Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

HIGH-RESOLUTION IMAGES OF ORBITAL MOTION IN THE ORION TRAPEZIUM CLUSTER WITH THE LBT AO SYSTEM

The new 8.4 m LBT adaptive secondary AO system, with its novel pyramid wavefront sensor, was used to produce very high Strehl ({approx}> 75% at 2.16 {mu}m) near-infrared narrowband (Br{gamma}: 2.16 {mu}m and [Fe II]: 1.64 {mu}m) images of 47 young ({approx}1 Myr) Orion Trapezium {theta}{sup 1} Ori cluster members. The inner {approx}41 Multiplication-Sign 53'' of the cluster was imaged at spatial resolutions of {approx}0.''050 (at 1.64 {mu}m). A combination of high spatial resolution and high S/N yielded relative binary positions to {approx}0.5 mas accuracies. Including previous speckle data, we analyze a 15 year baseline of high-resolution observations of this cluster. We are now sensitive to relative proper motions of just {approx}0.3 mas yr{sup -1} (0.6 km s{sup -1} at 450 pc); this is a {approx}7 Multiplication-Sign improvement in orbital velocity accuracy compared to previous efforts. We now detect clear orbital motions in the {theta}{sup 1} Ori B{sub 2} B{sub 3} system of 4.9 {+-} 0.3 km s{sup -1} and 7.2 {+-} 0.8 km s{sup -1} in the {theta}{sup 1} Ori A{sub 1} A{sub 2} system (with correlations of P.A. versus time at >99% confidence). All five members of the {theta}{sup 1} Ori B system appear likely a gravitationally bound 'mini-cluster'. The very lowest mass member of the {theta}{sup 1} Ori B system (B{sub 4}; mass {approx}0.2 M{sub Sun }) has, for the first time, a clearly detected motion (at 4.3 {+-} 2.0 km s{sup -1}; correlation = 99.7%) w.r.t. B{sub 1}. However, B{sub 4} is most likely in a long-term unstable (non-hierarchical) orbit and may 'soon' be ejected from this 'mini-cluster'. This 'ejection' process could play a major role in the formation of low-mass stars and brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulations of Precipitation Using NRCM and Comparisons with Satellite Observations and CAM: Annual Cycle

The accurate representation of rainfall in models of global climate has been a challenging task for climate modelers owing to its small space and time scales. Quantifying this variability is important for comparing simulations of atmospheric behavior with real time observations. In this regard, this paper compares both the statistical and dynamically forced aspects of precipitation variability simulated by the high-resolution (36 km) Nested Regional Climate Model (NRCM), with satellite observations from the Tropical Rainfall Measuring Mission (TRMM) 3B42 dataset and simulations from the Community Atmosphere Model (CAM) at T85 spatial resolution. Six years of rainfall rate data (2000-2005) from within the Tropics (30"S-30"N) have been used in the analysis and results are presented in terms of long-term mean rain rates, amplitude and phase of the annual cycle and seasonal mean maps of precipitation. Our primary focus is on characterizing the annual cycle of rainfall over four land regions of the Tropics namely, the Indian Monsoon, the Amazon, Tropical Africa and the North American monsoon. The lower tropospheric circulation patterns are analyzed in both the observations and the models to identify possible causes for biases in the simulated precipitation. The 6-year mean precipitation simulated by both models show substantial biases throughout the global Tropics with NRCM/CAM systematically underestimating/overestimating rainfall almost everywhere. The seasonal march of rainfall across the equator, following the motion of the sun, is clearly seen in the harmonic vector maps. The timing of peak rainfall (phase) produced by NRCM is in closer agreement with the observations compared to CAM. However like the longtime mean, the magnitude of seasonal mean rainfall is greatly underestimated by NRCM throughout the Tropical land mass. Some of these regional biases can be attributed to erroneous circulation and moisture surpluses/deficits in the lower troposphere in both models. Overall, the results seem to indicate that employing a higher spatial resolution (36 km) does not significantly improve simulation of precipitation. We speculate that a combination of several physics parameterizations and lack of model tuning gives rise to the observed differences between NRCM and the observations.

