Circuit model for the inverse Z-pinch wire array switch.

A 0D circuit code is introduced to study the wire array switch concept introduced in. It has been implemented and researched at Imperial College. An exploding wire array, the switch, is in parallel with the load, an imploding wire array. Most of the current flows in the exploding array until it expands and becomes highly resistive. The 0D code contains simple models of Joule energy deposition and plasma expansion for W and Al wires. The purpose of the device is to produce fast Z-pinch implosion, below 100ns on MAGPIE and the Sandia Z machine. Self and mutual inductances are taken into consideration as well as the rocket model for wire ablation. The switch characteristics of the exploding array are prescribed and tuned up to agree with MAGPIE shots. The dependence of the device on the configuration of the arrays is studied and scaling to ZR conditions is explored.

33 ADVANCED PROPULSION SYSTEMS↗

Electrode array for neural stimulation

An electrode array for neural stimulation is disclosed which has particular applications for use in a retinal prosthesis. The electrode array can be formed as a hermetically-sealed two-part ceramic package which includes an electronic circuit such as a demultiplexer circuit encapsulated therein. A relatively large number (up to 1000 or more) of individually-addressable electrodes are provided on a curved surface of a ceramic base portion the electrode array, while a much smaller number of electrical connections are provided on a ceramic lid of the electrode array. The base and lid can be attached using a metal-to-metal seal formed by laser brazing. Electrical connections to the electrode array can be provided by a flexible ribbon cable which can also be used to secure the electrode array in place.

47 OTHER INSTRUMENTATION↗

Atomic Force Microscopy of Arrays of Asymmetrical DNA Motifs

DNA can easily be assembled into wide and relatively flat nanostructures that lend themselves to study via Atomic Force Microscopy (AFM). It is often important to know which side of an assembly the AFM is imaging. This is particularly crucial for characterizing nanomachines, where the movement must be measured relative to fiducial features visible to the AFM. We have developed a cheap and simple technique for building DNA arrays with distinguishable sides, a technique requiring 10 or fewer strands - dozens or hundreds of strands fewer than used for these purposes previously. Our approach involves constructing arrays out of DNA tiles that have low apparent symmetry when imaged via AFM. We have surveyed the effects of varying degrees of motif asymmetry in AFM micrographs. Even at resolutions where the individual tiles cannot be resolved (either because of sub-optimal tip quality, or very gentle tapping by the AFM tip) the larger scale features of the arrays have predictable structures that allow the determination of which side of the array is facing up. We have used this information to verify that DNA hairpins attached to either the up- or down-facing side of an array on mica can be detected in AFM height scans. We have also characterized differences in appearance between hairpins attached to different sides of the arrays.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast optical control of terahertz surface plasmons in subwavelength hole-arrays at room temperature

Extraordinary optical transmission through subwavelength metallic hole-arrays has been an active research area since its first demonstration. The frequency selective resonance properties of subwavelength metallic hole arrays, generally known as surface plasmon polaritons, have potential use in functional plasmonic devices such as filters, modulators, switches, etc. Such plasmonic devices are also very promising for future terahertz applications. Ultrafast switching or modulation of the resonant behavior of the 2-D metallic arrays in terahertz frequencies is of particular interest for high speed communication and sensing applications. In this paper, we demonstrate optical control of surface plasmon enhanced resonant terahertz transmission in two-dimensional subwavelength metallic hole arrays fabricated on gallium arsenide based substrates. Optically pumping the arrays creates a conductive layer in the substrate reducing the terahertz transmission amplitude of both the resonant mode and the direct transmission. Under low optical fluence, the terahertz transmission is more greatly affected by resonance damping than by propagation loss in the substrate. An ErAs:GaAs nanoisland superlattice substrate is shown to allow ultrafast control with a switching recovery time of {approx}10 ps. We also present resonant terahertz transmission in a hybrid plasmonic film comprised of an integrated array of subwavelength metallic islands and semiconductor holes. A large dynamic transition between a dipolar localized surface plasmon mode and a surface plasmon resonance near 0.8 THz is observed under near infrared optical excitation. The reversal in transmission amplitude from a stopband to a passband and up to {pi}/2 phase shift achieved in the hybrid plasmonic film make it promising in large dynamic phase modulation, optical changeover switching, and active terahertz plasmonics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, Construction, and Initial Test of High Spatial Resolution Thermometry Arrays for Detection of Surface Temperature Profiles on SRF Cavities in Super Fluid Helium

