Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A New Facility for Testing Superconducting Solenoid Magnets with Large Fringe Fields at Fermilab

Testing superconducting solenoid with no iron flux return can be problematic for a magnet test facility due to the large magnetic fringe fields generated. These large external fields can interfere with the operation of equipment while precautions must be taken for personnel supporting the test. The magnetic forces between the solenoid under test and the external infrastructure must also be taken under consideration. A new test facility has been designed and built at Fermilab specifically for testing superconducting magnets with large external fringe fields. This paper discusses the test stand design, capabilities, and details of the instrumentation and controls with data from the first solenoid tested in this facility: the Muon Ionization Cooling Experiment (MICE) coupling coil.

43 PARTICLE ACCELERATORS↗

RF Digitizer for EIC LLRF

With the shutdown of Relativisitc Heavy Ion Collider (RHIC) in FY26, the former RHIC facility will be upgraded to the new Electron-Ion Collider (EIC). An RF Digitizer for the EIC LLRF system has been developed and tested on a RHIC 197 MHz cavity in Q2 2026 for a baseline per formance. Firmware and software has been developed and validated during the 197 MHz cavity test. Preliminary data from the cavity test shows phase noise performance signifi cantly better than the RHIC LLRF system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Finite Element Simulations of Two Vertical Drop Tests of F-28 Fuselage Sections

In March 2017, a vertical drop test of a forward fuselage section of a Fokker F-28 MK4000 aircraft was conducted as part of a joint NASA/FAA project to investigate the performance of transport aircraft under realistic crash conditions. In June 2017, a vertical drop test was conducted of a wing-box fuselage section of the same aircraft. Both sections were configured with two rows of aircraft seats, in a triple-double configuration. A total of ten Anthropomorphic Test Devices (ATDs) were secured in seats using standard lap belt restraints. The forward fuselage section was also configured with luggage in the cargo hold. Both sections were outfitted with two hat racks, each with added ballast mass. The drop tests were performed at the Landing and Impact Research facility located at NASA Langley Research Center in Hampton, Virginia. The measured impact velocity for the forward fuselage section was 346.8-in/s onto soil. The wing-box section was dropped with a downward facing pitch angle onto a sloping soil surface in order to create an induced forward acceleration in the airframe. The vertical impact velocity of the wing-box section was 349.2-in/s. A second objective of this project was to assess the capabilities of finite element simulations to predict the test responses. Finite element models of both fuselage sections were developed for execution in LS-DYNA(Registered Trademark), a commercial explicit nonlinear transient dynamic code. The models contained accurate representations of the airframe structure, the hat racks and hat rack masses, the floor and seat tracks, the luggage in the cargo hold for the forward section, and the detailed under-floor structure in the wing-box section. Initially, concentrated masses were used to represent the inertial properties of the seats, restraints, and ATD occupants. However, later simulations were performed that included finite element representations of the seats, restraints, and ATD occupants. These models were developed to more accurately replicate the seat loading of the floor and to enable prediction of occupant impact responses. Models were executed to generate analytical predictions of airframe responses, which were compared with test data to validate the model. Comparisons of predicted and experimental structural deformation and failures were made. Finally, predicted and experimental soil deformation and crater depths were also compared for both drop test configurations.

Jackson, Karen E.↗

Effects of Background Pressure and Electrical Configuration on the Velocity Field of the HERMeS Hall Thruster

A Laser-Induced Fluorescence test was performed during risk reduction testing on the HERMeS Hall thruster. This article focuses on the portion of the test to study trends in the ion acceleration characteristics with varying anode mass flow rate, background pressure, and electrical configuration. The acceleration zone of the HERMeS Hall thruster was observed to move upstream as the anode mass flow rate decreased and upstream as the background pressure increased. Examination of the characteristics of the ions near the pole covers suggested the possibility that thruster was no longer magnetically shielded at the extreme conditions of very low anode mass flow rate and high background pressure. The acceleration zone was also observed to move slightly upstream when the thruster body was floated as opposed to cathode-tied and did not move appreciably when the thruster body was grounded to the vacuum facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations.

