Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Standard methods for filled hole tension testing of textile composites

The effects of two test specimen geometry parameters, the specimen width and W/D ratio, on filled-hole tensile strength were determined for textile composite materials. Test data generated by Boeing and Lockheed on 2-D and 3-D braids, and 3-D weaves were used to make these evaluations. The investigation indicated that filled-hole tensile-strength showed little sensitivity to either parameter. Test specimen configurations used in open-hole tension tests, such as those suggested by ASTM D5766 - Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates or those proposed by MIL-HDBK-17-lD should provide adequate results for material comparisons studies. Comparisons of the materials' open-hole and filled-hole tensile strengths indicated that the latter were generally lower than the former. The 3-D braids were the exception; their filled-hole strengths were unexpected larger than their open-hole strengths. However, these increases were small compared to the scatter in the data. Thus, filled hole tension may be a critical design consideration for textile composite materials.

Portanova, M. A.↗

Non-volatile magnetic random access memory

Improvements are made in a non-volatile magnetic random access memory. Such a memory is comprised of an array of unit cells, each having a Hall-effect sensor and a thin-film magnetic element made of material having an in-plane, uniaxial anisotropy and in-plane, bipolar remanent magnetization states. The Hall-effect sensor is made more sensitive by using a 1 m thick molecular beam epitaxy grown InAs layer on a silicon substrate by employing a GaAs/AlGaAs/InAlAs superlattice buffering layer. One improvement avoids current shunting problems of matrix architecture. Another improvement reduces the required magnetizing current for the micromagnets. Another improvement relates to the use of GaAs technology wherein high electron-mobility GaAs MESFETs provide faster switching times. Still another improvement relates to a method for configuring the invention as a three-dimensional random access memory.

Katti, Romney R.↗

Aligned Carbon Nanotube Tape for Sensor Applications

For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical properties CNT tape as a strain gauge in Structural Health Monitoring will provide an excellent material to embed within composite structures

Tucker, Dennis S.↗

PIA and REWIND: Two New Methodologies for Cross Section Adjustment

This paper presents two new cross section adjustment methodologies intended for coping with the problem of compensations. The first one PIA, Progressive Incremental Adjustment, gives priority to the utilization of experiments of elemental type (those sensitive to a specific cross section), following a definite hierarchy on which type of experiment to use. Once the adjustment is performed, both the new adjusted data and the new covariance matrix are kept. The second methodology is called REWIND (Ranking Experiments by Weighting for Improved Nuclear Data). This new proposed approach tries to establish a methodology for ranking experiments by looking at the potential gain they can produce in an adjustment. Practical applications for different adjustments illustrate the results of the two methodologies against the current one and show the potential improvement for reducing uncertainties in target reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Conversion of Resonance Parameters Between Wigner-Eisenbud R-matrix and Transition Matrix Pole Representation

The goal of this research is to develop a numerical code for translation between the current standard, Wigner-Eisenbud R-matrix parameters and a novel pole-representation of cross sections. The method follows Ducru et al. and constructs the conversion between these parametric representations of the scattering and reaction data. This pole representation, which expresses cross sections as a sum of simple poles (and their attendant residues), is examined in the context of the advantages provided by this compact, computationally efficient representation. These advantages include the ability to doppler broaden cross sections on-the-fly as well as a lower memory footprint when generating cross sections, an attractive feature to those interested in parallel GPU based Monte Carlo. Some conversion methods between R-matrix parameters and S-matrix poles have relied on curve fitting techniques. It is unknown weather these numerical methods necessarily preserve certain underlying physics properties of the standard R-matrix cross section model (such as unitarity). The direct conversion studied here aim to preserve such properties. This knowledge is of interest for future work into the generation of resonance parameter sensitivities.

CLUTCH↗

Performance evaluation of a high resolution dedicated breast PET scanner

Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance for its clinical use and shows an improved resolution and lesion detectability of small lesions compared to WB-PET.

