Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Development of Lyocell Based Phenolic Impregnated Carbon Ablators (PICA-D) for Future NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since 1999. Due to the obsolescence of the input fiber source, new PICA materials were developed using Lyocell, a domestic rayon fiber source. Results are presented from this effort. Manufacturing included fiber conversion, fabrication of tile component and near net shaped heatshield preforms, and conversion to PICA materials. Thermal, mechanical, and representative environment arc-jet testing have been conducted. Initial testing indicates comparable performance with respect to heritage PICA material, and likely "drop-in" replacement for future NASA mission needs.

Thermal Protection↗

Response of Ablative Thermal Protection Materials to Degradation in Low Earth Orbit –Characterization of Specimens from MISSE-13

The environment of low Earth orbit presents unique material interactions due to the presence of atomic oxygen and solar spectrum UV. A variety of degradation mechanisms can occur depending, inlarge part, on the specific material system involved. This talk will review the characterization of two ablative materials, PICA-D and HEEET, as well as relevant adhesive joints and coatings. PICA-D is a variant of the phenolic impregnated carbon ablator (PICA) and is the baseline thermal protection system (TPS) on Dragonfly and the lander for Mars Sample Return (MSR). HEEET is a 3D woven system from which MSR’s Earth entry TPS is derived. The samples for these materials were flown in orbit during the Materials International Space Station Experiment-13 (MISSE-13) which launched on March 6, 2020 and returned to Earth on January 13, 2021. Changes to surface microstructure and reflectivity will be presented along with tomographic analysis. The effect of differential erosion rates on the composites and the impacts of the orbit environment on coating performances will be discussed in the context of TPS performance and mission design aspects.

MISSE↗

Response of Ablative Thermal Protection Materials to Degradation in Low Earth Orbit – Characterization of Specimens from MISSE-13

The environment of low Earth orbit presents unique material interactions due to the presence of atomic oxygen and solar spectrum UV. A variety of degradation mechanisms can occur depending, in large part, on the specific material system involved. This talk will review the characterization of two ablative materials, PICA-D and HEEET, as well as relevant adhesive joints and coatings. PICA-D is a variant of the phenolic impregnated carbon ablator (PICA) and is the baseline thermal protection system (TPS) on Dragonfly and the lander for Mars Sample Return (MSR). HEEET is a 3D woven system from which MSR’s Earth entry TPS is derived. The samples for these materials were flown in orbit during the Materials International Space Station Experiment-13 (MISSE-13) which launched on March 6, 2020 and returned to Earth on January 13, 2021. Changes to surface microstructure and reflectivity will be presented along with tomographic analysis. The effect of differential erosion rates on the composites and the impacts of the orbit environment on coating performances will be discussed in the context of TPS performance and mission design aspects.

MISSE↗

Study of Graphite Ablation at Arc-Jet Conditions using Finite-Rate and Equilibrium Chemistry Models

Moving at hypersonic speeds through the atmosphere generates immense amount of heat that triggers thermo-chemical non-equilibrium effects in the flow approaching the vehicle and leads to surface chemical reactions that cause ablation and consume the material mass. This complex behavior and interaction of the aerothermal environment with a graphite surface is com- putationally modeled in the present work using a fully-coupled simulation between flow solver CHAMPS NBS-Cart and material response solver KATS-MR. In this study, we account for the thermo-chemical non-equilibrium effects occurring in the flow and use an 11-species air-carbon re- action model to simulate the ablation of the material. The reactions at the surface such oxidation, nitridation and recombination are modeled with a newly developed air-carbon reaction model. The coupled simulation is applied to study two experimental cases performed at IHF arc-jet facility at NASA Ames research center. The obtained results are compared against the measured data of surface recession, as well as surface and in-depth temperatures. Additionally, uncoupled sim- ulations, performed with equilibrium chemistry at the wall, point out the substantial differences between the coupled and uncoupled solutions, leading to higher deviation of the predicted temper- atures. Overall, we show excellent agreement between the coupled simulation predictions and the experimental data in all measured quantities.

EDL↗

Simulations of Coupled Shoulder Ablation of A Conceptual Aeroshell

The current study explores coupled numerical simulations of flow dynamics and material response affect ablation of the shoulder region of an entry capsule used in space missions like the Mars Sample Return (MSR) project. A new computational tool named Ares, developed at NASA Ames Research Center, is applied to carry out the coupled simulations by interconnecting well-established US3D (flow solver) and Icarus (material response solver), and the material considered is three-dimensional mid-density carbon phenolic (3MDCP). Particularly, this work extends the uncoupled analysis of Shrestha et al. 2022 by incorporating the coupling mechanism across the ablating surface between fluid and the capsule geometry. For simplicity, an axisymmetric geometry of the entry system is considered. A few mission-relevant parametric studies such as angles of orientation of the material layers with respect to the streamwise direction, backshell boundary conditions, and alternation of convective heat-transfer coefficients are investigated to essentially explore Ares capability with the primary focus on shoulder location.