Electric Propulsion↗

Electromagnetic calorimeter for the Heavy Photon Search Experiment at Jefferson Lab

The Heavy Photon Search Experiment (HPS) seeks to detect a hypothesised hidden sector boson, the A', predicted to be produced in dark matter decay or annihilation. Theories suggest that the A' couples weakly to electric charge through kinetic mixing, allowing it, as a result, to decay to Standard Matter (SM) lepton pair, which may explain the electron and positron excess recently observed in cosmic rays. Measuring the lepton pair decay of the A' could lead to indirect detection of dark matter. The HPS experiment is a fixed target experiment that will utilize the electron beam produced at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The detector set-up includes a silicon vertex tracker (SVT) and an Electromagnetic Calorimeter (ECal). The ECal will provide the trigger and detect e+e- pairs and its construction and testing forms the focus of this thesis. The ECal consists of 442 PbWO 4 - tapered crystals with a length 16cm and a 1.6x1.6cm 2 cross-section, stacked into a rectangular array and are coupled to Large Area APDs and corresponding pre-amplifiers. Supplementary to the ECal is a Light Monitoring System (LMS) consisting of bi-coloured LEDs that will monitor changes in APD gain and crystal transparency due to radiation damage. Before construction of the ECal each of the components were required to be individually tested to determine a number of different characteristics. Irradiation tests were performed on PbWO 4 ECal crystals and, as a comparison, one grown by a different manufacturer to determine their radiation hardness. A technique for annealing the radiation damage by optical bleaching, which involves injecting light of various wavelengths into the crystal, was tested using the blue LED from the LMS as a potential candidate. The light yield dependence on temperature was also measured for one of the PbWO 4 crystal types. Each APD was individually tested to determine if they functioned correctly and within the requirements of the experiment, then arranged into groups of similar gain at chosen applied voltages, for connection to High Voltage (HV) supplies. Each bi-coloured LED was also tested to determine if they functioned within the specifications of the experiment; including their signal quality at high frequency and their radiation hardness. The HPS crystals were recycled from a previous Jefferson Lab detector, the Inner Calorimeter from CLAS, which needed to be dismantled and reconditioned using various removal and cleaning techniques. The HPS ECal was then constructed in a new formation using a combination of different gluing and construction techniques, and initial functionality tests were performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Selection of appropriate test method for simulating steady-state spacecraft launch loads

In ground testing prior to launch the static loads portion of the launch profile may be simulated by either applying static loads directly to the spacecraft through an appropriate loading facility or by subjecting the spacecraft to acceleration loads on a centrifuge. The factors to be considered in selecting one of the two simulation methods are discussed, giving attention to the relative advantages of the two methods in each case.

Shockey, E. F.↗

Commissioning Results of the 2nd 3.5 Cell SRF Gun for ELBE

As in 2007 the first 3.5 cell superconducting radio frequency (SRF) gun was taken into operation, it turned out that the specified performance has not been achieved. However, to demonstrate the full potential of this new type of electron source, a second and slightly modified SRF gun II was built in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). We will report on commissioning and first results of the new gun, which includes in particular the characterization of the most important RF properties as well as their comparison with previous vertical test results.

Arnold, A↗

THE CRYOPLANT FOR THE ITER NEUTRAL BEAM TEST FACILITY TO BE BUILT AT RFX IN PADOVA, ITALY

The Neutral Beam Test Facility (NBTF), planned to be constructed in Padua (Italy), will constitute the prototype of the two Neutral Beam Injectors (NBI), which will be installed in the ITER plant (Cadarache-France). The NBTF is composed of a 1 MV accelerator that can produce a 40 A deuteron pulsed neutral beam particles. The necessary vacuum needed in the accelerator is achieved by two large cryopumps, designed by FZK-Karlsruhe, with radiation shields cooled between 65 K and 90 K and with cryopanels cooled by 4 bar supercritical helium (ScHe) between 4.5 K and 6.5 K. A new cryoplant facility will be installed with two large helium refrigerators: a Shield Refrigerator (SR), whose cooling capacity is up to 30 kW between 65 K and 90 K, and a helium Main Refrigerator (MR), whose equivalent cooling capacity is up to 800 W at 4.5 K. The cooling of the cryopanels is obtained with two (ScHe) 30 g/s pumps (one redundant), working in a closed cycle around 4 bar producing a pressure head of 100 mbar. Two heat exchangers are immersed in a buffer dewar connected to the MR. The MR and SR different operation modes are described in the paper, as well as the new cryoplant installation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tested by Fire - How two recent Wildfires affected Accelerator Operations at LANL

