Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Autonomous Navigation with Ground-to-Space Doppler Measurements Referenced to a Temperature-Compensated Crystal Oscillator

The National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) has spent several years developing operational Onboard Navigation Systems (ONS's) to provide real-time autonomous, high-accuracy navigation products for spacecraft using NASA's space and ground communication systems. The highly successful Tracking and Data Relay Satellite System (TDRSS) ONS (TONS) experiment on the Explorer Platform/Extreme Ultraviolet Explorer (EP/EUVE) spacecraft, launched June 7, 1992, flight-demonstrated the ONS for high-accuracy navigation using TDRSS forward- link communications services, In late 1994, the ground station ONS (GONS) experiment, using the same EP/EUVE flight hardware, flight-demonstrated the feasibility of high-accuracy autonomous navigation using ground station forward-link communication services, with an ultrastable oscillator (USO) as the frequency reference (1 part in 10(exp 10) over 24 hours). This paper provides a follow-on analysis of GONS performance to assess the navigation accuracy achievable if GONS uses the significantly less stable (5 parts in 10(exp 8) over 24 hours, compared with a specification of 1 part in 10(exp 6)) Temperature-Compensated Crystal Oscillator (TCXO), which is integral to the transponder, as a frequency reference rather than an external USO. The GONS TCXO experiment results from a 20-day period are used to project the expected performance of an operational system. The GONS processes Doppler data derived from nominally scheduled ground station forward-link communication services using a sequential estimation algorithm enhanced by a sophisticated process noise model to provide onboard orbit and frequency determination. To evaluate the navigation accuracies achievable if a TCXO were used, actual experiment data (which used the USO as the frequency reference) were corrupted with errors from real TDRSS one-way return tracking measurements taken from EP/EUVE's TCXO. Analysis of the GONS TCXO experiment performance indicates that real-time onboard position accuracies of better than 300 meters (1 sigma) are achievable with as few as two tracking contacts per day for the EP/EUVE 525-kilometer altitude, 28.5-degree inclination orbit, provided the TCXO is as stable as that in EP/EUVE's TDRSS transponder. GONS using a TCXO frequency reference provides a viable option for many upcoming spacecraft missions with moderate position accuracy requirements and an interest in reducing their operational costs with autonomous navigation.

Radomski, M. S.↗

Study to investigate and evaluate means of optimizing the Ku-band combined radar/communication functions for the space shuttle

The performance of the space shuttle orbiter's Ku-Band integrated radar and communications equipment is analyzed for the radar mode of operation. The block diagram of the rendezvous radar subsystem is described. Power budgets for passive target detection are calculated, based on the estimated values of system losses. Requirements for processing of radar signals in the search and track modes are examined. Time multiplexed, single-channel, angle tracking of passive scintillating targets is analyzed. Radar performance in the presence of main lobe ground clutter is considered and candidate techniques for clutter suppression are discussed. Principal system parameter drivers are examined for the case of stationkeeping at ranges comparable to target dimension. Candidate ranging waveforms for short range operation are analyzed and compared. The logarithmic error discriminant utilized for range, range rate and angle tracking is formulated and applied to the quantitative analysis of radar subsystem tracking loops.

Weber, C. L.↗

Spectral characteristics of time-dependent orbit errors in altimeter height measurements

A mean reference surface and time-dependent orbit errors are estimated simultaneously for each exact-repeat ground track from the first two years of Geosat sea level estimates based on the Goddard Earth model (GEM)-T2 orbits. Motivated by orbit theory and empirical analysis of Geosat data, the time-dependent orbit errors are modeled as 1 cycle per revolution (cpr) sinusoids with slowly varying amplitude and phase. The method recovers the known 'bow tie effect' introduced by the existence of force model errors within the precision orbit determination (POD) procedure used to generate the GEM-T2 orbits. The bow tie pattern of 1-cpr orbit errors is characterized by small amplitudes near the middle and larger amplitudes (up to 160 cm in the 2 yr of data considered here) near the ends of each 5- to 6-day orbit arc over which the POD force model is integrated. A detailed examination of these bow tie patterns reveals the existence of daily modulations of the amplitudes of the 1-cpr sinusoid orbit errors with typical and maximum peak-to-peak ranges of about 14 cm and 30 cm, respectively. The method also identifies a daily variation in the mean orbit error with typical and maximum peak-to-peak ranges of about 6 and 30 cm, respectively, that is unrelated to the predominant 1-cpr orbit error. Application of the simultaneous solution method to the much less accurate Geosat height estimates based on the Naval Astronautics Group orbits concludes that the accuracy of POD is not important for collinear altimetric studies of time-dependent mesoscale variability (wavelengths shorter than 1000 km), as long as the time-dependent orbit errors are dominated by 1-cpr variability and a long-arc (several orbital periods) orbit error estimation scheme such as that presented here is used.