Coupled Ablation Modeling↗

Development of Advanced Ablative Carbon Phenolic TPS for Future NASA Missions and Commercial Space

Phenolic Impregnated Carbon Ablator (PICA) is a low-density carbon phenolic ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flagship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars lander missions such as MSL and Mars 2020. Continued development of a mass efficient, compliant version of PICA that use a carbon felt as the substrate will be presented. The felt based versions of PICA known as Conformal PICA (C-PICA) is comparable in terms of peak heat-flux capabilities compared to standard PICA. Additionally, a novel all felt PICA-Flex offers further reductions in density, with higher thermal protection efficiency resulting in additional mass savings beyond C-PICA. Furthermore, the compliant nature of these materials allows for application without Strain Isolation Pad to a wide variety of substrates, making attractive for commercial low earth orbit missions as well as NASA’s aerocapture missions to Ice Giants. NASA is currently working with several commercial partners (Varda and Inversion Space) to Technology Transfer C/S-PICA variants for commercial LEO missions. Preliminary thermal and mechanical tests have been conducted comparing the performance of Conformal and Soft-PICA and PICA-Flex materials.

Flexible Ablative TPS↗

Laser concrete ablation scaling effects.

Surface scabbling of concrete by laser processing has been demonstrated in the literature for large-area problems ({approx}50 mm wide x 10 deep) using physically large, high-power consumption, multi-kW CW laser systems. With large spot diameters ({approx}50 mm) and low power densities ({approx} 300 W/cm{sup 2}), large volume thermal stresses are induced which promote concrete cracking. This process is highly power-density and heat-input (J/m) dependent. Too high power densities cause melting and generate potentially toxic fumes by vaporizing the cement matrix material. New applications require concrete removal with more portable, lower power equipment, and low particulate and fume generation. Recent results investigating the process for small-area ({approx} 2 x 2 mm) removal are examined and discussed. Tests performed were limited to < 700W output power. Ablation via thermal cracking was observed at larger spot sizes but as the spot size approached 10 mm (with constant power density) ablation ceased and melting predominated. Scaling effects involving temperature gradients through the ITZ (Interfacial Transition Zone), the probability of including an ITZ in the beam path at decreasing spot sizes, and the gradient effects on bulk properties between rock and sand zones will be presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Modelling and Experimental Validation of Improved Performance of Lithium-Ion Batteries Having Thick Electrodes with Laser-Ablated Micro-Structures

For widespread adoption of electric vehicles, lithium-ion batteries (LiBs) need to achieve energy densities of >275 Wh/kg, cost less than $100/Wh, and charge to more than 80% capacity within 15 minutes. Increasing the battery electrode thicknesses is one way to increase cell energy densities while also saving on cell manufacturing cost by increasing the ratio of electrode active material to inactive material within each cell. However, increased electrode loading is often accompanied by decreased Li+-ion diffusion across the full thick electrodes. This leads to significant cell polarization that prevents full capacity utilization and accelerates cell degradation, especially at fast charging/discharging rates. The introduction of secondary pore networks in thick battery electrodes alleviates some of the trade-offs between energy and power performance. These microstructures provide low tortuosity pathways for facile Li+-ion diffusion deep into the thick electrodes, diminishing detrimental concentration gradients within the cell. Ultrafast-pulsed laser ablation is a promising method to introduce micro pores or channels in thick battery electrodes as it allows for precise control of pattern geometries, results in minimal damage to the electrode and can be introduced into existing roll-to-roll electrode manufacturing lines. Herein, the limitations of thick planer electrodes and the advanced predictive models to identify optimal electrode patterns for improved cycling performance will be presented. The impact of electrode laser patterning to create secondary pore networks also will be discussed. Materials characterization techniques (SEM-EDS, XRD) were used to explore the affect ultrafast laser ablation had on the electrode materials’ morphology and structure. The improvements in the patterned electrodes’ electrochemical cycling performances and degrees of wetting will be compared to a pristine baseline case. Finally, the discrepancies between experimentally obtained data and model predictions will be explained.

