Search NASA⌕ Search

SEARCH · Search NASA

Results for “analysis workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

El Agente: An autonomous agent for quantum chemistry

Computational chemistry tools are widely used to study the behavior of chemical phenomena. Yet, the complexity of these tools can make them inaccessible to non-specialists and challenging even for experts. In this work, we introduce El Agente Q, an LLM-based multi-agent system that dynamically generates and executes quantum chemistry workflows from natural language user prompts. The system is built on a novel cognitive architecture featuring a hierarchical memory framework that enables flexible task decomposition, adaptive tool selection, post-analysis, and autonomous file handling and submission. El Agente Q is benchmarked on six university-level course exercises and two case studies, demonstrating robust problem-solving performance (averaging >87% task success) and adaptive error handling through in situ debugging. It also supports longer-term, multi-step task execution for more complex workflows, while maintaining transparency through detailed action trace logs. Together, these capabilities lay the foundation for increasingly autonomous and accessible quantum chemistry.

agentic systems↗

Using AI to Reproduce Neutrino Cross Section Analysis - Prototyping the Neutrino Discovery Platform

The Neutrino Discovery Platform (NDP) aims to accelerate DUNE-era science by making the neutrino program's existing datasets analyzable through fast, reproducible, and auditable workflows. We report a working version of two of its layers, data curation and agentic orchestration, built and tested end to end on MINERvA open data. The guiding lesson throughout is that a cross section is a measurement, and not just a plotted shape, only if it carries a defensible systematic-uncertainty budget, a trustworthy unfolding, and a reproducible record. Using a single medium-energy playlist pair from the MINERvA open-data release (about $2.05\times10^{17}$ protons on target of data), we first reproduced the shapes of two published charged-current inclusive $\nu_\mu$ measurements through a complete extraction ladder: selection, background subtraction, D'Agostini unfolding, efficiency correction, and flux normalization. These shape-level reproductions ran and tracked the published results, but they lacked the systematic-uncertainty machinery that defines a MINERvA cross section. To supply it, we vendored and built the MINERvA Analysis Toolkit and developed a many-universe systematic-uncertainty tool that produces a portable covariance artifact, a parallel event-loop runner, and a per-run auditability harness. Validated against a published covariance release, the toolchain reproduces the released statistical, flux, and muon-energy-scale terms and shows that they account for roughly 63\% of the total variance, with the remainder unreleased. Using this same infrastructure, we then performed a measurement of our own design, the hadronic recoil-energy distribution of low-energy ($E_\nu<2.5$~GeV) charged-current inclusive events, and found data/simulation shape agreement of $\chi^2/\mathrm{ndf}=1.26$. Together these results show that the platform supports original physics and not only reproductions.

Breaux, Auto [Tulane U. (main)]↗

Decomprolute is a benchmarking platform designed for multiomics-based tumor deconvolution

Tumor deconvolution is a reliable way to disentangle the diverse cell types that comprise solid tumors. To date, however, both the algorithms developed to deconvolve tumor samples, and the gold standard datasets used to assess the algorithms are geared toward the analysis of gene expression (e.g., RNA-seq) rather than protein levels in tumor cells. While gene expression is less expensive to measure, protein levels provide a more accurate view of immune markers. To facilitate the development as well as improve the reproducibility and reusability of multi-omic deconvolution algorithms, we introduce Decomprolute, a Common Workflow Language framework that leverages containerization to compare tumor deconvolution algorithms across multiomic data sets. Decomprolute incorporates the large-scale multiomic data sets produced by the Clinical Proteomic Tumor Analysis Consortium (CPTAC), which include matched mRNA expression and proteomic data from thousands of tumors across multiple cancer types to build a fully open-source, containerized proteogenomic tumor deconvolution benchmarking platform. The platform consists of modular architecture and it comes with well-defined input and output formats at each module. As a result, it is robust and extendable easily with additional algorithms or analyses. The platform is available for access and use at http://pnnl-compbio.github.io/decomprolute.

