. for {sup 21}Ne and {sup 21}Na, respectively. This analysis resolves a significant discrepancy between a previous experimental result for {sup 21}Na and shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coulomb excitation of the proton-dripline nucleus {sup 20}Na

The low-energy structure of the proton dripline nucleus {sup 20}Na has been studied using Coulomb excitation at the TRIUMF-ISAC radioactive ion beam facility. A 1.7-MeV/nucleon {sup 20}Na beam of {approx}5x10{sup 6} ions/s was Coulomb excited by a 0.5-mg/cm{sup 2nat}Ti target. Scattered beam and target particles were detected by the BAMBINO segmented Si detector while {gamma} rays were detected by two TIGRESS HPGe clover detectors set perpendicular to the beam axis. Coulomb excitation from the 2{sup +} ground state to the first excited 3{sup +} and 4{sup +} states was observed, and B({lambda}L) values were determined using the 2{sup +}{yields}0{sup +} de-excitation in {sup 48}Ti as a reference. The resulting B({lambda}L){down_arrow} values are B(E2;3{sup +}{yields}2{sup +})=55{+-}6 e{sup 2} fm{sup 4} (17.0{+-}1.9 W.u.), B(E2;4{sup +}{yields}2{sup +})=35.7{+-}5.7 e{sup 2} fm{sup 4} (11.1{+-}1.8 W.u.), and B(M1;4{sup +}{yields}3{sup +})=0.154{+-}0.030 {mu}{sub N}{sup 2} (0.086{+-}0.017 W.u.). These measurements provide the first experimental determination of B({lambda}L) values for this proton dripline nucleus of astrophysical interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin differences in the Zr 90 compound nucleus induced by ( p , p ' ) , ( p , d ) , and ( p , t ) surrogate reactions

Here, the effect of the production mechanism on the decay of a compound nucleus is investigated. The nucleus 90 Zr was produced by three different reactions, namely 90 Zr (p,p') 90 Zr, 91 Zr (p,d) 90 Zr, and 92 Zr (p,t) 90 Zr , which served as surrogate reactions for 89 Zr (n,γ). The spin-parity (J π ) distributions of the states populated by these reactions were studied to investigate the surrogate reaction approach, which aims at indirectly determining cross sections for compound-nuclear reactions involving unstable targets such as 89 Zr. Discrete γ rays, associated with transitions in 90 Zr and 89 Zr, were measured in coincidence with light ions for scattering angles of 25°–60° and 90 Zr excitation energies extending above the neutron separation energy. The measured transition systematics were used to gain insights into the J π distributions of 90 Zr. The 90 Zr (p,p') reaction was found to produce fewer γ rays associated with transitions involving high spin states (J = 6–8 ℏ) than the other two reactions, suggesting that inelastic scattering preferentially populates states in 90 Zr that have lower spins than those populated in the transfer reactions investigated. The γ-ray production was also observed to vary by factors of 2–3 with the angle at which the outgoing particle was detected. These findings are relevant to the application of the surrogate reaction approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the astrophysical diffuse neutrino flux using starting track events in IceCube

In this article, a measurement of the diffuse astrophysical neutrino spectrum is presented using IceCube data collected from 2011-2022 (10.3 years). We developed novel detection techniques to search for events with a contained vertex and exiting track induced by muon neutrinos undergoing a charged-current interaction. Searching for these starting track events allows us to not only more effectively reject atmospheric muons but also atmospheric neutrino backgrounds in the southern sky, opening a new window to the sub-100 TeV astrophysical neutrino sky. The event selection is constructed using a dynamic starting track veto and machine learning algorithms. We use this data to measure the astrophysical diffuse flux as a single power law flux (SPL) with a best-fit spectral index of γ=2.58$_{-0.09}^{+0.10}$ and per-flavor normalization of $\phi$$_{per-flavor}^{Astro}$=1.68$_{-0.22}^{+0.19}$×10 -18 ×GeV -1 cm -2 s -1 sr -1 (at 100 TeV). The sensitive energy range for this dataset is 3-550 TeV under the SPL assumption. This data was also used to measure the flux under a broken power law, however we did not find any evidence of a low energy cutoff.

