Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Could what that ESCO sales rep said really be true? Savings realization rates in ESPC versus bid-to-spec projects

Claims that savings realization is greater in energy savings performance contracts (ESPCs) are rampant at least among energy service company representatives and other ESPC cheerleaders. But hard supporting evidence for these claims has been virtually non-existent. The Department of Energy's Federal Energy Management Program uses its Compliance Tracking System (CTS) database to document the performance of federal buildings and projects towards meeting various federal energy-saving goals. This paper focuses on preliminary analysis from CTS to understand and compare the performance of federal ESPCs with projects that have been implemented with more conventional government appropriations funding. The authors have found preliminary evidence using CTS that shows markedly higher savings realization rates among ESPC projects than appropriations-funded ones. There are numerous caveats to the data comparison that clamor for further study, but the difference is still intriguing. If borne out, this finding will provide concrete support to the idea that ESPCs guarantees and measurement and verification, long touted by energy service companies (ESCOs) as offering savings assurance, may truly yield substantial benefits. If ESPCs actually do perform better (i.e., have higher realization rates and savings persistence) than conventional bid-to-spec projects, the perceived premium for conducting them may look like a very good deal after all.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extremely accurate sequential verification of RELAP5-3D

Large computer programs like RELAP5-3D solve complex systems of governing, closure and special process equations to model the underlying physics of nuclear power plants. Further, these programs incorporate many other features for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. For RELAP5-3D, verification and validation are restricted to nuclear power plant applications. Verification means ensuring that the program is built right by checking that it meets its design specifications, comparing coding to algorithms and equations and comparing calculations against analytical solutions and method of manufactured solutions. Sequential verification performs these comparisons initially, but thereafter only compares code calculations between consecutive code versions to demonstrate that no unintended changes have been introduced. Recently, an automated, highly accurate sequential verification method has been developed for RELAP5-3D. The method also provides to test that no unintended consequences result from code development in the following code capabilities: repeating a timestep advancement, continuing a run from a restart file, multiple cases in a single code execution, and modes of coupled/uncoupled operation. In conclusion, mathematical analyses of the adequacy of the checks used in the comparisons are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software-defined Radio Based Wireless Tomography: Experimental Demonstration and Verification

This letter presents an experimental demonstration of software-defined-radio-based wireless tomography using computer-hosted radio devices called Universal Software Radio Peripheral (USRP). This experimental brief follows our vision and previous theoretical study of wireless tomography that combines wireless communication and RF tomography to provide a novel approach to remote sensing. Automatic data acquisition is performed inside an RF anechoic chamber. Semidefinite relaxation is used for phase retrieval, and the Born iterative method is utilized for imaging the target. Experimental results are presented, validating our vision of wireless tomography.

Bonior, Jason D↗

Verification of the Serpent-Griffin Workflow using the SNAP 8 Experimental Reactor

The Systems for Nuclear Auxiliary Power (SNAP) program accumulated extensive experimental measurements over a span of 15 years. This work builds upon previous studies which validated Serpent against experimental data for various criticality configurations of the SNAP 8 Experimental Reactor (S8ER). A 2-stage sequence is applied here with Serpent used for the generation of few-group cross sections and Griffin as the transport eigenvalue solver. Sensitivity studies are performed to qualify the effect and uncertainty of various parameters, comparing against reference models for the S8ER. The results from this work will then be expanded to create a generalized methodology for the Serpent-Griffin 2-stage approach for microreactor applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AN ASTEROSEISMIC MEMBERSHIP STUDY OF THE RED GIANTS IN THREE OPEN CLUSTERS OBSERVED BY KEPLER: NGC 6791, NGC 6819, AND NGC 6811

Studying star clusters offers significant advances in stellar astrophysics due to the combined power of having many stars with essentially the same distance, age, and initial composition. This makes clusters excellent test benches for verification of stellar evolution theory. To fully exploit this potential, it is vital that the star sample is uncontaminated by stars that are not members of the cluster. Techniques for determining cluster membership therefore play a key role in the investigation of clusters. We present results on three clusters in the Kepler field of view based on a newly established technique that uses asteroseismology to identify fore- or background stars in the field, which demonstrates advantages over classical methods such as kinematic and photometry measurements. Four previously identified seismic non-members in NGC 6819 are confirmed in this study, and three additional non-members are found-two in NGC 6819 and one in NGC 6791. We further highlight which stars are, or might be, affected by blending, which needs to be taken into account when analyzing these Kepler data.

