Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

NR-150B2 adhesive development

Adhesive based polyimide solutions which are more easily processed than conventional aromatic polyimide systems and show potential for use for extended times at 589K are discussed. The adhesive system is based on a solution containing diglyme as the solvent and 2,2 bis(3',4'-dicarboxyphenyl)hexafluoropropane, paraphenylenediamine, and oxydianiline. The replacement of N-methylpyrrolidone with diglyme as the solvent was found to improve the adhesive strengths of lap shear samples and simplify the processing conditions for bonding both titanium and graphite fiber/polyimide matrix resin composites. Information was obtained on the effects of various environments including high humidity, immersion in jet fuel and methylethylketone on aluminum filled adhesive bonds. The adhesive was also evaluated in wide area bonds and flatwise tensile specimens using titanium honeycomb and composite face sheets. It was indicated that the developed adhesive system has the potential for use in applications requiring long term exposure to at least 589K (600 F).

Blatz, P. S.↗

Preserving and Curating the Moon: Adventures in Lunar Core Processing

The lunar crust is the most easily accessible part of the Moon to both remote sensing and sample analyses and provides an archive of information about planetary formation, crustal evolution, and contains a wealth of information about the origin of the Earth-Moon system [e.g., 1-5]. The Apollo mission returned 382 kg of rocks, soil and core samples. Studies of these lunar samples are crucial for our understanding of the Moon’s formation and geological evolution, and for the past 50 years these returned samples have provided the foundation for lunar science [5]. The returned samples are stored and cared for in the lunar curation facility at NASA’s Johnson Space Center. This facility is comprised of a large suite of clean rooms, sample vaults for pristine and return samples, thin section labs, core and saw rooms, storage and working areas, and ancillary labs all designed to minimize contamination from the environment and other samples. Some of the returned samples were intentionally set aside and left unopened. Recently, the Apollo Next Generation Sample Analysis (ANGSA) initiative was designed to examine these pristine samples so the next generation of lunar scientists can further our insight into the Moon’s history. Here, we present the meticulous process that involves preparing for, and ultimately opening, one of the unopened core samples: Apollo 17 drive tube 73002,0,which was collected on the Moon from a landslide deposit near Lara Crater by astronauts Gene Cernan and Jack Schmitt. In order to open, examine, and curate 73002,0withminimalpotential contamination, great care had to be taken prior to opening its container. Beginning18 months before extrusion of the sample, all core processing equipment was pulled out of storage, identified, sorted, cleaned, and purged with nitrogen gas. However, limited institutional memory has made this step challenging as most of the former core processors from the Apollo area have retired or passed away. Twelvemonths prior to extrusion, table-top rehearsals were initiated to identify equipment and learn how it fits together and operates. Five months before extruding the real core, preparations further evolved to include the extrusion and dissection of a lunar core simulant. In addition, a mock-up glovebox was designed and built to allow for a more realistic practice environment. One month prior to extrusion, the actual core cabinet was prepared for use, which included fitting it with lights, a webcam, and power. The tool and equipment cleaning procedure was also modified to include increased cleanliness and sterility requirements. While still sealed, the core was CT scanned at the University of Texas at Austin to maximize its scientific return. Days before the extrusion, witness plates and foil were deployed inside the core cabinet to monitor potential particle and organic contamination within the cabinet. On Nov. 5th, 2019, core sample 73002,0 was successfully opened and extruded(Fig.1). Dissection of 73002,0 began immediately afterwards and is still under way. Processing this sample will help us prepare for future sampling missions and core extrusions and will enable new scientific discoveries about the Moon.

C H Krysher↗

SPARCLE: Validation of Observing System Simulations (SPace Readiness Coherent Lidar Experiment)

NASA recently approved a mission to fly a Doppler Wind Lidar (DWL) on a U.S. Space Shuttle. SPARCLE, managed by Marshall Space Flight Center in Huntsville, AL, is targeted for launch in March 2001. This mission is viewed as a necessary demonstration of a solid state (2 micron) lidar using coherent detection before committing resources to a 3-5 year research or operational mission. While, to many, this shuttle mission is seen as the first step in a series leading to a fully operational wind observing system, to others, it is a chance to validate predictions of performance based upon theoretical models, analyses of airborne and ground-based data, and sophisticated observing system simulation experiments. This paper will be presented in two parts: first a brief overview of the SPARCLE mission and second, a summary of current performance predictions and key contributions from ground- based and airborne DWL research. The SPARCLE instrument is a 100 mJ, 6 Hz, diode-pumped 2-micron laser with a .25 m telescope using heterodyne mixing in a fiber and an InGaAs detector. A 25 cm silicon wedge scanner will be used in step-stare modes with dwells ranging from 60 seconds to .5 seconds. Pointing knowledge is achieved with a dedicated GPS/INS mounted close to the lidar. NASA's Hitchhiker program is providing the instrument enclosures (2 cans) and mission logistics support. An on-board data system is sized to record 150 Gbytes of raw signal from a two 400 MHZ A/D converters. On-board signal processing will be used to control the frequency of the Local Oscillator. SPARCLE is predicted to have a single shot backscatter sensitivity near 1x10(exp -6) m-1 sr-1, To achieve higher sensitivity, shot accumulation will be employed. Ground-based, 2 micron DWLs have been used to assess the benefits of shot accumulation (approximately SQRT for SNR). Airborne programs like MACAWS have provided good datasets for evaluating various sampling strategies and signal processing algorithms. Using these real data to calibrate our simulation models, we can describe when and how well SPARCLE is expected to preform. Outputs from these performance models will be presented.

