Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Electronics System for the GammaTracker Handheld CdZnTe Detector

We are currently developing a handheld radioisotope identifier containing eighteen position-sensitive CdZnTe crystals. In addition to isotope identification, the device performs basic Compton imaging to determine the location of suspected sources. This paper gives an overview of the electronics system we have designed for this instrument. We use specialized application-specific integrated circuits to preprocess the outputs of each CdZnTe crystal. A low-power microprocessor running Windows CE drives the user interface and implements the isotope identification and directionality computations. Finally, we use a field-programmable gate array to perform the computationally intensive imaging tasks in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tumor Bed Delineation for Partial Breast and Breast Boost Radiotherapy Planned in the Prone Position: What Does MRI Add to X-ray CT Localization of Titanium Clips Placed in the Excision Cavity Wall?

Purpose: To compare tumor bed (TB) volumes delineated using magnetic resonance imaging plus computed tomography and clips (MRCT) with those delineated using CT and clips (CT/clips) alone in postlumpectomy breast cancer patients positioned prone and to determine the value of MRCT for planning partial breast irradiation (PBI). Methods and Materials: Thirty women with breast cancer each had 6 to 12 titanium clips secured in the excision cavity walls at lumpectomy. Patients underwent CT imaging in the prone position, followed by MRI (T{sub 1}-weighted [standard and fat-suppressed] and T{sub 2}-weighted sequences) in the prone position. TB volumes were delineated separately on CT and on fused MRCT datasets. Clinical target volumes (CTV) (where CTV = TB + 15 mm) and planning target volumes (PTV) (where PTV = CTV + 10 mm) were generated. Conformity indices between CT- and MRCT-defined target volumes were calculated (ratio of the volume of agreement to total delineated volume). Discordance was expressed as a geographical miss index (GMI) (where the GMI = the fraction of total delineated volume not defined by CT) and a normal tissue index (the fraction of total delineated volume designated as normal tissue on MRCT). PBI dose distributions were generated to cover CT-defined CTV (CTV{sub CT}) with {>=}95% of the reference dose. The percentage of MRCT-defined CTV (CTV{sub MRCT}) receiving {>=}95% of the reference dose was measured. Results: Mean conformity indices were 0.54 (TB), 0.84 (CTV), and 0.89 (PTV). For TB volumes, the GMI was 0.37, and the NTI was 0.09. Median percentage volume coverage of CTV{sub CT} was 97.1% (range, 95.3%-100.0%) and of CTV{sub MRCT} was 96.5% (range, 89.0%-100.0%). Conclusions: Addition of MR to CT/clip data generated TB volumes that were discordant with those based on CT/clips alone. However, clinically satisfactory coverage of CTV{sub MRCT} by CTV{sub CT}-based tangential PBI fields provides support for CT/clip-based TB delineation remaining the method of choice for PBI/breast boost radiotherapy planned using tangential fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron CT imaging of lattice structures with engineered defects

Understanding mechanical failure, crack propagation, and compressive behavior at the micrometer scale is essential for tailoring material properties for structural performance in cellular materials. Typically, modeling of traditional polymer foam materials is clouded by the lack of control in material morphology and its inherent stochastic structure. Additive manufacturing with sub-micrometer resolution provides a direct path for experimenters to specifically tailor structures needed by modelers to explicitly probe mechanical performance. Using laboratory-based 3D X-ray computed tomographic imaging (CT), the examination of deformation and damage provides a critical path to understand how these soft materials behave. Additionally, synchrotron CT yields realistic information at higher strain rates to directly validate the robustness of our finite element modeling. For this study, nanolithographic printing was employed to generate a series of engineered lattices with increasing levels of defects through the random removal of ligaments. These structures were mechanically tested and imaged with laboratory-based microCT. Additionally, synchrotron experiments were conducted in which the structures were imaged in 3D at 14 Hz during compression at a 0.4 s –1 strain rate. These 3D images show the changes in the structure as the ligaments bend, buckle and fracture in real time. This technique provides a robust framework for developing our methodologies and future exploration of engineered structures.