54 ENVIRONMENTAL SCIENCES↗

Application of spherical diodes for megavoltage photon beams dosimetry

Purpose: External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A high uniformity in angular response is also a very important feature in a detector, because it has to measure radiation coming from all the directions of the space. It is also convenient that detectors are inexpensive and robust, especially to performin vivo measurements. The purpose of this work is to introduce a new detector for measuring megavoltage photon beams and to assess its performance to measure relative dose in EBRT. Methods: The detector studied in this work was designed as a spherical photodiode (1.8 mm in diameter). The change in response of the spherical diodes is measured regarding the angle of incidence, cumulated irradiation, and instantaneous dose rate (or dose per pulse). Additionally, total scatter factors for large and small fields (between 1 × 1 cm{sup 2} and 20 × 20 cm{sup 2}) are evaluated and compared with the results obtained from some commercially available ionization chambers and planar diodes. Additionally, the over-response to low energy scattered photons in large fields is investigated using a shielding layer. Results: The spherical diode studied in this work produces a high signal (150 nC/Gy for photons of nominal energy of 15 MV and 160 for 6 MV, after 12 kGy) and its angular dependence is lower than that of planar diodes: less than 5% between maximum and minimum in all directions, and 2% around one of the axis. It also has a moderated variation with accumulated dose (about 1.5%/kGy for 15 MV photons and 0.7%/kGy for 6 MV, after 12 kGy) and a low variation with dose per pulse (±0.4%), and its behavior is similar to commercial diodes in total scatter factor measurements. Conclusions: The measurements of relative dose using the spherical diode described in this work show its feasibility for the dosimetry of megavoltage photon beams. A particularly important feature is its good angular response in the MV range. They would be good candidates forin vivo dosimetry, and quality assurance of VMAT and tomotherapy, and other modalities with beams irradiating from multiple orientations, such as Cyberknife and ViewRay, with minor modifications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Virtual strain gage size study

DIC is a non-linear low-pass spatial filtering operation; whether we consider the effect of the subset and shape function, the strain window used in the strain calculation, of other post-processing of the results, each decision will impact the spatial resolution, of the measurement. More fundamentally, the speckle size limits, the spatial resolution by dictating the smallest possible subset. After this decision the processing settings are controlled by the allowable noise level balanced by possible bias errors created by the data filtering. This article describes a process to determine optimum DIC software settings to determine if the peak displacements or strains are being found.

97 MATHEMATICS AND COMPUTING↗

3D Millimeter Event Localization in Bulk Scintillator Crystals

One of the primary goals of scintillator-based gamma-ray detector development is to obtain spatial resolutions in bulk crystals at the millimeter level in all three spatial dimensions. An even more challenging goal is to disentangle multiple simultaneous energy depositions with comparable spatial resolutions. We are exploring a new technique to achieve this level of performance through the use of close-coupled, coded-aperture shadow masks placed between the crystal and a position-sensitive phototransducer. We report on simulations of such a device using Monte Carlo light transport simulations performed with GEANT4. Initial indications are promising; however, the technique will require a very high level of performance from the phototransducer.

Ziock, Klaus-Peter↗

First evaluation of the tracking performance of the ARCADIA Fully Depleted MAPS with 120 GeV proton beam

This work presents test beam characterization of the ARCADIA Main Demonstrator 3, a 200 $μ$m thick Fully Depleted MAPS developed using a custom LFoundry 110 nm CIS process on a high-resistivity substrate. Measurements using a 120 GeV proton beam demonstrate a detection efficiency exceeding 99% and a spatial resolution down to 3.8 $μ$m. The study evaluates cluster size, spatial resolution, and efficiency as a function of the threshold, front-end currents, and backside bias voltage.

