Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ranking methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Lightweight and effective tensor sensitivity for atomistic neural networks

Atomistic machine learning focuses on the creation of models that obey fundamental symmetries of atomistic configurations, such as permutation, translation, and rotation invariances. In many of these schemes, translation and rotation invariance are achieved by building on scalar invariants, e.g., distances between atom pairs. There is growing interest in molecular representations that work internally with higher rank rotational tensors, e.g., vector displacements between atoms, and tensor products thereof. Here, we present a framework for extending the Hierarchically Interacting Particle Neural Network (HIP-NN) with Tensor Sensitivity information (HIP-NN-TS) from each local atomic environment. Crucially, the method employs a weight tying strategy that allows direct incorporation of many-body information while adding very few model parameters. We show that HIP-NN-TS is more accurate than HIP-NN, with negligible increase in parameter count, for several datasets and network sizes. As the dataset becomes more complex, tensor sensitivities provide greater improvements to model accuracy. In particular, HIP-NN-TS achieves a record mean absolute error of 0.927 $\frac{\text{kcal}}{\text{mol}}$ for conformational energy variation on the challenging COMP6 benchmark, which includes a broad set of organic molecules. We also compare the computational performance of HIP-NN-TS to HIP-NN and other models in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum mixed state compiling

The task of learning a quantum circuit to prepare a given mixed state is a fundamental quantum subroutine. We present a variational quantum algorithm (VQA) to learn mixed states which is suitable for near-term hardware. Our algorithm represents a generalization of previous VQAs that aimed at learning preparation circuits for pure states. We consider two different ansätze for compiling the target state; the first is based on learning a purification of the state and the second on representing it as a convex combination of pure states. In both cases, the resources required to store and manipulate the compiled state grow with the rank of the approximation. Thus, by learning a lower rank approximation of the target state, our algorithm provides a means of compressing a state for more efficient processing. As a byproduct of our algorithm, one effectively learns the principal components of the target state, and hence our algorithm further provides a new method for principal component analysis. We investigate the efficacy of our algorithm through extensive numerical implementations, showing that typical random states and thermal states of many body systems may be learnt this way. Additionally, we demonstrate on quantum hardware how our algorithm can be used to study hardware noise-induced states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-243: Major Risks in Radiotherapy. A Review Based On Risk Analysis Literature

Purpose: We present a literature review of risk analyses in radiotherapy to highlight the most reported risks and facilitate the spread of this valuable information so that professionals can be aware of these major threats before performing their own studies. Methods: We considered studies with at least an estimation of the probability of occurrence of an adverse event (O) and its associated severity (S). They cover external beam radiotherapy, brachytherapy, intraoperative radiotherapy, and stereotactic techniques. We selected only the works containing a detailed ranked series of elements or failure modes and focused on the first fully reported quartile as much. Afterward, we sorted the risk elements according to a regular radiotherapy procedure so that the resulting groups were cited in several works and be ranked in this way. Results: 29 references published between 2007 and February 2016 were studied. Publication trend has been generally rising. The most employed analysis has been the Failure mode and effect analysis (FMEA). Among references, we selected 20 works listing 258 ranked risk elements. They were sorted into 31 groups appearing at least in two different works. 11 groups appeared in at least 5 references and 5 groups did it in 7 or more papers. These last sets of risks where choosing another set of images or plan for planning or treating, errors related with contours, errors in patient positioning for treatment, human mistakes when programming treatments, and planning errors. Conclusion: There is a sufficient amount and variety of references for identifying which failure modes or elements should be addressed in a radiotherapy department before attempting a specific analysis. FMEA prevailed, but other studies such as “risk matrix” or “occurrence × severity” analyses can also lead professionals’ efforts. Risk associated with human actions ranks very high; therefore, they should be automated or at least peer-reviewed.

