Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Thermal Characterization of a Direct Gain Solar Thermal Engine

A thermal/fluids analysis of a direct gain solar thermal upper stage engine is presented and the results are discussed. The engine has been designed and constructed at the NASA Marshall Space Flight Center for ground testing in a facility that can provide about 10 kilowatts of concentrated solar energy to the engine. The engine transfers that energy to a coolant (hydrogen) that is heated and accelerated through a nozzle to produce thrust. For the nominal design values and a hydrogen flowrate of 2 lb/hr., the results of the analysis show that the hydrogen temperature in the chamber (nozzle entrance) reaches about 3800 F after 30 minutes of heating and about 3850 F at steady-state (slightly below the desired design temperature of about 4100 F). Sensitivity analyses showed these results to be relatively insensitive to the values used for the absorber surface infrared emissivity and the convection coefficient within the cooling ducts but very sensitive to the hydrogen flowrate. Decreasing the hydrogen flowrate to 1 lb/hr. increases the hydrogen steady-state chamber temperature to about 4700 F, but also causes an undesirable decrease in thrust.

Alexander, Reginald A.↗

Thermal Characterization of a Direct Gain Solar Thermal Engine

A thermal/fluids analysis of a direct gain solar thermal upper stage engine is presented and the results are discussed. The engine was designed and constructed at the NASA Marshall Space Flight Center for ground testing in a facility that can provide about 10 kilowatts of concentrated solar energy to the engine. The engine transfers energy to a coolant (hydrogen) that is heated and accelerated through a nozzle to produce thrust. For the nominal design values and a hydrogen flowrate of 2 lb./hr., the results of the analysis show that the hydrogen temperature in the chamber (nozzle entrance) reaches about 3800 F after 30 minutes of heating and about 3850 F at steady-state (slightly below the desired design temperature of about 4100 F. Sensitivity analyses showed these results to be relatively insensitive to the values used for the absorber surface infrared emissivity and the convection coefficient within the cooling ducts but very sensitive to the hydrogen flowrate. Decreasing the hydrogen flowrate to 1 lb./hr. increases the hydrogen steady-state chamber temperature to about 4700 F, but also of course causes a decrease in thrust.

Alexander, Reginald A.↗

Finite element analysis of thermal distortion effects on optical performance of solar dynamic concentrator for Space Station Freedom

An analysis was performed to predict the thermal distortion of the solar dynamic concentrator for Space Station Freedom in low earth orbit and to evaluate the effects of that thermal distortion on concentrator on-orbit performance. The analysis required substructural finite element modeling of critical concentrator structural subsystems, structural finite element modeling of the concentrator, mapping of thermal loading onto the structural finite element model, and the creation of specialized postprocessors to assist in interpreting results. Concentrator temperature distributions and thermally induced displacements and slope errors and the resulting receiver flux distribution profiles are discussed. Results determined for a typical orbit indicate that concentrator facet rotations are less than 0.2 mrad and that the change in facet radius due to thermal flattening is less than 5 percent. The predicted power loss due to thermal distortion effects is less than 0.3 percent. As a consequence the thermal distortions of the solar dynamic concentrator in low earth orbit will have a negligible effect on the flux distribution profiles within the receiver.

Doherty, Michael P.↗

Cosmic ray density gradient and its dependence on the north-south asymmetry in solar activity

An analysis of the diurnal anisotropy on geomagnetically quiet days was performed using neutron monitor data at Deep River, Leeds, Rome and Tokyo, well distributed in latitude and longitude for the period 1964-79. The days were separated according to the polarity of IMF on that day. A significant difference in the amplitude and phase was found on towards and away polarity days, particularly during the years of high solar activity and large north-south asymmetry. These results (particularly time of maximum) on geomagnetically quiet days show some better relationship to the expected results as compared to the results obtained using all the days in a year.

BADRUDDIN↗

Solar energy system economic evaluation: IBM System 2, Togus, Maine

The economic analysis of the solar energy system, is developed for Torgus and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f-chart design procedure with inputs taken on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over a projected twenty year life, life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results demonstrate that the solar energy system is economically viable at all of the five sites for which the analysis was conducted.

Source record↗

Solar electric geocentric transfer with attitude constraints: Analysis

A time optimal or nearly time optimal trajectory program was developed for solar electric geocentric transfer with or without attitude constraints and with an optional initial high thrust stage. The method of averaging reduces computation time. A nonsingular set of orbital elements is used. The constraints, which are those of one of the SERT-C designs, introduce complexities into the analysis and the solution yields possible discontinuous changes in thrust direction. The power degradation due to VanAllen radiation is modeled analytically. A wide range of solar cell characteristics is assumed. Effects such as oblateness and shadowing are included. The analysis and the results of many example runs are included.

Sackett, L. L.↗

Summary of process research analysis efforts

A summary of solar-cell process research analysis efforts was presented. Process design and cell design are interactive efforts where technology from integrated circuit processes and other processes are blended. The primary factors that control cell efficiency are: (1) the bulk parameters of the available sheet material, (2) the retention and enhancement of these bulk parameters, and (3) the cell design and the cost to produce versus the finished cells performance. The process sequences need to be tailored to be compatible with the sheet form, the cell shape form, and the processing equipment. New process options that require further evaluation and utilization are lasers, robotics, thermal pulse techniques, and new materials. There are numerous process control techniques that can be adapted and used that will improve product uniformity and reduced costs. Two factors that can lead to longer life modules are the use of solar cell diffusion barriers and improved encapsulation.

