Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Histopathologic Consideration of Fiducial Gold Markers Inserted for Real-Time Tumor-Tracking Radiotherapy Against Lung Cancer

Purpose: Internal fiducial gold markers, safely inserted with bronchoscopy, have been used in real-time tumor-tracking radiotherapy for lung cancer. We investigated the histopathologic findings at several points after the insertion of the gold markers. Methods and Materials: Sixteen gold markers were inserted for preoperative marking in 7 patients who subsequently underwent partial resection of tumors by video-assisted thoracoscopic surgery within 7 days. Results: Fibrotic changes and hyperplasia of type 2 pneumocytes around the markers were seen 5 or 7 days after insertion, and fibrin exudation without fibrosis was detected 1 or 2 days after insertion. Conclusions: Because fibroblastic changes start approximately 5 days after gold marker insertion, real-time tumor-tracking radiotherapy should be started >5 days after gold marker insertion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Intrafractional Motion of Breast During Tangential Breast Irradiation Monitored With High-Sampling Frequency Using a Real-Time Tumor-Tracking Radiotherapy System

Purpose: To evaluate the three-dimensional intrafraction motion of the breast during tangential breast irradiation using a real-time tracking radiotherapy (RT) system with a high-sampling frequency. Methods and Materials: A total of 17 patients with breast cancer who had received breast conservation RT were included in this study. A 2.0-mm gold marker was placed on the skin near the nipple of the breast for RT. A fluoroscopic real-time tumor-tracking RT system was used to monitor the marker. The range of motion of each patient was calculated in three directions. Results: The mean {+-} standard deviation of the range of respiratory motion was 1.0 {+-} 0.6 mm (median, 0.9; 95% confidence interval [CI] of the marker position, 0.4-2.6), 1.3 {+-} 0.5 mm (median, 1.1; 95% CI, 0.5-2.5), and 2.6 {+-} 1.4 (median, 2.3; 95% CI, 1.0-6.9) for the right-left, craniocaudal, and anteroposterior direction, respectively. No correlation was found between the range of motion and the body mass index or respiratory function. The mean {+-} standard deviation of the absolute value of the baseline shift in the right-left, craniocaudal, and anteroposterior direction was 0.2 {+-} 0.2 mm (range, 0.0-0.8 mm), 0.3 {+-} 0.2 mm (range, 0.0-0.7 mm), and 0.8 {+-} 0.7 mm (range, 0.1-1.8 mm), respectively. Conclusion: Both the range of motion and the baseline shift were within a few millimeters in each direction. As long as the conventional wedge-pair technique and the proper immobilization are used, the intrafraction three-dimensional change in the breast surface did not much influence the dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Study Comparison of Real-Time Target Tracking and Four-Dimensional Inverse Planning for Managing Patient Respiratory Motion

Purpose: Real-time target tracking (RT-TT) and four-dimensional inverse planning (4D-IP) are two potential methods to manage respiratory target motion. In this study, we evaluated each method using the cumulative dose-volume criteria in lung cancer radiotherapy. Methods and Materials: Respiration-correlated computed tomography scans were acquired for 4 patients. Deformable image registration was applied to generate a displacement mapping for each phase image of the respiration-correlated computed tomography images. First, the dose distribution for the organs of interest obtained from an idealized RT-TT technique was evaluated, assuming perfect knowledge of organ motion and beam tracking. Inverse planning was performed on each phase image separately. The treatment dose to the organs of interest was then accumulated from the optimized plans. Second, 4D-IP was performed using the probability density function of respiratory motion. The beam arrangement, prescription dose, and objectives were consistent in both planning methods. The dose-volume and equivalent uniform dose in the target volume, lung, heart, and spinal cord were used for the evaluation. Results: The cumulative dose in the target was similar for both techniques. The equivalent uniform dose of the lung, heart, and spinal cord was 4.6 {+-} 2.2, 11 {+-} 4.4, and 11 {+-} 6.6 Gy for RT-TT with a 0-mm target margin, 5.2 {+-} 3.1, 12 {+-} 5.9, and 12 {+-} 7.8 Gy for RT-TT with a 2-mm target margin, and 5.3 {+-} 2.3, 11.9 {+-} 5.0, and 12 {+-} 5.6 Gy for 4D-IP, respectively. Conclusion: The results of our study have shown that 4D-IP can achieve plans similar to those achieved by RT-TT. Considering clinical implementation, 4D-IP could be a more reliable and practical method to manage patient respiration-induced motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Intensity-Modulated Radiotherapy Planning for Dynamic Multileaf Collimator Tracking Radiotherapy