In a little more than a decade two large wild fires threatened Los Alamos and impacted accelerator operations at LANL. In 2000 the Cerro Grande Fire destroyed hundreds of homes, as well as structures and equipment at the DARHT facility. The DARHT accelerators were safe in a fire-proof building. In 2011 the Las Conchas Fire burned about 630 square kilometers (250 square miles) and came dangerously close to Los Alamos/LANL. LANSCE accelerator operations Lessons Learned during Las Conchas fire: (1) Develop a plan to efficiently shut down the accelerator on short notice; (2) Establish clear lines of communication in emergency situations; and (3) Plan recovery and keep squirrels out.

43 PARTICLE ACCELERATORS↗

The National Carbon Capture Center at the Power Systems Development Facility

The Power Systems Development Facility (PSDF) is a state-of-the-art test center sponsored by the U.S. Department of Energy (DOE) and dedicated to the advancement of clean coal technology. In addition to the development of high efficiency coal gasification processes, the PSDF features the National Carbon Capture Center (NCCC) to promote new technologies for CO2 capture from coal-derived flue gas and syngas. The NCCC includes multiple, adaptable test skids that allow technology development of CO2 capture concepts using coal-derived flue gas and syngas in industrial settings. Because of the ability to operate under a wide range of flow rates and process conditions, research at the NCCC can effectively evaluate technologies at various levels of maturity and accelerate their development paths to commercialization. During the calendar year 2013 portion of the Budget Period Four reporting period, efforts at the NCCC focused on post-combustion CO2 capture, gasification, and pre-combustion CO2 capture technology testing. Preparations for future testing were on-going as well, and involved facility upgrades and collaboration with numerous technology developers. In the area of post-combustion, testing was conducted on an enzyme-based technology, advanced solvents from two major developers, and a gas separation membrane. During the year, the gasification process was operated for three test runs, supporting development of water-gas shift and COS hydrolysis catalysts, a mercury sorbent, and several gasification support technologies. Syngas produced during gasification operation was also used for pre-combustion capture technologies, including gas separation membranes from three different technology developers, a CO2 sorbent, and CO2 solvents.

None, None↗

Progress in the MITICA beam source design

In the framework of the development of the ITER neutral beam (NB) system, a test facility is planned to be built in Padova. A full size prototype of the ITER heating NB injector (MITICA) shall be built and tested at full beam power (17 MW) as per ITER requirements. The design of the MITICA beam source has further progressed following updated optimization and overall integration criteria. In the paper, the major design choices and revisions are presented, together with some results of numerical analyses carried out in order to assess the electrostatic and thermo-mechanical behaviour of the source.

43 PARTICLE ACCELERATORS↗

Analytic redundancy management for large flexible structures

An analytic redundancy management approach for on-line component failure detection is described and illustrated using a simulation of the NASA Langley Spacecaft Control Laboratory Experiment (SCOLE) research facility. The SCOLE experimental apparatus simulated is a functional model of the Space Shuttle with a large, flexible, offset-feed antenna cantilevered from the payload bay. This approach uses a single, active, Kalman filter selected from a bank of filters, each element of which was previously designed to accommodate a specific failure condition. The residuals of this active filter are processed through a sequential probability ratio test (SPRT) filter to identify the failure state of the system and, hence, closing the failure accommodation loop, to select the active filter. Results are presented that illustrate the ability of the system to detect and recover from failures introduced in the angular rate and linear acceleration sensors on the SCOLE facility.

Shenhar, J.↗

DEVELOPMENT OF SHORT UNDULATORS FOR ELECTRON-BEAM-RADIATION INTERACTION STUDIES

Interaction of an electron beam with external field or its own radiation has widespread applications ranging from coherent-radiation generation, phase space cooling or formation of temporally-structured beams. An efficient coupling mechanism between an electron beam and radiation field relies on the use of a magnetic undulator. In this contribution we detail our plans to build short (11-period) undulators with 7-cm period refurbishing parts of the aladdin U3 undulator [1]. Possible use of these undulators at available test facilities to support experiments relevant to cooling techniques and radiation sources are outlined.