Burger, D. R.↗

Interaction of Comets and the Solar Wind

The analysis of Comet Kudo-Fujikawa at perihelion was published and picked up by Der Spiegel. Besides a large and rapidly increasing water outgassing rate, we detected a bright tail in doubly ionized carbon. The amount of carbon was greater than could be accounted for by CO photodissociation, and we attribute it to evaporation of organics from dust. A spectacular disconnection event was apparent in the C III tail, and it coincides within the uncertainties to the position of the heliospheric current sheet. The analysis of the sungrazing comet C2001 C2 is in press. It showed evidence for subfragments and for a very long lasting source of neutrals, which we identify as evaporation of pyroxene dust grains. Results were also presented at COSPAR. We are working on observations of another sungrazer, comet C2002 S2, which shows a sudden 2 magnitude drop in optical brightness and an equally sudden recovery. UVCS observations during that time show a steadily increasing outgassing rate. We have derived solar wind densities for both comets, but we are still sorting out the ambiguities involving the fragmentation and optical behavior.

Wagner, William↗

The relationship between solar flares and solar sector boundaries

A superposed epoch analysis of 1964-1970 solar flares shows a marked increase in flare occurrence within a day of (-+) solar sector boundaries, as well as a local minimum in flare occurrence near (+-) sector boundaries. This perference for (-+) boundaries is more noticeable for Northern Hemisphere flares, where these polarities match the Hale polarity law, but is not reversed in the south. Plage regions do not show such a perference.

Dittmer, P. H.↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

Modeling of thruster and solar array characteristics in the JPL low-thrust trajectory analysis

Recent advances in thruster and solar array technology have resulted in the possibility of performing many high energy space missions previously considered infeasible. This capability was demonstrated by an extensive study last year of a comet Halley rendezvous mission. In order to perform this extremely high energy mission, several advanced concepts in electric propulsion technology were investigated; notably the use of very high power, lightweight solar arrays which directly powered the beam supply of the electric propulsion thrusters, and the use of solar concentrators on the arrays together with conventional thrusters and power processors. These technology advances have directly impacted the modeling of the solar arrays and thrusters in the programs used in generating low-thrust trajectories. The intent of this paper is to discuss the modeling of the solar arrays and thrusters as employed in the trajectory programs presently being used in low-thrust mission studies at JPL.

Sauer, C. G., Jr.↗

Mission analysis for earth atmospheric measurements using solar occultation experiments on Shuttle Spacelabs

The maximum geographical coverage of solar occultation experiments for various Shuttle-Spacelab mission concepts is defined and an analysis that includes trade-offs between parameters such as launch time, season, orbital inclination and altitude is presented as well as the mission design data for the Spacelab-3 flight. The effects of orbital ranges from 220 to 600 km on geographical coverage are examined with inclinations up to 97 deg for sun-synchronous orbit. Results show that the widest band of latitude coverage in the tropics and the temperate zones can be achieved with a mid-inclined (i.e., 57 deg) orbit and a mid-morning or late-night launch time.

Harrison, E. F.↗

The Prolate Solar Chromosphere

We present a comparative analysis of the chromospheric solar limb prolateness, using strictly simultaneous H-alpha, ground-based observations and HeII space-based observations. The typical prolateness is found to be DeltaD/D = 5.5 x 10(exp -3) in HeII and 1.2 x 10(exp -3) in H-alpha. The first measurements in the 30.4 nm HeII line over a period of two years. as well as coronal data, are discussed to explore further the origin of the prolateness and its possible consequences.

Auchere, F.↗

2009 Technical Risk and Uncertainty Analysis of the U.S. Department of Energy's Solar Energy Technologies Program Concentrating Solar Power and Photovoltaics R&D

The U.S. Department of Energy (DOE) Solar Energy Technologies Program (SETP) conducted a 2009 Technical Risk and Uncertainty Analysis to better assess its cost goals for concentrating solar power (CSP) and photovoltaic (PV) systems, and to potentially rebalance its R&D portfolio. This report details the methodology, schedule, and results of this technical risk and uncertainty analysis.

14 SOLAR ENERGY↗

Analyzing Solar-Power Options For Spacecraft

Solar Space Power Analysis Code, SOSPAC, developed to examine solar-thermal and photovoltaic power-generation options available for satellite or spacecraft in low orbit around Earth. Is software tool for preliminary analysis of systems and enables engineer to compare areas, weights, and costs of several candidate electric- and thermal-power systems. Configurations studied include photovoltaic arrays and paraboloidal-dish systems to produce electricity only and in various combinations to provide both thermal and electric power. Written in FORTRAN IV.

Selcuk, M. K.↗

Rankine engine solar power generation. I - Performance and economic analysis

Results of a computer simulation of the performance of a solar flat plate collector powered electrical generation system are presented. The simulation was configured to include locations in New Mexico, North Dakota, Tennessee, and Massachusetts, and considered a water-based heat-transfer fluid collector system with storage. The collectors also powered a Rankine-cycle boiler filled with a low temperature working fluid. The generator was considered to be run only when excess solar heat and full storage would otherwise require heat purging through the collectors. All power was directed into the utility grid. The solar powered generator unit addition was found to be dependent on site location and collector area, and reduced the effective solar cost with collector areas greater than 400-670 sq m. The sites were economically ranked, best to worst: New Mexico, North Dakota, Massachusetts, and Tennessee.

Gossler, A. A.↗