60 APPLIED LIFE SCIENCES↗

Understanding the Computing and Analysis Needs for Resiliency of Power Systems from Severe Weather Impacts

As the frequency and intensity of severe weather has increased, its effect on the electric grid has manifested in the form of significantly more and larger outages in the United States. This has become especially true for regions that were previously isolated from weather extremes. In this paper, we analyze the weather impacts on the electric power grid across a variety of weather conditions, draw correlations, and provide practical insights into the operational state of these systems. High resolution computational modeling of specific meteorological variables, computational approaches to solving power system models under these conditions, and the types of resiliency needs are highlighted as goal-oriented computing approaches are being built to address grid resiliency needs. An example analysis correlating outages to 1km day-ahead weather from two historical winter storms, calculated on a large cluster using a combination of interpolated and extrapolated inputs from multiple instrumented sites to workflows that produce primary meteorological outputs, is shown as initial proof of concept.

analysis↗

Knowledge Annotations in Scientific Workflows: An Implementation in Kepler

Abstract. Scientic research products are the result of long-term collaborations between teams. Scientic workfows are capable of helping scientists in many ways including the collection of information as to howresearch was conducted, e.g. scientic workfow tools often collect and manage information about datasets used and data transformations. However,knowledge about why data was collected is rarely documented in scientic workflows. In this paper we describe a prototype system built to support the collection of scientic expertise that infuences scientic analysis. Through evaluating a scientic research eort underway at Pacific Northwest National Laboratory, we identied features that would most benefit PNNL scientists in documenting how and why they conduct their research making this information available to the entire team. The prototype system was built by enhancing the Kepler Scientic Work-flow System to create knowledge-annotated scientic workfows and topublish them as semantic annotations.

99 GENERAL AND MISCELLANEOUS↗

Rapid Sample Processing For LC-MS Based Quantitative Proteomics Using High Intensity Focused Ultrasounds

A new sample processing workflow that uses high intensity focused ultrasound to rapidly reduce and alkylate cysteines, digest proteins and then label peptides with 18O was developed for quantitative proteomics applications. Each step was individually refined to minimize reaction times, peptide loses and undesired by-products or modifications. By using this novel workflow, mouse plasma proteins were successfully denatured, alkylated, in-solution digested, and 18O labelled in < 10 min for subsequent analysis by liquid chromatography-electrospray ionization high resolution mass spectrometry. Performance was evaluated in terms of the number of mouse plasma peptides and proteins identified in a shotgun approach and the quantitative dynamic range. The results were compared with previously published results obtained using conventional sample preparation methods and were found to be similar. Advantages of the new method include greatly simplified and accelerated sample processing, as well as being readily amenable to automation.

Lopez-Ferrer, Daniel↗

Flexible, integrated modeling of tokamak stability, transport, equilibrium, and pedestal physics

The STEP (Stability, Transport, Equilibrium, and Pedestal) integrated-modeling tool has been developed in OMFIT to predict stable, tokamak equilibria self-consistently with core-transport and pedestal calculations. STEP couples theory-based codes to integrate a variety of physics, including magnetohydrodynamic stability, transport, equilibrium, pedestal formation, and current-drive, heating, and fueling. The input/output of each code is interfaced with a centralized ITER-Integrated Modelling & Analysis Suite data structure, allowing codes to be run in any order and enabling open-loop, feedback, and optimization workflows. This paradigm simplifies the integration of new codes, making STEP highly extensible. STEP has been verified against a published benchmark of six different integrated models. Core-pedestal calculations with STEP have been successfully validated against individual DIII-D H-mode discharges and across more than 500 discharges of the H98,y2 database, with a mean error in confinement time from experiment less than 19%. STEP has also reproduced results in less conventional DIII-D scenarios, including negative-central-shear and negative-triangularity plasmas. Predictive STEP modeling has been used to assess performance in several tokamak reactors. Simulations of a high-field, large-aspect-ratio reactor show significantly lower fusion power than predicted by a zero-dimensional study, demonstrating the limitations of scaling-law extrapolations. STEP predictions have found promising scenarios for an EXhaust and Confinement Integration Tokamak Experiment, including a high-pressure, 80%-bootstrap-fraction plasma. ITER modeling with STEP has shown that pellet fueling enhances fusion gain in both the baseline and advanced-inductive scenarios. Finally, STEP predictions for the SPARC baseline scenario are in good agreement with published results from the physics basis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduce, reuse, reinterpret: An end-to-end pipeline for recycling particle physics results

Searches for new physics at the Large Hadron Collider have constrained many models of physics beyond the Standard Model. Many searches also provide resources that allow them to be reinterpreted in the context of other models. We describe a reinterpretation pipeline that examines previously untested models of new physics using supplementary information from ATLAS Supersymmetry (SUSY) searches in a way that provides accurate constraints even for models that differ meaningfully from the benchmark models of the original analysis. The public analysis information, such as public analysis routines and serialized probability models, is combined with common event generation and simulation toolkits MADGRAPH, PYTHIA8, and DELPHES into workflows steered by TOML configuration files, and bundled into the mapyde Python package. The use of mapyde is demonstrated by constraining previously untested SUSY models with compressed sleptons and electroweakinos using ATLAS results.