36 MATERIALS SCIENCE↗

Use of Yttrium-90 Microspheres in the Treatment of Unresectable Hepatic Metastases From Breast Cancer

Purpose: Therapy for patients with unresectable liver metastases from breast cancer that were refractory to multiple treatment regimens was performed using radioactive microspheres. High doses of radiation were delivered to tumors from these permanently implanted yttrium-90 ({sup 90}Y) microspheres, delivered through the hepatic arterial vessels. Methods and Materials: Women from three institutions were selected for treatment, after screening that demonstrated vascular access to all tumors and after imaging confirmed that microspheres would be implanted only in the liver tumors. All patients were followed with laboratory and imaging studies at regular intervals until death. Toxicities, both acute and late were recorded, and actuarial survival determined. Results: A total of 44 women were treated from April 2002 to April 2005. Median follow-up of these women was 14 months (1-42 months). No treatment-related procedure deaths or radiation related veno-occlusive liver failures were found. Computed tomographic imaging partial response was 47% and positron emission tomographic response 95%. Conclusion: In this group of heavily pretreated patients, radioactive microspheres produced an encouraging median survival, with acceptable toxicity and a significant objective response rate, suggesting that further investigation of this approach is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMAGES: An interactive image processing system

The IMAGES interactive image processing system was created specifically for undergraduate remote sensing education in geography. The system is interactive, relatively inexpensive to operate, almost hardware independent, and responsive to numerous users at one time in a time-sharing mode. Most important, it provides a medium whereby theoretical remote sensing principles discussed in lecture may be reinforced in laboratory as students perform computer-assisted image processing. In addition to its use in academic and short course environments, the system has also been used extensively to conduct basic image processing research. The flow of information through the system is discussed including an overview of the programs.

Jensen, J. R.↗

Two-level structural sparsity regularization for identifying lattices and defects in noisy images

Here, this paper presents a regularized regression model with a two-level structural sparsity penalty applied to locate individual atoms in a noisy scanning transmission electron microscopy image (STEM). In crystals, the locations of atoms is symmetric, condensed into a few lattice groups. Therefore, by identifying the underlying lattice in a given image, individual atoms can be accurately located. We propose to formulate the identification of the lattice groups as a sparse group selection problem. Furthermore, real atomic scale images contain defects and vacancies, so atomic identification based solely on a lattice group may result in false positives and false negatives. To minimize error, model includes an individual sparsity regularization in addition to the group sparsity for a within-group selection, which results in a regression model with a two-level sparsity regularization. We propose a modification of the group orthogonal matching pursuit (gOMP) algorithm with a thresholding step to solve the atom finding problem. The convergence and statistical analyses of the proposed algorithm are presented. The proposed algorithm is also evaluated through numerical experiments with simulated images. The applicability of the algorithm on determination of atom structures and identification of imaging distortions and atomic defects was demonstrated using three real STEM images. In conclusion, we believe this is an important step toward automatic phase identification and assignment with the advent of genomic databases for materials.

36 MATERIALS SCIENCE↗

Path-Based Dictionary Augmentation: A Framework for Improving $k$ -Sparse Image Processing

In this study, we have previously shown that augmenting orthogonal matching pursuit (OMP) with an additional step in the identification stage of each pursuit iteration yields improved $k$ -sparse reconstruction and denoising performance relative to baseline OMP. At each iteration a “path” or geodesic, is generated between the two dictionary atoms that are most correlated with the residual and from this path a new atom that has a greater correlation to the residual than either of the two bracketing atoms is selected. Here, we provide new computational results illustrating improvements in sparse coding and denoising on canonical datasets using both learned and structured dictionaries. The two methods of constructing a path are investigated for each dictionary type: the Euclidean geodesic formed by a linear combination of the two atoms and the 2-Wasserstein geodesic corresponding to the optimal transport map between the atoms. We prove here the existence of a higher-correlation atom in the Euclidean case under assumptions on the two bracketing atoms and introduce algorithmic modifications to improve the likelihood that the bracketing atoms meet those conditions. Although, we demonstrate our augmentation on OMP alone, in general it may be applied to any reconstruction algorithm that relies on the selection and sorting of high-similarity atoms during an analysis or identification phase.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-323: The FLUKA Monte Carlo Code in Ion Beam Therapy

