Search NASA⌕ Search

SEARCH · Search NASA

Results for “constant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Current Source Inverter Based Large Constant Power Speed Ratio SPM Machine Drive for Traction Applications

A high-performance surface permanent magnet (SPM) machine drive with an extended constant power speed ratio is proposed using a current source inverter (CSI) for a traction application. The constant-power operation regions of an SPM machine can be extended in an appealing fashion by taking advantage of the output voltage boost capability of the CSI. The CSI is naturally a boost-type converter, in contrast to the voltage source inverter (VSI) which has buck-type characteristics. To investigate the value of the CSI voltage boost feature, a new traction motor with higher rated voltage and lower rated current has been designed and compared to the motor that would be used with a VSI. The lower CSI current makes it possible to reduce the mass of the inverter and output power cable, benefiting power density and cost reduction. The SPM machine is modeled in the synchronous reference frame including the effect of the ac filter capacitors at the CSI output terminals. The capability of extending the speed range of the proposed motor is verified via closed-form analysis and FEA simulation, and its performance characteristics are compared with those of a VSI-based SPM motor of the same type.

42 ENGINEERING↗

Design of a 100 kW Surface Permanent Magnet Machine with Wide Constant Power Speed Ratio for Traction Applications

Surface permanent magnet (SPM) machines are considered to be strong candidates for traction applications due to their high power density and high efficiency. By adopting fractional-slot concentrated windings, SPM machines can achieve a wide constant power speed range. A carbon fiber sleeve is applied to ensure the retainment of the magnets at high speed operating conditions. The purpose of this paper is to present the design of a high speed SPM machine for traction applications with 25 kW/Liter active power density and a wide constant-power speed range that is consistent with guidelines and targets presented in the Electrical and Electronics Technical Team Roadmap published by the US Department of Energy. The predicted electromagnetic performance and structural characteristics are presented based on both analytical and FEA results.

42 ENGINEERING↗

Optical constants measurements of liquids for modeling aerosolized threats

Spectroscopic identification of aerosolized chemical threats is challenging due to the complex nature of the photon/particle interaction, as well as the diversity of possible particle sizes, morphologies, and compositions. Constructing a database of laboratory - measured transmittance spectra that covers each permutation is not practical. However, calculation of the spectra using the measured optical constants as a function of wavenumber, n(?) and k(?), for each of the liquids and/or solids composing the aerosol particles provides a viable alternative. These synthetic spectra (vis-à-vis laboratory-measured spectra) can be used to identify chemicals of interest and subtract out background interferents in field measurements. Using a well-established multiple pathlength approach, we measure the optical constants n/k for liquids that may be found as chemical species of interest or common background interferents aerosolized in plumes. These measurements are also used to generate several test case aerosol synthetic spectra.

Lockwood, Schuyler↗

Impact of source-production revision on the dose-rate constant of {sup 131}Cs interstitial brachytherapy sources

Purpose: Since its introduction in 2004, the model CS-1 Rev.1 {sup 131}Cs source has been used in many radiation therapy clinics for prostate brachytherapy. In 2006, this source model underwent a Rev.2 production revision. The aim of this work was to investigate the dosimetric influences of the Rev.2 production revision using high-resolution photon spectrometry. Methods: Three CS-1 Rev.1 and three CS-1 Rev.2 {sup 131}Cs sources were used in this study. The relative photon energy spectrum emitted by each source in the transverse bisector of the source was measured using a high-resolution germanium detector designed for low-energy photon spectrometry. Based on the measured photon energy spectrum and the radioactivity distribution in the source, the dose-rate constant ({Lambda}) of each source was determined. The effects of the Rev.2 production revision were quantified by comparing the emitted photon energy spectra and the {Lambda} values determined for the sources manufactured before and after the production revision. Results: The relative photon energy spectrum originating from the principal emissions of {sup 131}Cs was found to be nearly identical before and after the Rev.2 revision. However, the portion of the spectrum originating from the production of fluorescent x rays in niobium, a trace element present in the source construction materials, was found to differ significantly between the Rev.1 and Rev.2 sources. The peak intensity of the Nb K{sub {alpha}} and Nb K{sub {beta}} fluorescent x rays from the Rev.2 source was approximately 35% of that from the Rev.1 source. Consequently, the nominal {Lambda} value of the Rev.2 source was found to be greater than that determined for the Rev.1 source by approximately 0.7%{+-}0.5%. Conclusions: A significant reduction (65%) in relative niobium fluorescent x-ray yield was observed in the Rev.2 {sup 131}Cs sources. The impact of this reduction on the dose-rate constant was found to be small, with a relative difference of less than 1%. This study demonstrates that photon spectrometry can be used as a sensitive and convenient tool for monitoring and for quantifying the dosimetric effects of brachytherapy source-production revisions. Because production revision can change both the geometry and the atomic composition of brachytherapy sources, its dosimetric impact should be carefully monitored and evaluated for each production revision.