Rignanese, M. [Padua U.; INFN, Padua]↗

Lattice Parameter Local Determination for Trigonal, Hexagonal, and Tetragonal Crystal Systems Using Several Coplanar X-Ray Reflections

The method for determining the local lattice parameters using quasi-multiple X-ray diffraction (which was proposed and used only for crystals of the cubic system) has been expanded to measure the local crystal lattice parameters for the trigonal, hexagonal, and tetragonal systems. Local variations in the lattice parameters in the tetragonal paratellurite (TeO{sub 2}) and trigonal lanthanum-gallium tantalate (La{sub 3}Ga{sub 5.5}Ta{sub 0.5}O{sub 14}) crystals have been investigated. Reflections necessary for implementing the quasi-multiple X-ray diffraction scheme are found for these crystals. The pairs of reflections that were found were used to complete quasi-multiple X-ray diffraction schemes on a laboratory X-ray source and determine the variation in the lattice parameter a along the surface of these crystals. The relative measurement error was 4 x 10{sup -6} at a spatial resolution of 140 {mu}m. The accuracy of the method and the parameters determining this characteristic were analyzed based on the results. The locality of the method and the limits of the spatial resolution of an X-ray diffraction measurement of lattice parameters are estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Relationship between High-energy X-Ray Sources and Photospheric and Helioseismic Impacts of X1.8 Solar Flare of 2012 October 23

The X-class solar flare of 2012 October 23 generated continuum photospheric emission and a strong helioseismic wave (“sunquake”) that points to an intensive energy release in the dense part of the solar atmosphere. We study properties of the energy release with high temporal and spatial resolutions, using photospheric data from the Helioseismic Magnetic Imager (HMI) on board Solar Dynamics Observatory , and hard X-ray observations made by RHESSI . For this analysis we use level-1 HMI data (filtergrams), obtained by scanning the Fe i line (6731 Å) with the time cadence of ∼3.6 s and spatial resolution of ∼0.″5 per pixel. It is found that the photospheric disturbances caused by the flare spatially coincide with the region of hard X-ray emission but are delayed by ≲4 s. This delay is consistent with predictions of the flare hydrodynamics RADYN models. However, the models fail to explain the magnitude of variations observed by the HMI. The data indicate that the photospheric impact and helioseismic wave might be caused by the electron energy flux, which is substantially higher than that in the current flare radiative hydrodynamic models.

79 ASTRONOMY AND ASTROPHYSICS↗

Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Satellite NO{sub 2} Observations with High Resolution Model Simulations over the Balkan Peninsula

High resolution model estimations of tropospheric NO{sub 2} column amounts from the Comprehensive Air Quality Model (CAMx) were simulated for the Balkan Peninsula and were compared with satellite data for a period of one year, in order to study the characteristics of the spatial and temporal variability of pollution in the area. The Balkan area is considered a crossroad of different pollution sources and therefore has been divided in urban, industrial and rural regions, aiming to investigate the consistency of satellite retrievals and model predictions at high spatial resolution. Satellite measurements of tropospheric NO{sub 2} are available daily at 13:30 LT since 2004 from OMI/Aura with a resolution of 13x24 km. The anthropogenic emissions used in CAMx for the domain under study, was compiled employing bottom-up approaches (road transport sector, off-road machinery) as well as other national registries and international databases. High resolution GIS maps (road network, landuses, population) were also used in order to achieve high spatial resolution. In most of the cases the model reveals similar spatial patterns with the satellite data, while over certain areas discrepancies were found and investigated.