DIRECT ENERGY CONVERSION,ENERGY STORAGE↗

Laser Ablation of Dental Calculus Around 400 nm Using a Ti:Sapphire Laser

A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides ≤25 mJ at 400 nm (60-ns pulse width, 10-Hz repetition rate). The laser is coupled into an optical multimode fiber coiled around a 4-in.-diam drum to generate a top-hat output intensity profile. With coaxial water cooling, this is ideal for efficient, selective calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences ≥2 J/cm^2; stalling occurs below this fluence because of photobleaching. Healthy hard tissue is not removed at fluences ≤3 J/cm^2.

calculus removal↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated laser ablation-dropletProbe-mass spectrometry for absolute drug quantitation, metabolite detection, and distribution in tissue

Rationale: Spatially resolved and accurate quantitation of drug-related compounds in tissue is a much-needed capability in drug discovery research. In this work, application of an integrated laser ablation-dropletProbe-mass spectrometry surface sampling system (LADP-MS) is reported, which achieved absolute quantitation of propranolol measured from <500 × 500 μm thin tissue samples. Methods: Mouse liver and kidney thin tissue sections were coated with parylene C and analyzed for propranolol by a laser ablation/liquid extraction workflow. Non-coated adjacent sections were microdissected for validation and processed using standard bulk tissue extraction protocols. High-performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry was applied to detect the drug and its metabolites. Results: Absolute propranolol concentration in ~500 × 500 μm tissue regions measured by the two methods agreed within ±8% and had a relative standard deviation within ±17%. Quantitation down to ~400 × 400 μm tissue regions was shown, and this resolution was also used for automated mapping of propranolol and phase II hydroxypropranolol glucuronide metabolites in kidney tissue. Conclusions: This study exemplifies the capabilities of integrated laser ablation-dropletProbe-mass spectrometry (LADP-MS) for high resolution absolute drug quantitation analysis of thin tissue sections. This capability will be valuable for applications needing to quantitatively understand the spatial distribution of small molecules in tissue.

47 OTHER INSTRUMENTATION↗

Adjunctive Thermoprotection During Percutaneous Thermal Ablation Procedures: Review of Current Techniques

Although rare, unintended thermal injury to organs surrounding the ablation zone can lead to severe complications. Over the past 15 years, different protective methods have been developed to limit risk of complications, and expand indications to include more challenging lesions in various locations including liver, kidney, lung and bone. The most frequently used techniques include hydrodissection, carbodissection, balloon interposition and probe torqueing. In most cases, tumours can be physically separated from sensitive structures, reducing risk of thermal injury. Endoluminal cooling/warming is an alternative option for complex ablations close to the ureter or major bile ducts. Different techniques may be combined to achieve successful protection in locations with complex anatomy. The purpose of this review is to provide an overview of available protective measures and discuss respective advantages/drawbacks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ablation synthesis of silver nanoparticles in water and dependence on laser nature

Silver nanoparticles have been synthesized by a one step, easy, fast and green method. The nanoparticles were prepared in de-ionized water by laser ablation method using two lasers, a continuous wave (CW) diode laser and a pulsed Nd:YAG laser. The purpose of the experiment is to compare the role of nature of the laser for production of better NPs. The prepared silver nanoparticles were characterized for their, structural, physical and optical properties. The structural properties of the synthesized nanoparticles were characterized by X-ray Diffraction and the nanoparticles were found to be crystalline. The physical properties were analyzed by Atomic Force Microscopy which confirmed spherical and nanometer sized nanoparticles. The average size was 20 nm and 9 nm for continuous and pulsed laser respectively. The optical properties were analyzed by UV–Visible spectroscopy where band gap energy was investigated and increase in band gap energy as compared to bulk was observed. The green nature of laser ablation method, surface chemistry and chemical contamination of the surface of prepared nanoparticles were analyzed by Fourier Transform Infrared Spectroscopy. The thermal conductivity of the nanoparticles colloidal solutions (nanofluids) was calculated and an enhancement of 16% and 27% was observed for CW and pulsed laser prepared nanofluids respectively as compared to base liquid (de-ionized water).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Supersonic hot jet ablative testing and analysis of boron nitride nanotube hybrid composites

Boron nitride nanotubes (BNNTs) are high-strength, high-modulus nanotubes with high thermal and oxidative stabilities. Two hybrid composites were prepared with satin weave carbon fiber (CF) and resole-type phenolic resin: one with surface layers of BNNTs and one with alternating interlayers of BNNTs. The samples were subjected to hot jet tests that simulate realistic high-pressure-temperature conditions to understand the behavior of BNNTs under high-pressure erosion. Adding BNNTs to CF/phenolic laminates enhanced the ablation resistance by reinforcing the char material and mitigated localized thermal damage. Hybrid laminates exhibited up to 14% lower weight loss, 55% increase in flexural modulus, higher thermal diffusivity, and improved char yield and microstructure compared to CF/phenolic samples. The surface layer hybrid had many surviving nanotubes reinforcing the char and crystalline oxide structures that could mitigate further oxygen diffusion. Further, various characterization methods were used to deduce possible mechanisms and their products, indicating that BNNTs could serve as growth templates for direct crystalline boron oxide formation. Overall, hybrid BNNT/CF/phenolic laminates displayed better ablation resistance and favorable microstructure evolution under high-pressure conditions.