Emmitt, G. D.↗

Instrumentation for optical ocean remote sensing

Instruments used in ocean color remote sensing algorithm development, validation, and data acquisition which have the potential for further commercial development and marketing are discussed. The Ocean Data Acquisition System (ODAS) is an aircraft-borne radiometer system suitable for light aircraft, which has applications for rapid measurement of chlorophyll pigment concentrations along the flight line. The instrument package includes a three channel radiometer system for upwelling radiance, an infrared temperature sensor, a three-channel downwelling irradiance sensor, and Loran-C navigation. Data are stored on a PC and processed to transects or interpolated 'images' on the ground. The instrument has been in operational use for two and one half years. The accuracy of pigment concentrations from the instrument is quite good, even in complex Chesapeake Bay waters. To help meet the requirement for validation of future satellite missions, a prototype air-deployable drifting buoy for measurement of near-surface upwelled radiance in multiple channnels is undergoing test deployment. The optical drifter burst samples radiance, stores and processes the data, and uses the Argos system as a data link. Studies are underway to explore the limits to useful lifetime with respect to power and fouling.

Esaias, W. E.↗

Composite structural materials

Progress is reported in studies of constituent materials composite materials, generic structural elements, processing science technology, and maintaining long-term structural integrity. Topics discussed include: mechanical properties of high performance carbon fibers; fatigue in composite materials; experimental and theoretical studies of moisture and temperature effects on the mechanical properties of graphite-epoxy laminates and neat resins; numerical investigations of the micromechanics of composite fracture; delamination failures of composite laminates; effect of notch size on composite laminates; improved beam theory for anisotropic materials; variation of resin properties through the thickness of cured samples; numerical analysis composite processing; heat treatment of metal matrix composites, and the RP-1 and RP2 gliders of the sailplane project.

Ansell, G. S.↗

Mars 2020 Rover Adaptive Caching Assembly: Caching Martian Samples for Potential Earth Return

The Adaptive Caching Assembly (ACA) is part of the Sampling and Caching System on the Mars 2020 Perseverance Rover, and consists of multiple stations that process, hermetically seal, and store sample tubes containing collected Martian material, either rock cores or regolith samples, in preparation for caching on the surface of Mars. The ACA stations consist of seven active degrees-of-freedom, as well as a large number of passive mechanisms that must operate in extreme Mars temperature and pressure conditions. A robotic arm within the Rover manipulates the sample tubes between ACA stations as part of an end-to-end sampling sequence, and utilizes a compliant end effector to accommodate misalignments during station interactions. Stringent hardware cleanliness requirements were dictated to ensure collected samples would not be compromised, which significantly impacted the design, assembly, and test operations of the ACA. Three ACAs were assembled to support ground testing and flight operations, which were exposed to environmental testing to validate functionality in Mars-like conditions. A number of challenges existed from design through test, including volume constraints, mechanism controllability and operation, the effects of tight tolerances, and cleanliness requirements.

Lin, Justin↗

Purification of Carbon Nanotubes: Alternative Methods

Traditional carbon nanotube purification process involves nitric acid refluxing and cross flow filtration using surfactant TritonX. This is believed to result in damage to nanotubes and surfactant residue on nanotube surface. Alternative purification procedures involving solvent extraction, thermal zone refining and nitric acid refiuxing are used in the current study. The effect of duration and type of solvent to dissolve impurities including fullerenes and P ACs (polyaromatic compounds) are monitored by nuclear magnetic reasonance, high performance liquid chromatography, and thermogravimetric analysis. Thermal zone refining yielded sample areas rich in nanotubes as seen by scanning electric microscopy. Refluxing in boiling nitric acid seem to improve the nanotube content. Different procedural steps are needed to purify samples produced by laser process compared to arc process. These alternative methods of nanotube purification will be presented along with results from supporting analytical techniques.