60 APPLIED LIFE SCIENCES↗

Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion

Purpose: To develop a method to reconstruct an interior region-of-interest (ROI) image with sufficient accuracy that uses differentiated backprojection (DBP) projection onto convex sets (POCS) [H. Kudo et al., ''Tiny a priori knowledge solves the interior problem in computed tomography'', Phys. Med. Biol. 53, 2207-2231 (2008)] and a tiny knowledge that there exists a nearly piecewise constant subregion. Methods: The proposed method first employs filtered backprojection to reconstruct an image on which a tiny region P with a small variation in the pixel values is identified inside the ROI. Total variation minimization [H. Yu and G. Wang, ''Compressed sensing based interior tomography'', Phys. Med. Biol. 54, 2791-2805 (2009); W. Han et al., ''A general total variation minimization theorem for compressed sensing based interior tomography'', Int. J. Biomed. Imaging 2009, Article 125871 (2009)] is then employed to obtain pixel values in the subregion P, which serve as a priori knowledge in the next step. Finally, DBP-POCS is performed to reconstruct f(x,y) inside the ROI. Clinical data and the reconstructed image obtained by an x-ray computed tomography system (SOMATOM Definition; Siemens Healthcare) were used to validate the proposed method. The detector covers an object with a diameter of {approx}500 mm. The projection data were truncated either moderately to limit the detector coverage to diameter 350 mm of the object or severely to cover diameter 199 mm. Images were reconstructed using the proposed method. Results: The proposed method provided ROI images with correct pixel values in all areas except near the edge of the ROI. The coefficient of variation, i.e., the root mean square error divided by the mean pixel values, was less than 2.0% or 4.5% with the moderate or severe truncation cases, respectively, except near the boundary of the ROI. Conclusions: The proposed method allows for reconstructing interior ROI images with sufficient accuracy with a tiny knowledge that there exists a nearly piecewise constant subregion.

60 APPLIED LIFE SCIENCES↗

Four-dimensional dose distributions of step-and-shoot IMRT delivered with real-time tumor tracking for patients with irregular breathing: Constant dose rate vs dose rate regulation

Purpose: Dose-rate-regulated tracking (DRRT) is a tumor tracking strategy that programs the MLC to track the tumor under regular breathing and adapts to breathing irregularities during delivery using dose rate regulation. Constant-dose-rate tracking (CDRT) is a strategy that dynamically repositions the beam to account for intrafractional 3D target motion according to real-time information of target location obtained from an independent position monitoring system. The purpose of this study is to illustrate the differences in the effectiveness and delivery accuracy between these two tracking methods in the presence of breathing irregularities. Methods: Step-and-shoot IMRT plans optimized at a reference phase were extended to remaining phases to generate 10-phased 4D-IMRT plans using segment aperture morphing (SAM) algorithm, where both tumor displacement and deformation were considered. A SAM-based 4D plan has been demonstrated to provide better plan quality than plans not considering target deformation. However, delivering such a plan requires preprogramming of the MLC aperture sequence. Deliveries of the 4D plans using DRRT and CDRT tracking approaches were simulated assuming the breathing period is either shorter or longer than the planning day, for 4 IMRT cases: two lung and two pancreatic cases with maximum GTV centroid motion greater than 1 cm were selected. In DRRT, dose rate was regulated to speed up or slow down delivery as needed such that each planned segment is delivered at the planned breathing phase. In CDRT, MLC is separately controlled to follow the tumor motion, but dose rate was kept constant. In addition to breathing period change, effect of breathing amplitude variation on target and critical tissue dose distribution is also evaluated. Results: Delivery of preprogrammed 4D plans by the CDRT method resulted in an average of 5% increase in target dose and noticeable increase in organs at risk (OAR) dose when patient breathing is either 10% faster or slower than the planning day. In contrast, DRRT method showed less than 1% reduction in target dose and no noticeable change in OAR dose under the same breathing period irregularities. When {+-}20% variation of target motion amplitude was present as breathing irregularity, the two delivery methods show compatible plan quality if the dose distribution of CDRT delivery is renormalized. Conclusions: Delivery of 4D-IMRT treatment plans, stemmed from 3D step-and-shoot IMRT and preprogrammed using SAM algorithm, is simulated for two dynamic MLC-based real-time tumor tracking strategies: with and without dose-rate regulation. Comparison of cumulative dose distribution indicates that the preprogrammed 4D plan is more accurately and efficiently conformed using the DRRT strategy, as it compensates the interplay between patient breathing irregularity and tracking delivery without compromising the segment-weight modulation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-33: Air-Kerma Strength and Dose Rate Constant by the Full Monte Carlo Simulations