60 APPLIED LIFE SCIENCES↗

Summary Report of the FY24 DOE Contributions to the GIF VHTR CMVB

The Generation-IV Forum (GIF) Very-High-Temperature Reactor-Computational Methods Validation and Benchmark (VHTR-CMVB) initiative, involving organizations from Korea Atomic Energy Research Institute (KAERI) (South Korea), Institute of Nuclear and New Energy Technology of Tsinghua University (INET) (China), U.S. Department of Energy (DOE) (U.S.), Joint Research Centre (JRC) (Europe), and Japan Atomic Energy Agency (JAEA) (Japan), is dedicated to the verification and validation of tools for High-Temperature Gas-Cooled Reactors (HTGRs) analysis, using data shared by Computational Methods Validation and Benchmark (CMVB) signatories. For FY24, the US DOE CMVB has committed to several critical activities. Under WP1, led by the US, the integration of the High Temperature Gas Cooled Reactor - Pebble-Bed Module (HTR-PM) Phenomena Identification and Ranking Table (PIRT) into the comparative PIRT is progressing, with a new draft of the comparison tables issued earlier this year and currently being utilized by INET for their contribution. Neutronic validation efforts under WP3 include the preparation of the burnup analysis benchmark, preliminary calculations, and the development of reference models and results. In WP2, a validation exercise for hot gas mixing in the lower plenum of HTR-PM is in progress, using experimental data from INET (China) to validate modeling approaches. A model of the experimental facility has been developed using StarCCM+, with initial calculations slated for presentation at the GIF CMVB meeting this fall. Another WP2 activity focuses on validating numerical models for air-cooled Reactor Cavity Cooling System (RCCS) with experimental data from the Wisconsin Madison RCCS facility. A high-fidelity model, developed using NEK-RS, is currently being validated with available data from a low power forced convection test. These efforts are aimed at enhancing and confirming the accuracy of HTGR analysis tools, ensuring their alignment with experimental data and regulatory requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probabilistic methods for sensitivity analysis and calibration in the NASA challenge problem

In this study, a series of algorithms are proposed to address the problems in the NASA Langley Research Center Multidisciplinary Uncertainty Quantification Challenge. A Bayesian approach is employed to characterize and calibrate the epistemic parameters based on the available data, whereas a variance-based global sensitivity analysis is used to rank the epistemic and aleatory model parameters. A nested sampling of the aleatory–epistemic space is proposed to propagate uncertainties from model parameters to output quantities of interest.

97 MATHEMATICS AND COMPUTING↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

TOPSIS with similarity measure for MADM applied to network selection

In this article, a new method is introduced to handle fuzzy multi-attribute decision-making problems. The method preserves fuzziness in the preference technique to avoid the drawbacks of defuzzification. The study modifies the technique of order preference by similarity to an ideal solution (TOPSIS) for interval-valued fuzzy numbers. The traditional TOPSIS uses the relative degree of closeness to rank the alternatives. Instead, a similarity measure based on map distance is used for preference. The degree of similarity between each attribute of an alternative and the ideal solution is computed, and a similarity matrix is formed. Then, the total degree of similarity for all the attributes of an alternative is used for ranking. The alternative corresponding to the one norm of the similarity matrix is the best alternative. Thus, the comparison is done on a fuzzy basis to avoid the loss of information due to converting the elements of the weighted normalized decision matrix to crisp values by defuzzification. An illustrative example is given to demonstrate the approach. A practical example in network selection to optimize vertical hand offs is solved where both user preferences and network parameters are treated as interval-valued fuzzy numbers.

97 MATHEMATICS AND COMPUTING↗

Comparison of Dose Distributions With TG-43 and Collapsed Cone Convolution Algorithms Applied to Accelerated Partial Breast Irradiation Patient Plans

Purpose: To compare the treatment plans for accelerated partial breast irradiation calculated by the new commercially available collapsed cone convolution (CCC) and current standard TG-43–based algorithms for 50 patients treated at our institution with either a Strut-Adjusted Volume Implant (SAVI) or Contura device. Methods and Materials: We recalculated target coverage, volume of highly dosed normal tissue, and dose to organs at risk (ribs, skin, and lung) with each algorithm. For 1 case an artificial air pocket was added to simulate 10% nonconformance. We performed a Wilcoxon signed rank test to determine the median differences in the clinical indices V90, V95, V100, V150, V200, and highest-dosed 0.1 cm{sup 3} and 1.0 cm{sup 3} of rib, skin, and lung between the two algorithms. Results: The CCC algorithm calculated lower values on average for all dose-volume histogram parameters. Across the entire patient cohort, the median difference in the clinical indices calculated by the 2 algorithms was <10% for dose to organs at risk, <5% for target volume coverage (V90, V95, and V100), and <4 cm{sup 3} for dose to normal breast tissue (V150 and V200). No discernable difference was seen in the nonconformance case. Conclusions: We found that on average over our patient population CCC calculated (<10%) lower doses than TG-43. These results should inform clinicians as they prepare for the transition to heterogeneous dose calculation algorithms and determine whether clinical tolerance limits warrant modification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploration of a Potential DOOR Endpoint for Hospital-acquired Bacterial Pneumonia and Ventilator-associated Bacterial Pneumonia Using Six Registrational Trials for Antibacterial Drugs