54 ENVIRONMENTAL SCIENCES↗

First evaluation of fast neutron imaging with LiInSe 2 semiconductors

Fast neutron imaging is a powerful tool to investigate elemental/isotopic compositions of objects, supporting both scientific studies as well as cargo scanning. Current neutron imaging systems are faced with challenges associated with timing, detection efficiency, and/or spatial resolution. Here, we report on the use of a semiconducting lithium indium diselenide neutron sensor coupled to a Timepix ASIC for fast neutron imaging. Using a 15 cm thick copper knife edge, the spatial resolution of the neutron imager was found to be 1.55 mm for 9 MeV neutrons. In conclusion, the experimental detection efficiency at 9 MeV was in general agreement with calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVIDENCE FOR CLOUD-CLOUD COLLISION AND PARSEC-SCALE STELLAR FEEDBACK WITHIN THE L1641-N REGION

We present high spatial resolution {sup 12}CO (J = 1-0) images taken by the Nobeyama 45 m telescope toward a 48' Multiplication-Sign 48' area, including the L1641-N cluster. The effective spatial resolution of the maps is 21'', corresponding to 0.04 pc at a distance of 400 pc. A recent 1.1 mm dust continuum map reveals that the dense gas is concentrated in several thin filaments. We find that a few dust filaments are located at the parts where {sup 12}CO (J = 1-0) emission drops sharply. Furthermore, the filaments have two components with different velocities. The velocity difference between the two components is about 3 km s{sup -1}, corresponding to a Mach number of 10, significantly larger than the local turbulent velocity in the cloud. These facts imply that the collision of the two components (hereafter, the cloud-cloud collision) possibly contributed to the formation of these filaments. Since the two components appear to overlap toward the filaments on the plane of the sky, the collision may have occurred almost along the line of sight. Star formation in the L1641-N cluster was probably triggered by such a collision. We also find several parsec-scale CO shells whose centers are close to either the L1641-N cluster or the V 380 Ori cluster. We propose that these shells were created by multiple winds and/or outflows from cluster young stellar objects, i.e., 'protocluster winds'. One exceptional dust filament located at the western cloud edge lies along a shell; it is presumably part of the expanding shell. Both the cloud-cloud collision and protocluster winds are likely to influence the cloud structure and kinematics in this region.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of convergent collimators for pixelated SPECT systems

Purpose: The optimization of the collimator design is essential to obtain the best possible sensitivity in single photon emission computed tomography imaging. The aim of this work is to present a methodology for maximizing the sensitivity of convergent collimators, specifically designed to match the pitch of pixelated detectors, for a fixed spatial resolution value and to present some initial results using this approach. Methods: Given the matched constraint, the optimal collimator design cannot be simply found by allowing the highest level of septal penetration and spatial resolution consistent with the imposed restrictions, as it is done for the optimization of conventional collimators. Therefore, an algorithm that interactively calculates the collimator dimensions, with the maximum sensitivity, which respect the imposed restrictions was developed and used to optimize cone and fan beam collimators with tapered square-shaped holes for low (60-300 keV) and high energy radiation (300-511 keV). The optimal collimator dimensions were locally calculated based on the premise that each hole and septa of the convergent collimator should locally resemble an appropriate optimal matched parallel collimator. Results: The optimal collimator dimensions, calculated for subcentimeter resolutions (3 and 7.5 mm), common pixel sizes (1.6, 2.1, and 2.5 mm), and acceptable septal penetration at 140 keV, were approximately constant throughout the collimator, despite their different hole incidence angles. By using these input parameters and a less strict septal penetration value of 5%, the optimal collimator dimensions and the corresponding mass per detector area were calculated for 511 keV. It is shown that a low value of focal distance leads to improvements in the average sensitivity at a fixed source-collimator distance and resolution. The optimal cone beam performance outperformed that of other optimal collimation geometries (fan and parallel beam) in imaging objects close to the collimator surface. Conclusions: These results demonstrate the potential of this kind of optimal convergent collimators for the use in small field of view imaging applications.

