Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Cumulative annoyance due to multiple aircraft flyover with differing peak noise levels

A laboratory study in which 160 subjects judged the annoyance of 30 minute sessions of aircraft noise is described. Each session contained nine flyovers consisting of various combinations of three takeoff recordings of Boeing 727. The subjects were asked to judge their annoyance in the simulated living room environment of the laboratory and also to assess how annoyed they would be if they heard the noise in their home during the day, evening, and night periods. The standard deviation of the sound level did not improve the predictive ability of L sub eq (equivalent continuous sound level) which performed as well or better than other noise measured. Differences were found between the projected home responses for the day, evening, and nighttime periods. Time of day penalties derived from these results showed reasonable agreement with those currently used in community noise indices.

Shepherd, K. P.↗

Effects of chemical equilibrium on turbine engine performance for various fuels and combustor temperatures

A study was performed to quantify the differences in turbine engine performance with and without the chemical dissociation effects for various fuel types over a range of combustor temperatures. Both turbojet and turbofan engines were studied with hydrocarbon fuels and cryogenic, nonhydrocarbon fuels. Results of the study indicate that accuracy of engine performance decreases when nonhydrocarbon fuels are used, especially at high temperatures where chemical dissociation becomes more significant. For instance, the deviation in net thrust for liquid hydrogen fuel can become as high as 20 percent at 4160 R. This study reveals that computer central processing unit (CPU) time increases significantly when dissociation effects are included in the cycle analysis.

Tran, Donald H.↗

MISSE 2 PEACE Polymers Experiment Atomic Oxygen Erosion Yield Error Analysis

Atomic oxygen erosion of polymers in low Earth orbit (LEO) poses a serious threat to spacecraft performance and durability. To address this, 40 different polymer samples and a sample of pyrolytic graphite, collectively called the PEACE (Polymer Erosion and Contamination Experiment) Polymers, were exposed to the LEO space environment on the exterior of the International Space Station (ISS) for nearly 4 years as part of the Materials International Space Station Experiment 1 & 2 (MISSE 1 & 2). The purpose of the PEACE Polymers experiment was to obtain accurate mass loss measurements in space to combine with ground measurements in order to accurately calculate the atomic oxygen erosion yields of a wide variety of polymeric materials exposed to the LEO space environment for a long period of time. Error calculations were performed in order to determine the accuracy of the mass measurements and therefore of the erosion yield values. The standard deviation, or error, of each factor was incorporated into the fractional uncertainty of the erosion yield for each of three different situations, depending on the post-flight weighing procedure. The resulting error calculations showed the erosion yield values to be very accurate, with an average error of 3.30 percent.

McCarthy, Catherine E.↗

Toward Unified Satellite Climatology of Aerosol Properties. 3. MODIS Versus MISR Versus AERONET

We use the full duration of collocated pixel-level MODIS-Terra and MISR aerosol optical thickness (AOT) retrievals and level 2 cloud-screened quality-assured AERONET measurements to evaluate the likely individual MODIS and MISR retrieval accuracies globally over oceans and land. We show that the use of quality-assured MODIS AOTs as opposed to the use of all MODIS AOTs has little effect on the resulting accuracy. The MODIS and MISR relative standard deviations (RSTDs) with respect to AERONET are remarkably stable over the entire measurement record and reveal nearly identical overall AOT performances of MODIS and MISR over the entire suite of AERONET sites. This result is used to evaluate the likely pixel-level MODIS and MISR performances on the global basis with respect to the (unknown) actual AOTs. For this purpose, we use only fully compatible MISR and MODIS aerosol pixels. We conclude that the likely RSTDs for this subset of MODIS and MISR AOTs are 73% over land and 30% over oceans. The average RSTDs for the combined [AOT(MODIS)+AOT(MISR)]/2 pixel-level product are close to 66% and 27%, respectively, which allows us to recommend this simple blend as a better alternative to the original MODIS and MISR data. These accuracy estimates still do not represent the totality of MISR and quality-assured MODIS pixel-level AOTs since an unaccounted for and potentially significant source of errors is imperfect cloud screening. Furthermore, many collocated pixels for which one of the datasets reports a retrieval, whereas the other one does not may also be problematic.

Mishchenko, Michael I.↗

Calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug

The results of an experimental calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug (MFP) are presented and compared to a previously obtained calibration of a 15 in. Mass-Flow Plug. An ASME low-beta, long-radius nozzle was used as the calibration reference. The discharge coefficient for the ASME nozzle was obtained by numerically simulating the flow through the nozzle from the WIND-US code. The results showed agreement between the 15 and 16 in. MFPs for area ratios (MFP to pipe area ratio) greater than 0.6 but deviate at area ratios below this value for reasons that are not fully understood. A general uncertainty analysis was also performed and indicates that large uncertainties in the calibration are present for low MFP area ratios.