Purpose: Monte Carlo (MC) codes are increasingly used in the ion beam therapy community due to their detailed description of radiation transport and interaction with matter. The suitability of a MC code demands accurate and reliable physical models for the transport and the interaction of all components of the mixed radiation field. This contribution will address an overview of the recent developments in the FLUKA code oriented to its application in ion beam therapy. Methods: FLUKA is a general purpose MC code which allows the calculations of particle transport and interactions with matter, covering an extended range of applications. The user can manage the code through a graphic interface (FLAIR) developed using the Python programming language. Results: This contribution will present recent refinements in the description of the ionization processes and comparisons between FLUKA results and experimental data of ion beam therapy facilities. Moreover, several validations of the largely improved FLUKA nuclear models for imaging application to treatment monitoring will be shown. The complex calculation of prompt gamma ray emission compares favorably with experimental data and can be considered adequate for the intended applications. New features in the modeling of proton induced nuclear interactions also provide reliable cross section predictions for the production of radionuclides. Of great interest for the community are the developments introduced in FLAIR. The most recent efforts concern the capability of importing computed-tomography images in order to build automatically patient geometries and the implementation of different types of existing positron-emission-tomography scanner devices for imaging applications. Conclusion: The FLUA code has been already chosen as reference MC code in many ion beam therapy centers, and is being continuously improved in order to match the needs of ion beam therapy applications. Parts of this work have been supported by the European FP7 project ENVISION (grant agreement no. 241851)

07 ISOTOPE AND RADIATION SOURCES↗

Limited-view 3D Imaging Technology or “LV 3D Imaging” Technology Assessment

Limited View 3D or “LV 3D” imaging is important because it addresses a technology gap that has life, time, radiation dose and monetary-saving impacts. It provides something that currently does not exist and its potential products open a variety of technology domains in which SRNL could become competitive in. It can become a low cost, safer and alternative approach to conducting what is commonly referred to as computer tomographic imaging. This project develops a bucket list of technologies that will be needed to develop a portable system for conducting LV 3D imaging.

47 OTHER INSTRUMENTATION↗

Extremal Problem for the Area of the Image of a Disk

We study metric properties of ring Q-homeomorphisms with respect to the p-modulus, p > 2, in the complex plane and establish lower bounds for the areas of disks. An extremal problem concerning minimization of the area functional is also solved.

97 MATHEMATICS AND COMPUTING↗

Limited-view 3D Imaging Technology or “LV 3D Imaging” Technology Assessment

Limited View 3D or “LV 3D” imaging is important because it addresses a tech nology gap that has life, time, radiation dose and monetary-saving impacts. It provides something that currently does not exist and its potential products open a variety of technology domains in which SRNL could become competitive in. It can become a low cost, safer and alternative approach to conducting what is commonly referred to as computer tomographic imaging. This project develops a bucket list of technologies that will be needed to develop a portable system for conducting LV 3D imaging.

47 OTHER INSTRUMENTATION↗

Machine learning to analyze images of shocked materials for precise and accurate measurements

A supervised machine learning algorithm, called locally adaptive discriminant analysis (LADA), has been developed to locate boundaries between identifiable image features that have varying intensities. LADA is an adaptation of image segmentation, which includes techniques that find the positions of image features (classes) using statistical intensity distributions for each class in the image. In order to place a pixel in the proper class, LADA considers the intensity at that pixel and the distribution of intensities in local (nearby) pixels. This paper presents the use of LADA to provide, with statistical uncertainties, the positions and shapes of features within ultrafast images of shock waves. We demonstrate the ability to locate image features including crystals, density changes associated with shock waves, and material jetting caused by shock waves. This algorithm can analyze images that exhibit a wide range of physical phenomena because it does not rely on comparison to a model. LADA enables analysis of images from shock physics with statistical rigor independent of underlying models or simulations.