43 PARTICLE ACCELERATORS↗

Conversions between gas-phase metallicities in MaNGA

ABSTRACT We present polynomial conversions between each of 11 different strong line gas-phase metallicity calibrations, each based on ∼1.1 million star-forming spaxels in the public Sloan Digital Sky Survey (SDSS) Data Release 15 (DR15) Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. For this sample, which is ∼20 times larger than previous works, we present fifth-order polynomial fits for each of 110 possible calibration conversions, for both Small Magellanic Cloud-type and Milky Way-type dust corrections. The typical 2σ scatter around our polynomial fits is 0.1 dex; we present the range over which the metallicities are valid. Conversions between metallicities which rely on the same set of line ratios, or a heavily shared set of emission lines, have reduced scatter in their conversions relative to those conversions with little overlap in required emission lines. Calibration conversions with less consistent sets of emission lines also have increased galaxy-to-galaxy variability, and this variability can account for up to 35 per cent of the total scatter. We also compare our conversions to previous work with the single fibre SDSS DR7 spectra along with higher spatial resolution data from the TYPHOON Integral Field Spectroscopy survey, resulting in comparison samples with spatial resolutions from several kpc down to ∼100 pc. Our metallicity conversions, obtained with the large sample of MaNGA, are robust against the influence of diffuse ionized gas, redshift, effective radius, and spatial blurring, and are therefore consistent across both integrated spectra and the high-resolution integral field spectroscopy data.

79 ASTRONOMY AND ASTROPHYSICS↗

Design Studies for a TPC Readout Plane Using Zigzag Patterns With Multistage GEM Detectors

Here, new design studies have been carried out for a readout plane for gas electron multiplier detectors using zigzag patterns that can significantly reduce the readout channel count while preserving excellent spatial resolution for tracking detectors. While zigzag patterns have been used in a number of applications, these studies were designed to investigate the fundamental limits of charge sharing between the electrodes to optimize the spatial resolution and minimize the nonuniformities across the readout plane, while exploring the limits of manufacturing capabilities for producing the readout board. Simulation studies were carried out to optimize the readout electrode structure, and readout boards were produced with similar zigzag designs that were tested in the laboratory using a scanning X-ray source. These studies were aimed at developing a readout board for the new time projection chamber for the sPHENIX experiment at relativistic heavy ion collider, but can readily be used in other applications, including various micropattern gas detectors, such as Micromegas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology for Clustering High-Resolution Spatiotemporal Solar Resource Data

In this report, we introduce a methodology to achieve multiple levels of spatial resolution reduction of solar resource data, with minimal impact on data variability, for use in energy systems modeling. The selection of an appropriate clustering algorithm, parameter selection including cluster size, methods of temporal data segmentation, and methods of cluster evaluation are explored in the context of a repeatable process. In describing this process, we illustrate the steps in creating a reduced resolution, but still viable, dataset to support energy systems modeling, e.g. capacity expansion or production cost modeling. This process is demonstrated through the use of a solar resource dataset; however, the methods are applicable to other resource data represented through spatiotemporal grids, including wind data. In addition to energy modeling, the techniques demonstrated in this paper can be used in a novel top-down approach to assess renewable resources within many other contexts that leverage variability in resource data but require reduction in spatial resolution to accommodate modeling or computing constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface Variability of Short-wavelength Radiation and Temperature on Exoplanets around M Dwarfs

It is a common practice to use 3D General Circulation Models (GCM) with spatial resolution of a few hundred kilometers to simulate the climate of Earth-like exoplanets. The enhanced albedo effect of clouds is especially important for exoplanets in the habitable zones around M dwarfs that likely have fixed substellar regions and substantial cloud coverage. Here, we carry out mesoscale model simulations with 3 km spatial resolution driven by the initial and boundary conditions in a 3D GCM and find that it could significantly underestimate the spatial variability of both the incident short-wavelength radiation and the temperature at planet surface. Our findings suggest that mesoscale models with cloud-resolving capability be considered for future studies of exoplanet climate.

79 ASTRONOMY AND ASTROPHYSICS↗