Search NASA⌕ Search

SEARCH · Search NASA

Results for “conditional shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

New Accessory for Cleaning the Inside of the Machine Tool Cavity

The best way to extend the life of a metalworking fluid (MWF) is to make sure the machine tool and MWF delivery system are properly cleaned at least once per year. The dilemma the MWF manager is faced with is: How does one clean the machine tool and the MWF system on a large machine tool with an enclosure in a timely manner without impacting production schedules? Remember the walls and roof of the machine enclosure are coated with a film of dried contaminated MWF that must also be removed. If not removed, the deposits on these surfaces can recontaminate the fresh charge of MWF. I have found a product that with this revised procedure helps to shorten the machine tool down time involved with machine cleaning. (1) Discuss with your MWF supplier if they have a machine cleaning product that can be used with your current water based MWF during normal machining operations. Most MWF manufacturers have a machine cleaner that can be used at a lower concentration (1-2% vs. 5%) and can be used while still making production parts for a short period of time (usually 24-48 hours). (2) Make sure this machine cleaner is compatible with the work-piece material you are machining into product. Most cleaners are compatible with ferrous alloys. Because of the increased alkalinity of the fluid you might experience staining if you are machining copper or aluminum alloys. (3) Remove the chips from the chips pans and fluid channels. (4) During off shift hours circulate the MWF using a new product marketed by Rego-Fix called a 'Hydroball'. This device has a 5/8 inch diameter straight shank which allows it to be installed in any collet or solid quick change tool holder. It has multiple nozzles so that the user can control the spray pattern generated when the MWF is circulated. It allows the user to utilize the high pressure, through spindle MWF delivery capability of your machine tool for cleaning purposes. The high pressure MWF system can now be effectively used for cleaning purposes. This will also work with standard pressure system but you must reduce the number of nozzles utilized. By combining the movement of the machine axis around the operating envelope and the MWF circulation you can do a reasonably effective job of washing the inside of the machine tool operating cavity. Way covers will be moved and surfaces exposed because of axis movement. Spray direction will change to better wash fixtures and machine tool components. Deposits will start to breakdown and be washed into the machine tool sump. Since the cycle will run four or more hours it can be done with a weaker cleaning solution. The distributor states that the unit can be rotated up to 50 RPM. When running it has the same effect as the washing rotor inside of your home dishwasher. Inside the cavity on a machining center there is a lot of splash. During normal operations, MWF deposits buildup on the walls and roof of the enclosures. If these deposits (containing bacteria, mold and other contaminants) are not removed they will inoculate the fresh charge of MWF when they are resaturated. When you clean the inside of machine tool cavity, time is spent removing these deposits on the walls and roof of the enclosure. Getting to these surfaces is very difficult usually requiring that a member of the cleaning crew get inside the machine tool to reach them. The Hydro ball is effective in distributing the cleaning solution on all surfaces of the enclosure under high pressure. The only negative we have found is you get to find all the gaps and leaks in your machine tool enclosure. By running the hydro ball with the machine cleaner enriched MWF during off shift (4-8 hours) you can effectively remove these deposits and buildups on the internal surfaces of the cavity of the machine tool and wash them down into the sump. You also clean the internal components of the MWF system without interrupting normal scheduled work. (5) Pump out the spent MWF. You will have found that most of the deposits have been washed from the internal surfaces of the enclosure. For extremely dirty machines you might have to refill the machine tool with the normal machine cleaner mix. You will find that even heavy deposits will break down quicker because of this pre-wash cycle. (6) Rinse the machine cavity. (7) Clean the walls, bottom and screens in the MWF reservoir. The use of this tool and the dilute machine cleaner reduced the cleaning time considerately without affecting production schedules. (8) Refill with MWF and resume normal operations. What we like about this system is we can schedule these light cleanings just before a scheduled fluid change. Add the cleaner to the mix and run the Hydroball on second shift. The spent fluid is pumped out on third shift and the machine refilled. The machine tool with a fresh charge of MWF is ready for first shift without interrupting production schedules. We get better life from our MWFs and the machinists are happier about the condition of their machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-scale simulations of wind farm performance with complex terrain and weather events

