Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Microscope Would Image X and Gamma Rays

Microscope contains Bragg-reflecting, grazing-incidence reflectors, filter wheel, and detector. Multiple nested coaxial pairs of reflectors used to form images simultaneously at multiple wavelengths. Collects and focuses radiation to produce images with moderate spectral resolution and high spatial resolution. Enables use of smaller, cheaper, better-shielded detectors. Combination of features provides new information of unprecedented value in several fields of research; probing fine structures of pulsed plasmas, investigating minute variations in structures of material specimens penetrated only by hard-x or gamma rays, or in producing maps of distributions of radioisotopes in biological specimens.

Hoover, Richard B.↗

Calibration Improvements in the Detector-to-Detector Differences for the MODIS Ocean Color Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS), a major instrument within NASAs Earth Observation System missions, has operated for over 16 and 14 years onboard the Terra and Aqua satellites, respectively. Its reflective solar bands (RSB) covering a spectral range from 0.4 to 2.1 micrometers are primarily calibrated using the on-board solar diffuser(SD), with its on-orbit degradation monitored using the Solar Diffuser Stability Monitor. RSB calibrations are supplemented by near-monthly lunar measurements acquired from the instruments space-view port. Nine bands (bands 8-16) in the visible to near infrared spectral range from 0.412 to 0.866 micrometers are primarily used for ocean color observations.During a recent reprocessing of ocean color products, performed by the NASA Ocean Biology Processing Group, detector-to-detector differences of up to 1.5% were observed in bands 13-16 of Terra MODIS. This paper provides an overview of the current approach to characterize the MODIS detector-to-detector differences. An alternative methodology was developed to mitigate the observed impacts for bands 13-16. The results indicated an improvement in the detector residuals and in turn are expected to improve the MODIS ocean color products. This paper also discusses the limitations,subsequent enhancements, and the improvements planned for future MODIS calibration collections.

Li, Yonghong↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a single module of CUPID

CUPID is the next generation experiment which will use scintillating cryogenic calorimeters to search for the neutrinoless double β decay. This unobserved process would shed light on the nature of the neutrino, which up to our knowledge could be a Majorana or a Dirac particle, and would give us an important hint to explain the lack of antimatter in the universe. This ambitious search needs a detector with unique characteristics such as an extremely low background level and an excellent energy resolution. CUPID is now in advanced R&D state to optimize the detector design in order to completely exploit the potentialities of scintillating cryogenic calorimeters. In the following I will describe the test performed at the LNGS (Laboratori Nazionali del Gran Sasso) of a single module of the future CUPID detector. In this contribution we present the performance obtained with a novel assembly concept, proving that it matches the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Graph neural network for neutrino physics event reconstruction

Liquid argon time projection chamber (LArTPC) detector technology offers a wealth of high-resolution information on particle interactions, and leveraging that information to its full potential requires sophisticated automated reconstruction techniques. Here, this article describes NUGRAPH 2, a graph neural network for low-level reconstruction of simulated neutrino interactions in a LArTPC detector. Simulated neutrino interactions in the MicroBooNE detector geometry are described as heterogeneous graphs, with energy depositions on each detector plane forming nodes on planar subgraphs. The network utilizes a multihead attention message-passing mechanism to perform background filtering and semantic labeling on these graph nodes, identifying those associated with the primary physics interaction with 98.0% efficiency and labeling them according to particle type with 94.9% efficiency. The network operates directly on detector observables across multiple two-dimensional representations but utilizes a three-dimensional-context-aware mechanism to encourage consistency between these representations. Model inference takes 0.12 s / event on a CPU and 0.005 s / event batched on a GPU. This architecture is designed to be a general-purpose solution for particle reconstruction in neutrino physics, with the potential for deployment across a broad range of detector technologies, and offers a core convolution engine that can be leveraged for a variety of tasks beyond the two described in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TITUS: Visualization of Neutrino Events in Liquid Argon Time Projection Chambers

The amount and complexity of data recorded by high energy physics experiments are rapidly growing, and with these grow the difficulties in visualizing such data. To study the physics of neutrinos, a type of elementary particle, scientists use liquid argon time projection chamber (LArTPC) detectors, among other technologies. LArTPCs have a very high spatial resolution and resolve many of the elementary particles that come out of a neutrino interacting within the argon in the detector. Visualizing these neutrino interactions is of fundamental importance to understanding the properties of neutrinos, but also monitoring and checking on the detector conditions and operations. From these ideas, we have developed TITUS, an event display that shows images recorded by these neutrino detectors. TITUS is a piece of software that reads data coming from LArTPC detectors (as well as the corresponding simulation) and allows users to explore such data in multiple ways. TITUS is flexible to enable fast prototyping and customization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the primary cosmic electron spectrum from 10 to about 250-GeV

The intensity and energy spectrum of primary cosmic electrons from 10 to approximately 250 GeV was studied using balloon-borne detectors. Both of the detectors were large area ionization calorimeters with frequent sampling of showering particles and were capable of energy resolution of approximately 7%. A time-of-flight system and detectors to sample the lateral properties of showers were used to examine and improve background rejection. The results of the balloon flights from Alamogordo, N.M. in 1970 and Cape Girardeau, Missouri in 1972 indicated that the primary cosmic ray electron differential energy spectrum exhibits no change of slope in the energy range measured and is well represented by a power law. These results indicate that the cosmic electron spectrum is steeper than the cosmic ray proton spectrum. It is shown that these data are consistent with the leakage lifetime model for the propagation of cosmic electrons in the Galaxy, although other more complex models cannot be excluded on the basis of these data.