Abstract Background Desirability of outcome ranking (DOOR) is an innovative approach to clinical trial design and analysis that uses an ordinal ranking system to incorporate the overall risks and benefits of a therapeutic intervention into a single measurement. Here we derived and evaluated a disease-specific DOOR endpoint for registrational trials for hospital-acquired bacterial pneumonia and ventilator-associated bacterial pneumonia (HABP/VABP). Methods Through comprehensive examination of data from nearly 4000 participants enrolled in six registrational trials for HABP/VABP submitted to the Food and Drug Administration (FDA) between 2005 and 2022, we derived and applied a HABP/VABP specific endpoint. We estimated the probability that a participant assigned to the study treatment arm would have a more favorable overall DOOR or component outcome than a participant assigned to comparator. Results DOOR distributions between treatment arms were similar in all trials. DOOR probability estimates ranged from 48.3% to 52.9% and were not statistically different. There were no significant differences between treatment arms in the component analyses. Although infectious complications and serious adverse events occurred more frequently in ventilated participants compared to non-ventilated participants, the types of events were similar. Conclusions Through a data-driven approach, we constructed and applied a potential DOOR endpoint for HABP/VABP trials. The inclusion of syndrome-specific events may help to better delineate and evaluate participant experiences and outcomes in future HABP/VABP trials and could help inform data collection and trial design.

Immunology↗

A highly efficient atomically thin curved PdIr bimetallene electrocatalyst

Abstract The multi-metallene with an ultrahigh surface area has great potential in precise tuning of surface heterogeneous d-electronic correlation by surface strain effect for the distinctive surface electronic structure, which is a brand new class of promising 2D electrocatalyst for sustainable energy device application. However, achieving such an atomically thin multi-metallene still presents a great challenge. Herein, we present a new synthetic method for an atomic-level palladium-iridium (PdIr) bimetallene with an average thickness of only ∼1.0 nm for achieving superior catalysis in the hydrogen evolution reaction (HER) and the formic acid oxidation reaction (FAOR). The curved PdIr bimetallene presents a top-ranked high electrochemical active area of 127.5 ± 10.8 m2 gPd+Ir−1 in the reported noble alloy materials, and exhibits a very low overpotential, ultrahigh activity and improved stability for HER and FAOR. DFT calculation reveals that the PdIr bimetallene herein has a unique lattice tangential strain, which can induce surface distortion while concurrently creating a variety of concave-convex featured micro-active regions formed by variously coordinated Pd sites agglomeration. Such a strong strain effect correlates the abnormal on-site active 4d10-t2g-orbital Coulomb correlation potential and directly elevates orbital-electronegativity exposure within these active regions, resulting in a preeminent barrier-free energetic path for significant enhancement of FAOR and HER catalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regional radiation dose susceptibility within the parotid gland: Effects on salivary loss and recovery

Purpose: Xerostomia is one of the most likely late toxic effects of radiotherapy treatment in patients with head-and-neck cancers. Modern treatment techniques can incorporate knowledge of complication risk into treatment plans. To this end, the authors attempt to quantify the regional radiotherapy dose-dependence of salivary output loss and recovery in a prospective study. Methods: Salivary output was collected from patients undergoing radiotherapy treatment for head-and-neck cancers at the BC Cancer Agency between February 2008 and May 2013. Regional dose-dependence (i.e., dose susceptibility) of loss and recovery is quantified using nonparametric (Spearman’s rank correlation coefficients, local linear regression) and parametric (least-sum of squares, least-median of squares) techniques. Results: Salivary flow recovery was seen in 79 of 102 patients considered (p < 0.0001, Wilcoxon sign rank test). Output loss was strongly correlated with left- and right parotid combined dose φ = min (D{sub L}, 45 Gy) + min (D{sub R}, 45 Gy), and can be accurately predicted. Median early loss (three months) was 72% of baseline, while median overall loss (1 yr) was 56% of baseline. Fitting an exponential model to whole parotid yields dose sensitivities A{sub 3m} = 0.0604 Gy{sup −1} and A{sub 1y} = 0.0379 Gy{sup −1}. Recovery was not significantly associated with dose. Hints of lateral organ sub-segment dose–response dimorphism were observed. Conclusions: Sub-segmentation appears to predict neither loss nor recovery with any greater precision than whole parotid mean dose, though it is not any worse. Sparing the parotid to a combined dose φ of <50 Gy is recommended for a patient to keep ≈40% of baseline function and thus avoid severe xerostomia at 12 months post-treatment. It seems unlikely that a population’s mean recovery will exceed 20%–30% of baseline output at 1 yr after radiotherapy treatment using current (whole-organ based) clinical guidelines.