Davis, David O.↗

Calibration of the NASA GRC 16 In. Mass-Flow Plug

The results of an experimental calibration of the NASA Glenn Research Center 16 in. Mass-Flow Plug (MFP) are presented and compared to a previously obtained calibration of a 15 in. Mass-Flow Plug. An ASME low-beta, long-radius nozzle was used as the calibration reference. The discharge coefficient for the ASME nozzle was obtained by numerically simulating the flow through the nozzle from the WIND-US code. The results showed agreement between the 15 in. and 16 in. MFPs for area ratios (MFP to pipe area ratio) greater than 0.6 but deviate at area ratios below this value for reasons that are not fully understood. A general uncertainty analysis was also performed and indicates that large uncertainties in the calibration are present for low MFP area ratios.

Davis, David O.↗

Measuring Atmospheric CO2 Enhancements from the 2017 British Columbia 1 Wildfires Using a Lidar

During the summer 2017 ASCENDS/ABoVE airborne science campaign, the NASA Goddard CO2 Sounder lidar overflew smoke plumes from wildfires in the British Columbia, Canada. In the flight path over Vancouver Island on 8 August 2017, the column XCO2 retrievals from the lidar measurements at flight altitudes around 9 km showed an average enhancement of 4 ppm from the wildfires. A comparison of these enhancements with those from the Goddard Global Chemistry Transport model suggested that the modeled CO2 emissions from wildfires were underestimated by more than a factor of 2. A spiral-down validation performed at Moses Lake airport, Washington showed a bias of 0.1 ppm relative to in situ measurements and a standard deviation of 1 ppm in lidar XCO2 retrievals. The results show that future airborne campaigns and spaceborne missions with this type of lidar can improve estimates of CO2 emissions from wildfires and estimates of carbon fluxes globally.

Jianping Mao↗

Global Intercomparison of hyper-resolution ECOSTRESS coastal sea surface temperature measurements from the Space Station with VIIRS-N20

The ECOSTRESS multi-channel thermal radiometer on the Space Station has an unprecedented spatial resolution of 70 m and a return time of hours to 5 days. It resolves details of oceanographic features not detectable in imagery from MODIS or VIIRS, and has open-ocean coverage, unlike Landsat. We calibrated two years of ECOSTRESS sea surface temperature observations with L2 data from VIIRS-N20 (2019–2020) worldwide but especially focused on important upwelling systems currently undergoing climate change forcing. Unlike operational SST products from VIIRS-N20, the ECOSTRESS surface temperature algorithm does not use a regression approach to determine temperature, but solves a set of simultaneous equations based on first principles for both surface temperature and emissivity. We compared ECOSTRESS ocean temperatures to well-calibrated clear sky satellite measurements from VIIRS-N20. Data comparisons were constrained to those within 90 min of one another using co-located clear sky VIIRS and ECOSTRESS pixels. ECOSTRESS ocean temperatures have a consistent 1.01 ◦C negative bias relative to VIIRS-N20, although deviation in brightness temperatures within the 10.49 and 12.01 µm bands were much smaller. As an alternative, we compared the performance of NOAA, NASA, and U.S. Navy operational split-window SST regression algorithms taking into consideration the statistical limitations imposed by intrinsic SST spatial autocorrelation and applying corrections on brightness temperatures. We conclude that standard bias-correction methods using already validated and well-known algorithms can be applied to ECOSTRESS SST data, yielding highly accurate products of ultra-high spatial resolution for studies of biological and physical oceanography in a time when these are needed to properly evaluate regional and even local impacts of climate change.

Nicolas Weidberg↗

Evaluation of cloud fraction and its radiative effect simulated by IPCC AR4 global models against ARM surface observations