We designed and built two high resolution (0.6-0.55mm special resolution [1.1-1.2mm separation]) thermometry arrays prototypes out of the Allen Bradley 90-120 ohm 1/8 watt resistor to measure surface temperature profiles on SRF cavities. One array was designed to be physically flexible and conform to any location on a SRF cavity; the other was modeled after the common G-10/stycast 2850 thermometer and designed to fit on the equator of an ILC (Tesla 1.3GHz) SRF cavity. We will discuss the advantages and disadvantages of each array and their construction. In addition we will present a case study of the arrays performance on a real SRF cavity TB9NR001. TB9NR001 presented a unique opportunity to test the performance of each array as it contained a dual (4mm separation) cat eye defect which conventional methods such as OST (Oscillating Superleak second-sound Transducers) and full coverage thermometry mapping were unable to distinguish between. We will discuss the new arrays ability to distinguish between the two defects and their preheating performance.

43 PARTICLE ACCELERATORS↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Abstract— Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗

Optimally placing photovoltaic arrays to maximize value of energy production based on peak power production, local solar radiation, weather, electricity market prices and rate structures

A method, system and computer program product for optimally placing photovoltaic arrays to maximize a value of energy production. Incident solar radiation for various placements of the photovoltaic arrays accommodating different azimuths and tilts is calculated. Alternating current solar photovoltaic electricity energy and power production is then estimated from the calculated solar radiation on a plane and weather data. Furthermore, a value of solar photovoltaic electricity energy and power produced by the photovoltaic arrays for the various placements is calculating using the estimated alternating current solar photovoltaic electricity production. A placement out of the various placements for the photovoltaic arrays is then selected corresponding to a highest value of the solar photovoltaic electricity produced by the photovoltaic arrays. In this manner, the appropriate placement for the photovoltaic arrays is determined that maximizes the value of energy production (where “value” may correspond to an economic value or a non-economic value).

Webber, Michael E.↗

Synthesis of molecular imprinted polymer modified TiO{sub 2} nanotube array electrode and their photoelectrocatalytic activity

A tetracycline hydrochloride (TC) molecularly imprinted polymer (MIP) modified TiO{sub 2} nanotube array electrode was prepared via surface molecular imprinting. Its surface was structured with surface voids and the nanotubes were open at top end with an average diameter of approximately 50 nm. The MIP-modified TiO{sub 2} nanotube array with anatase phase was identified by XRD and a distinguishable red shift in the absorption spectrum was observed. The MIP-modified electrode also exhibited a high adsorption capacity for TC due to its high surface area providing imprinted sites. Photocurrent was generated on the MIP-modified photoanode using the simulated solar spectrum and increased with the increase of positive bias potential. Under simulated solar light irradiation, the MIP-modified TiO{sub 2} nanotube array electrode exhibited enhanced photoelectrocatalytic (PEC) activity with the apparent first-order rate constant being 1.2-fold of that with TiO{sub 2} nanotube array electrode. The effect of the thickness of the MIP layer on the PEC activity was also evaluated. - Graphical abstract: A tetracycline hydrochloride molecularly imprinted polymer modified TiO{sub 2} nanotube array electrode was prepared via surface molecular imprinting. It showed improved response to simulated solar light and higher adsorption capability for tetracycline hydrochloride, thereby exhibiting increased PEC activity under simulated solar light irradiation. The apparent first-order rate constant was 1.2-fold of that on TiO{sub 2} nanotube array electrode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TiO{sub 2} nanorods branched on fast-synthesized large clearance TiO{sub 2} nanotube arrays for dye-sensitized solar cells