47 OTHER INSTRUMENTATION↗

Tumor Microenvironment Targeting Nano–Bio Emulsion for Synergistic Combinational X-Ray PDT with Oncolytic Bacteria Therapy

Various cancer therapies have been developed, but tumor recurrence with incomplete tumor killing and remaining tumor cells/tissues is frequent in monotherapies. Herein, a nano–bio therapeutic emulsion formulated with multifunctional nanoscintillators and anaerobic Clostridium novyi-NT spores for synergistic image-guided combinational cancer therapy is reported. MRI visible nanoscintillators (NSs) are synthesized with a NaGdF 4 :Tb,Ce@NaGdF 4 core/shell structure for an image-guided X-ray photodynamic therapy (PDT) of the normoxic peripheral tumor. An anaerobic oncolytic bacterium (C. novyi-NT) therapy is combined to treat the hypoxic central tumor tissues. Photosensitizer-coated NSs (PS-NSs) and C. novyi-NT spores are emulsified with clinically available ethiodized oil (Lipiodol) to be the nano–bio therapeutic emulsion and injected into the tumor with computed tomography image guidance. The distribution of nano–bio therapeutic emulsion, including PS-NSs and anaerobic C. novyi-NT spores in the tumor site, is confirmed by both X-ray and T1-weighted magnetic resonance imaging. Following the image-guided X-ray PDT and anaerobic C. novyi- NT combination treatment, apoptotic cell death in cancer tissues, including both peripheral and central tumor regions, is significantly higher than in the control groups. Finally, this combination therapy approach using a nano–bio therapeutic emulsion is expected to overcome the limitations of conventional cancer therapy, resulting in increased cancer-therapeutic efficacy.

60 APPLIED LIFE SCIENCES↗

PANTHER. Pattern ANalytics To support High-performance Exploitation and Reasoning.

Sandia has approached the analysis of big datasets with an integrated methodology that uses computer science, image processing, and human factors to exploit critical patterns and relationships in large datasets despite the variety and rapidity of information. The work is part of a three-year LDRD Grand Challenge called PANTHER (Pattern ANalytics To support High-performance Exploitation and Reasoning). To maximize data analysis capability, Sandia pursued scientific advances across three key technical domains: (1) geospatial-temporal feature extraction via image segmentation and classification; (2) geospatial-temporal analysis capabilities tailored to identify and process new signatures more efficiently; and (3) domain- relevant models of human perception and cognition informing the design of analytic systems. Our integrated results include advances in geographical information systems (GIS) in which we discover activity patterns in noisy, spatial-temporal datasets using geospatial-temporal semantic graphs. We employed computational geometry and machine learning to allow us to extract and predict spatial-temporal patterns and outliers from large aircraft and maritime trajectory datasets. We automatically extracted static and ephemeral features from real, noisy synthetic aperture radar imagery for ingestion into a geospatial-temporal semantic graph. We worked with analysts and investigated analytic workflows to (1) determine how experiential knowledge evolves and is deployed in high-demand, high-throughput visual search workflows, and (2) better understand visual search performance and attention. Through PANTHER, Sandia's fundamental rethinking of key aspects of geospatial data analysis permits the extraction of much richer information from large amounts of data. The project results enable analysts to examine mountains of historical and current data that would otherwise go untouched, while also gaining meaningful, measurable, and defensible insights into overlooked relationships and patterns. The capability is directly relevant to the nation's nonproliferation remote-sensing activities and has broad national security applications for military and intelligence- gathering organizations.