79 ASTRONOMY AND ASTROPHYSICS↗

RELAP5-3D Resolution of Known Restart/Backup Issues

The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequential verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Conceptual Design for a Desktop Application to Support Inventory Reconciliation Activities

This paper describes desktop software being developed at Oak Ridge National Laboratory (ORNL) to empower users to reconcile observations about items at nuclear facilities more accurately, reliably, and quickly. Inventory activities at nuclear facilities are often conducted using pen and paper, which can be time-consuming, tedious, and susceptible to reading or transcription errors. The proposed inventory assistant would be a replacement for the paper-based process that could be used by International Atomic Energy Agency (IAEA) inspectors, nuclear facility operators, or treaty verification monitors to conduct an inventory of nuclear and non-nuclear items in a more timely and accurate manner. Garner, McGirl, and Whitaker previously reported their work about a conceptual design for a mobile app to assist users in the field. In general, the inventory assistant would ingest an inventory list, distribute assigned items from the inventory list to one or more mobile devices, enable inventory teams to record their observations in the field, and then enable an inventory lead to integrate and reconcile the observations to produce a final report. The assistant consists of two software components - one for the inventory teams to record observations in the field (In-Field Observations App [IFOA]) and one for the inventory lead to (1) distribute the inventory list to each team, (2) integrate the observations from each team, and (3) reconcile the inventory list with observations (Distribution, Integration, and Reconciliation Application [DIRA]). This paper reviews the inventory assistant workflow and describes the DIRA user experience in more detail. As an example, the authors have chosen to follow the use case of IAEA inspectors conducting item counting and tag checking activities of UF 6 cylinders at a gas centrifuge enrichment plant with a large number of UF 6 cylinders (e.g., thousands). These activities can currently require 30 - 40 person-days of inspection to complete. The authors believe an inventory assistant could allow the IAEA to complete item counting and tag checking using the global identifier or the operator’s barcode in 8 - 10 person-days of inspection. We would expect other users (e.g., facility operators or treaty verification monitors) to also benefit from significant time savings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CTF Code Verification and Solution Verification

The CTF code is part of the suite of codes developed with DOE funding under the CASL Program to bring the benefits of high-performance computing to issues of importance to the US nuclear power industry. This document primarily focuses on code and solution verification test problems that have been developed to ensure that CTF converges to the correct answer for the intended application. Convergence behavior and numerical errors are quantified for each of the tests. The observed convergence behavior in all available tests is consistent with expectations for the numerical methods employed by CTF, providing evidence that there are no significant code bugs or algorithm deficiencies in the code. The suite of code verification and solution verification tests are mapped to core capabilities of CTF. Gaps were identified in the code verification test suite and they are being addressed. Two new code verification problems were developed to address gaps that were identified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scaling studies with the dual crystal spectrometer at the OMEGA-EP laser facility

The dual crystal spectrometer (DCS) is an approved diagnostic at the OMEGA and the OMEGA-EP laser facilities for the measurement of high energy x-rays in the 11-90 keV energy range, e.g., for verification of the x-ray spectrum of backlighter targets of point projection radiography experiments. DCS has two cylindrically bent transmission crystal channels with image plate detectors at distances behind the crystals close to the size of the respective Rowland circle diameters taking advantage of the focusing effect of the cylindrically bent geometry. DCS, with a source to crystal distance of 1.2 m, provides the required energy dispersion for simultaneous detection of x-rays in a low energy channel (11-45 keV) and a high-energy channel (19-90 keV). A scaling study is described for varied pulse length with unchanged laser conditions (energy, focusing). The study shows that the K{alpha} line intensity is not strongly dependent on the length of the laser pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-199: Predictive Models for Cone Beam CT-Based Online Verification of Pencil Beam Scanning Proton Therapy

