Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A Newton-Raphson Method Approach to Adjusting Multi-Source Solar Simulators

NASA Glenn Research Center has been using an in house designed X25 based multi-source solar simulator since 2003. The simulator is set up for triple junction solar cells prior to measurements b y adjusting the three sources to produce the correct short circuit current, lsc, in each of three AM0 calibrated sub-cells. The past practice has been to adjust one source on one sub-cell at a time, iterating until all the sub-cells have the calibrated Isc. The new approach is to create a matrix of measured lsc for small source changes on each sub-cell. A matrix, A, is produced. This is normalized to unit changes in the sources so that Ax(delta)s = (delta)isc. This matrix can now be inverted and used with the known Isc differences from the AM0 calibrated values to indicate changes in the source settings, (delta)s = A ·'x.(delta)isc This approach is still an iterative one, but all sources are changed during each iteration step. It typically takes four to six steps to converge on the calibrated lsc values. Even though the source lamps may degrade over time, the initial matrix evaluation i s not performed each time, since measurement matrix needs to be only approximate. Because an iterative approach is used the method will still continue to be valid. This method may become more important as state-of-the-art solar cell junction responses overlap the sources of the simulator. Also, as the number of cell junctions and sources increase, this method should remain applicable.

Snyder, David B.↗

Metabolic rate control during extravehicular activity simulations and measurement techniques during actual EVAS

A description of the methods used to control and measure metabolic rate during ground simulations is given. Work levels attained at the Space Environment Simulation Laboratory are presented. The techniques and data acquired during ground simulations are described and compared with inflight procedures. Data from both the Skylab and Apollo Program were utilized and emphasis is given to the methodology, both in simulation and during flight. The basic techniques of work rate assessment are described. They include oxygen consumption, which was useful for averages over long time periods, heart rate correlations based on laboratory calibrations, and liquid cooling garment temperature changes. The relative accuracy of these methods as well as the methods of real-time monitoring at the Mission Control Center are discussed. The advantages and disadvantages of each of the metabolic measurement techniques are discussed. Particular emphasis is given to the problem of utilizing oxygen decrement for short time periods and heart rate at low work levels. A summary is given of the effectiveness of work rate control and measurements; and current plans for future EVA monitoring are discussed.

David J. Horrigan↗

The tropospheric calibration model for Mariner Mars 1971

The effects of the troposphere on arrival time, range, and range rate measurement of radio signals propagating from spacecraft are examined. A tropospheric calibration model which takes into account seasonal variations, various elevations, and apparent location changes was developed. A comparison was made of the effects before and after calibration. Without calibration, a 16-m change in the distance off the spin axis, is induced for a 10-deg minimum elevation symmetrical pass. Even after calibration with the old model, the error in spin axis is still greater than 1 m. Calibration results and estimated uncertainties of the model are given in tabular form. Test results also show that the model met the required accuracy for the Mariner Mars 1971 mission.

C. C. Chao↗

Second gadolinium loading to Super-Kamiokande

The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50%. To further increase the Gd neutron capture efficiency to 75%, 26.1 tons of Gd 2 (SO 4 ) 3 ∙ 8H 2 O was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded Gd 2 (SO 4 ) 3 ∙ 8H 2 O was doubled compared to the first loading, the capacity of the powder dissolving system was doubled. We also developed new batches of gadolinium sulfate with even further reduced radioactive impurities. In addition, a more efficient screening method was devised and implemented to evaluate these new batches of Gd 2 (SO 4 ) 3 ∙ 8H 2 O. Following the second loading, the Gd concentration in SK was measured to be 333.5 ± 2.5 ppm via an Atomic Absorption Spectrometer (AAS). From the mean neutron capture time constant of neutrons from an Am/Be calibration source, the Gd concentration was independently measured to be 332.7 ± 6.8(sys.) ± 1.1(stat.) ppm, consistent with the AAS result. Furthermore, during the loading the Gd concentration was monitored continually using the capture time constant of each spallation neutron produced by cosmic-ray muons, and the final neutron capture efficiency was shown to become 1.5 times higher than that of the first loaded phase, as expected.