Predicting the response of wind farms to local weather is necessary for optimal design and operation. In this work, simulation and analysis of a frontal passage through a utility scale wind farm is achieved for the first time using a seamless multi-scale modeling approach. A generalized actuator disk (GAD) wind turbine model is used to represent turbine wakes, and results are compared to novel radar observations during the frontal passage. The Weather Research and Forecasting (WRF) model is employed with a nested grid setup that allows for coupling between multi-scale atmospheric conditions and turbine response. Starting with mesoscale forcing, the atmosphere is dynamically downscaled to the region of interest, where the interaction between turbulent flows and individual wind turbines is simulated with the GAD at10 m resolution. Several improvements are made to the GAD model to mimic realistic turbine operation, including a yawing capability and a power output calculation. Ultimately, the model is able to capture both the dynamics of the frontal passage and the turbine response; predictions show good agreement with observed turbine wake structure, velocity deficit, and power output after accounting for a phase shift in the mesoscale forcing. This study demonstrates the utility of the WRF-GAD framework for simulating wind farm performance under complex atmospheric conditions.

17 WIND ENERGY↗

Pre-Combustion Carbon Capture by a Nanoporous, Superhydrophobic Membrane Contactor Process

This report summarizes progress made during Phase I and Phase II of the project: "Pre-Combustion Carbon Capture by a Nanoporous, Superhydrophobic Membrane Contactor Process," under contract DE-FE-0000646. The objective of this project is to develop a practical and cost effective technology for CO 2 separation and capture for pre-combustion coal-based gasification plants using a membrane contactor/solvent absorption process. The goals of this technology development project are to separate and capture at least 90% of the CO 2 from Integrated Gasification Combined Cycle (IGCC) power plants with less than 10% increase in the cost of energy services. Unlike conventional gas separation membranes, the membrane contactor is a novel gas separation process based on the gas/liquid membrane concept. The membrane contactor is an advanced mass transfer device that operates with liquid on one side of the membrane and gas on the other. The membrane contactor can operate with pressures that are almost the same on both sides of the membrane, whereas the gas separation membranes use the differential pressure across the membrane as driving force for separation. The driving force for separation for the membrane contactor process is the chemical potential difference of CO 2 in the gas phase and in the absorption liquid. This process is thus easily tailored to suit the needs for pre-combustion separation and capture of CO 2 . Gas Technology Institute (GTI) and PoroGen Corporation (PGC) have developed a novel hollow fiber membrane technology that is based on chemically and thermally resistant commercial engineered polymer poly(ether ether ketone) or PEEK. The PEEK membrane material used in the membrane contactor during this technology development program is a high temperature engineered plastic that is virtually non-destructible under the operating conditions encountered in typical gas absorption applications. It can withstand contact with most of the common treating solvents. GTI and PGC have developed a nanoporous and superhydrophobic PEEK-based hollow fiber membrane contactor tailored for the membrane contactor/solvent absorption application for syngas cleanup. The membrane contactor modules were scaled up to 8-inch diameter commercial size modules. We have performing extensive laboratory and bench testing using pure gases, simulated water-gas-shifted (WGS) syngas stream, and a slipstream from a gasification derived syngas from GTI's Flex-Fuel Test Facility (FFTF) gasification plant under commercially relevant conditions. The team have also carried out an engineering and economic analysis of the membrane contactor process to evaluate the economics of this technology and its commercial potential. Our test results have shown that 90% CO 2 capture can be achieved with several physical solvents such as water and chilled methanol. The rate of CO 2 removal by the membrane contactor is in the range of 1.5 to 2.0 kg/m 2 /hr depending on the operating pressures and temperatures and depending on the solvents used. The final economic analysis has shown that the membrane contactor process will cause the cost of electricity to increase by 21% from the base plant without CO 2 capture. The goal of 10% increase in levelized cost of electricity (LCOE) from base DOE Case 1(base plant without capture) is not achieved by using the membrane contactor. However, the 21% increase in LCOE is a substantial improvement as compared with the 31.6% increase in LCOE as in DOE Case 2(state of art capture technology using 2-stages of Selexol TM ).

01 COAL, LIGNITE, AND PEAT↗

A reactive separation process for pre-combustion CO 2 capture employing oxygen-blown coal gasifier off-gas