60 APPLIED LIFE SCIENCES↗

True covariance simulation of the EUVE update filter

A covariance analysis of the performance and sensitivity of the attitude determination Extended Kalman Filter (EKF) used by the On Board Computer (OBC) of the Extreme Ultra Violet Explorer (EUVE) spacecraft is presented. The linearized dynamics and measurement equations of the error states are derived which constitute the truth model describing the real behavior of the systems involved. The design model used by the OBC EKF is then obtained by reducing the order of the truth model. The covariance matrix of the EKF which uses the reduced order model is not the correct covariance of the EKF estimation error. A true covariance analysis has to be carried out in order to evaluate the correct accuracy of the OBC generated estimates. The results of such analysis are presented which indicate both the performance and the sensitivity of the OBC EKF.

Bar-Itzhack, Itzhack Y.↗

Chemical crosslinking of acrylic acid to form biocompatible pH sensitive hydrogel reinforced with cellulose nanocrystals (CNC)

The purpose of this study is to produce a novel pH and temperature sensitive hydrogel, composed of poly(acrylic acid) (PAA) and cellulose nanocrystal (CNC). CNC was extracted from kenaf fiber through a series of alkali and bleaching treatments followed by acid hydrolysis. The PAA was then subjected to chemical cross-linking using the cross-linking agent (N,N-methylenebisacrylamide) with CNC entrapped in PAA matrix. The mixture was casted onto petri dish to obtain disc shape hydrogel. The effects of reaction conditions such as the ratio of PAA and CNC on the swelling behavior of the hydrogel obtained towards pH and temperature were studied. The obtained hydrogel was further subjected to different tests such swelling test for swelling behaviour at different pH and temperature along with scanning electron microscopy (SEM) for morphology analysis. The hydrogel obtained showed excellent pH sensitivity and obtained maximum swelling at pH 7. Besides that, hydrogel obtained showed significant increase in swelling ratio when temperature of swelling medium was increased from 25°C to 37°C. SEM micrograph showed that the pore size of the hydrogel decreases with increase of CNC content proving that the hydrogel structure became more rigid with addition of CNC. The PAA/CNC hydrogel with such excellent sensitivity towards pH and temperature can be developed further as drug carrier.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Study of jet shapes in inclusive jet production in pp collisions at √s=7 TeV using the ATLAS detector

Jet shapes have been measured in inclusive jet production in proton-proton collisions at s√=7 TeV using 3 pb⁻¹ of data recorded by the ATLAS experiment at the LHC. Jets are reconstructed using the anti-k t algorithm with transverse momentum 30 GeV T <600 GeV and rapidity in the region |y|<2.8. The data are corrected for detector effects and compared to several leading-order QCD matrix elements plus parton shower Monte Carlo predictions, including different sets of parameters tuned to model fragmentation processes and underlying event contributions in the final state. The measured jets become narrower with increasing jet transverse momentum and the jet shapes present a moderate jet rapidity dependence. Within QCD, the data test a variety of perturbative and nonperturbative effects. In particular, the data show sensitivity to the details of the parton shower, fragmentation, and underlying event models in the Monte Carlo generators. For an appropriate choice of the parameters used in these models, the data are well described.

Aad, G.↗

Sensitive Targeted Quantification of ERK Phosphorylation Dynamics and Stoichiometry in Human Cells without Affinity Enrichment