Gadolinium↗

Temperature-dependent mechanical properties and crystal plasticity parameters for additively manufactured Haynes-214 alloy: Experiments and numerical modeling

Our experimental mechanical testing data demonstrated that the additively manufactured (AM) laser powder bed fusion (L-PBF) Haynes-214 alloy exhibits non-linear mechanical properties as the temperature rises from ambient to 870 °C. Crystal plasticity (CP) simulations provide an effective approach to gaining deeper insights into microstructure-property linkages under thermomechanical loading. This method can reduce the need for costly high-temperature mechanical testing while accounting for the effects of crystallographic texture and grain morphology on the mechanical behavior of AM materials. However, calibrating a CP model is time-consuming because individual simulations are computationally expensive and hundreds (or more) of iterations over parameter sets may be required. To address this issue, we have designed a machine learning-differential evolution (ML-DE) CP framework that can accurately interpolate the tensile properties of AM L-PBF Haynes-214 alloy across a wide temperature range from ambient to 870 °C, with minimal reliance on experimental data. The framework uses electron backscatter diffraction (EBSD) measurements to generate statistically equivalent microstructural volume elements to serve as inputs to the CP modeling framework. Stress–strain curves were generated from 1000 CP simulations, which serve as the training data set for the three ML regression algorithms explored: linear, extra-trees, and multi-layer perceptron. These three regression models were independently evaluated to compare their efficiency and identify the most suitable algorithm for the given problem. Results revealed that the extra-trees ML regressor outperforms the other models in both qualitative and quantitative aspects with an R 2 of 0.98. Subsequently, the differential evolution optimization approach is employed to calibrate the ML-based CP material parameters with experimental results obtained at various temperatures. Finally, temperature-dependent CP material parameters are formulated. The effectiveness and efficiency of the designed framework are validated through comparison with experimental results, demonstrating a high degree of agreement. These calibrated parametric constitutive equations enable further use of the CP model to study the deformation behavior of this alloy under a wide range of thermo-mechanical loading conditions.

36 MATERIALS SCIENCE↗

Decoding Golden Eagle Movement Behavior from High-Resolution, Variable-Rate Telemetry Data Through Bayesian Filtering

The recent advances in animal tracking technology have enabled the collection of a vast amount of in situ data regarding the movement of wildlife at high spatiotemporal resolution. These data are usually available at variable time resolutions and contains noise (error) originating from GPS fixes. Decoding movement characteristics, particularly of flying animals, from telemetry data while handling these factors is a challenging yet important task for conservation purposes. Typically, this task is broken into two subtasks: resampling, and model calibration. The resampling subtask converts the variable rate positional data into a constant time interval data, while the model calibration subtask uses the resampled data to tune time-invariant parameters of the proposed models. For telemetry data at high temporal resolutions (order of 1 second), it is very challenging to decouple noise from actual movements using interpolation-based resampling techniques. Any errors introduced during resampling can significantly alter the the calibration and prediction attributes of the movement model. We address this problem through a unified Bayesian state-space framework that can handle both the resampling and calibration tasks in a single step. In addition, we use the speed and heading of the bird from telemetry data to regularize the position information of the bird. We use a Kalman filtering approach to include these nonlinearly related motion parameters within the state space framework. We cross-validated to quantify how this inclusion affects the model performance in estimating true bird movements. The relationship between the true state of the bird and environmental and topographical covariates is then represented parametrically. These parameters are then tuned using stochastic sampling strategies like Markov Chain Monte Carlo (MCMC). We use the telemetry data collected from golden eagles in the western USA to demonstrate the applicability of this approach to build a predictive, probabilistic movement model. Our preliminary results show that this approach provides improved predictive performance in terms of capturing higher-order motion parameters such as angular and horizontal accelerations, which may have simpler and more direct relationships with environmental covariates than corresponding speeds. In this talk, we will demonstrate how this state-space approach benefits the prediction capabilities of a movement model in simulating golden eagle paths through a wind power plant in Wyoming given certain atmospheric conditions. The model outcomes are aimed at informing mitigation strategies that can minimize the potential for collisions of golden eagles with wind turbines.