Purpose: To utilize online CBCT scans to develop models for predicting DVH metrics in proton therapy of head and neck tumors. Methods: Nine patients with locally advanced oropharyngeal cancer were retrospectively selected in this study. Deformable image registration was applied to the simulation CT, target volumes, and organs at risk (OARs) contours onto each weekly CBCT scan. Intensity modulated proton therapy (IMPT) treatment plans were created on the simulation CT and forward calculated onto each corrected CBCT scan. Thirty six potentially predictive metrics were extracted from each corrected CBCT. These features include minimum/maximum/mean over and under-ranges at the proximal and distal surface of PTV volumes, and geometrical and water equivalent distance between PTV and each OARs. Principal component analysis (PCA) was used to reduce the dimension of the extracted features. Three principal components were found to account for over 90% of variances in those features. Datasets from eight patients were used to train a machine learning model to fit these principal components with DVH metrics (dose to 95% and 5% of PTV, mean dose or max dose to OARs) from the forward calculated dose on each corrected CBCT. The accuracy of this model was verified on the datasets from the 9th patient. Results: The predicted changes of DVH metrics from the model were in good agreement with actual values calculated on corrected CBCT images. Median differences were within 1 Gy for most DVH metrics except for larynx and constrictor mean dose. However, a large spread of the differences was observed, indicating additional training datasets and predictive features are needed to improve the model. Conclusion: Intensity corrected CBCT scans hold the potential to be used for online verification of proton therapy and prediction of delivered dose distributions.

60 APPLIED LIFE SCIENCES↗

Air Ingress Analysis: Part 1 - Theoretical Approach

Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy (DOE), is performing research and development that focuses on key phenomena important during potential scenarios that may occur in very high temperature gas-cooled reactors (VHTRs). Phenomena identification and ranking studies to date have ranked an air ingress event, following on the heels of a VHTR depressurization, as important with regard to core safety. Consequently, the development of advanced air-ingress-related models and verification and validation data are a very high priority. Following a loss of coolant and system depressurization incident, air will enter the core of the VHTR through the break, possibly causing oxidation of the graphite core and reflector graphite structure. Simple core and plant models indicate that, under certain circumstances, the oxidation may proceed at an elevated rate with additional heat generated from the oxidation reaction itself. Under postulated conditions of fluid flow and temperature, excessive degradation of lower plenum graphite caused by graphite oxidation can lead to a loss of mechanical strength. Excessive oxidation of core graphite can also lead to a release of fission products into the confinement, which could be detrimental to reactor safety. Analytical models developed in this study will improve our understanding of this phenomenon. This paper presents two sets of analytical models for the qualitative assessment of the air ingress phenomena. The results from the analytical models are compared with results of the computational fluid dynamic models (CFD) in the subsequent paper. The analytical models agree well with those CFD results.

99 GENERAL AND MISCELLANEOUS↗

Extreme Load Computational Fluid Dynamics Analysis and Verification for a Multibody Wave Energy Converter

A wave energy converter (WEC) must be designed to survive the extreme sea states that it will be subject to throughout its lifetime. Although there are many analysis methods and codes available to accomplish this, there are currently several engineering challenges to WEC survival design. Foremost, the computational design approach will typically involve a trade-off between accuracy and computational efficiency. Additionally, most computational fluid dynamics (CFD) codes are not ideally suited to modeling extreme events for WECs with multibody dynamics, power-take-off systems, and mooring systems. Finally, although WEC design standards and CFD guidelines are emerging, with the current immaturity of the WEC industry, they are not yet well established. In this study, loads on a 1:35-scale, moored, multibody WEC are evaluated with CFD. The CFD results are compared with results obtained from a computationally efficient, midfidelity model based on linearized potential flow hydrodynamics. For these model verification comparisons, both operational and survival configurations are considered. The extreme load results obtained, using both codes, indicate that the survival configuration successfully sheds loads during extreme sea states. It is also found that WEC-Sim, when appropriately applied, can provide reasonable load results, at a fraction of the computational expense of CFD. However, for the more extreme sea states, and for higher-order effects not included in the WEC-Sim model, the linear-based results have significant errors in comparison to the CFD-based results, and should be used judiciously.

16 TIDAL AND WAVE POWER↗

Validation of a deformable image registration technique for cone beam CT-based dose verification

Purpose: As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (DIR) for prostate treatments. Methods: A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformed CT. The registration quality was assessed as the ability of the DIR method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it’s suitability to be used for dose calculation. PLASTIMATCH, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. Results: The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. Conclusions: Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.