60 APPLIED LIFE SCIENCES↗

Can radiomics features be reproducibly measured from CBCT images for patients with non-small cell lung cancer?

Purpose: Increasing evidence suggests radiomics features extracted from computed tomography (CT) images may be useful in prognostic models for patients with nonsmall cell lung cancer (NSCLC). This study was designed to determine whether such features can be reproducibly obtained from cone-beam CT (CBCT) images taken using medical Linac onboard-imaging systems in order to track them through treatment. Methods: Test-retest CBCT images of ten patients previously enrolled in a clinical trial were retrospectively obtained and used to determine the concordance correlation coefficient (CCC) for 68 different texture features. The volume dependence of each feature was also measured using the Spearman rank correlation coefficient. Features with a high reproducibility (CCC > 0.9) that were not due to volume dependence in the patient test-retest set were further examined for their sensitivity to differences in imaging protocol, level of scatter, and amount of motion by using two phantoms. The first phantom was a texture phantom composed of rectangular cartridges to represent different textures. Features were measured from two cartridges, shredded rubber and dense cork, in this study. The texture phantom was scanned with 19 different CBCT imagers to establish the features’ interscanner variability. The effect of scatter on these features was studied by surrounding the same texture phantom with scattering material (rice and solid water). The effect of respiratory motion on these features was studied using a dynamic-motion thoracic phantom and a specially designed tumor texture insert of the shredded rubber material. The differences between scans acquired with different Linacs and protocols, varying amounts of scatter, and with different levels of motion were compared to the mean intrapatient difference from the test-retest image set. Results: Of the original 68 features, 37 had a CCC >0.9 that was not due to volume dependence. When the Linac manufacturer and imaging protocol were kept consistent, 4–13 of these 37 features passed our criteria for reproducibility more than 50% of the time, depending on the manufacturer-protocol combination. Almost all of the features changed substantially when scatter material was added around the phantom. For the dense cork, 23 features passed in the thoracic scans and 11 features passed in the head scans when the differences between one and two layers of scatter were compared. Using the same test for the shredded rubber, five features passed the thoracic scans and eight features passed the head scans. Motion substantially impacted the reproducibility of the features. With 4 mm of motion, 12 features from the entire volume and 14 features from the center slice measurements were reproducible. With 6–8 mm of motion, three features (Laplacian of Gaussian filtered kurtosis, gray-level nonuniformity, and entropy), from the entire volume and seven features (coarseness, high gray-level run emphasis, gray-level nonuniformity, sum-average, information measure correlation, scaled mean, and entropy) from the center-slice measurements were considered reproducible. Conclusions: Some radiomics features are robust to the noise and poor image quality of CBCT images when the imaging protocol is consistent, relative changes in the features are used, and patients are limited to those with less than 1 cm of motion.

60 APPLIED LIFE SCIENCES↗

Comparative Iron Oxide Nanoparticle Cellular Dosimetry and Response in Mice by the Inhalation and Liquid Cell Culture Exposure Routes