Cloud Fraction (CF) is the dominant modulator of radiative fluxes. In this study, we evaluate CF simulations in the IPCC AR4 GCMs against ARM ground measurements, with a focus on the vertical structure, total amount of cloud and its effect on cloud shortwave transmissivity, for both inter-model deviation and model-measurement discrepancy. Our intercomparisons of three CF or sky-cover related dataset reveal that the relative differences are usually less than 10% (5%) for multi-year monthly (annual) mean values, while daily differences are quite significant. The results also show that the model-observation and the inter-model deviations have a similar magnitude for the total CF (TCF) and the normalized cloud effect, and they are twice as large as the surface downward solar radiation and cloud transmissivity. This implies that the other cloud properties, such as cloud optical depth and height, have a similar magnitude of disparity to TCF among the GCMs, and suggests that a better agreement among the GCMs in solar radiative fluxes could be the result of compensating errors in either cloud vertical structure, cloud optical depth or cloud fraction. Similar deviation pattern between inter-model and model-measurement suggests that the climate models tend to generate larger bias against observations for those variables with larger inter-model deviation. The simulated TCF from IPCC AR4 GCMs are very scattered through all seasons over three ARM sites: Southern Great Plains (SGP), Manus, Papua New Guinea and North Slope of Alaska (NSA). The GCMs perform better at SGP than at Manus and NSA in simulating the seasonal variation and probability distribution of TCF; however, the TCF in these models is remarkably underpredicted and cloud transmissivity is less susceptible to the change of TCF than the observed at SGP. Much larger inter-model deviation and model bias are found over NSA than the other sites in estimating the TCF, cloud transmissivity and cloud-radiation interaction, suggesting that the Arctic region continues to challenge cloud simulations in climate models. Most of the GCMs tend to underpredict CF and fail to capture the seasonal variation of CF at middle and low levels in the tropics. The high altitude CF is much larger in the GCMs than the observation and the inter-model variability of CF also reaches maximum at high levels in the tropics. Most of the GCMs tend to underpredict CF by 50-150% relative to the measurement average at low and middle levels over SGP. While the GCMs generally capture the maximum CF in the boundary layer and vertical variability, the inter-model deviation is largest near surface over the Arctic. The internal variability of CF simulated in ensemble runs with the same model is very minimal.

54 ENVIRONMENTAL SCIENCES↗

Simulator evaluation of manually flown curved MLS approaches

Pilot performance in flying horizontally curved instrument approaches was analyzed by having nine test subjects fly curved approaches in a fixed-base simulator. Approaches were flown without an autopilot and without a flight director. Evaluations were based on deviation measurements made at a number of points along the curved approach path and on subject questionnaires. Results indicate that pilots can fly curved approaches, though less accurately than streight-in approaches; that a moderate wind does not seriously affect curve flying performance; and that there is no major performance difference between 60 and 90 deg turns.

Sager, D.↗

Scanning Electrochemical Microscopy for Kinetic Investigations in Viscous Deep Eutectic Solvents: Identifying Practical Approach Curves and Deviations from Electron Transfer Models

Determining heterogeneous electrochemical electron transfer (ET) kinetics in electrolytes with a wide range of physical properties is of great interest for achieving high-performance redox flow batteries. Among such electrolytes, concentrated hydrogen-bonded electrolytes (CoHBEs), including deep eutectic solvents (DESs), have recently garnered significant attention. Unfortunately, traditional Tafel analysis using macroelectrodes often encounters issues with mass transfer limitations in CoHBEs with high viscosities, thereby restricting kinetic analysis to a narrow potential window. Here, in this work, we introduce a methodology for evaluating ET kinetics in viscous DES using the scanning electrochemical microscopy (SECM). We first determined practical solutions to SECM tip positioning in ethaline DES, which yield pseudopositive feedback responses. Lattice Boltzmann method (LBM) simulations helped us rationalize the impact of the fluid and concentration fields, as well as tip geometry, tip approach velocity v, and the solvent viscosity ηs, on the shape of the approach curves. In addition to successfully recreating approach curves over a variety of conditions, we found that approaching a conductor ensured a practical point where the normalized tip response (Ni T = 2) converged at L = 0.7 within ∼10% error regardless of tip velocity. With positioning capabilities at hand, we investigated the kinetics of Fe 3+ /Fe 2+ redox couple in aqueous and the ethaline media. The experimental kinetic results were interpreted using the Butler–Volmer (BV) and Marcus–Hush–Chidsey (MHC) models. For ethaline, a nonideal kinetic behavior was observed, potentially attributed to solvent dynamics within DESs or to the interplay of chloride anions in the charge transfer process.

