Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A thermodynamic model of integrated liquid-to-liquid thermoelectric heat pump systems

Thermoelectric (TE) heat pumps (TEHPs) are advantageous for heating and cooling in various applications because of their modularity and simple design. A TEHP system includes the TE modules with p- and n-type materials bonded to substrates, plus heat exchangers, thermal interfaces to the heat exchangers, and heat transfer fluids. Although modeling an individual TE module has been extensively studied, limited studies have reported performance at the larger system-level. Furthermore, no prior study has addressed the impact of temperature-dependent TE material properties (e.g., electric resistivity, thermal conductivity, and Seebeck coefficient) on overall heat-pump-system-level performance. Here, this work presents a mathematical model for TEHP system performance based on Goldsmid's approach for TE material performance, “effective” TE material properties, Gnielinski's correlation for convective heat transfer, and thermal balance theory for a heat exchange network. This combined approach provides an accurate model of the liquid-to-liquid TEHP system. Three different approaches—one empirical, one based on the manufacturer's specifications, and one drawn from the literature—were then used to determine values for TE material properties. The first two methods treated properties as constants, while the last approach treated properties as surface-temperature-based functions. Finally, experimental TEHP data was used to validate the models, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–25% when forecasting cooling capacity up to a 30 K surface temperature lift. The results demonstrated that, at the TEHP system level, the TE material properties could be treated as constants, avoiding solver iterations and reducing the performance uncertainty by up to 95%.

42 ENGINEERING↗

Decay Heat Surrogate Modeling for High Temperature Reactors

The accuracy of the safety analysis of Nuclear Power Plants, in general, and the High Temperature Reactors, in particular, is driven by several factors, among which the accuracy of decay heat curves or calculation. This paper is aimed to present a methodology based on the usage of the RAVEN code for the construction of a multi-dimensional decay heat curve for High Temperature Reactors, via calculations performed by ORIGEN. The main goal of this activity has been the identification of a model able to surrogate the phenomenology of the decay heat after shutdown, satisfying the following requirements: 1) Reasonable prediction accuracy till 1 month after the shutdown, 2) Ability to capture the main deviation effects determined by field conditions (e.g. burn-up, fuel temperature, fissile enrichment, etc.), 3) As easy as possible formalism in order to possibly allow the implementation of the curve into system codes (e.g. RELAP5-3D) inputs exploiting, for example, control variable capabilities. Three surrogate models (also known as decay heat curves in the safety analysis nomenclature) have been identified: 1) Spline Exponential surrogate model, 2) A Support Vector Regression model and, 3) A Dynamic Mode Decomposition model. The aim of this paper is to present the mathematical background of the identified surrogate models and their performance in the prediction of decay heat evolution for High Temperature Reactors. A preliminary comparison of the surrogate model performances is finally reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-144: Bayesian Inference of Local Relapse Data Using a Poisson-Based Tumour Control Probability Model

Purpose: The purpose of this project is to develop a robust method of parameter estimation for a Poisson-based TCP model using Bayesian inference. Methods: Bayesian inference was performed using the PyMC3 probabilistic programming framework written in Python. A Poisson-based TCP regression model that accounts for clonogen proliferation was fit to observed rates of local relapse as a function of equivalent dose in 2 Gy fractions for a population of 623 stage-I non-small-cell lung cancer patients. The Slice Markov Chain Monte Carlo sampling algorithm was used to sample the posterior distributions, and was initiated using the maximum of the posterior distributions found by optimization. The calculation of TCP with each sample step required integration over the free parameter α, which was performed using an adaptive 24-point Gauss-Legendre quadrature. Convergence was verified via inspection of the trace plot and posterior distribution for each of the fit parameters, as well as with comparisons of the most probable parameter values with their respective maximum likelihood estimates. Results: Posterior distributions for α, the standard deviation of α (σ), the average tumour cell-doubling time (Td), and the repopulation delay time (Tk), were generated assuming α/β = 10 Gy, and a fixed clonogen density of 10{sup 7} cm−{sup 3}. Posterior predictive plots generated from samples from these posterior distributions are in excellent agreement with the observed rates of local relapse used in the Bayesian inference. The most probable values of the model parameters also agree well with maximum likelihood estimates. Conclusion: A robust method of performing Bayesian inference of TCP data using a complex TCP model has been established.