Purpose: To develop a four-dimensional intensity-modulated radiotherapy (IMRT) planning method for dynamic multileaf collimator (DMLC)-based tumor tracking that takes respiratory motion into consideration. Methods and Materials: Using the concept of optimal deformation, a series of apertures are placed at different phases in the same segment to ensure maximally similar dose contributions at various anatomic points. We used a direct aperture optimization method to find a set of segments that achieved an optimal dose distribution for aperture shapes at the reference phase and achieved corresponding optimal deformations at other phases that took respiratory motion into consideration. In our four-dimensional direct aperture optimization (4D-DAO) method, a simulated annealing algorithm and a conjugate gradients algorithm were used to optimize the shape of the segments and the monitor units, respectively. We then compared the optimization results for three-dimensional conformal radiotherapy and 4D-DAO based on a set of simulated respiration 4D computed tomography (4DCT) data and a set of real 4DCT data. Results: Dosimetric analysis indicated that, compared with the 3DCRT method, the dose distribution is significantly improved when the optimal deformation tracking technique is used, even when the maximum velocity limit of the DMLC leaves is set. Conclusions: The proposed 4D-IMRT planning method can find a set of segments and the corresponding leaf movements, which can trace the tumor motion and thus protect more normal tissue from radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Multileaf Collimator Tracking of Respiratory Target Motion Based on a Single Kilovoltage Imager During Arc Radiotherapy

Purpose: To demonstrate and characterize dynamic multileaf collimator (DMLC) tracking of respiratory moving targets that are spatially localized with a single kV X-ray imager during arc radiotherapy. Methods and Materials: During delivery of an arc field (358 deg. gantry rotation, 72-sec duration, circular field shape), the three-dimensional (3D) position of a fiducial marker in a phantom was estimated in real time from fluoroscopic kV X-ray images acquired orthogonally to the treatment beam axis. A prediction algorithm was applied to account for system latency (570 ms) before the estimated marker position was used for DMLC aperture adaptation. Experiments were performed with 12 patient-measured tumor trajectories that were selected from 160 trajectories (46 patients) and reproduced by a programmable phantom. Offline, the 3D deviation of the estimated phantom position from the actual position was quantified. The two-dimensional (2D) beam-target deviation was quantified as the positional difference between the MLC aperture center and the marker in portal images acquired continuously during experiments. Simulations of imaging and treatment delivery extended the study to all 160 tumor trajectories and to arc treatments of 3-min and 5-min duration. Results: In the experiments, the mean root-mean-square deviation was 1.8 mm for the 3D target position and 1.5 mm for the 2D aperture position. Simulations agreed with this to within 0.1 mm and resulted in mean 2D root-mean-square beam-target deviations of 1.1 mm for all 160 trajectories for all treatment durations. The deviations were mainly caused by system latency (570 ms). Conclusions: Single-imager DMLC tracking of respiratory target motion during arc radiotherapy was implemented, providing less than 2-mm geometric uncertainty for most trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the reliability of the motion model is envisaged, the developed technique does not involve the estimation and continuous update of correlation parameters, thus requiring a less intense use of invasive imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Random walk particle tracking simulations of non-Fickian transport in heterogeneous media