electrodes↗

An Endorectal Balloon Reduces Intrafraction Prostate Motion During Radiotherapy

Purpose: To investigate the effect of endorectal balloons (ERBs) on intrafraction and interfraction prostate motion during radiotherapy. Methods and Materials: Thirty patients were treated with intensity-modulated radiotherapy, to a total dose of 80 Gy in 40 fractions. In 15 patients, a daily-inserted air-filled ERB was applied. Prostate motion was tracked, in real-time, using an electromagnetic tracking system. Interfraction displacements, measured before each treatment, were quantified by calculating the systematic and random deviations of the center of mass of the implanted transponders. Intrafraction motion was analyzed in timeframes of 150 s, and displacements >1 mm, >3 mm, >5 mm, and >7 mm were determined in the anteroposterior, left-right, and superoinferior direction, and for the three-dimensional (3D) vector. Manual table corrections, made during treatment sessions, were retrospectively undone. Results: A total of 576 and 567 tracks have been analyzed in the no-ERB group and ERB group, respectively. Interfraction variation was not significantly different between both groups. After 600 s, 95% and 98% of the treatments were completed in the respective groups. Significantly fewer table corrections were performed during treatment fractions with ERB: 88 vs. 207 (p = 0.02). Intrafraction motion was significantly reduced with ERB. During the first 150 s, only negligible deviations were observed, but after 150 s, intrafraction deviations increased with time. This resulted in cumulative percentages of 3D-vector deviations >1 mm, >3 mm, >5 mm, and >7 mm that were 57.7%, 7.0%, 0.7%, and 0.3% in the ERB-group vs. 70.2%, 18.1%, 4.6%, and 1.4% in the no-ERB group after 600 s. The largest reductions in the ERB group were observed in the AP direction. These data suggest that a 5 mm CTV-to-PTV margin is sufficient to correct for intrafraction prostate movements when using an ERB. Conclusions: ERB significantly reduces intrafraction prostate motion, but not interfraction variation, and may in particular be beneficial for treatment sessions longer than 150 s.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Avionics Configuration Assessment for Flightdeck Interval Management: A Comparison of Avionics and Notification Methods

Flightdeck Interval Management is one of the NextGen operational concepts that FAA is sponsoring to realize requisite National Airspace System (NAS) efficiencies. Interval Management will reduce variability in temporal deviations at a position, and thereby reduce buffers typically applied by controllers - resulting in higher arrival rates, and more efficient operations. Ground software generates a strategic schedule of aircraft pairs. Air Traffic Control (ATC) provides an IM clearance with the IM spacing objective (i.e., the TTF, and at which point to achieve the appropriate spacing from this aircraft) to the IM aircraft. Pilots must dial FIM speeds into the speed window on the Mode Control Panel in a timely manner, and attend to deviations between actual speed and the instantaneous FIM profile speed. Here, the crew is assumed to be operating the aircraft with autothrottles on, with autopilot engaged, and the autoflight system in Vertical Navigation (VNAV) and Lateral Navigation (LNAV); and is responsible for safely flying the aircraft while maintaining situation awareness of their ability to follow FIM speed commands and to achieve the FIM spacing goal. The objective of this study is to examine whether three Notification Methods and four Avionics Conditions affect pilots' performance, ratings on constructs associated with performance (workload, situation awareness), or opinions on acceptability. Three Notification Methods (alternate visual and aural alerts that notified pilots to the onset of a speed target, conformance deviation from the required speed profile, and reminded them if they failed to enter the speed within 10 seconds) were examined. These Notification Methods were: VVV (visuals for all three events), VAV (visuals for all three events, plus an aural for speed conformance deviations), and AAA (visual indications and the same aural to indicate all three of these events). Avionics Conditions were defined by the instrumentation (and location) used to present IM information to crews: (1) Integrated (IM information is embedded in extant PFD (Primary Flight Display), ND (Navigation Display), EICAS (Engine Indicating and Crew Alerting System) displays); (2) EFB_Aft (IM information is only supplied in an EFB and mounted in location similar to that for MITRE's UPS work); (3) EFB_Fore (IM information is only supplied in an EFB which is mounted more forward, under the side window), and (4) EFB_Aft plus use of an AGD (the same IM information is supplied in an EFB and on an AGD, both mounted in locations similar to that in MITRE's UPS work ). Twelve commercial pilot crews flew descent scenarios (VNAV Speed with the mode control panel (MCP) speed window open until flaps extended, then VNAV Path) in a commercial transport flight simulator with realistic visual scene and communications. The results of this study serve three practical aims: (1) contribute to the down-select of avionics configuration for future assessment of the ASTAR spacing algorithm at NASA; (2) provide information useful to the FAA Human Factors Division (ANG-C1)'s mission to identify issues pertinent to flight certification of, and flight standards; (3) identify methodological considerations in support of future FIM human-in-the-loop (HITL) investigations.