43 PARTICLE ACCELERATORS↗

Current Performance Characteristics of NASA Langley Research Center's Cockpit Motion Base and Standardized Test Procedure for Future Performance Characterization

This report documents the updated performance characteristics of NASA Langley Research Center's (LaRC) Cockpit Motion Base (CMB) after recent revisions that were made to its inner-loop, feedback control law. The modifications to the control law will be briefly described. The performance of the Cockpit Motion Facility (CMF) will be presented. A short graphical comparison to the previous control law can be found in the appendix of this report. The revised controller will be shown to yield reduced parasitic accelerations with respect to the previous controller. Metrics based on the AGARD Advisory Report No. 144 are used to assess the overall system performance due to its recent control algorithm modification. This report also documents the standardized simulator test procedure which can be used in the future to evaluate potential updates to the control law.

Cowen, Brandon↗

Recombination of Hydrogen in the Iodine Reactors

The H-Canyon facility is currently dissolving spent nuclear fuel, including Material Test Reactor (MTR) and High Flux Isotope Reactor (HFIR) fuel. Dissolution of aluminum spent nuclear fuel produces hydrogen and other NOx gases. A theory long held by H-Canyon Engineering and Facility Technical Advisors that the silver nitrate-coated berl saddles, present in the iodine reactor, used for off-gas treatment were acting as a catalytic hydrogen recombiner was captured during an external review of the Accelerated Basin Deinventory program. Results from a separate SRNL project using a Raman Spectrometer to monitor the offgas from the dissolution process indicated a lack of the expected hydrogen in the off-gas stream. To test this hypothesis, a laboratory scale iodine reactor was assembled and filled with silver nitrate-coated berl saddles. Testing with this laboratory scale reactor confirmed the recombination of hydrogen when a simulated dissolver off-gas was passed through the reactor containing silver nitrate-coated berl saddles at 173-188 °C. Control experiments performed with uncoated berl saddles resulted in no change to the hydrogen concentration after passing through the reactor. The residence time of the gas in the reactor was varied to determine if residence time had an impact on the amount of hydrogen recombination occurring. Results from these experiments indicated that at the shortest residence times tested (~5 seconds) recombination of the hydrogen still exceeded 90%; however, the percent recombination did increase at longer residence times, reaching 97.9% or greater for residence times over 10 seconds. Finally, testing performed with a simplified off-gas composition containing only hydrogen and air gave similar results, indicating that the presence of NO and N 2 O gases in the stream do not play a role in the recombination reaction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation tolerance study on irradiated AC-coupled, poly-silicon biased, p-on-n silicon strip sensors developed in India

The silicon sensors to be deployed in the next generation high energy physics experiments for operation in high luminosity scenarios, will require a high level of radiation tolerance. AC-coupled silicon strip sensors integrated with biasing poly-silicon resistors have been fabricated in collaboration with the Bharat Electronics Limited foundry using 4 inch n-type wafers in p-on-n configuration. Several sensors were irradiated with protons at different fluences at the Karlsruhe Cyclotron facility under the Advanced European Infrastructures for Detectors at Accelerators (AIDA) program. This paper reports on these radiation hardness study performed on the AC-coupled silicon sensors fabricated in India. The characterization comprises of electrical tests, including total current, voltage and strip scans and charge collection studies.

AC-coupled↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

Crashworthy design considerations for general aviation seats

This report summarizes the experimental research conducted at the NASA Langley Research Center on general aviation seat and occupant crash response and discusses seat design considerations. Included are typical floor acceleration pulses from general aviation airplane crash tests, the performance of typical general aviation seats in a simulated crash environment, and the performance of prototype energy absorbing (EA) seat designs. Static and dynamic seat testing procedures and test facilities are discussed. Also presented are results from a series of dynamic tests of typical general aviation seats and prototype EA seats.

Alfaro-Bou, E.↗