A large clearance TiO{sub 2} nanotube arrays (LTAs) has been synthesized by a not more than 12 h anodization duration and based on this a branched TiO{sub 2} nanotube arrays (BLTs) has been achieved through TiO{sub 2} nanorods branch-like grown on the LTAs. Some key factors and probable mechanisms of the fabrication processes on two novel nanoarchitectures are discussed. Exhilaratingly, it is found that the obtained LTAs has demonstrated large pore diameter and void spaces (pore diameter {approx}350 nm; void spaces {approx}160 nm; and tube length {approx}3.5 {mu}m), and the synthesized hierarchical BLTs, compared with conventional TiO{sub 2} nanotube arrays, has shown a much stronger dye absorption performance and an approximately double of the solar cell efficiency (in our case from 1.62% to 3.18% under simulated AM 1.5 conditions). - Graphical Abstract: The schematic diagram of synthesis process for LTAs and BLTs is on the above and the corresponding FESEM images of obtained photoanodes samples are shown below. Highlights: > Large clearance TiO{sub 2} nanotube arrays (LTAs) was synthesized by a fast anodization process of 12 h. > Anodization time of 12 h is just 10% of about 120 h reported in the previous references. > Branch-like TiO{sub 2} nanotube arrays (BLTs) was achieved by growing TiO{sub 2} nanorods on the LTAs. > Obtained BLTs and LTAs show impressive morphology and noticeable improvement of surface area. > BLTs shows about more than 1 times higher solar cell efficiency than that of TiO{sub 2} nanotube arrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of pseudo-random binary gratings and arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable flair. A major difficulty in using surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. Therefore, accurate calibration of profilometers, the understanding of their MTF limitations, and cross calibration between tools represents a considerable challenge for quantitative optical metrology. In previous work the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudo-random (BPR) gratings. Here, they present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocol. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat Power Spectrum Density (PSD). Three different BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Figure 1 shows the fabrication sequence. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. Figure 2 shows representative scanning probe height data for the 400 nm BPR sample. Figure 2 shows the raw Power Spectral Density for 5 different objectives. They demonstrate that the two dimensional BPR array is a very effective calibration standard. However, departures from ideal, such as square sidewall, and uniform etch depth ultimately can limit the accuracy of the calibration. The effects of fabrication imperfections on the efficiency of calibration will be discussed.

36 MATERIALS SCIENCE↗

Using multivariate analyses to compare subsets of electrodes and potentials within an electrode array for predicting sugar concentrations in mixed solutions.

A non-selective electrode array is presented for the quantification of fructose, galactose, and glucose in mixed solutions. A unique feature of this electrode array relative to other published work is the wide diversity of electrode materials incorporated within the array, being constructed of 41 different metals and metal alloys. Cyclic voltammograms were acquired for solutions containing a single sugar at varying concentrations, and the correlation between current and sugar concentration was calculated as a function of potential and electrode array element. The correlation plots identified potential regions and electrodes that scaled most linearly with sugar concentration, and the number of electrodes used in building predictive models was reduced to 15. Partial least squares regression models relating electrochemical response to sugar concentration were constructed using data from single electrodes and multiple electrodes within the array, and the predictive abilities of these models were rigorously compared using a non-parametric Wilcoxon test. Models using single electrodes (Pt:Rh (90:10) for fructose, Au:Ni (82:18) for galactose, and Au for glucose) were judged to be statistically superior or indistinguishable from those built with multiple electrodes. Additionally, for each sugar, interval partial least squares regression successfully identified a subset of potentials within a given electrode that generated a model of statistically equivalent predictive ability relative to the full potential model. While including data from multiple electrodes offered no benefit in predicting sugar concentration, use of the array afforded the versatility and flexibility of selecting the best single electrode for each sugar.

09 BIOMASS FUELS↗

Carbon nanotube nanoelectrode arrays

The present invention relates to microelectode arrays (MEAs), and more particularly to carbon nanotube nanoelectrode arrays (CNT-NEAs) for chemical and biological sensing, and methods of use. A nanoelectrode array includes a carbon nanotube material comprising an array of substantially linear carbon nanotubes each having a proximal end and a distal end, the proximal end of the carbon nanotubes are attached to a catalyst substrate material so as to form the array with a pre-determined site density, wherein the carbon nanotubes are aligned with respect to one another within the array; an electrically insulating layer on the surface of the carbon nanotube material, whereby the distal end of the carbon nanotubes extend beyond the electrically insulating layer; a second adhesive electrically insulating layer on the surface of the electrically insulating layer, whereby the distal end of the carbon nanotubes extend beyond the second adhesive electrically insulating layer; and a metal wire attached to the catalyst substrate material.

Ren, Zhifeng↗

Space and power efficient hybrid counters array

A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

47 OTHER INSTRUMENTATION↗

Growth and Anion Exchange Conversion of CH 3 NH 3 PbX 3 Nanorod Arrays for Light-Emitting Diodes

The nanowire and nanorod morphology offers great advantages for application in a range of optoelectronic devices, but these high-quality nanorod arrays are typically based on high temperature growth techniques. Here, we demonstrate the successful room temperature growth of a hybrid perovskite (CH 3 NH 3 PbBr 3 ) nanorod array, and we also introduce a new low temperature anion exchange technique to convert the CH 3 NH 3 PbBr 3 nanorod array into a CH 3 NH 3 PbI 3 nanorod array while preserving morphology. We demonstrate the application of both these hybrid perovskite nanorod arrays for LEDs. This work highlights the potential utility of postsynthetic interconversion of hybrid perovskites for nanostructured optoelectronic devices such as LEDs, which enables new strategies for the application of hybrid perovskites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