Stark, Giordon↗

Codebase release 0.5 for mapyde

Searches for new physics at the Large Hadron Collider have constrained many models of physics beyond the Standard Model. Many searches also provide resources that allow them to be reinterpreted in the context of other models. We describe a reinterpretation pipeline that examines previously untested models of new physics using supplementary information from ATLAS Supersymmetry (SUSY) searches in a way that provides accurate constraints even for models that differ meaningfully from the benchmark models of the original analysis. The public analysis information, such as public analysis routines and serialized probability models, is combined with common event generation and simulation toolkits MADGRAPH, PYTHIA8, and DELPHES into workflows steered by TOML configuration files, and bundled into the mapyde Python package. The use of mapyde is demonstrated by constraining previously untested SUSY models with compressed sleptons and electroweakinos using ATLAS results.

Stark, Giordon↗

Final Technical Report for: A Unified Data-Driven Approach for Programming In Situ Analysis and Visualization

The placement and movement of data is becoming the key limiting factor on both performance and energy efficiency of high performance computations. As systems generate more data, it is becoming increasingly difficult to actually move that data elsewhere for post-processing, as the rate of improvements in supporting I/O infrastructure is not keeping pace. Together, these trends are creating a shift in how we think about exascale computations, from a viewpoint that focuses on FLOPS to one that focuses on data and data-centric operations as fundamental to the reasoning about, and optimization of, scientific workflows on extreme-scale architectures. The overarching goal of our effort was the study of a unified data-driven approach for programming applications and in situ analysis and visualization. Our work was to understand the interplay between data-centric programming model requirements at extreme-scale and the overall impact of those requirements on the design, capabilities, flexibility, and implementation details for both applications and the supporting in situ infrastructure. In this context, we made many improvements to the Legion programming system (one of the leading data-centric models today) and demonstrated in situ analyses on real application codes using these improvements.

97 MATHEMATICS AND COMPUTING↗

Solution of the C5G7 Benchmark using the MOCUM Transport Code with ANSYS Unstructured Mesh

The objective of this research is to use finite element analysis (FEA) software to perform the unstructured meshing for reactor geometries and port the mesh information to MOCUM code. This workflow takes the advantage of the mature meshing module of the mainstream FEA; reduces the development effort for nuclear codes; and increases the nuclear code accuracy by using high quality meshes. In this work, ANSYS is used to build the reactor model and perform the unstructured meshing. The mesh information is then imported to the MOCUM code, a method of characteristic (MOC) transport program supporting unstructured meshes, using a developed MATLAB script. This procedure is verified by modeling the C5G7 benchmark problem. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

S AP F LOWER : an automated tool for sap flow data preprocessing, gap-filling, and analysis using deep learning

Sap flow, a critical process in plant water use and ecosystem water cycles, is often measured using thermal dissipation probes (TDP) due to their ease of installation and continuous data collection. However, sap flow data frequently include noise, outliers, and gaps, creating challenges for analysis and requiring substantial manual processing. We developed S AP F LOWER , a tool that automates data preprocessing, model training, gap-filling, sapwood area scaling and modeling, and water use analysis. It integrates autocleaning, machine learning and deep learning models (e.g. random forest, Gaussian process regression, long short-term memory (LSTM), bidirectional LSTM (BiLSTM)), and efficient workflows to process sap flow data. S AP F LOWER can remove over 90% of noisy data while preserving legitimate variations and achieve high accuracy in gap-filling based on user-determined parameters. Random forest, LSTM, and BiLSTM models reduced root mean square error to 10% or less for long-term gaps. Model training and prediction can be performed efficiently within seconds. S AP F LOWER significantly enhances the efficiency and accessibility of TDP data analysis by automating complex tasks, enabling researchers without programming expertise to employ advanced techniques. Future improvements will focus on species-specific corrections for TDP and support for additional measurement methods. S AP F LOWER is openly available on GitHub (https://github.com/JiaxinWang123/SapFlower) and Zenodo (doi: 10.5281/zenodo.13665919).