Derivations of continuum nonlocal models of non-Fickian (anomalous) transport require assumptions that might limit their applicability. We present a particle-based algorithm, which obviates the need for many of these assumptions by allowing stochastic processes that represent spatial and temporal random increments to be correlated in space and time, be stationary or non-stationary, and to have arbitrary distributions. The approach treats a particle trajectory as a subordinated stochastic process that is described by a set of Langevin equations, which represent a continuous time random walk (CTRW). Convolution-based particle tracking (CBPT) is used to increase the computational efficiency and accuracy of these particle-based simulations. The combined CTRW-CBPT approach enables one to convert any particle tracking legacy code into a simulator capable of handling non-Fickian transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On high-order shock-fitting and front-tracking schemes for numerical simulation of shock–disturbance interactions

High-order methods that can resolve interactions of flow-disturbances with shock waves are critical for reliable numerical simulation of shock wave and turbulence interaction. Such problems are not well understood due to the limitations of numerical methods. Most of the popular shock-capturing methods are only first-order accurate at the shock and may incur spurious numerical oscillations near the shock. Shock-fitting algorithms have been proposed as an alternative which can achieve uniform high-order accuracy and can avoid possible spurious oscillations incurred in shock-capturing methods by treating shocks as sharp interfaces. We explore two ways for shock-fitting: conventional moving grid set-up and a new fixed grid set-up with front tracking. In the conventional shock-fitting method, a moving grid is fitted to the shock whereas in the newly developed fixed grid set-up the shock front is tracked using Lagrangian points and is free to move across the underlying fixed grid.

Rawat, Pradeep Singh↗

An efficient level set method for tracking many materials

Here, we present an efficient level set method to track an arbitrary number of materials. The algorithm is optimal in the sense that it only needs to store a single unsigned distance-like function and a single integer indicator function, independent of the number of materials or distinct regions being tracked. Furthermore, for smooth velocity fields and smooth interface shape, arbitrarily high order solutions can be demonstrated. For interfaces that are or become kinked, the solution is limited to second-order convergence rates in the L 1 norm and first-order in the L ∞ norm.

97 MATHEMATICS AND COMPUTING↗

Latent space dynamics identification for interface tracking with application to shock-induced pore collapse

Capturing sharp, evolving interfaces remains a central challenge in reduced-order modeling, especially when data is limited and the system exhibits localized nonlinearities or discontinuities. Here, we propose LaSDI-IT (Latent Space Dynamics Identification for Interface Tracking), a data-driven framework that combines low-dimensional latent dynamics learning with explicit interface-aware encoding to enable accurate and efficient modeling of physical systems involving moving material boundaries. At the core of LaSDI-IT is a revised autoencoder architecture that jointly reconstructs the physical field and an indicator function representing material regions or phases, allowing the model to track complex interface evolution without requiring detailed physical models or mesh adaptation. The latent dynamics are learned through linear regression in the encoded space and generalized across parameter regimes using Gaussian process interpolation with greedy sampling. We demonstrate LaSDI-IT on the problem of shock-induced pore collapse in high explosives, a process characterized by sharp temperature gradients and dynamically deforming pore geometries. The method achieves relative prediction errors below 9% across the parameter space, accurately recovers key quantities of interest such as pore area and hot spot formation, and matches the performance of dense training with only half the data. This latent dynamics prediction was 10 6 times faster than the conventional high-fidelity simulation, proving its utility for multi-query applications. These results highlight LaSDI-IT as a general, data-efficient framework for modeling discontinuity-rich systems in computational physics, with potential applications in multiphase flows, fracture mechanics, and phase change problems.