60 APPLIED LIFE SCIENCES↗

Tree mortality submodels drive simulated long-term forest dynamics: assessing 15 models from the stand to global scale

Models are pivotal for assessing future forest dynamics under the impacts of changing climate and management practices, incorporating representations of tree growth, mortality, and regeneration. Quantitative studies on the importance of mortality submodels are scarce. We evaluated 15 dynamic vegetation models (DVMs) regarding their sensitivity to different formulations of tree mortality under different degrees of climate change. The set of models comprised eight DVMs at the stand scale, three at the landscape scale, and four typically applied at the continental to global scale. Some incorporate empirically derived mortality models, and others are based on experimental data, whereas still others are based on theoretical reasoning. Each DVM was run with at least two alternative mortality submodels. Model behavior was evaluated against empirical time series data, and then, the models were subjected to different scenarios of climate change. Most DVMs matched empirical data quite well, irrespective of the mortality submodel that was used. However, mortality submodels that performed in a very similar manner against past data often led to sharply different trajectories of forest dynamics under future climate change. Most DVMs featured high sensitivity to the mortality submodel, with deviations of basal area and stem numbers on the order of 10–40% per century under current climate and 20–170% under climate change. The sensitivity of a given DVM to scenarios of climate change, however, was typically lower by a factor of two to three. We conclude that (1) mortality is one of the most uncertain processes when it comes to assessing forest response to climate change, and (2) more data and a better process understanding of tree mortality are needed to improve the robustness of simulated future forest dynamics. Our study highlights that comparing several alternative mortality formulations in DVMs provides valuable insights into the effects of process uncertainties on simulated future forest dynamics.

54 ENVIRONMENTAL SCIENCES↗

Injection Locking of Gigahertz‐Frequency Surface Acoustic Wave Phononic Crystal Oscillator

Low-noise gigahertz (GHz) frequency sources are essential for applications in signal processing, sensing, and telecommunications. Surface acoustic wave (SAW) resonator-based oscillators offer compact form factors and low-phase noise due to their short mechanical wavelengths and high-quality (Q) factors. However, their small footprint makes them vulnerable to environmental variation, resulting in their poor long-term frequency stability. Injection locking is widely used to suppress frequency drift of lasers and oscillators by synchronizing to an ultra-stable reference. Here, injection locking of a 1-GHz SAW phononic-crystal oscillator is demonstrated, achieving 40-dB phase noise reduction at low offset frequencies and unperturbed low noise at large offset frequencies. Compared to a free-running SAW oscillator, which typically exhibits frequency drifts of several hundred hertz over minutes, the injection-locked oscillator reduces the frequency deviation to below 0.35 Hz. The locking range and oscillator dynamics is also investigated in the injection pulling region. The demonstrated injection-locked SAW oscillator could find applications in high-performance portable telecommunications and sensing systems.

injection locking↗

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

Stereographic Targeting in Prostate Radiotherapy: Speed and Precision by Daily Automatic Positioning Corrections Using Kilovoltage/Megavoltage Image Pairs

Purpose: A fully automated, fast, on-line prostate repositioning scheme using implanted markers, kilovoltage/megavoltage imaging, and remote couch movements has been developed and clinically applied. The initial clinical results of this stereographic targeting (SGT) method, as well as phantom evaluations, are presented. Methods and Materials: Using the SGT method, portal megavoltage images are acquired with the first two to six monitor units of a treatment beam, immediately followed by acquisition of an orthogonal kilovoltage image without gantry motion. The image pair is automatically analyzed to obtain the marker positions and three-dimensional prostate displacement and rotation. Remote control couch shifts are applied to correct for the displacement. The SGT performance was measured using both phantom images and images from 10 prostate cancer patients treated using SGT. Results: With phantom measurements, the accuracy of SGT was 0.5, 0.2, and 0.3 mm (standard deviation [SD]) for the left-right, craniocaudal, and anteroposterior directions, respectively, for translations and 0.5{sup o} (SD) for the rotations around all axes. Clinically, the success rate for automatic marker detection was 99.5%, and the accuracy was 0.3, 0.5 and 0.8 mm (SD) in the left-right, craniocaudal, and anteroposterior axes. The SDs of the systematic center-of-mass positioning errors ({sigma}) were reduced from 4.0 mm to <0.5 mm for all axes. The corresponding SD of the random ({sigma}) errors was reduced from 3.0 to <0.8 mm. These small residual errors were achieved with a treatment time extension of <1 min. Conclusion: Stereographic targeting yields systematic and random prostate positioning errors of <1 mm with <1 min of added treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Substitution Effect on Thiobarbituric Acid End Groups for High Open-Circuit Voltage Non-Fullerene Organic Solar Cells