Mass spectrometry-based targeted quantification is a promising technology for site-specific quantification of posttranslational modifications (PTMs). However, a major constraint of most targeted MS approaches is the limited sensitivity for quantifying low-abundance PTMs, requiring the use of affinity reagents to enrich specific PTMs. Herein, we demonstrate the direct site-specific quantification of ERK phosphorylation isoforms (pT, pY, pTpY) and their relative stoichiometries using a highly sensitive targeted MS approach termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM). PRISM provides effective enrichment of target peptides within a given fraction from complex biological matrix with minimal sample losses, followed by selected reaction monitoring (SRM) quantification. The PRISM-SRM approach enabled direct quantification of ERK phosphorylation in human mammary epithelial cells (HMEC) from as little as 25 µg tryptic peptides from whole cell lysates. Compared to immobilized metal-ion affinity chromatography, PRISM provided >10-fold improvement in signal intensities, presumably due to the better peptide recovery of PRISM for handling small size samples. This approach was applied to quantify ERK phosphorylation dynamics in HMEC treated by different doses of EGF at both the peak activation (10 min) and steady state (2 h). At 10 min, the maximal ERK activation was observed with 0.3 ng/mL dose, whereas the maximal steady state level of ERK activation at 2 h was at 3 ng/ml dose, corresponding to 1200 and 9000 occupied receptors, respectively. At 10 min, the maximally activated pTpY isoform represented ~40% of total ERK, falling to less than 10% at 2 h. The time course and dose-response profiles of individual phosphorylated ERK isoforms indicated that singly phosphorylated pT-ERK never increases significantly, while the increase of pY-ERK paralleled that of pTpY-ERK. This data supports for a processive, rather than distributed, model of ERK phosphorylation. The PRISM-SRM quantification of protein phosphorylation illustrates the potential for simultaneous quantification of multiple PTMs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

KINETIC STUDY OF AGING IN A URANIUM-TITANIUM EUTECTOID ALLOY USING THERMOELECTRIC POWER MEASUREMENT

Considerable attention has been given to the study of microstructure evolution and mechanical properties of dilute U-Ti alloys. A typical procedure of heat treatment of the eutectoid uranium-titanium alloy consists of solution treatment in the {gamma} phase, obtaining of soft {alpha}{sup '} martensitic metastable structure by water quenching to room temperature and precipitation hardening by aging at 300-550 deg. C. Depending on employed temperature and time the aging results in GP zone formation through the precipitation reaction {alpha}{sup '}{yields}{alpha}+{delta}. The {delta} phase is a hexagonal U{sub 2}Ti intermetallic compound, responsible for the significant increase in the level of the micro-strain in the metastable {alpha}{sup '} matrix. Thermoelectric power (TEP) measurements have recently gained a growing attention for the characterization of metallurgical properties in steels and other alloys. These measurements, which are based on the Seebeck effect, are sensitive to changes in the electronic structure of the material as result of various metallurgical processes. In the current research, TEP measurement technique was applied as a non destructive assessment technique to characterize the aging kinetics of the quenched uranium-titanium binary alloy. Good correlation has been found between measured TEP, micro-strain evolution, as obtained by using XRD, and hardness values at different heat treatment stages. A reasonable explanation of the correlation between the crystallography changes, micro-strain, TEP measurements and properties is presented.

36 MATERIALS SCIENCE↗

Electronic-Excitation Energy Transfer between Dye Molecules Adsorbed in One-Dimensional Photonic Crystals

Electronic-excitation energy transfer between molecules of Coumarin 7 (donor) and Rhodamine B (acceptor) have been experimentally investigated in one-dimensional photonic crystals based on oxidized mesoporous silicon and in a similar matrix, which does not possess the properties of a photonic crystal. The efficiencies of excitation transfer between donor and acceptor molecules have been determined based on the donor-fluorescence quenching and sensitized acceptor luminescence. It is established that the efficiency of electronic-excitation energy transfer in a photonic crystal increases in comparison with that for porous silicon.

74 ATOMIC AND MOLECULAR PHYSICS↗

An information matrix approach for aircraft parameter-insensitive control

The Fisher Information Matrix provides the nucleus of a design procedure for obtaining parameter-insensitive feedback gains in Linear-Quadratic-Gaussian problems. The procedure minimizes a sum of performance and closed-loop sensitivity costs, the latter being related to the information content of the system response. Analytical expressions for the appended cost functional and its gradient with respect to the feedback gains are derived. These derivatives serve as the basis of a computationally efficient iterative algorithm that finds the optimal gains. Application of the technique is made to determine low sensitivity feedback gains for a C-5A wing loading alleviation system that has 15 states and three uncertain parameters.