In this paper, we present an experimental study of a reactive separation system, consisting of a membrane reactor (MR) and an adsorptive reactor (AR) operating in tandem, with the MR’s reject stream serving as the AR’s feed. We investigates the feasibility of applying this MR-AR system for high-purity H 2 production and simultaneous CO 2 capture via the water gas shift (WGS) reaction in the context of Integrated Gas Combined Cycle (IGCC) power generation employing oxygen-blown gasifier syngas from biomass and coal. We previously studied this MR-AR system for the IGCC process employing air-blown gasifier syngas, for which it demonstrated good performance, attaining high conversion exceeding equilibrium, producing ultra-pure H 2 for power generation, and a CO 2 stream ready for sequestration. In this study, we focus on oxygen-blown gasifier off-gas that contains no N 2 , with composition distinctly different from the air-blown gasifier syngas which has a large N 2 content. We employ a carbon molecular sieve membrane (CMSM), a commercial sour-shift WGS catalyst, and a hydrotalcite (HTC) adsorbent. We carried out experiments to determine membrane performance and to identify promising operating conditions in an IGCC-relevant environment. The CMSM proved robust during a long-term (~344 hr run) experimental run under high temperature and pressure maintaining a high He/N 2 selectivity (~170). Multi-cycle runs were carried out during which the MR-AR system displayed superior performance to that of a PBR, by producing a high purity H 2 product directly usable in power generation. Therefore, the findings from this study demonstrate the ability of the MR-AR system to operate stably for a broad range of gasifier off-gas compositions, and indicate its potential for integration into IGCC plants for power generation with CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

Mechanism of the Anticoagulant Activity of Thrombin Mutant W215A/E217A

The thrombin mutant W215A/E217A (WE) is a potent anticoagulant both in vitro and in vivo. Previous x-ray structural studies have shown that WE assumes a partially collapsed conformation that is similar to the inactive E* form, which explains its drastically reduced activity toward substrate. Whether this collapsed conformation is genuine, rather than the result of crystal packing or the mutation introduced in the critical 215-217 {beta}-strand, and whether binding of thrombomodulin to exosite I can allosterically shift the E* form to the active E form to restore activity toward protein C are issues of considerable mechanistic importance to improve the design of an anticoagulant thrombin mutant for therapeutic applications. Here we present four crystal structures of WE in the human and murine forms that confirm the collapsed conformation reported previously under different experimental conditions and crystal packing. We also present structures of human and murine WE bound to exosite I with a fragment of the platelet receptor PAR1, which is unable to shift WE to the E form. These structural findings, along with kinetic and calorimetry data, indicate that WE is strongly stabilized in the E* form and explain why binding of ligands to exosite I has only a modest effect on the E*-E equilibrium for this mutant. The E* {yields} E transition requires the combined binding of thrombomodulin and protein C and restores activity of the mutant WE in the anticoagulant pathway.

36 MATERIALS SCIENCE↗

Three-dimensional assemblies built up by quantum dots in size-quantization regime: Band gap shifts due to size-distribution of cadmium selenide nanoparticles

In the present study, it is predicted that the band gap energy of a three-dimensional quantum dot assembly exhibits a red shift when the dispersion of the crystal size distribution is enlarged, even at a fixed average value thereof. The effect is manifested when the size quantization regime in individual quantum dots constituting the assembly has been entered. Under the same conditions, the sub-band gap absorption tails are characterized with large Urbach energies, which could be one or two orders of magnitude larger than the value characteristic for the non-quantized case. - Graphical abstract: Band gap shifts due to size-distribution of nanoparticles in 3D assemblies built up by quantum dots in size-quantization regime. Display Omitted - Highlights: • Optical absorption of 3D QD assemblies in size-quantization regime is modeled. • Band gap energy of the QD solid depends on the size-distribution of the nanoparticles. • QD solid samples with same 〈R〉 exhibit band gap shift depending on size distribution. • QD size distribution leads to large Urbach energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Intensified inundation shifts a freshwater wetland from a CO 2 sink to a source

Abstract Climate change has altered global precipitation patterns and has led to greater variation in hydrological conditions. Wetlands are important globally for their soil carbon storage. Given that wetland carbon processes are primarily driven by hydrology, a comprehensive understanding of the effect of inundation is needed. In this study, we evaluated the effect of water level (WL) and inundation duration (ID) on carbon dioxide (CO 2 ) fluxes by analysing a 10‐year (2008–2017) eddy covariance dataset from a seasonally inundated freshwater marl prairie in the Everglades National Park. Both gross primary production (GPP) and ecosystem respiration (ER) rates showed declines under inundation. While GPP rates decreased almost linearly as WL and ID increased, ER rates were less responsive to WL increase beyond 30 cm and extended inundation periods. The unequal responses between GPP and ER caused a weaker net ecosystem CO 2 sink strength as inundation intensity increased. Eventually, the ecosystem tended to become a net CO 2 source on a daily basis when either WL exceeded 46 cm or inundation lasted longer than 7 months. Particularly, with an extended period of high‐WLs in 2016 (i.e., WL remained >40 cm for >9 months), the ecosystem became a CO 2 source, as opposed to being a sink or neutral for CO 2 in other years. Furthermore, the extreme inundation in 2016 was followed by a 4‐month postinundation period with lower net ecosystem CO 2 uptake compared to other years. Given that inundation plays a key role in controlling ecosystem CO 2 balance, we suggest that a future with more intensive inundation caused by climate change or water management activities can weaken the CO 2 sink strength of the Everglades freshwater marl prairies and similar wetlands globally, creating a positive feedback to climate change.