79 ASTRONOMY AND ASTROPHYSICS↗

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS↗

Direct detection of dark baryons naturally suppressed by ℋ-parity

We identify symmetries in a broad class of vectorlike confining dark sectors that forbid the leading electromagnetic moments that would ordinarily mediate dark baryon scattering with the Standard Model. The absence of these operators implies dark baryon dark matter has much smaller cross sections for elastic scattering off nuclei, leading to suppressed direct detection signals. In the confined description, we identify an “ℋ-parity” symmetry that exists in any dark sector with dark quarks transforming under a vectorlike representation of a new confining SU(𝑁 𝑐 ) gauge theory as well as a vectorlike representation of the electroweak group SU⁡(2) 𝐿 . The parity is independent of 𝑁 𝑐 and 𝑁 𝑓 , though it is essential that the dark quarks are neutral under hypercharge. This parity forbids dark hadron electric and magnetic dipole moments, charge radius, and anapole moment, while permitting dimension-7 operators that include polarizability, electroweak loop-induced interactions, and lower-dimensional electromagnetic transition moments between different neutral dark baryon states. We work out an explicit example, 𝑁 𝑐 = 𝑁 𝑓 = 3, that is the most minimal theory with fermionic dark baryons. In this specific model, we use the nonrelativistic quark model to show the magnetic dipole moment and charge radius vanish, while the transition moments are nonzero, consistent with ℋ-parity. We discuss the implications of a suppressed direct detection signal, emphasizing that this broad class of models provide a well-motivated target for future colliders.

composite models↗

Detecting H{yields}hh in the mirror model at the CERN Large Hadron Collider

The Higgs sector may play an important role in detecting mirror particles, which can be the candidates of dark matter and appear as missing energy in the detectors at the LHC. In this paper we worked out the Higgs boson spectrum and the Higgs couplings for the symmetric vacuum, namely v{sub 1}=v{sub 2}=v, in the mirror model, and investigated the constraints from electroweak precision observables. Our study showed that electroweak precision observables have already constrained the Higgs boson sector severely. We then explored the Higgs boson phenomenology, and focused on the scenario that the heavier Higgs boson H can decay into a pair of lighter Higgs bosons h. We proposed to study the invisible decay of the Higgs boson via the pair production of them, in which one Higgs boson decays into bottom quarks and the other decays invisibly. Our detail simulation for signals and backgrounds showed that the observation of the signal can reach 5{sigma} significance for m{sub H}=260 GeV and m{sub h}=115 GeV with 10 fb{sup -1} integrated luminosity at the LHC. Moreover the possible method to further suppress dominant Zbb background was discussed. We also simulated the signals and backgrounds for H{yields}hh{yields}4b. Our results showed that it is very difficult to isolate the signals from huge QCD continuum backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino signals from annihilating/decaying dark matter in the light of recent measurements of cosmic ray electron/positron fluxes

The excess of cosmic ray electron and positron fluxes measured by the PAMELA satellite and ATIC balloon experiments may be interpreted as the signals of the dark matter annihilation or decay into leptons. In this paper, we show that the dark matter annihilation/decay which reproduces the electron/positron excess may yield a significant amount of high-energy neutrinos from the Galactic center. In that case, future kilometer-square size experiments may confirm such a scenario, or even the Super-Kamiokande results already put constraints on some dark matter models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ionization-based search for magnetic monopoles using the NOvA Far Detector

We report a search for highly ionizing magnetic monopoles in the cosmic-ray flux using a 2713-day dataset collected during 2015–2025 with the NOvA Far Detector, a 14-kt segmented detector located on Earth’s surface in Minnesota, United States. The search is sensitive to monopoles across a wide range of speeds, 7 × 10 −4 < 𝛽 < 0.995, and is sensitive to masses as low as 2 × 10 5 GeV for the fastest monopoles. No signal was observed. With the detector’s large surface area and minimal overburden, we achieve the strongest flux limits reported to date in several regions of speed and mass. For heavy monopoles with masses above 10 13 GeV that are able to reach the detector from above or—crossing Earth—from below, we find a flux limit 𝜙 90% < 2 × 10 −16 cm −2 s −1 sr −1 (90% confidence level) for monopoles with 0.005 < 𝛽 < 0.8. Across the same range of speeds, we report a limit 𝜙 90% < 8 × 10 −16 cm −2 s −1 sr −1 for light monopoles with masses above 10 8 GeV that can reach the detector from above.