ecosystem water balance↗

Revisiting Five Years of CASMI Contests with EPA Identification Tools

Software applications for high resolution mass spectrometry (HRMS)-based non-targeted analysis (NTA) continue to enhance chemical identification capabilities. Given the variety of available applications, determining the most fit-for-purpose tools and workflows can be difficult. The Critical Assessment of Small Molecule Identification (CASMI) contests were initiated in 2012 to provide a means to evaluate compound identification tools on a standardized set of blinded tandem mass spectrometry (MS/MS) data. Five CASMI contests have resulted in recommendations, publications, and invaluable datasets for practitioners of HRMS-based screening studies. The US Environmental Protection Agency’s (EPA) CompTox Chemicals Dashboard is now recognized as a valuable resource for compound identification in NTA studies. However, this application was too new and immature in functionality to participate in the five previous CASMI contests. In this work, we performed compound identification on all five CASMI contest datasets using Dashboard tools and data in order to critically evaluate Dashboard performance relative to that of other applications. CASMI data was accessed via the CASMI webpage and processed for use in our spectral matching and identification workflow. Relative to applications used by former contest participants, our tools, data, and workflow performed well, placing more challenge compounds in the top five of ranked candidates than did the winners of three contest years and tying in a fourth. In addition, we conducted an in-depth review of the CASMI structure sets and made these reviewed sets available via the Dashboard. Our results suggest that Dashboard data and tools would enhance chemical identification capabilities for practitioners of HRMS-based NTA.

97 MATHEMATICS AND COMPUTING↗

A Noisy 10GB Provenance Database

Provenance of scientific data is a key piece of the metadata record for the data&#x27;s ongoing discovery and reuse. Provenance collection systems capture provenance on the fly, however, the protocol between application and provenance tool may not be reliable. Consequently, the provenance record can be partial, partitioned, and simply inaccurate. We use a workflow emulator that models faults to construct a large 10GB database of provenance that we know is noisy (that is, has errors). We discuss the process of generating the provenance database, and show early results on the kinds of provenance analysis enabled by the large provenance.

97 MATHEMATICS AND COMPUTING↗

Towards standards for data exchange and integration and their impact on a public database such as CEBS (Chemical Effects in Biological Systems)

Integration, re-use and meta-analysis of high content study data, typical of DNA microarray studies, can increase its scientific utility. Access to study data and design parameters would enhance the mining of data integrated across studies. However, without standards for which data to include in exchange, and common exchange formats, publication of high content data is time-consuming and often prohibitive. The MGED Society ( (www.mged.org)) was formed in response to the widespread publication of microarray data, and the recognition of the utility of data re-use for meta-analysis. The NIEHS has developed the Chemical Effects in Biological Systems (CEBS) database, which can manage and integrate study data and design from biological and biomedical studies. As community standards are developed for study data and metadata it will become increasingly straightforward to publish high content data in CEBS, where they will be available for meta-analysis. Different exchange formats for study data are being developed: Standard for Exchange of Nonclinical Data (SEND; (www.cdisc.org)); Tox-ML ( (www.Leadscope.com)) and Simple Investigation Formatted Text (SIFT) from the NIEHS. Data integration can be done at the level of conclusions about responsive genes and phenotypes, and this workflow is supported by CEBS. CEBS also integrates raw and preprocessed data within a given platform. The utility and a method for integrating data within and across DNA microarray studies is shown in an example analysis using DrugMatrix data deposited in CEBS by Iconix Pharmaceuticals.

60 APPLIED LIFE SCIENCES↗

Data Transfer Study HPSS Archiving

The movement of the large amounts of data produced by codes run in a High Performance Computing (HPC) environment can be a bottleneck for project workflows. To balance filesystem capacity and performance requirements, HPC centers enforce data management policies to purge old files to make room for new computation and analysis results. Users at Oak Ridge Leadership Computing Facility (OLCF) and many other HPC user facilities must archive data to avoid data loss during purges, therefore the time associated with data movement for archiving is something that all users must consider. This study observed the difference in transfer speed from the originating location on the Lustre filesystem to the more permanent High Performance Storage System (HPSS). The tests were done with a number of different transfer methods for files that spanned a variety of sizes and compositions that reflect OLCF user data. This data will be used to help users of Titan and other Cray supercomputers plan their workflow and data transfers so that they are most efficient for their project. We will also discuss best practice for maintaining data at shared user facilities.

Big Data↗

TU-E-BRB-00: Deformable Image Registration: Is It Right for Your Clinic

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-01: Overview of DIR Advantages/Challenges and Workflow

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