Bayesian methods↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid Bismuth Propellant Flow Sensor

Quantifying the propellant mass flow rate in liquid bismuth-fed electric propulsion systems has two challenging facets. First, the flow sensors must be capable of providing a resolvable measurement at propellant mass flow rates on the order of 10 mg/see with and uncertainty of less that 5%. The second challenge has to do with the fact that the materials from which the flow sensors are fabricated must be capable of resisting any of the corrosive effects associated with the high-temperature propellant. The measurement itself is necessary in order to properly assess the performance (thrust efficiency, Isp) of thruster systems in the laboratory environment. The hotspot sensor[I] has been designed to provide the bismuth propellant mass flow rate measurement. In the hotspot sensor, a pulse of thermal energy (derived from a current pulse and associated joule heating) is applied near the inlet of the sensor. The flow is "tagged" with a thermal feature that is convected downstream by the flowing liquid metal. Downstream, a temperature measurement is performed to detect a "ripple" in the local temperature associated with the passing "hotspot" in the propellant. By measuring the time between the upstream generation and downstream detection of the thermal feature, the flow speed can be calculated using a "time of flight" analysis. In addition, the system can be calibrated by measuring the accumulated mass exiting the system as a-function of time and correlating this with the time it takes the hotspot to convect through the sensor. The primary advantage of this technique is that it doesn't depend on an absolute measurement of temperature but, instead, relies on the observation of thermal features. This makes the technique insensitive to other externally generated thermal fluctuations. In this paper, we describe experiments performed using the hotspot flow sensor aimed at quantifying the resolution of the sensor technology. Propellant is expelled onto an electronic scale to provide an independent measure of the propellant mass flow rate as a function of time. In addition, two separate detection schemes are employed. The first uses a thermocouple to directly measure temperature in the fluid. The second involves the ,use of a fiber optic coupled to a photodiode allowing for detection of an increase in light emission from the fluid as the hotspot passes. the detection location.

Polzin, Kurt A.↗

New calibration techniques for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Recent laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) include new methods for the characterization of the geometric, spectral, temporal and radiometric properties of the sensor. New techniques are desired in order to: (1) increase measurement accuracy and precision, (2) minimize measurement time and expense, (3) prototype new field and inflight calibration systems, (4) resolve measurement ambiguities, and (5) add new measurement dimensions. One of the common features of these new methods is the use of the full data collection and processing power of the AVIRIS instrument and data facility. This allows the collection of large amounts of calibration data in a short period of time and is well suited to modular data analysis routines.