testing the rapidly growing number of nanomaterials requires large scale use of in vitro systems under the presumption that these systems are sufficiently predictive or descriptive of responses in in vivo systems for effective use in hazard ranking. We hypothesized that improved relationships between in vitro and in vivo models of experimental toxicology for nanomaterials would result from placing response data in vitro and in vivo on the same dose scale, the amount of material associated with cells (target cell dose). Methods: Balb/c mice were exposed nose-only to an aerosol of 12.8 nm (68.6 nm CMD, 19.9 mg/m3, 4 hours) super paramagnetic iron oxide particles, target cell doses were calculated and biomarkers of response anchored with histological evidence were identified by global transcriptomics. Representative murine epithelial and macrophage cell types were exposed in vitro to the same material in liquid suspension for four hours and levels nanoparticle regulated cytokine transcripts identified in vivo were quantified as a function of measured nanoparticle cellular dose. Results. Target tissue doses of 0.009-0.4 μg SPIO/cm2 lung led to an inflammatory response in the alveolar region characterized by interstitial inflammation and macrophage infiltration. In vitro, higher target tissue doses of ~1.2-4 μg SPIO/ cm2 of cells were required to induce transcriptional regulation of markers of inflammation, CXCL2 CCL3, in C10 lung epithelial cells. Estimated in vivo macrophage SPIO nanoparticle doses ranged from 1-100 pg/cell, and induction of inflammatory markers was observed in vitro in macrophages at doses of 8-35 pg/cell. Conclusions: Application of target tissue dosimetry revealed good correspondence between target cell doses triggering inflammatory processes in vitro and in vivo in the alveolar macrophage population, but not in the epithelial cells of the alveolar region. These findings demonstrate the potential for target tissue dosimetry to enable the more quantitative comparison of in vitro and in vivo systems advance their use for hazard assessment and extrapolation to humans. The mildly inflammogentic cellular doses experienced by mice were similar those calculated for humans exposed to the same at the existing permissible exposure limit of 10 mg/m3 iron oxide (as Fe).

Dosimetry↗

Zoned namespaces for computing device main memory

Disclosed in some examples are methods, systems, memory devices, memory controllers, and machine-readable mediums which provide for reserving physical memory device resources to specific execution units. Execution units may include processes, threads, virtual machines, functions, procedures, or the like. Physical memory device resources may include channels, modules, ranks, banks, bank groups, and the like. For example, a physical memory device resource that is reservable may be a smallest unit that allows for parallel access with another of the same size unit.

Sheridan, Patrick Michael↗

Assessment of metal artifact reduction methods in pelvic CT

Purpose: Metal artifact reduction (MAR) produces images with improved quality potentially leading to confident and reliable clinical diagnosis and therapy planning. In this work, the authors evaluate the performance of five MAR techniques for the assessment of computed tomography images of patients with hip prostheses. Methods: Five MAR algorithms were evaluated using simulation and clinical studies. The algorithms included one-dimensional linear interpolation (LI) of the corrupted projection bins in the sinogram, two-dimensional interpolation (2D), a normalized metal artifact reduction (NMAR) technique, a metal deletion technique, and a maximum a posteriori completion (MAPC) approach. The algorithms were applied to ten simulated datasets as well as 30 clinical studies of patients with metallic hip implants. Qualitative evaluations were performed by two blinded experienced radiologists who ranked overall artifact severity and pelvic organ recognition for each algorithm by assigning scores from zero to five (zero indicating totally obscured organs with no structures identifiable and five indicating recognition with high confidence). Results: Simulation studies revealed that 2D, NMAR, and MAPC techniques performed almost equally well in all regions. LI falls behind the other approaches in terms of reducing dark streaking artifacts as well as preserving unaffected regions (p < 0.05). Visual assessment of clinical datasets revealed the superiority of NMAR and MAPC in the evaluated pelvic organs and in terms of overall image quality. Conclusions: Overall, all methods, except LI, performed equally well in artifact-free regions. Considering both clinical and simulation studies, 2D, NMAR, and MAPC seem to outperform the other techniques.

60 APPLIED LIFE SCIENCES↗

Discovering Geothermal Systems in the Great Basin Region: An Integrated Geologic, Geochemical, and Geophysical Approach for Establishing Geothermal Play Fairways