Gaussian process↗

Multi-probe microstructure tracking during heat treatment without an in-situ setup: Case studies on martensitic steel, dual phase steel and β-Ti alloy

In-situ scanning electron microscopy observations of the microstructure evolution during heat treatments are increasingly demanded due to the growing number of alloys with complex microstructures. Post-mortem characterization of the as-processed microstructures rarely provides sufficient insight on the exact route of the microstructure formation. On the other hand, in-situ SEM approaches are often limited due to the arising challenges upon using an in-situ heating setup, e.g. in (i) employing different detectors, (ii) preventing specimen surface degradation, or (iii) controlling and measuring the temperature precisely. Here, we explore and expand the capabilities of the “mid-way” solution by step-wise microstructure tracking, ex-situ, at selected steps of heat treatment. This approach circumvents the limitations above, as it involves an atmosphere and temperature well-controlled dilatometer, and high resolution microstructure characterization (using electron channeling contrast imaging, electron backscatter diffraction, atom probe tomography, etc.). We demonstrate the capabilities of this approach by focusing on three cases: (i) nano-scale carbide precipitation during low-temperature tempering of martensitic steels, (ii) formation of transformation-induced geometrically necessary dislocations in a dual-phase steel during intercritical annealing, and (iii) the partial recrystallization of a metastable β-Ti alloy. - Highlights: • A multi-probe method to track microstructures during heat treatment is developed. • It enables the analysis of various complex phenomena, even those at atomistic scale. • It circumvents some of the free surface effects of classical in-situ experiments.

36 MATERIALS SCIENCE↗

twoaxistracking – a python package for simulating self-shading of two-axis tracking solar collectors

Self-shading in fields of two-axis tracking collectors typically ranges from 1% to 6% of the annual incident irradiation. It is thus essential to account for shading in order to obtain accurate yield estimates and financing for such solar projects. The present study presents the free and open-source Python package twoaxistracking for simulating self-shading in fields of two-axis tracking collectors. The package is freely available at: https://github.com/pvlib/twoaxistracking. The main steps of the method and mathematical formulation are described. Additionally, a demonstration of how to use the package is presented. The shading calculation method excels over previous methods found in the literature in that it can: handle arbitrary aperture geometries and distinguish between the total and active areas; account for sloped ground and collectors with different heights within the same field; reduce computation time by skipping calculations at high solar elevation angles.

14 SOLAR ENERGY↗

The Performance of the Gamma-Ray Energy Tracking In-Beam Nuclear Array GRETINA

The Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) is a new generation high-resolution -ray spectrometer consisting of electrically segmented high-purity germanium crystals. GRETINA is capable of reconstructing the energy and position of each -ray interaction point inside the crystal with high resolution. This enables -ray energy tracking which in turn provides an array with large photopeak efficiency, high resolution and good peak-to-total ratio. GRETINA is used for nuclear structure studies with demanding -ray detection requirements and it is suitable for experiments with radioactive-ion beams with high recoil velocities. The GRETINA array has a 1 solid angle coverage and constitutes the first stage towards the full 4 array GRETA. We present in this paper the main parts and the performance of the GRETINA system.

Paschalis, S.↗

RPC based tracking system at CERN GIF++ facility

With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking of Marangoni driven motion during laser powder bed fusion

Laser Powder Bed Fusion (LPBF) can be used to create Functionally Graded Materials (FGMs) by selectively distributing property augmenting particles throughout the build matrix. With this method parts can be created with nonhomogeneous properties tuned to spatially varied, pre-determined design constraints. To unlock this capability, the fluid motion that occurs in the molten liquid phase must be thoroughly understood. More importantly, the actual tracking of motion during the LPBF process is needed. Further, a numerical model of heat transfer and fluid flow in LPBF process was created. Using results from the model the motion of particles starting at many different locations was tracked. The average change in position for these particles based on starting location was calculated. The effects of non-dimensional parameters on melt pool size were examined. These results were validated experimentally and compared to what is available in the literature.

42 ENGINEERING↗

A measurement of the angular distribution of the diffuse optical transmittance of etched nuclear tracks in CR-39

This paper presents a device to measure the angular distribution of the diffuse optical transmittance produced by etched nuclear tracks in polyallyl diglycol carbonate (PADC) detector. The device makes use of a stepper motor to move an array of four photodetectors around the sample in 1.8-degree steps. The integrated transmitted light was observed to increase monotonically with the etched track density in a range from zero to 2.8 x 10^5 per cm^2, using a neutron Am Be source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