42 ENGINEERING↗

Stereotactic Ablative Body Radiation Therapy for Octogenarians With Non-Small Cell Lung Cancer

Purpose: To retrospectively investigate treatment outcomes of stereotactic ablative body radiation therapy (SABR) for octogenarians with non-small cell lung cancer (NSCLC). Methods and Materials: Between 2005 and 2012, 109 patients aged ≥80 years with T1-2N0M0 NSCLC were treated with SABR: 47 patients had histology-unproven lung cancer; 62 patients had pathologically proven NSCLC. The prescribed doses were either 50 Gy/5 fractions for peripheral tumors or 40 Gy/5 fractions for centrally located tumors. The treatment outcomes, toxicities, and the correlating factors for overall survival (OS) were evaluated. Results: The median follow-up duration after SABR was 24.2 (range, 3.0-64.6) months. Only limited toxicities were observed, except for 1 grade 5 radiation pneumonitis. The 3-year local, regional, and distant metastasis-free survival rates were 82.3%, 90.1%, and 76.8%, respectively. The OS and lung cancer-specific survival rates were 53.7% and 70.8%, respectively. Multivariate analysis revealed that medically inoperable, low body mass index, high T stage, and high C-reactive protein were the predictors for short OS. The OS for the operable octogenarians was significantly better than that for inoperable (P<.01). Conclusions: Stereotactic ablative body radiation therapy for octogenarians was feasible, with excellent OS. Multivariate analysis revealed that operability was one of the predictors for OS. For medically operable octogenarians with early-stage NSCLC, SABR should be prospectively compared with resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across multiple clinical parameters. These data serve to inform our ongoing prospective trial of stereotactic ablative volume reduction (SAVR) for severe emphysema in poor candidates for LVRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time Tumor Oxygenation Changes After Single High-dose Radiation Therapy in Orthotopic and Subcutaneous Lung Cancer in Mice: Clinical Implication for Stereotactic Ablative Radiation Therapy Schedule Optimization

Purpose: To investigate the serial changes of tumor hypoxia in response to single high-dose irradiation by various clinical and preclinical methods to propose an optimal fractionation schedule for stereotactic ablative radiation therapy. Methods and Materials: Syngeneic Lewis lung carcinomas were grown either orthotopically or subcutaneously in C57BL/6 mice and irradiated with a single dose of 15 Gy to mimic stereotactic ablative radiation therapy used in the clinic. Serial [{sup 18}F]-misonidazole (F-MISO) positron emission tomography (PET) imaging, pimonidazole fluorescence-activated cell sorting analyses, hypoxia-responsive element-driven bioluminescence, and Hoechst 33342 perfusion were performed before irradiation (day −1), at 6 hours (day 0), and 2 (day 2) and 6 (day 6) days after irradiation for both subcutaneous and orthotopic lung tumors. For F-MISO, the tumor/brain ratio was analyzed. Results: Hypoxic signals were too low to quantitate for orthotopic tumors using F-MISO PET or hypoxia-responsive element-driven bioluminescence imaging. In subcutaneous tumors, the maximum tumor/brain ratio was 2.87 ± 0.483 at day −1, 1.67 ± 0.116 at day 0, 2.92 ± 0.334 at day 2, and 2.13 ± 0.385 at day 6, indicating that tumor hypoxia was decreased immediately after irradiation and had returned to the pretreatment levels at day 2, followed by a slight decrease by day 6 after radiation. Pimonidazole analysis also revealed similar patterns. Using Hoechst 33342 vascular perfusion dye, CD31, and cleaved caspase 3 co-immunostaining, we found a rapid and transient vascular collapse, which might have resulted in poor intratumor perfusion of F-MISO PET tracer or pimonidazole delivered at day 0, leading to decreased hypoxic signals at day 0 by PET or pimonidazole analyses. Conclusions: We found tumor hypoxia levels decreased immediately after delivery of a single dose of 15 Gy and had returned to the pretreatment levels 2 days after irradiation and had decreased slightly by day 6. Our results indicate that single high-dose irradiation can produce a rapid, but reversible, vascular collapse in tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