Files, Bradley↗

Design and Development of a Miniaturized Double Latching Solenoid Valve for the Sample Analysis at Mars Instrument Suite

The development of the in-house Miniaturized Double Latching Solenoid Valve, or Microvalve, for the Gas Processing System (GPS) of the Sample Analysis at Mars (SAM) instrument suite is described. The Microvalve is a double latching solenoid valve that actuates a pintle shaft axially to hermetically seal an orifice. The key requirements and the design innovations implemented to meet them are described.

Smith, James T.↗

Robotics System Process and Concept for On-orbit Assembly for Potential Mars Sample Return

Proposed Mars Sample Return (MSR) missions would require on-orbit assembly of containment vessels to meet backward Planetary Protection requirements and transfer of the sample container through various stations and positions. Some operations would have to be performed autonomously, and others would require ground-in-loop decision-making stages and verification processes. One concept design for an Earth Return Orbiter (ERO) Capture, Contain, and Return System (CCRS) Transfer Mechanism (TM) is a multi-Degree of Freedom (DOF) manipulator that utilizes a passive End Effector (EE) to assist in containment vessel assembly. To converge on a feasible design, a robotic system process has been instantiated. This process is composed of three main phases: robotic problem definition (operating environment, operations/functions, system goals), robotic solution selection (trade studies on the number of degrees of freedom, number of mechanisms, types of mechanisms), robotic solution design, implementation, and verification and validation (kinematic configuration, robotic and kinematic analysis and topology optimization of components). As a final product of this process, a half-scale functional prototype of the TM was developed to demonstrate the end-to-end operation capability.

Strahle, Jackson W↗

Lignin molecular weights of Populus trichocarpa residues after CELF pretreatment

Here we present a dataset of molecular weights of lignin from a woody energy crop (Populus trichocarpa) residues after a series of co-solvent enhanced lignocellulosic fractionation (CELF) pretreatment. The natural poplar variant GW-9947 from the Center for Bioenergy Innovation (CBI) was used. The poplar was knife milled and passed through a 1 mm sieve and CELF pretreatment was performed in a Parr autoclave reactor with 7.5 wt % solids loading, 0.5 wt% H2SO4 as catalyst at 150°C with various time. Tetrahydrofuran was added in a 1:1 mass ratio with water as the pretreatment solvent. Lignin was isolated from the pretreated samples after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 580 rpm for 2.5 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The solid residue was isolated by centrifugation and hydrolyzed again with freshly added buffer and enzymes for another 48 h. After filtration, the solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The lignin samples were then derivatized in an acetic anhydride/pyridine (1:1, v/v) mixture and stirred at room temperature for 24 h. Ethanol was added to the reaction mixture, left for 30 min and then removed with a rotary evaporator. The addition and removal of ethanol was repeated at least 3 times until all traces of acetic acid were removed. Acetylated lignin samples were then dissolved in tetrahydrofuran (THF) at a concentration of 1.0 mg/mL. The molecular weight of acetylated lignin was measured by a gel permeation chromatography (GPC) on a PSS-Polymer Standards Service (Warwick, RI, USA) GPC SECurity 1200 system featuring Agilent HPLC 1200 components equipped with four Waters Styragel columns (HR1, HR2, HR4 and HR6) and an UV detector (270 nm). Tetrahydrofuran was used as the mobile phase and flow rate was 0.3 mL/min. The Polymer Standards Service WinGPC Unity software (Build 6807) was used for data processing for all the samples. The data provides information about the effects of CELF pretreatment time at 150 ºC on lignin molecular weights.

09 BIOMASS FUELS↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of lunar ferromagnetic phases by the effective linewidth method

The effective line-width technique, first developed to study the physics of microwave relaxation in ferrites, has been successfully applied to lunar matter. Effective line-width measurements have been made on two selected samples containing disperse spherical metallic iron particles below 40 microns in diam. The data were obtained for fields from 7 to 12 kOe and a temperature range 125 - 300 K. The effective line width was field-independent and temperature-independent at 650 - 750 Oe. The high-field tails of the ferromagnetic resonance absorption were highly Lorentzian. From the relatively large and temperature-independent high-field effective line widths, it appears that (1) the metallic iron phases in lunar soil are rather impure; (2) the impurities are passive, in that there is no evidence for a temperature peak process; and (3) these samples contain no appreciable magnetite.