58 GEOSCIENCES↗

Patient position alters attenuation effects in multipinhole cardiac SPECT

Purpose: Dedicated cardiac cameras offer improved sensitivity over conventional SPECT cameras. Sensitivity gains are obtained by large numbers of detectors and novel collimator arrangements such as an array of multiple pinholes that focus on the heart. Pinholes lead to variable amounts of attenuation as a source is moved within the camera field of view. This study evaluated the effects of this variable attenuation on myocardial SPECT images. Methods: Computer simulations were performed for a set of nine point sources distributed in the left ventricular wall (LV). Sources were placed at the location of the heart in both an anthropomorphic and a water-cylinder computer phantom. Sources were translated in x, y, and z by up to 5 cm from the center. Projections were simulated with and without attenuation and the changes in attenuation were compared. A LV with an inferior wall defect was also simulated in both phantoms over the same range of positions. Real camera data were acquired on a Discovery NM530c camera (GE Healthcare, Haifa, Israel) for five min in list-mode using an anthropomorphic phantom (DataSpectrum, Durham, NC) with 100 MBq of Tc-99m in the LV. Images were taken over the same range of positions as the simulations and were compared based on the summed perfusion score (SPS), defect width, and apparent defect uptake for each position. Results: Point sources in the water phantom showed absolute changes in attenuation of ≤8% over the range of positions and relative changes of ≤5% compared to the apex. In the anthropomorphic computer simulations, absolute change increased to 20%. The changes in relative attenuation caused a change in SPS of <1.5 for the water phantom but up to 4.2 in the anthropomorphic phantom. Changes were larger for axial than for transverse translations. These results were supported by SPS changes of up to six seen in the physical anthropomorphic phantom for axial translations. Defect width was also seen to significantly increase. The position-dependent changes were removed with attenuation correction. Conclusions: Translation of a source relative to a multipinhole camera caused only small changes in homogeneous phantoms with SPS changing <1.5. Inhomogeneous attenuating media cause much larger changes to occur when the source is translated. Changes in SPS of up to six were seen in an anthropomorphic phantom for axial translations. Attenuation correction removes the position-dependent changes in attenuation.

60 APPLIED LIFE SCIENCES↗

Evaluation of Alternate Concepts for Synthetic Vision Flight Displays With Weather-Penetrating Sensor Image Inserts During Simulated Landing Approaches

A simulation study was conducted in 1994 at Langley Research Center that used 12 commercial airline pilots repeatedly flying complex Microwave Landing System (MLS)-type approaches to parallel runways under Category IIIc weather conditions. Two sensor insert concepts of 'Synthetic Vision Systems' (SVS) were used in the simulated flights, with a more conventional electro-optical display (similar to a Head-Up Display with raster capability for sensor imagery), flown under less restrictive visibility conditions, used as a control condition. The SVS concepts combined the sensor imagery with a computer-generated image (CGI) of an out-the-window scene based on an onboard airport database. Various scenarios involving runway traffic incursions (taxiing aircraft and parked fuel trucks) and navigational system position errors (both static and dynamic) were used to assess the pilots' ability to manage the approach task with the display concepts. The two SVS sensor insert concepts contrasted the simple overlay of sensor imagery on the CGI scene without additional image processing (the SV display) to the complex integration (the AV display) of the CGI scene with pilot-decision aiding using both object and edge detection techniques for detection of obstacle conflicts and runway alignment errors.

Parrish, Russell V.↗

A fast marine sewage detection method for remote-sensing image

This paper presents an effective method for marine sewage detection from a remote-sensing image. It is inspired by the Grab-Cut mechanism that iterative estimation and incomplete labeling allow a considerably reduced degree of user interaction for a given quality of result. By establishing the relationship between the color feature and the object seeds, we first model object and background with Gaussian mixture model, respectively, followed by iteratively updating the parameter of model to decline the energy function. To improve the computation efficiency, we propose to extend the region of interest as background. The proposed method accounts for not only the effect of color feature, but also the geographical information. The experimental results demonstrate that the proposed method is more reliable in marine sewage detection compared to other state-of-the-art methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