Chelton, Dudley B.↗

Navigation Guidelines for Orbital Formation Flying Missions

Some simple guidelines based on the accuracy in determining a satellite formation's semi-major axis differences are useful in making preliminary assessments of the navigation accuracy needed to support such missions. These guidelines are valid for any elliptical orbit, regardless of eccentricity. Although maneuvers required for formation establishment, reconfiguration, and station-keeping require accurate prediction of the state estimate to the maneuver time, and hence are directly affected by errors in all the orbital elements, experience has shown that determination of orbit plane orientation and orbit shape to acceptable levels is less challenging than the determination of orbital period or semi-major axis. Furthermore, any differences among the member's semi-major axis are undesirable for a satellite formation, since it will lead to differential along-track drift due to period differences. Since inevitable navigation errors prevent these differences from ever being zero, one may use the guidelines this paper presents to determine how much drift will result from a given relative navigation accuracy, or vice versa. Since the guidelines do not account for non-two-body perturbations, they may be viewed as useful preliminary design tools, rather than as the basis for mission navigation requirements, which should be based on detailed analysis of the mission configuration, including all relevant sources of uncertainty.

Carpenter, J. Russell↗

Navigation Accuracy Guidelines for Orbital Formation Flying Missions

Some simple guidelines based on the accuracy in determining a satellite formation's semi-major axis differences are useful in making preliminary assessments of the navigation accuracy needed to support such missions. These guidelines are valid for any elliptical orbit, regardless of eccentricity. Although maneuvers required for formation establishment, reconfiguration, and station-keeping require accurate prediction of the state estimate to the maneuver we, and hence are directly affected by errors in all the orbital elements, experience has shown that determination of orbit plane orientation and orbit shape to acceptable levels is less challenging than the determination of orbital period or semi-major axis. Furthermore, any differences among the member s semi-major axes are undesirable for a satellite formation, since it will lead to differential along-track drift due to period differences. Since inevitable navigation errors prevent these differences from ever being zero, one may use the guidelines this paper presents to determine how much drift will result from a given relative navigation accuracy, or conversely what navigation accuracy is required to limit drift to a given rate. Since the guidelines do not account for non-two-body perturbations, they may be viewed as useful preliminary design tools, rather than as the basis for mission navigation requirements, which should be based on detailed analysis of the mission configuration, including all relevant sources of uncertainty.

Carpenter, J. Russell↗

Navigation Accuracy Guidelines for Orbital Formation Flying

Some simple guidelines based on the accuracy in determining a satellite formation s semi-major axis differences are useful in making preliminary assessments of the navigation accuracy needed to support such missions. These guidelines are valid for any elliptical orbit, regardless of eccentricity. Although maneuvers required for formation establishment, reconfiguration, and station-keeping require accurate prediction of the state estimate to the maneuver time, and hence are directly affected by errors in all the orbital elements, experience has shown that determination of orbit plane orientation and orbit shape to acceptable levels is less challenging than the determination of orbital period or semi-major axis. Furthermore, any differences among the member s semi-major axes are undesirable for a satellite formation, since it will lead to differential along-track drift due to period differences. Since inevitable navigation errors prevent these differences from ever being zero, one may use the guidelines this paper presents to determine how much drift will result from a given relative navigation accuracy, or conversely what navigation accuracy is required to limit drift to a given rate. Since the guidelines do not account for non-two-body perturbations, they may be viewed as useful preliminary design tools, rather than as the basis for mission navigation requirements, which should be based on detailed analysis of the mission configuration, including all relevant sources of uncertainty.

Carpenter, J. Russell↗

Untrained users derail your caboose? Learn to get on track

You've implemented Oracle, and low-and-behold, your users can't bear it. They're making costly errors, finding creative work-arounds, and being mavericks with your system, because user training wasn't on track. This paper discusses how to build a proactive, comprehensive training program to get your users back on track.

Oracle training lessons learned training lifecycle↗

Radar error statistics for the space shuttle

Radar error statistics of C-band and S-band that are recommended for use with the groundtracking programs to process space shuttle tracking data are presented. The statistics are divided into two parts: bias error statistics, using the subscript B, and high frequency error statistics, using the subscript q. Bias errors may be slowly varying to constant. High frequency random errors (noise) are rapidly varying and may or may not be correlated from sample to sample. Bias errors were mainly due to hardware defects and to errors in correction for atmospheric refraction effects. High frequency noise was mainly due to hardware and due to atmospheric scintillation. Three types of atmospheric scintillation were identified: horizontal, vertical, and line of sight. This was the first time that horizontal and line of sight scintillations were identified.