One-Step Solution Patterning for Two-Dimensional Perovskite Nanoplate Arrays

Two-dimensional perovskite crystals have attracted significant attention for their diverse optoelectronic characteristics, owing to their superior semiconducting properties. However, the majority of studies to date have focused on single crystals, which pose challenges for integration into device arrays due to their incompatibility with selective growth or conventional lithography techniques. Here, a facile one-step solution process for synthesizing 2D perovskite crystal arrays is proposed through meniscus-guided coating on patterned substrates. Here we further utilized this method for the synthesis of lateral heterostructure nanoplate arrays. Six different 2D perovskite nanoplate arrays, including epitaxial heterostructures, are successfully realized. Optical and crystallographic characterizations show the high optical performance and crystallinity of the nanoplates. Moreover, this method is further employed to prepare high-performance 2D perovskite nanoplate photosensor arrays. This strategy can be utilized as a guideline for the fundamental investigation of optical properties and the development of high-performance optoelectronics of perovskite materials including photosensors and displays.

2D perovskite nanoplates↗

Comparisons Between Array Derived Dynamic Strain Rate (ADDS) and Fiber‐Optic Distributed Acoustic Sensing (DAS) Strain Rate

Abstract Distributed acoustic sensing (DAS) strain rate and particle velocity can be compared through approximate scaling with medium velocity. We instead performed a direct comparison between array derived dynamic strain (ADDS) rate and DAS strain rate for six frequency bands. The PoroTomo project at Brady's Hot Springs, Nevada, deployed a 240‐geophone 3C array co‐located with fiber‐optic DAS system and 8.7 km of buried cable. We selected subsets of the geophone array to create four smaller arrays and computed ADDS. The horizontal components of the ADDS were rotated into the direction of the fiber‐optic cable and then compared with the observed DAS strain rates. From three example regional earthquakes of local magnitudes 2.9, 4.1, and 4.3, the ADDS are found to be coherent with DAS for frequencies ≤1 Hz. For frequencies >1‐Hz, this correlation decays quickly. Small differences between linear and areal dynamic strains at 1‐Hz suggest poor signal‐to‐noise or localized strain that is perturbed by shallow heterogeneities compare to the average strain propagating across the geophone array. The implication is that around 1‐Hz, straight fiber DAS is measuring axial strain along the fiber and can provide good approximations to translational particle motions. However, above 1‐Hz, DAS becomes more sensitive to shallow velocity gradients that can be beneficial for geophysical imaging yet becomes a limitation for traditional seismic analysis methods depending on absolute amplitude and phase from translational particle motions.

58 GEOSCIENCES↗

Arrays of Bottles of Plutonium Nitrate Solution

In October and November of 1981 thirteen approaches-to-critical were performed on a remote split table machine (RSTM) in the Critical Mass Laboratory of Pacific Northwest Laboratory (PNL) in Richland, Washington using planar arrays of polyethylene bottles filled with plutonium (Pu) nitrate solution. Arrays of up to sixteen bottles were used to measure the critical number of bottles and critical array spacing with a tight fitting Plexiglas® reflector on all sides of the arrays except the top. Some experiments used Plexiglas shells fitted around each bottles to determine the effect of moderation on criticality. Each bottle contained approximately 2.4 L of Pu(NO 3 ) 4 solution with a Pu content of 105 g Pu/L and a free acid molarity H + of 5.1. The plutonium was of low 240 Pu (2.9 wt.%) content. These experiments were sponsored by Rockwell Hanford Operations because of the lack of experimental data on the criticality of arrays of bottles of Pu solution such as might be found in storage and handling at the Purex Facility at Hanford. The results of these experiments were used “to provide benchmark data to validate calculational codes used in criticality safety assessments of [the] plant configurations” (Ref. 1). Data for this evaluation were collected from the published report (Ref. 1), the approach to critical logbook, the experimenter’s logbook, and communication with the primary experimenter, B. Michael Durst. Of the 13 experiments preformed 10 were evaluated. One of the experiments was not evaluated because it had been thrown out by the experimenter, one was not evaluated because it was a repeat of another experiment and the third was not evaluated because it reported the critical number of bottles as being greater than 25. Seven of the thirteen evaluated experiments were determined to be acceptable benchmark experiments. A similar experiment using uranyl nitrate was benchmarked as U233-SOL-THERM-014.