Recent advances in non-fullerene acceptors (NFAs) have resulted in significant improvement in the power conversion efficiencies (PCEs) of organic solar cells (OSCs). In our efforts to boost open-circuit voltage (V OC ) for OSCs, the molecular design employing thiobarbituric acid (TBTA) end groups and an indacenodithieno[3,2-b]thiophene (IDTT) core gives rise to NFAs with significantly raised lowest unoccupied molecular orbital (LUMO) energy level, which, when paired with PCE10, can achieve V OC 's over 1.0 V and decent PCEs that outperform the equivalent devices based on the benchmark ITIC acceptor. While the use of a TBTA end group is effective in tuning energy levels, very little is known about how the alkyl substitution on the TBTA group impacts the solar cell performance. To this end, TBTA end groups are alkylated with linear, branched, and aromatic sidechains to understand the influence on thin-film morphology and related device performances. We report our study has confirmed the dependence of solar cell performance on the end-group substituents. More importantly, we reveal the presence of an ideal window of crystallinity associated with the medium-length hydrocarbon chains such as ethyl and benzyl. Deviation to the shorter methyl group makes the acceptor too crystalline to mix with the polymer donor and form proper domains, whereas longer and branched alkyl chains are too sterically bulky and hinder charge transport due to nonideal packing. Such findings underline the comprehensive nature of thin-film morphology and the subtle end-group effects for the design of non-fullerene acceptors.

14 SOLAR ENERGY↗

Hadronic uncertainties versus new physics for the W boson mass and Muon g – 2 anomalies

There are now two single measurements of precision observables that have major anomalies in the Standard Model: the recent CDF measurement of the W mass shows a 7σ deviation and the Muon g – 2 experiment at FNAL confirmed a long-standing anomaly, implying a 4.2σ deviation. Doubts regarding new physics interpretations of these anomalies could stem from uncertainties in the common hadronic contributions. We demonstrate that these two anomalies pull the hadronic contributions in opposite directions by performing electroweak fits in which the hadronic contribution was allowed to float. The fits show that including the g – 2 measurement worsens the tension with the CDF measurement and conversely that adjustments that alleviate the CDF tension worsen the g – 2 tension beyond 5σ. This means that if we adopt the CDF W mass measurement, the case for new physics in either the W mass or muon g – 2 is inescapable regardless of the size of the SM hadronic contributions. Lastly, we demonstrate that a mixed scalar leptoquark extension of the Standard Model could explain both anomalies simultaneously.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strain relaxation in short-period polar GaN/AlN superlattices

We have investigated the strain relaxation mechanisms in short-period polar GaN/AlN superlattices deposited by plasma-assisted molecular-beam epitaxy, and designed to display intersubband transitions at 1.55 mum. In a first stage, we have identified the growth conditions to minimize strain relaxation, using a Ga excess to reduce the (0001) surface free energy of both GaN and AlN. Under these growth conditions, crack propagation is not observed, even for the tensile-strained superlattices grown on GaN templates. The initial misfit relaxation in the vicinity of the buffer occurs by the formation of a-type dislocations. The final strain state of the superlattice, reached after 10-20 periods, is independent of the substrate (either GaN or AlN templates). Once the steady-state conditions are reached, we observe a periodic partial relaxation of quantum wells and barriers. High-resolution transmission electron microscopy indicates that the periodic relaxation can be related to the presence of basal and prismatic stacking faults creating clusters with an in-plane length of tens of nanometers. The effect of these defects on the optical performance of the superlattices is discussed by simulation of electronic structure using an 8x8kcentre dotp Schroedinger-Poisson solver. In the presence of basal stacking faults at the quantum well interfaces, the deviation of the e{sub 1}-e{sub 2} intersubband transition with respect to the nominal value is expected to be smaller than the measured absorption line width.