Latorella, Kara A.↗

Hydrogen maser clocks in space for solid-Earth research and time-transfer applications: Experiment overview and evaluation of Russian miniature sapphire loaded cavity

The Observatoire Cantonal de Neuchatel (ON) is developing for ESTEC a compact H-maser for space use based upon a miniature sapphire loaded microwave cavity, a technique pioneered at VNIIFTRI. Various contacts between West-European parties, headed by ESA, and the Russian parties, headed by ESA, led to the proposal for flying two H-masers on Meteor 3M, a Russian meteorology satellite in low polar orbit. The experiment will include two masers, one provided by ON and the other by VNIIFTRI. T/F transfer and precise positioning will be performed by both a microwave link, using PRARE equipment, and an optical link, using LASSO-like equipment. The main objectives of the experiment are precise orbit determination and point positioning for geodetic/geophysical research, ultra-accurate time comparison and dissemination as well as in-orbit demonstration of operation and performance of H-masers. Within the scope of a preliminary space H-maser development phase performed for ESTEC at ON in preparation to the joint experiment, a Russian miniature sapphire loaded microwave cavity, on loan from VNIIFTRI, was evaluated in a full-size EFOS hydrogen maser built by ON. The experimental evaluation confirmed the theoretical expectation that with a hydrogen storage volume of only 0.65 liter an atomic quality factor of 1.5 x 10(exp 9) can be obtained for a -105 dBm output power. This represents a theoretical Allan deviation of 1.7 x 10(exp -15) averaged on a 1000 s time interval. From a full-size design to a compact one, therefore, the sacrifice in performance due to the reduction of the storage volume is very small.

Busca, G.↗

Higgs production in association with a top-antitop pair in the Standard Model Effective Field Theory at NLO in QCD

We present the results of the computation of the next-to-leading order QCD corrections to the production cross section of a Higgs boson in association with a top-antitop pair at the LHC, including the three relevant dimension-six operators (O tφ , O φG , O tG ) of the standard model effective field theory. These operators also contribute to the production of Higgs bosons in loop-induced processes at the LHC, such as inclusive Higgs, Hj and HH production, and modify the Higgs decay branching ratios for which we also provide predictions. We perform a detailed study of the cross sections and their uncertainties at the total as well as differential level and of the structure of the effective field theory at NLO including renormalisation group effects. Finally, we show how the combination of information coming from measurements of these production processes will allow to constrain the three operators at the current and future LHC runs. Finally, our results lead to a significant improvement of the accuracy and precision of the deviations expected from higher-dimensional operators in the SM in both the top-quark and the Higgs-boson sectors and provide a necessary ingredient for performing a global EFT fit to the LHC data at NLO accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Quantum critical fluctuations in the heavy fermion compound Ce(Ni 0.935 Pd 0.065 ) 2 Ge 2

Electric resistivity, specific heat, magnetic susceptibility, and inelastic neutron scattering experi- ments were performed on a single crystal of the heavy fermion compound Ce(Ni 0.935 Pd 0.065 ) 2 Ge 2 in order to study the spin fluctuations near an antiferromagnetic (AF) quantum critical point (QCP). The resistivity and the specific heat coefficient for T ≤ 1 K exhibit the power law behavior expected for a 3D itinerant AF QCP (ρ(T) ~ T 3/2 and γ(T) ~ γ 0 - bT 1/2 ). However, for 2 ≤ T ≤ 10 K, the susceptibility and specific heat vary as log T and the resistivity varies linearly with temperature. Furthermore, despite the fact that the resistivity and specific heat exhibit the non-Fermi liquid behavior expected at a QCP, the correlation length, correlation time, and staggered susceptibility of the spin fluctuations remain finite at low temperature. We suggest that these deviations from the divergent behavior expected for a QCP may result from alloy disorder.

36 MATERIALS SCIENCE↗

Strength and texture of Pt compressed to 63 GPa

Angle- and energy-dispersive X-ray diffraction experiments in a radial geometry were performed in the diamond anvil cell on polycrystalline platinum samples at pressures up to 63 GPa. Observed yield strength and texture depend on grain size. For samples with 70–300-nm particle size, the yield strength is 5–6 GPa at ∼60 GPa. Coarse-grained (∼2-μm particles) Pt has a much lower yield strength of 1–1.5 GPa at ∼60 GPa. Face-centered cubic metals Pt and Au have lower strength to shear modulus ratio than body-centered cubic or hexagonal close-packed metals. While a 300-nm particle sample exhibits the 〈110〉 texture expected of face-centered-cubic metals under compression, smaller and larger particles show a weak mixed 〈110〉 and 〈100〉 texture under compression. Differences in texture development may also occur due to deviations from uniaxial stress under compression in the diamond anvil cell.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