Chrien, Thomas G.↗

Real-Time Wireless Data Acquisition System

Current and future aerospace requirements demand the creation of a new breed of sensing devices, with emphasis on reduced weight, power consumption, and physical size. This new generation of sensors must possess a high degree of intelligence to provide critical data efficiently and in real-time. Intelligence will include self-calibration, self-health assessment, and pre-processing of raw data at the sensor level. Most of these features are already incorporated in the Wireless Sensors Network (SensorNet(TradeMark)), developed by the Instrumentation Group at Kennedy Space Center (KSC). A system based on the SensorNet(TradeMark) architecture consists of data collection point(s) called Central Stations (CS) and intelligent sensors called Remote Stations (RS) where one or more CSs can be accommodated depending on the specific application. The CS's major function is to establish communications with the Remote Stations and to poll each RS for data and health information. The CS also collects, stores and distributes these data to the appropriate systems requiring the information. The system has the ability to perform point-to-point, multi-point and relay mode communications with an autonomous self-diagnosis of each communications link. Upon detection of a communication failure, the system automatically reconfigures to establish new communication paths. These communication paths are automatically and autonomously selected as the best paths by the system based on the existing operating environment. The data acquisition system currently under development at KSC consists of the SensorNet(TradeMark) wireless sensors as the remote stations and the central station called the Radio Frequency Health Node (RFHN). The RFF1N is the central station which remotely communicates with the SensorNet(TradeMark) sensors to control them and to receive data. The system's salient feature is the ability to provide deterministic sensor data with accurate time stamps for both time critical and non-time critical applications. Current wireless standards such as Zigbee(TradeMark) and Bluetooth(Registered TradeMark) do not have these capabilities and can not meet the needs that are provided by the SensorNet technology. Additionally, the system has the ability to automatically reconfigure the wireless communication link to a secondary frequency if interference is encountered and can autonomously search for a sensor that was perceived to be lost using the relay capabilities of the sensors and the secondary frequency. The RFHN and the SensorNet designs are based on modular architectures that allow for future increases in capability and the ability to expand or upgrade with relative ease. The RFHN and SensorNet sensors .can also perform data processing which forms a distributed processing architecture allowing the system to pass along information rather than just sending "raw data points" to the next higher level system. With a relatively small size, weight and power consumption, this system has the potential for both spacecraft and aircraft applications as well as ground applications that require time critical data.

Valencia, Emilio J.↗

Evaluation of Long-Term Calibrations of the AVHRR Visible Radiances

Two systematic calibrations have been compiled for the visible radiances measured by the series of AVHRR instruments flown on the NOAA operational polar weather satellites: one by the International Satellite Cloud Climatology Project (ISCCP), anchored on NASA ER-2 underflights in the 1980s and early 1990s and covering the period 1981-2009, and one by the PATMOS-x project, anchored on comparisons to the MODIS instruments on the Aqua and Terra satellites in the 2000s and covering the period 1979-2010 (this result also includes calibration for the near-IR channels). Both methods have had to extend their anchor calibrations over a long series of instruments using different vicarious approaches, so a comparison provides an opportunity to evaluate how well this extension works by cross-checking the results at the anchor points. The basic result of this comparison is that for the ''afternoon'' series of AVHRRs, the calibrations agree to within their mutual uncertainties. However, this retrospective evaluation also shows that the representation of the time variations can be simplified. The ISCCP procedure had much more difficulty extending the calibration to the ''morning'' series of AVHRRs with the calibrations for NOAA-15 and NOAA-17 exceeding the estimated uncertainties. Given the general agreement, a new calibration for all AVHRR visible radiances (except TIROS-N, NOAA-6, NOAA-19, and MetOp-A) is proposed that is based on the average of the best linear fits to the two time records. The estimated uncertainty of these calibrations is 63% absolute (scaled radiance units).

Advanced Very High Resolution Radiometer↗

A Fast Radio Burst Backend for the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array is a radio interferometer array consisting of 16 six-meter dish antennas. The original digital backend integration time is at the seconds level, designed for H I intensity mapping experiment. A new digital backend with millisecond response is added to enable it to search for fast radio burst during its observations. The design and calibration of this backend, and the real time search pipeline for it are described in this paper. It is capable of forming 16 digital beams for each linear polarization, covering an area of 19.6 square degrees. The search pipeline is capable of searching for, recording and classifying FRBs automatically in real time. Finally, in commissioning, we succeeded in capturing the signal pulses from the pulsars PSR B0329+54 and B2021+51.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing the mineralogy and organics within a petrographic context. Adequately examining the heterogeneous composition of a meteorite often requires the collection of large Raman images with long collection times on the time-scale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. Here we utilize a Hg-Ar calibration lamp integrated into our Raman microscope to calibrate the Raman spectra within a Raman image. We characterize this method of calibration in detail.