60 APPLIED LIFE SCIENCES↗

Micro-Analysis of Actinide Minerals for Nuclear Forensics and Treaty Verification

Micro-Raman spectroscopy has been demonstrated to be a viable tool for nondestructive determination of the crystal phase of relevant minerals. Collecting spectra on particles down to 5 microns in size was completed. Some minerals studied were weak scatterers and were better studied with the other techniques. A decent graphical software package should easily be able to compare collected spectra to a spectral library as well as subtract out matrix vibration peaks. Due to the success and unequivocal determination of the most common mineral false positive (zircon), it is clear that Raman has a future for complementary, rapid determination of unknown particulate samples containing actinides.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme Load Computational Fluid Dynamics Analysis and Verification for a Multibody Wave Energy Converter: Preprint

A wave energy converter (WEC) must be designed to survive the extreme sea states that it will be subject to throughout its lifetime. Although there are many analysis methods and codes available to accomplish this, there are currently several engineering challenges to WEC survival design. Foremost, the computational design approach will typically involve a trade-off between accuracy and computational efficiency. Additionally, most computational fluid dynamics (CFD) codes are not ideally suited to modeling extreme events for WECs with multibody dynamics, power-take-off systems, and mooring systems. Finally, although WEC design standards and CFD guidelines are emerging, with the current immaturity of the WEC industry, they are not yet well established. In this study, loads on a 1:35-scale, moored, multibody WEC are evaluated with CFD. The CFD results are compared with results obtained from a computationally efficient, midfidelity model based on linearized potential flow hydrodynamics. For these model verification comparisons, both operational and survival configurations are considered. The extreme load results obtained, using both codes, indicate that the survival configuration successfully sheds loads during extreme sea states. It is also found that WEC-Sim, when appropriately applied, can provide reasonable load results, at a fraction of the computational expense of CFD. However, for the more extreme sea states, and for higher-order effects not included in the WEC-Sim model, the linear-based results have significant errors in comparison to the CFD-based results, and should be used judiciously.

16 TIDAL AND WAVE POWER↗

Toxicity and Patterns of Failure of Adaptive/Ablative Proton Therapy for Early-Stage, Medically Inoperable Non-Small Cell Lung Cancer

Purpose: To analyze the toxicity and patterns of failure of proton therapy given in ablative doses for medically inoperable early-stage non-small cell lung cancer (NSCLC). Methods and Materials: Eighteen patients with medically inoperable T1N0M0 (central location) or T2-3N0M0 (any location) NSCLC were treated with proton therapy at 87.5 Gy (relative biological effectiveness) at 2.5 Gy /fraction in this Phase I/II study. All patients underwent treatment simulation with four-dimensional CT; internal gross tumor volumes were delineated on maximal intensity projection images and modified by visual verification of the target volume in 10 breathing phases. The internal gross tumor volumes with maximal intensity projection density was used to design compensators and apertures to account for tumor motion. Therapy consisted of passively scattered protons. All patients underwent repeat four-dimensional CT simulations during treatment to assess the need for adaptive replanning. Results: At a median follow-up time of 16.3 months (range, 4.8-36.3 months), no patient had experienced Grade 4 or 5 toxicity. The most common adverse effect was dermatitis (Grade 2, 67%; Grade 3, 17%), followed by Grade 2 fatigue (44%), Grade 2 pneumonitis (11%), Grade 2 esophagitis (6%), and Grade 2 chest wall pain (6%). Rates of local control were 88.9%, regional lymph node failure 11.1%, and distant metastasis 27.8%. Twelve patients (67%) were still alive at the last follow-up; five had died of metastatic disease and one of preexisting cardiac disease. Conclusions: Proton therapy to ablative doses is well tolerated and produces promising local control rates for medically inoperable early-stage NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying visual search without an eye tracker: an assessment of artificial foveation

Abstract Eye tracking is a useful tool for studying human cognition, both in the laboratory and in real-world applications. However, there are cases in which eye tracking is not possible, such as in high-security environments where recording devices cannot be introduced. After facing this challenge in our own work, we sought to test the effectiveness of using artificial foveation as an alternative to eye tracking for studying visual search performance. Two groups of participants completed the same list comparison task, which was a computer-based task designed to mimic an inventory verification process that is commonly performed by international nuclear safeguards inspectors. We manipulated the way in which the items on the inventory list were ordered and color coded. For the eye tracking group, an eye tracker was used to assess the order in which participants viewed the items and the number of fixations per trial in each list condition. For the artificial foveation group, the items were covered with a blurry mask except when participants moused over them. We tracked the order in which participants viewed the items by moving their mouse and the number of items viewed per trial in each list condition. We observed the same overall pattern of performance for the various list display conditions, regardless of the method. However, participants were much slower to complete the task when using artificial foveation and had more variability in their accuracy. Our results indicate that the artificial foveation method can reveal the same pattern of differences across conditions as eye tracking, but it can also impact participants’ task performance.

47 OTHER INSTRUMENTATION↗