Lear, W. M.↗

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

Shuttle program: Ground tracking data program document shuttle OFT launch/landing

The equations for processing ground tracking data during a space shuttle ascent or entry, or any nonfree flight phase of a shuttle mission are given. The resulting computer program processes data from up to three stations simultaneously: C-band station number 1; C-band station number 2; and an S-band station. The C-band data consists of range, azimuth, and elevation angle measurements. The S-band data consists of range, two angles, and integrated Doppler data in the form of cycle counts. A nineteen element state vector is used in Kalman filter to process the measurements. The acceleration components of the shuttle are taken to be independent exponentially-correlated random variables. Nine elements of the state vector are the measurement bias errors associated with range and two angles for each tracking station. The biases are all modeled as exponentially-correlated random variables with a typical time constant of 108 seconds. All time constants are taken to be the same for all nine state variables. This simplifies the logic in propagating the state error covariance matrix ahead in time.

Lear, W. M.↗

Implementation of a Model Predictive Control Strategy to Regulate Temperature Inside Plug-Flow Solar Reactor With Countercurrent Flow

Abstract Solar-driven thermochemical energy storage systems are proven to be promising energy carriers (solar fuels) to utilize solar energy by using reactive solid-state pellets. However, the production of solar fuel requires a quasi-steady-state process temperature, which represents the main challenge due to the transient nature of solar power. In this work, an adaptive model predictive controller (MPC) is presented to regulate the temperature inside a tubular solar reactor to produce solid-state solar fuel for long-term thermal storage systems. The solar reactor system consists of a vertical tube heated circumferentially over a segment of its length by concentrated solar power, and the reactive pellets (MgMn2O4) are fed from the top end and flow downwards through the heated tube. A countercurrent flowing gas supplied from the lower end interacts with flowing pellets to reduce it thermochemically at a temperature range of 1000—1500 °C. A low-order physical model was developed to simulate the dynamics of the solar reactor including the reaction kinetics, and the proposed model was validated numerically by using a 7-kW electric furnace. The numerical model then was utilized to design the MPC controller, where the control system consists of an MPC code linked to an adaptive system identification code that updates system parameters online to ensure system robustness against external disturbances (sudden change in the flow inside the reactor), model mismatches, and uncertainty. The MPC controller parameters are tuned to enhance the system performance with minimum steady-state error and overshoot. The controller is tested to track different temperature ranges between 500 °C and 1400 °C with different particles/gas mass flowrates and ramping temperature profiles. Results show that the MPC controller successfully regulated the reactor temperature within ± 1 °C of its setpoint and maintained robust performance with minimum input effort when subjected to sudden changes in the amount of flowing media and the presence of chemical reaction.

Engineering↗

A Closed-Loop Proportional-Integral (PI) Control Software for Fully Mechanically Controlled Automated Electron Microscopic Tomography

A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the results to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.

Ren, Gang↗

Complex Representation of Potentials and Fields for the Nonlinear Magnetic Insert of the Integrable Optics Test Accelerator

An alternative representation for the vector potential of the nonlinear magnetic insert for the Integrable Optics Test Accelerator (IOTA), first described in Sec. V.A. of (Danilov and Nagaitsev), is determined from first principles using standard complex variable methods. In particular, it is shown that the coupled system consisting of the 2D Laplace equation and the Bertrand-Darboux equation is equivalent to a single ordinary differential equation in the complex plane, and a simple solution is constructed. The results are consistent with (Danilov and Nagaitsev), and this concise representation provides computational advantages for particle tracking through the nonlinear insert by avoiding numerical errors caused by small denominators that appear when evaluating transverse derivatives of the vector potential near the midplane. A similar representation is provided for the spatial dependence of the two invariants of motion.

43 PARTICLE ACCELERATORS↗

An Adaptive Particle Tracking Algorithm for Lagrangian-Eulerian Simulations of Dispersed Multiphase Flows

The Lagrangian-Eulerian method is broadly used for simulations of dispersed multiphase flows by solving the continuous phase in the Eulerian framework while treating the dispersed phase as point particles in a Lagrangian framework. The accuracy of the Lagrangian-Eulerian method largely depends on the number of computational particles tracked for the Lagrangian phase. In this study, an adaptive Lagrangian particle tracking algorithm is proposed to balance the statistical error and the computational cost by dividing and merging the particles according to the local particle statistics in the computational domain. The computational particles are considered as weighted sampling points of the particle probability density functions (PDF) which represents a statistical equivalence of the Lagrangian phase. The algorithm is implemented as a part of a C++ library for Lagrangian particles, Grit, with performance portability to multi-core or many-core CPUs and Graphic Processing Unit (GPU) architectures. The accuracy of the proposed algorithm with two different schemes are studied through a test problem with analytical solutions for both the particle number density and momentum source term. The results are used to evaluate the proposed algorithm as well as to validate the parallel implementation.

Ge, Wenjun↗