Ryan S. Jakubek↗

Development of a Low-Level 39Ar Calibration Standard – Analysis by Absolute Gas Counting Measurements Augmented with Simulation

This paper describes the generation of 39Ar, via reactor irritation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield calibration standards that are approximately 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory’s shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50x 39Ar in P10 standard is 3.6% (k=2).

Absolute radiation measurement↗

Method and apparatus for determining a normal combustion characteristic for an internal combustion engine from an accelerometer signal

The method comprises operating a calibration engine, and collecting combustion characteristic data and reference accelerometer signals, which are correlated with each other and stored in a calibration table. The calibration table can be used by an engine to determine a real-time normal combustion characteristic when the engine is operating by collecting a real-time accelerometer sensor signal and cross correlating with the correlated data stored in the calibration table. Accordingly, the apparatus comprises a calibration engine comprising a calibration sensor, a reference accelerometer sensor and a data storage device for storing the collected calibration data that is correlated with the collected reference accelerometer signals, and an engine equipped with an accelerometer sensor, a calibration table and an electronic engine controller programmed to receive real-time accelerometer signals and cross correlate them with reference accelerometer signals to determine a real-time normal combustion characteristic.

Huang, Jian↗

Scintillator based energetic ion loss diagnostic for the National Spherical Torus Experiment

A scintillator based energetic ion loss detector has been built and installed on the National Spherical Torus Experiment (NSTX) [Synakowski et al., Nucl. Fusion 43, 1653 (2000)] to measure the loss of neutral beam ions. The detector is able to resolve the pitch angle and gyroradius of the lost energetic ions. It has a wide acceptance range in pitch angle and energy, and is able to resolve the full, one-half, and one-third energy components of the 80 keV D neutral beams up to the maximum toroidal magnetic field of NSTX. Multiple Faraday cups have been embedded behind the scintillator to allow easy absolute calibration of the diagnostic and to measure the energetic ion loss in several ranges of pitch angle with good time resolution. Several small, vacuum compatible lamps allow simple calibration of the scintillator position within the field of view of the diagnostic's video camera.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A fast particle-based approach for calibrating a 3-D model of the Antarctic ice sheet

We consider the scientifically challenging and policy-relevant task of understanding the past and projecting the future dynamics of the Antarctic ice sheet. The Antarctic ice sheet has shown a highly nonlinear threshold response to past climate forcings. Triggering such a threshold response through anthropogenic greenhouse gas emissions would drive drastic and potentially fast sea level rise with important implications for coastal flood risks. Previous studies have combined information from ice sheet models and observations to calibrate model parameters. These studies have broken important new ground but have either adopted simple ice sheet models or have limited the number of parameters to allow for the use of more complex models. These limitations are largely due to the computational challenges posed by calibration as models become more computationally intensive or when the number of parameters increases. Here, we propose a method to alleviate this problem: a fast sequential Monte Carlo method that takes advantage of the massive parallelization afforded by modern high-performance computing systems. We use simulated examples to demonstrate how our sample-based approach provides accurate approximations to the posterior distributions of the calibrated parameters. The drastic reduction in computational times enables us to provide new insights into important scientific questions, for example, the impact of Pliocene era data and prior parameter information on sea level projections. These studies would be computationally prohibitive with other computational approaches for calibration such as Markov chain Monte Carlo or emulation-based methods. We also find considerable differences in the distributions of sea level projections when we account for a larger number of uncertain parameters. For example, based on the same ice sheet model and data set, the 99th percentile of the Antarctic ice sheet contribution to sea level rise in 2300 increases from 6.5 m to 13.1 m when we increase the number of calibrated parameters from three to 11. With previous calibration methods, it would be challenging to go beyond five parameters. Here, this work provides an important next step toward improving the uncertainty quantification of complex, computationally intensive and decision-relevant models.

54 ENVIRONMENTAL SCIENCES↗