magnetic monopoles↗

A novel digital pulse processing architecture for nuclear instrumentation

The field of nuclear instrumentation covers a wide range of applications, including counting, spectrometry, pulse shape discrimination and multi-channel coincidence. These applications are the topic of many researches, new algorithms and implementations are constantly proposed thanks to advances in digital signal processing. However, these improvements are not yet implemented in instrumentation devices. This is especially true for neutron-gamma discrimination applications which traditionally use charge comparison method while literature proposes other algorithms based on frequency domain or wavelet theory which show better performances. Another example is pileups which are generally rejected while pileup correction algorithms also exist. These processes are traditionally performed offline due to two issues. The first is the Poissonian characteristic of the signal, composed of random arrival pulses which requires to current architectures to work in data flow. The second is the real-time requirement, which implies losing pulses when the pulse rate is too high. Despite the possibility of treating the pulses independently from each other, current architectures paralyze the acquisition of the signal during the processing of a pulse. This loss is called dead-time. These two issues have led current architectures to use dedicated solutions based on re-configurable components like Field Programmable Gate Arrays (FPGAs) to overcome the need of performance necessary to deal with dead-time. However, dedicated hardware algorithm implementations on re-configurable technologies are complex and time-consuming. For all these reasons, a programmable Digital pulse Processing (DPP) architecture in a high level language such as Cor C++ which can reduce dead-time would be worthwhile for nuclear instrumentation. This would reduce prototyping and test duration by reducing the level of hardware expertise to implement new algorithms. However, today's programmable solutions do not meet the need of performance to operate online and not allow scaling with the increase in the number of measurement channel. That is why an innovative DPP architecture is proposed in this paper. This architecture is able to overcome dead-time while being programmable and is flexible with the number of measurement channel. Proposed architecture is based on an innovative execution model for pulse processing applications which can be summarized as follow. The signal is not composed of pulses only, consequently, pulses processing does not have to operate on the entire signal. Therefore, the first step of our proposal is pulse extraction by the use of dedicated components named pulse extractors. The triggering step can be achieved after the analog-to-digital conversion without any signal shaping or filtering stages. Pileup detection and accurate pulse time stamping are done at this stage. Any application downstream this step can work on adaptive variable-sized array of samples simplifying pulse processing methods. Then, once the data flow is broken, it is possible to distribute pulses on Functional Units (FUs) which perform processing. As the date of each pulse is known, they can be processed individually out-of-order to provide the results. To manage the pulses distribution, a scheduler and an interconnection network are used. pulses are distributed on the first FU which is not busy without congesting the interconnection network. For this reason, the process duration does not result anymore in dead-time if there are enough FUs. FUs are designed to be standalone and to comprises at least a programmable general purpose processor (ARM, Microblaze) allowing the implementation of complex algorithms without any modification of the hardware. An acquisition chain is composed of a succession of algorithms which lead to organize our FUs as a software macro-pipeline, A simple approach consists in assigning one algorithm per FU. Consequently, the global latency becomes the worst latency of algorithms execution on FU. Moreover, as algorithms are executed locally - i.e. on a FU - this approach limits shared memory requirement. To handle multichannel, we propose FUs sharing, this approach maximize the chance to find a non-busy FU to process an incoming pulse. This is possible since each channel receive random event independently, the pulse extractors associated to them do not necessarily need to access simultaneously to all Computing resources at the same time to distribute their pulses. The major contribution of this paper is the proposition of an execution model and its associated hardware programmable architecture for digital pulse processing that can handle multiple acquisition channels while maintaining the scalability thanks to the use of shared resources. This execution model and associated architecture are validated by simulation of a cycle accurate architecture SystemC model. Proposed architecture shows promising results in terms of scalability while maintaining zero dead-time. This work also permit the sizing of hardware resources requirement required for a predefined set of applications. Future work will focus on the interconnection network and a scheduling policy that can exploit the variable-length of pulses. Then, the hardware implementation of this architecture will be performed and tested for a representative set of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a double-sided silicon strip detector autoradiography system

Purpose: The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study. Methods: Detector background counts were determined by measuring a nonradioactive sample slide for 52 h. Energy spectra and detection efficiency were measured for seven commonly used radionuclides under representative conditions for tissue imaging. System dead time was measured by imaging {sup 18}F samples of at least 5 kBq and studying the changes in count rate over time. A line source of {sup 58}Co was manufactured by irradiating a 10 μm nickel wire with fast neutrons in a research reactor. Samples of this wire were imaged in both the DSSD and storage phosphor screen systems and the full width at half maximum (FWHM) measured for the line profiles. Multiradionuclide imaging was employed in a two animal study to examine the intratumoral distribution of a {sup 125}I-labeled monoclonal antibody and a {sup 131}I-labeled engineered fragment (diabody) injected in the same mouse, both targeting carcinoembryonic antigen. Results: Detector background was 1.81 × 10{sup −6} counts per second per 50 × 50 μm pixel. Energy spectra and detection efficiency were successfully measured for seven radionuclides. The system dead time was measured to be 59 μs, and FWHM for a {sup 58}Co line source was 154 ± 14 μm for the DSSD system and 343 ± 15 μm for the storage phosphor system. Separation of the contributions from {sup 125}I and {sup 131}I was performed on autoradiography images of tumor sections. Conclusions: This study has shown that a DSSD system can be beneficially applied for digital autoradiography with simultaneous multiradionuclide imaging capability. The system has a low background signal, ability to image both low and high activity samples, and a good energy resolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A scintillator-based approach to monitor secondary neutron production during proton therapy

Here, the primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. As a result, an experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors’ analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. In conclusion, the authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