Zhao, Junbin↗

Dynamics and potentials

A dynamics (i.e. a one-parameter group of automorphisms) of a system described by a C *-algebra with a local structure in terms of C *-subalgebras A (I ) for local domains I of the physical space (a discrete lattice) is normally constructed out of potentials P (I ), each of which is a self-adjoint element of the subalgebra A (I ), such that the the first time derivative of the dynamical change of any local observable A is i times the convergent sum of the commutator [ P (I ), A ] over all finite regions I. We will invert this relation under the assumption (obviously assumed in the usual approach) that local observables all have the first time derivative, i.e. we prove the existence of potentials for any given dynamics satisfying the above-stated condition. Furthermore, by imposing a further condition for the potential P (I ) to be chosen for each I that it does not have a portion which can be shifted to potentials for any proper subset of I, we also show (1) the existence, (2) uniqueness, (3) an automatic convergence property for the sum over I, and (4) a quite convenient property for the chosen potential. The so-obtained properties (3) and (4) are not assumed and are very useful, though they were never noticed nor used before. We consider a system of finite kinds of finite spins and fermions on a discrete lattice, local regions being all finite subsets of the lattice and all local algebras being full matrix algebras of finite dimensions. For all dynamics for which all elements of any local algebra is once time differentiable, we prove that there exist a system of potentials which describe the time derivative of the given dynamics by a convergent sum stated above. The fundamental technique for finding such potentials is a non-commutative expectation which is defined on the basis of a product state of the algebra. For each choice of a product state, we obtain one expectation which produces one set of potentials, all of which satisfy what we call the standardness condition and the convergence condition. We call this family of potentials standard potentials (corresponding to any specific choice of the product state). The standard potentials corresponding to different product states are different but produces the same time derivative, known as equivalent potentials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gold Code-Phase-Shift Keying: A Power and Bandwidth Efficient Communication Scheme for Smart Buildings

Advanced communications, sensors and controls play an important role in reducing the energy consumption of smart buildings. Wireless sensors have been recently deployed in buildings to provide monitoring and control of several devices such as heating, ventilation, and air-conditioning (HVAC) and lighting systems. In this paper, we present a low-power bandwidth-efficient communication scheme that can be driven by energy harvesting in self-powered wireless sensors. The proposed communication scheme is based on Gold code-phase-shift keying (CPSK) spread-spectrum signaling that improves both transmitter range and power consumption. We present our efforts toward exploring the design, implementation, and performance evaluation of a hardware prototypic Gold CPSK spread-spectrum radio transceiver. Experimental testing in addition to end-to-end system-level simulation-based studies are conducted to evaluate the performance of the Gold CPSK transceiver in terms of receiver sensitivity, coverage range, average probability of bit-error over standard Gaussian and Rayleigh fading-type channels, and multiple access capabilities. The specific engineering tradeoffs are also discussed.

Killough, Stephen M.↗

Multi-Scale Simulation of Wind Farm Performance during a Frontal Passage

Predicting the response of wind farms to changing flow conditions is necessary for optimal design and operation. Here in this work, simulation and analysis of a frontal passage through a utility scale wind farm is achieved for the first time using a seamless multi-scale modeling approach. A generalized actuator disk (GAD) wind turbine model is used to represent turbine–flow interaction, and results are compared to novel radar observations during the frontal passage. The Weather Research and Forecasting (WRF) model is employed with a nested grid setup that allows for coupling between multi-scale atmospheric conditions and turbine response. Starting with mesoscale forcing, the atmosphere is dynamically downscaled to the region of interest, where the interaction between turbulent flows and individual wind turbines is simulated with 10 m grid spacing. Several improvements are made to the GAD model to mimic realistic turbine operation, including a yawing capability and a power output calculation. Ultimately, the model is able to capture both the dynamics of the frontal passage and the turbine response; predictions show good agreement with observed background velocity, turbine wake structure, and power output after accounting for a phase shift in the mesoscale forcing. This study demonstrates the utility of the WRF-GAD model framework for simulating wind farm performance under complex atmospheric conditions.