Purpose: In general, the air-kerma strength (Sk) has been determined by the energy weighting the photon energy fluence and the corresponding mass-energy absorption coefficient or mass-energy transfer coefficient. Kerma is an acronym for kinetic energy released per unit mass, defined as the sum of the initial kinetic energies of all the charged particles. Monte Carlo (MC) simulations can investigate the kinetic energy of the charged particles after photo interactions and sum the energy. The Sk of {sup 192}Ir source is obtained in the full MC simulation and finally the dose rate constant Λ is determine. Methods: MC simulations were performed using EGS5 with the microSelectron HDR v2 type of {sup 192}Ir source. The air-kerma rate obtained to sum the electron kinetic energy after photoelectric absorption or Compton scattering for transverse-axis distance from 1 to 120 cm with a 10 m diameter air phantom. Absorbed dose in water is simulated with a 30 cm diameter water phantom. The transport cut-off energy is 10 keV and primary photons from the source need two hundred and forty billion in the air-kerma rate and thirty billion in absorbed dose in water. Results: Sk is multiplied by the square of the distance in air-kerma rate and determined by fitting a linear function. The result of Sk is (2.7039±0.0085)*10-{sup −11} µGy m{sup 2} Bq{sup −1} s{sup −1}. Absorbed dose rate in water at 1 cm transverse-axis distance D(r{sub 0}, θ{sub 0}) is (3.0114±0.0015)*10{sup −11} cGy Bq{sup −1} s{sup −1}. Conclusion: From the results, dose rate constant Λ of the microSelectron HDR v2 type of {sup 192}Ir source is (1.1137±0.0035) cGy h{sup −1} U{sup −1} by the full MC simulations. The consensus value conΛ is (1.109±0.012) cGy h{sup −1} U{sup −1}. The result value is consistent with the consensus data conΛ.

60 APPLIED LIFE SCIENCES↗

Multimessenger constraints on the neutron-star equation of state and the Hubble constant

Observations of neutron-star mergers with distinct messengers, including gravitational waves and electromagnetic signals, can be used to study the behavior of matter denser than an atomic nucleus and to measure the expansion rate of the Universe as quantified by the Hubble constant. We performed a joint analysis of the gravitational-wave event GW170817 with its electromagnetic counterparts AT2017gfo and GRB170817A, and the gravitational-wave event GW190425, both originating from neutron-star mergers. We combined these with previous measurements of pulsars using x-ray and radio observations, and nuclear-theory computations using chiral effective field theory, to constrain the neutron-star equation of state. We found that the radius of a 1.4–solar mass neutron star is 11.75 − 0.81 + 0.86 km at 90% confidence and the Hubble constant is 66.2 − 4.2 + 4.4 at 1σ uncertainty.

Dietrich, Tim↗

Constraints on the Hubble constant from supernova Refsdal’s reappearance

The Hubble constant measures the expansion rate of the Universe, but different methods give inconsistent values. Kelly et al. studied a supernova that had its light split into multiple images by the gravitational lensing of a foreground galaxy cluster. They combined measurements of the time delay between the multiple images with predictions made by multiple lensing models of the cluster. Furthermore, this approach allowed the authors to make a blinded measurement of the Hubble constant, finding a value that is more consistent with that derived from the cosmic microwave background than with the cosmic distance ladder.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of Spectroscopic Constants and Radiative Parameters for the B{sup 1}Π–X{sup 1}Σ{sup +} Electronic Transition of the LiCs Molecule

The spectroscopic constants (vibrational, rotational, and centrifugal) and the radiative parameters (Einstein coefficients for spontaneous emission, oscillator strengths for absorption, Franck–Condon factors, R{sub v'v'} centroids, and wavenumbers of rotational lines) of rovibronic transitions in the systems of bands B{sup 1}Π–X{sup 1}Σ{sup +} (0 ≤v'≤ 25, 0 ≤v'≤ 49, j = 0, 30, 50, 60, 70) of the LiCs molecule, as well as the radiative lifetimes of the excited electronic state, are calculated. Calculations are performed based on semiempirical potential curves constructed in this work. The calculated spectroscopic constants are compared with experimental values. The radiative lifetimes are calculated for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical Constants of an Apatite Single Crystal in the IR Range of 6–28 μm

On the basis of polarized IR-reflection spectra in the range of 5000–350 cm{sup –1} measured from the natural face of an optically transparent fluorapatite single crystal, components of a complex refractive index (optical constants) for radiation-vector orientations E ‖ c and E ⊥ c have been calculated by the Kramers–Kronig method. The fluorapatite single crystal has been chosen from several samples: it contains a minimum amount of impurities and has a high degree of crystallinity in accordance with the criteria of IR spectroscopy and Raman spectroscopy. Tabular data on optical constants for ordinary and extraordinary rays are given for the IR range of 6–28 μm. The obtained absorption spectra are compared with the results of quantum-chemical ab initio calculations within the B3LYP simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Construction of a dynamical matrix for an HCP crystal using phonon data at the symmetry points of the Brillouin zone and elastic constants