Kleinman, D. L.↗

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

The ND280 Near Detector of the T2K Experiment

The T2K experiment is a long-baseline neutrino oscillations experiment, designed to improve the sensitivity to {theta}{sub 13} by at least one order of magnitude and to determine more accurately the 'atmospheric' parameters {theta}{sub 23} and {delta}m{sub 23}{sup 2}. For this purpose a high intensity v{sub {mu}} beam ({approx}700 MeV peak energy) produced at the JPARC accelerator complex will be directed towards the Super-Kamiokande (SK) detector, at a distance of 295 km. A near detector complex (ND280) is also under construction at 280 m from the production target. The ND280 apparatus is designed to measure the energy spectrum, flavor content and neutral and charged current interaction rates of the un-oscillated neutrino beam; this information will be used to predict the un-oscillated interaction rates at Super-Kamiokande. In this talk the physics goals of T2K will be introduced and the role of the ND280 detector in the T2K analysis strategy will be discussed. The ND280 detector is presently under construction, and first neutrino interaction data are expected at the end of this year. The design, expected performance and test-beam studies of the ND280 sub-detectors will be described briefly, together with time scales for construction and initial operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A scintillating fission detector for neutron flux measurements

Neutron flux monitors are commonly used for a variety of nuclear physics applications. A scintillating neutron detector, consisting of a liquid scintillator loaded with fissionable material, has been developed, characterized, and tested in the beam line at the Los Alamos Neutron Science Center, and shows a significant improvement in neutron sensitivity compared with a conventional fission chamber. Recent research on nanocomposite-based scintillators for gamma-ray detection indicates that this approach can be extended to load nanoparticles of fissionable material into a scintillating matrix, with up to three orders of magnitude higher loading than typical fission chambers. This will result in a rugged, cost-efficient detector with high efficiency, a short signal rise time, and the ability to be used in low neutron-flux environments. Initial efforts to utilize the luminescence of uranyl oxide to eliminate the need for wavelength-shifting dyes were unsuccessful. Excitation of uranyl compounds has been reported at wavelengths ranging from 266 nm to 532 nm. However, neither the 300 nm emission of toluene, nor the 350 nm emission of PPO, nor the 410 nm emission of POPOP resulted in significant excitation of and emission by uranyl oxide. As indicated by UV/visible spectroscopy, light emitted at these wavelengths was absorbed by the colored solution. {sup 235}U remains the most attractive candidate for a fissionable scintillator, due to its high fission cross-section and lack of a threshold fission energy, but all solutions containing molecular uranium compounds will be colored, most more highly than the U{sup 6+} compounds used here. Research is therefore continuing toward the fabrication of uranium nanoparticles, in which, due to Rayleigh scattering, the coloration should be less pronounced. The characterization of the thorium-loaded liquid scintillator and the fabrication of the 100 mL detectors for use at LANSCE demonstrated the feasibility of loading fissionable material into a liquid scintillator. Analysis of beam line experiments using the thorium-loaded scintillator is underway to determine the fission event rate in the detector, for comparison with a conventional fission chamber as well as with an unloaded liquid scintillator.

36 MATERIALS SCIENCE↗

Strain rate effects on the mechanical behavior of porous titanium with different pore sizes

High strain-rate (up to 6600 s –1 ) and quasi-static compression tests are conducted on a powder-sintered porous titanium with different pore sizes (mean: 30 μm and 120 μm). In situ X-ray imaging is implemented to characterize the pores-scale deformation dynamics. The yield strength as a function of strain rate exhibits two stages of rate sensitivity, and the transition occurs at 1600 s –1 . X-ray images show that pore compaction and strain localizations occur preferentially at pores oriented perpendicular to the loading direction under quasi-static loading, but become more random under high strain-rate loading as a result of higher driving force and plastic deformation nucleation rate. Here, the more homogeneous nucleation of plastic deformation contributes to the increased rate sensitivity beyond 1600 s –1 . At the same strain rate, the yield strength of porous Ti as well as strain field homogeneity decreases significantly with increasing pore size. The small pore spacing in fine-pored Ti reduces the degree of stress concentrations around pores. Therefore, the higher stress concentrations in coarse-pored Ti lead to an earlier yield of matrix around pores and thus a lower bulk yield strength.

36 MATERIALS SCIENCE↗