17 WIND ENERGY↗

Isoprene Suppression by CO 2 Is Not Due to Triose Phosphate Utilization (TPU) Limitation

Isoprene is one of the most abundant volatile organic compounds produced by some, though not all, plant species. It confers stress tolerance in both emitting and non-emitting species and has large impacts on gene regulation as well as on atmospheric chemistry. Understanding the control of isoprene emission fromplants is important to understanding plant responses to future atmospheric conditions. Here, we confirmed that suppression of isoprene emission from plants by high CO 2 concentrations is reduced but not eliminated by high temperature. We tested whether the CO 2 suppression is caused by the reduction in ATP or NADPH availability caused by triose phosphate utilization (TPU) limitation of photosynthesis at high CO2. We measured CO 2 assimilation as well as several photosynthetic electron transport parameters under multiple atmospheric conditions in four plant species grown at ambient CO 2 . While CO 2 sensitivity of isoprene emission was somewhat correlated with TPU in some species, in other species it was not. Poplar exhibited significant CO 2 suppression of isoprene emission but no evidence for TPU so we investigated further, measuring the electrochromic shift that gives information on ATP synthesis and photosystem I oxidation state. In all cases photosynthetic parameters were unchanged while isoprene emission dropped in response to increasing CO 2 . Non-photorespiratory conditions (2% O 2 ) led to an increase in isoprene emission at low CO 2 but did not alleviate suppression by high CO 2 . In all measured species the combination of higher temperature along with higher CO 2 concentrations led to a net increase of isoprene emission in response to a moderate scenario for temperature and CO 2 concentration in 2100 in the upper Midwest.

54 ENVIRONMENTAL SCIENCES↗

A short tutorial on uranium electropolishing

Electropolishing of uranium metal is best performed in a simple aqueous solution of phosphoric acid. With +3 to +10 volts of bias potential applied to the uranium (anode) relative to a Pt counter electrode (cathode). As summarized in a Pourbaix stability diagram, these conditions yield dissolution of the U surface as UOX containing solution species without the possibility of injecting hydrogen into the metal surface. However, if the uranium is biased to negative potentials relative to the counter electrode then water may be reduced at the U surface and hydrogen gas becomes available for reaction with the U metal. The stability diagram may be modified if there are other complexing species present in solution and the potential scale shifted if a different metal is use for the counter electrode. These effects can be understood in a known way as long as solution and electrochemical cell conditions are recognized.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Statistical framework to assess long-term spatio-temporal climate changes: East River mountainous watershed case study

Abstract Evaluation of long-term temporal and spatial climatic change in mountainous regions is a critical challenge because of the interactive effects of multiple land and climatic factors and processes. Here we present the application of the statistical framework to the assessment of changes of climatic conditions, using data from 17 meteorological stations across the East River watershed near Crested Butte, Colorado, USA, and spanning the period from 1966 to 2021. The framework is developed based on (1) a time-series analysis of daily, monthly, and yearly averaged meteorological parameters (temperature, relative humidity, precipitation, wind speed, etc.), (2) evaluation and time series analysis of potential evapotranspiration (ET o ), actual evapotranspiration (ET), aridity index (AI), standard precipitation index (SPI) and standard precipitation-evapotranspiration index (SPEI), and (3) a temporal-spatial climatic zonation of the studied area based on the hierarchical clustering and PCA analysis of the SPEI, because the SPEI can be considered an integrative characteristic of the changes of climatic conditions. The Budyko model, with the application of the Penman–Monteith equation for the estimation of ET o , was used to determine the ET. The time series analysis of the AI is used to identify the periods with energy limited and water limited conditions. Hierarchical clustering of site locations for the three temporal segments of the SPEI showed a significant temporal-spatial shifts, indicating that dynamic climatic processes drive zonation patterns. Therefore, the watershed climatic zonation requires periodic re-evaluation based on the structural time series analysis of meteorological and water balance data.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Extreme Weather Impacts on Utility-scale Photovoltaic Plant Performance in the United States