The Great Basin currently hosts ~24 geothermal power plants with more than 600 MW of capacity, but estimates suggest that the region is capable of producing much greater amounts of geothermal energy. Recent studies indicate that a combination of geological, geochemical, and geophysical features characterize the most robust geothermal systems. Considering that most of the geothermal resources in this region are blind, it is imperative that the favorable characteristics for geothermal activity be synthesized and techniques perfected for the discovery of new viable systems. We therefore utilized a multi-disciplinary approach and synthesized 9 geologic, geochemical, and geophysical parameters to produce a new detailed geothermal play fairway map of a large transect across the Great Basin region (96,000 km2) from west-central to eastern Nevada, with the primary objective of facilitating discovery of commercial-grade, blind geothermal fields (i.e. systems with no surface hot springs or fumaroles). Our analysis included: 1) structural settings (i.e., patterns of faulting), 2) age of recent faulting, 3) slip rates on recent faults, 4) regional-scale strain rates, 5) the tendency of faults to slip or dilate based on their orientation in the regional stress field, 6) earthquake density, 7) gravity data, 8) temperature at 3 km depth, and 9) geochemistry from springs and wells. These parameters were grouped into subsets to delineate rankings for local permeability, regional permeability, and heat, which collectively defined the geothermal play fairways (i.e., most likely locations for significant geothermal fluid flow). A major challenge was developing appropriate weightings of individual data types to best predict permeability and overall geothermal potential. Rigorous statistical methods, utilizing 34 benchmarks of known relatively high-temperature (>130°C) geothermal systems in the region, were employed to determine the hierarchal weights of each parameter. The new geothermal potential maps will help to reduce the risks in prospecting for new geothermal systems throughout the region.

15 GEOTHERMAL ENERGY↗

Tumor Response and Apoptosis of N1-S1 Rodent Hepatomas in Response to Intra-arterial and Intravenous Benzamide Riboside

Purpose: Benzamide riboside (BR) induces tumor apoptosis in multiple cell lines and animals. This pilot study compares apoptosis and tumor response in rat hepatomas treated with hepatic arterial BR (IA) or intravenous (IV) BR. Methods: A total of 10{sup 6} N1-S1 cells were placed in the left hepatic lobes of 15 Sprague-Dawley rats. After 2 weeks, BR (20 mg/kg) was infused IA (n = 5) or IV (n = 5). One animal in each group was excluded for technical factors, which prevented a full dose administration (1 IA and 1 IV). Five rats received saline (3 IA and 2 IV). Animals were killed after 3 weeks. Tumor volumes after IA and IV treatments were analyzed by Wilcoxon rank sum test. The percentage of tumor and normal liver apoptosis was counted by using 10 fields of TUNEL (terminal deoxynucleotidyl transferase dUTP nick-end labeling)-stained slides at 40 Multiplication-Sign magnification. The percentage of apoptosis was compared between IV and IA administrations and with saline sham-treated rats by the Wilcoxon rank sum test. Results: Tumors were smaller after IA treatment, but this did not reach statistical significance (0.14 IA vs. 0.57 IV; P = 0.138). There was much variability in percentage of apoptosis and no significant difference between IA and IV BR (44.49 vs. 1.52%; P = 0.18); IA BR and saline (44.49 vs. 33.83%; P = 0.66); or IV BR and saline (1.52 vs. 193%; P = 0.18). Conclusions: Although differences in tumor volumes did not reach statistical significance, there was a trend toward smaller tumors after IA BR than IV BR in this small pilot study. Comparisons of these treatment methods will require a larger sample size and repeat experimentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal mechanics-based thermo-elastic constitutive modeling of orthorhombic uranium using generalized spherical harmonics and first-order bounding theories

In earlier works, a mathematical procedure for invertible microstructure-property linkages was developed using computationally efficient spectral methods for polycrystalline cubic and hexagonal metals. This paper formulates such invertible microstructure–property linkages for orthorhombic polycrystalline metals relying on the generalized spherical harmonics (GSH) spectral basis. The procedure is used to compute property closures of orthorhombic polycrystals. The closures represent the complete set of theoretically possible combinations of effective properties for a selected material. The procedure relies on the first-order bounding theories and considers orientation distribution functions (ODFs) as the main microstructural descriptor influencing homogenized properties. Numerous examples of these closures involving second-rank thermal expansion and fourth-rank elastic stiffness tensorial properties over a broad range of temperatures are presented for α-uranium (α-U). In doing so, certain key properties of these closures are exploited to facilitate their computation with drastically reduced computational effort. Along with the recently developed GSH-based interpolation procedure for ODFs from coarsely spaced experimental measurement grids to finely spaced finite element mesh resolution grids presented in Barrett et al., the developed computationally efficient ODF-effective property linkages are used to establish a crystal mechanics-based simulation framework coupled with the finite element method (FEM). The ODF dependent thermal expansion and elastic stiffness tensors are efficiently calculated at every integration point and used by the FEM to predict the overall distortion of a hemispherical part made of α-U during heating. In conclusion, it is shown that the developed framework can be used to simulate microstructurally heterogeneous components under thermo-mechanical loadings in a computationally efficient manner.

36 MATERIALS SCIENCE↗