36 MATERIALS SCIENCE↗

Analysis of electron energy distribution function in the Linac4 H{sup −} source

To understand the Electron Energy Distribution Function (EEDF) in the Radio Frequency Inductively Coupled Plasmas (RF-ICPs) in hydrogen negative ion sources, the detailed analysis of the EEDFs using numerical simulation and the theoretical approach based on Boltzmann equation has been performed. It is shown that the EEDF of RF-ICPs consists of two parts, one is the low energy part which obeys Maxwellian distribution and the other is high energy part deviated from Maxwellian distribution. These simulation results have been confirmed to be reasonable by the analytical approach. The results suggest that it is possible to enhance the dissociation of molecules and the resultant H{sup −} negative ion production by reducing the gas pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of a plate-electrode XeCl laser with a pulse repetition rate up to 5 kHz

The results of the study of a repetitively pulsed XeCl laser with a high rate of pulse repetition and the electrode assembly based on a multi-section discharge gap with inductance-capacitance stabilisation of the discharge are presented. The multi-section discharge gap is formed by 25 pairs of anode - cathode plates. The discharge formed in the interelectrode gap had the dimensions 250 Multiplication-Sign 12 Multiplication-Sign 2 mm. The studies were performed using the HCl - Xe - Ne laser mixture at the total pressure up to 3.5 atm. The limit value of the radiation pulse repetition rate was equal to 5 kHz. The meansquare deviation of the pulse energy increased from 0.8 % to 1.6 % in the range of repetition rates from 1 to 4.5 kHz and did not exceed 2.4 % at the frequency 5 kHz. The maximal energy of the laser pulse and the efficiency coefficient were equal to 7.9 mJ and 1.6 %, respectively. The maximal power of laser radiation (31 W) was obtained at the repetition rate 5 kHz. A new technique of measuring the gas flow velocity in the interelectrode gap is proposed. The velocity of gas circulation at the maximal pressure of the mixture did not exceed 18 m s{sup -1}. Optical inhomogeneities were observed, caused by a high concentration of electrons in the discharge plasma, by the acoustic wave, arising in the discharge gap, and by the heating of the gas in the discharge. (lasers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Faraday dispersion functions of galaxies

The Faraday dispersion function (FDF), which can be derived from an observed polarization spectrum by Faraday rotation measure synthesis, is a profile of polarized emissions as a function of Faraday depth. We study intrinsic FDFs along sight lines through face-on Milky Way like galaxies by means of a sophisticated galactic model incorporating three-dimensional MHD turbulence, and investigate how much information the FDF intrinsically contains. Since the FDF reflects distributions of thermal and cosmic-ray electrons as well as magnetic fields, it has been expected that the FDF could be a new probe to examine internal structures of galaxies. We, however, find that an intrinsic FDF along a sight line through a galaxy is very complicated, depending significantly on actual configurations of turbulence. We perform 800 realizations of turbulence and find no universal shape of the FDF even if we fix the global parameters of the model. We calculate the probability distribution functions of the standard deviation, skewness, and kurtosis of FDFs and compare them for models with different global parameters. Our models predict that the presence of vertical magnetic fields and the large-scale height of cosmic-ray electrons tend to make the standard deviation relatively large. In contrast, the differences in skewness and kurtosis are relatively less significant.

79 ASTRONOMY AND ASTROPHYSICS↗

Onset of nuclear structure effects in near-barrier elastic scattering of weakly bound nuclei: {sup 6}He and {sup 6}Li compared

The elastic scattering of the halo nucleus {sup 6}He from heavy targets at incident energies near the Coulomb barrier displays a marked deviation from the standard Fresnel-type diffraction behavior. This deviation is due to the strong Coulomb dipole breakup coupling produced by the Coulomb field of the heavy target, a specific feature of the nuclear structure of {sup 6}He. We have performed Continuum Discretized Coupled Channels calculations for the elastic scattering of {sup 6}He and {sup 6}Li from {sup 58}Ni, {sup 120}Sn, {sup 144}Sm, {sup 181}Ta and {sup 208}Pb targets in order to determine the range of Z{sub T} where this nuclear-structure specific coupling effect becomes manifest. We find that the strong Coulomb dipole breakup coupling effect is only clearly experimentally distinguishable for targets of Z{sub T}{approx_equal}80.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for Z' resonances decaying to tt¯; in dilepton+jets final states in pp collisions at √s=7 TeV

A search for resonances decaying to top quark-antiquark pairs is performed using a dilepton+jets data sample recorded by the CMS experiment at the LHC in pp collisions at √s=7 TeV corresponding to an integrated luminosity of 5.0 b⁻¹. No significant deviations from the standard model background are observed. Upper limits are presented for the production cross section times branching fraction of top quark-antiquark resonances for masses from 750 to 3000 GeV. In particular, the existence of a leptophobic topcolor particle Z' is excluded at the 95% confidence level for resonance masses M Z' <1.3 TeV for Γ Z' =0.012MZ', and M<1.9 TeV for Γ Z' =0.10MZ'.

Chatrchyan, S.↗