The global energy system is undergoing significant changes, including a shift in energy generating technologies to more renewable energy sources. However, the dependence of renewable energy sources on local environmental conditions could also increase disruptions in service through exposures to compound, extreme weather events. By fusing three diverse datasets (operations and maintenance tickets, weather data, and production data), this analysis presents a novel methodology to identify and evaluate performance impacts arising from extreme weather events across diverse geographical regions. Text analysis of maintenance tickets identified snow, hurricanes, and storms as the leading extreme weather events affecting photovoltaic plants in the United States. Statistical techniques and machine learning were then implemented to identify the magnitude and variability of these extreme weather impacts on site performance. Impacts varied between event and non-event days, with snow events causing the greatest reductions in performance (54.5%), followed by hurricanes (12.6%) and storms (1.1%). Machine learning analysis identified key features in determining if a day is categorized as low performing, such as low irradiance, geographic location, weather features, and site size. The analysis improves our understanding of compound, extreme weather event impacts on photovoltaic systems, which can inform planning activities, especially as the industry continues to expand into new geographic and climatic regions around the world.

14 SOLAR ENERGY↗

Identification of a repressor and an activator of azoreductase gene expression in Pseudomonas putida and Xanthomonas oryzae

Highlights: • Transcriptional regulators of azoreductase of P. putida and X. oryzae were found. • They were named AzoPR (for P. putida) and AzoXR (for X. oryzae). • Despite 51% amino acid identity, AzoPR is a repressor, while AzoXR is an activator. • They respond differently to methyl red which acts as an inducer of gene expression. Genes responsible for the production of azoreductase enzymes in 2 gram-negative bacteria, the soil bacterium Pseudomonas putida (AzoP) and the plant pathogen Xanthomonas oryzae (AzoX), were identified. The deduced amino acid sequences of AzoP and AzoX, share 46% amino acid identity to each other. Two different bacterial transcription factors, a repressor (AzoPR) and an activator (AzoXR), in P. putida and X. oryzae, respectively, were found to be divergently oriented to their respective azoreductase genes. Both regulators are LysR-type transcriptional regulators (LTTR) that respond to the azo dye inducer, methyl red (MR). AzoPR represses transcription of azoP in P. putida, which is reversed when cells are exposed to MR. Interestingly, in X. oryzae, AzoXR positively regulates azoX transcription upon MR induction. Moreover, despite their similarity, with 51% amino acid sequence identity, azoPR and azoXR are expressed differently in response to MR. The transcription of azoPR is increased in a dye concentration-dependent manner, while azoXR transcription is constitutive and relatively higher than azoPR. Both regulators are autoregulatory. Gel mobility shift assays (EMSA) verified the binding between the regulators and their corresponding promoter regions. Additionally, binding only occurred under reduced conditions in the presence of 0.5 mM dithiothreitol (DTT), indicating that the proteins are active in their reduced form.

60 APPLIED LIFE SCIENCES↗

Effects of CO addition on the characteristics of laminar premixed CH{sub 4}/air opposed-jet flames

The effects of CO addition on the characteristics of premixed CH{sub 4}/air opposed-jet flames are investigated experimentally and numerically. Experimental measurements and numerical simulations of the flame front position, temperature, and velocity are performed in stoichiometric CH{sub 4}/CO/air opposed-jet flames with various CO contents in the fuel. Thermocouple is used for the determination of flame temperature, velocity measurement is made using particle image velocimetry (PIV), and the flame front position is measured by direct photograph as well as with laser-induced predissociative fluorescence (LIPF) of OH imaging techniques. The laminar burning velocity is calculated using the PREMIX code of Chemkin collection 3.5. The flame structures of the premixed stoichiometric CH{sub 4}/CO/air opposed-jet flames are simulated using the OPPDIF package with GRI-Mech 3.0 chemical kinetic mechanisms and detailed transport properties. The measured flame front position, temperature, and velocity of the stoichiometric CH{sub 4}/CO/air flames are closely predicted by the numerical calculations. Detailed analysis of the calculated chemical kinetic structures reveals that as the CO content in the fuel is increased from 0% to 80%, CO oxidation (R99) increases significantly and contributes to a significant level of heat-release rate. It is also shown that the laminar burning velocity reaches a maximum value (57.5 cm/s) at the condition of 80% of CO in the fuel. Based on the results of sensitivity analysis, the chemistry of CO consumption shifts to the dry oxidation kinetics when CO content is further increased over 80%. Comparison between the results of computed laminar burning velocity, flame temperature, CO consumption rate, and sensitivity analysis reveals that the effect of CO addition on the laminar burning velocity of the stoichiometric CH{sub 4}/CO/air flames is due mostly to the transition of the dominant chemical kinetic steps. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of COVID-19 related stay-at-home restrictions on residential electricity use and implications for future grid stability

“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