Patton, C. E.↗

Attempts to comprehend Martian surface processes through interpretation of the oxygen isotopic compositions of carbonates in SNC meteorites

The SNC meteorites are known to contain trace quantities of a variety of secondary minerals such as carbonates, sulfates, and aluminosilicates. Since these constituents are thought to be mostly preterrestrial in origin, their study has the potential to provide rigorous constraints on the nature of martian weathering processes. However, this line of investigation is potentially complicated by the presence within the meteorite samples of any additional weathering products produced by terrestrial processes. Examination of such terrestrial components is important since weathering processes that affect meteorite samples following their fall to Earth might have some bearing on the nature of analogous processes at the surface of Mars. It is obviously necessary to try and distinguish which secondary components in SNC meteorites are terrestrial in origin from those that are preterrestrial. Herein consideration is made of the stable isotopic compositions of weathering products in two SNC meteorites: EET A79001 (a sample collected from Antarctica) and Nakhla (a fall from Egypt, 1911).

Wright, I. P.↗

Recent Developments in Ultra High Temperature Ceramics at NASA Ames

NASA Ames is pursuing a variety of approaches to modify and control the microstructure of UHTCs with the goal of improving fracture toughness, oxidation resistance and controlling thermal conductivity. The overall goal is to produce materials that can perform reliably as sharp leading edges or nose tips in hypersonic reentry vehicles. Processing approaches include the use of preceramic polymers as the SiC source (as opposed to powder techniques), the addition of third phases to control grain growth and oxidation, and the use of processing techniques to produce high purity materials. Both hot pressing and field assisted sintering have been used to make UHTCs. Characterization of the mechanical and thermal properties of these materials is ongoing, as is arcjet testing to evaluate performance under simulated reentry conditions. The preceramic polymer approach has generated a microstructure in which elongated SiC grains grow in the form of an in-situ composite. This microstructure has the advantage of improving fracture toughness while potentially improving oxidation resistance by reducing the amount and interconnectivity of SiC in the material. Addition of third phases, such as Ir, results in a very fine-grained microstructure, even in hot-pressed samples. The results of processing and compositional changes on microstructure and properties are reported, along with selected arcjet results.

Johnson, Sylvia M.↗

Effect of Plutonium on Uranium Oxide Microstructural Fingerprint

The analysis of particulates from environmental sampling is routinely performed for nuclear forensics applications. In order to increase the tools available for nuclear forensics applications, capability development materials (CDMs), or reference particulates, are necessary for developing and benchmarking new analytical methods. Historically, these CDM particulates have been produced with highly controlled and characterized isotopic and size parameters for applications in developing and benchmarking particle sizers and mass spectrometry analytical methods [1- 4]. However, the development of CDMs with highly characterized particle morphology and phase of the particles is vital for aiding in the development and benchmarking of particle analytical methods for those parameters. In many cases, key properties such as crystallographic phase, morphology, and microstructure, may be correlated to processing history of environmental sampling particulates [5]. To that end, this work investigates determining the structural fingerprint of produced Pu-doped uranium oxide CDMs using transmission electron microscopy (TEM). The particulates, one of which shown in Figure 1, were synthesized to Fig. 1. Single particulate of uranium oxide fabricated using the THESEUS technique. develop capabilities for environmental sampling investigations. These particles are monodisperse at diameter of 1 μm and a range of plutonium concentrations from 0- 1,000 ppm. Given their small diameter, TEM analysis was ideal for studying the particulate structural fingerprint in detail. Previous investigations confirmed the external homogeneity of the particulates at different plutonium concentrations, however this analysis focuses on determining the grain structure, phase distribution, and porosity of the particulates.

Mayer, Jack [Univ. of Florida, Gainesville, FL (Un↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Gravitational influences on the liquid-state homogenization and solidification of aluminum antimonide

Typical commercial or laboratory-prepared samples of polycrystalline AlSb contain microstructural inhomogeneities of Al- or Sb-rich phases in addition to the primary AlSb grains. The paper reports on gravitational influences, such as density-driven convection or sedimentation, that cause microscopic phase separation and nonequilibrium conditions to exist in earth-based melts of AlSb. A triple-cavity electric furnace is used to homogenize the multiphase AlSb samples in space and on earth. A comparative characterization of identically processed low- and one-gravity samples of commercial AlSb reveals major improvements in the homogeneity of the low-gravity homogenized material.

Ang, C.-Y.↗

Workshop on Analysis of Returned Comet Nucleus Samples

This volume contains abstracts that were accepted by the Program Committee for presentation at the workshop on the analysis of returned comet nucleus samples held in Milpitas, California, January 16 to 18, 1989. The abstracts deal with the nature of cometary ices, cryogenic handling and sampling equipment, origin and composition of samples, and spectroscopic, thermal and chemical processing methods of cometary nuclei. Laboratory simulation experimental results on dust samples are reported. Some results obtained from Halley's comet are also included. Microanalytic techniques for examining trace elements of cometary particles, synchrotron x ray fluorescence and instrument neutron activation analysis (INAA), are presented.

Source record↗