General analytical expressions are obtained for the dynamical matrix D(k) and the elastic constants C{sub ik} in an HCP crystal in terms of the Born-von Karman (BvK) parameters. An analytical method is proposed for constructing D(k) on the basis of data about the phonon frequencies {omega}{sub i}(N) at the symmetry points of the Brillouin zone and the elastic constants C{sub ik}. A number of relations between the values of {omega}{sub i}(N) and C{sub ik} are presented for conventional interaction models. It is shown that the standard method for determining BvK parameters by fitting them to experimental phonon spectra in HCP lattices is, as a rule, ambiguous, whereas the analytical method proposed allows one to find all the solutions of the problem. The methods developed are illustrated by the construction of dynamical matrices for Tb, Sc, Ti, and 0008.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superintegrability on N-dimensional spaces of constant curvature from so(N + 1) and its contractions

The Lie-Poisson algebra so(N + 1) and some of its contractions are used to construct a family of superintegrable Hamiltonians on the N-dimensional spherical, Euclidean, hyperbolic, Minkowskian, and (anti-)de Sitter spaces. We firstly present a Hamiltonian which is a superposition of an arbitrary central potential with N arbitrary centrifugal terms. Such a system is quasi-maximally superintegrable since this is endowed with 2N - 3 functionally independent constants of motion (plus the Hamiltonian). Secondly, we identify two maximally superintegrable Hamiltonians by choosing a specific central potential and finding at the same time the remaining integral. The former is the generalization of the Smorodinsky-Winternitz system to the above six spaces, while the latter is a generalization of the Kepler-Coulomb potential, for which the Laplace-Runge-Lenz N vector is also given. All the systems and constants of motion are explicitly expressed in a unified form in terms of ambient and polar coordinates as they are parametrized by two contraction parameters (curvature and signature of the metric).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear vertex constants and asymptotic normalization coefficients

The properties of nuclear vertex constants and of asymptotic normalization coefficients are considered along with methods for determining these quantities. Recent assertions in the literature that the properties of bound states cannot be extracted from phase shifts for a single partial wave are shown to be incorrect. A new method for determining vertex constants that employs both data of partial-wave analyses and analytic properties of scattering amplitudes is proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear vertex constants and asymptotic normalization coefficients for the tritium nucleus

The properties of the nuclear vertex constant for virtual triton decay to a deuteron and a neutron (T {sup {yields}} d + n) are investigated along with the properties of the asymptotic normalization coefficient defined for the triton wave function and related to this constant. These quantities are calculated numerically on the basis of an equation that relates the asymptotic normalization coefficient to the triton effective radius {rho}{sub T}, which was introduced in the present study. The values of G{sub T}{sup 2} = 1.244(68) fm and C{sub T}{sup 2} = 2.958(162) found from our calculations are in good agreement with experimental and theoretical estimates obtained for these quantities in other studies. Physical properties of the triton virtual state are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Superintegrability and higher-order constants for classical and quantum systems

We extend recent work by Tremblay, Turbiner, and Winternitz which analyzes an infinite family of solvable and integrable quantum systems in the plane, indexed by the positive parameter k. Key components of their analysis were to demonstrate that there are closed orbits in the corresponding classical system if k is rational, and for a number of examples there are generating quantum symmetries that are higher order differential operators than two. Indeed they conjectured that for a general class of potentials of this type, quantum constants of higher order should exist. We give credence to this conjecture by showing that for an even more general class of potentials in classicalmechanics, there are higher-order constants of the motion as polynomials in the momenta. Thus these systems are all superintegrable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear vertex constants for the virtual decay {sup 7}Be {yields} {sup 3}He + {sup 4}He of the 7Be bound states from a phase-shift analysis in the effective-range theory

The phase-shift-analysis data for the {sup 3}He{sup 4}He scattering are analyzed using the effective-range theory, with the Coulomb interaction taken into account. We find both the renormalized nuclear vertex constants for the vertex {sup 7}Be {yields} {sup 3}He + {sup 4}He in the ground (3/2{sup -}) and in the first excited (1/2{sup -}) bound states of {sup 7}Be, and the corresponding asymptotic normalization constants of the radial wave functions in these states. The results obtained can be used in an astrophysical S-factor calculation for radiative capture reaction {sup 4}He({sup 3}He, {gamma}){sup 7}Be.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constants of motion of the four-particle Calogero model

We present the explicit expressions of the complete set of constants of motion of four-particle Calogero model with excluded center of mass, i.e. of the A{sub 3} rational Calogero model. Then we find the constants of motion of its spherical part, defining two-dimensional 12-center spherical oscillator, with the force centers located at the vertexes of cuboctahedron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