Silverberg, R. F.↗

Airborne imaging spectrometer II - The optical design

The Airborne Imaging Spectrometer (AIS I) was a multispectral infrared imaging instrument utilizing a 32 x 32 element mercury-cadmium-telluride detector array. A novel optical design provided high spectral resolution and, in conjunction with the 32-element spatial resolution, made optimal use of the capabilities of the area array. The operational successes of this proof-of-concept instrument, coupled with advances in infrared detector array technology, have provided the impetus and opportunity to upgrade the instrument by replacing the sensor with a newly developed 64 x 64 detector. The original instrument configuration is reviewed, and the design considerations, limitations and trade-offs necessitated by the new detector are examined, particularly the near doubling of the field of view and the increase from 1024 to 4096 pixels per read-out frame.

La Baw, Clayton↗

High-energy proton radiation damage of high-purity germanium detectors

Quantitative studies of radiation damage in high-purity germanium gamma-ray detectors due to high-energy charged particles have been carried out; two 1.0 cm thick planar detectors were irradiated by 6 GeV/c protons. Under proton bombardment, degradation in the energy resolution was found to begin below 7 x 10 to the 7th protons/sq cm and increased proportionately in both detectors until the experiment was terminated at a total flux of 5.7 x 10 to the 8th protons/sq cm, equivalent to about a six year exposure to cosmic-ray protons in space. At the end of the irradiation, the FWHM resolution measured at 1332 keV stood at 8.5 and 13.6 keV, with both detectors of only marginal utility as a spectrometer due to the severe tailing caused by charge trapping. Annealing these detectors after proton damage was found to be much easier than after neutron damage.

Pehl, R. H.↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mission Study for Generation-X: A Large Area and High Angular Observatory to Study the Early Universe

In this report we provide a summary of the technical progress achieved during the last year Generation-X Vision Mission Study. In addition, we provide a brief programmatic status. The Generation-X (Gen-X) Vision Mission Study investigates the science requirements, mission concepts and technology drivers for an X-ray telescope designed to study the new frontier of astrophysics: the birth and evolution of the first stars, galaxies and black holes in the early Universe. X-ray astronomy offers an opportunity to detect these via the activity of the black holes, and the supernova explosions and gamma-ray burst afterglows of the massive stars. However, such objects are beyond the grasp of current missions which are operating or even under development. Our team has conceived a Gen-X Vision Mission based on an X-ray observatory with 100 m2 collecting area at 1 keV (1000 times larger than Chandra) and 0.1 arcsecond angular resolution (several times better than Chandra and 50 times better than the Constellation-X resolution goal). Such a high energy observatory will be capable of detecting the earliest black holes and galaxies in the Universe, and will also study extremes of density, gravity, magnetic fields, and kinetic energy which cannot be created in laboratories. In our study we develop the mission concept and define candidate technologies and performance requirements for Gen-X. The baseline Gen-X mission involves four 8 m diameter X-ray telescopes operating at Sun-Earth L2. We trade against an alternate concept of a single 26 m diameter telescope with focal plane instruments on a separate spacecraft. A telescope of this size will require either robotic or human-assisted in-flight assembly. The required effective area implies that extremely lightweight grazing incidence X-ray optics must be developed. To achieve the required areal density of at least 100 times lower than for Chandra, we study 0.2 mm thick mirrors which have active on-orbit figure control. We also study the suite of required detectors, including a large FOV high angular resolution imager, a cryogenic imaging spectrometer and a reflection grating spectrometer.

Brissenden, Roger↗

Characterization of MODIS VIS/NIR Spectral Band Detector-to-Detector Difference

MODIS has 36 spectral bands with wavelengths in the visible (VIS), near-infrared (NIR), shortwave infrared (SWTR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). It makes observations at three nadir spatial resolutions: 0,25km for bands 1-2 with 40 detectors per band, 0.5km for bands 3-7 with 20 detectors per band, and 1km for bands 8-36 with 10 detectors per band. The VIS, NIR, and S\VIR spectral bands are the reflective solar bands (RSB), which are calibrated on-orbit by a solar diffuser (SD). In addition, MODIS lunar observations are used to track the RSB calibration stability. In this study, we examine detector-to-detector calibration difference for the VIStNIR spectral bands using the SD and lunar observations. The results will be compared with an independent analysis with additional information, such as polarization correction, derived from standard ocean color data products. The current MODIS RSB calibration approach only carries a band-averaged RVS (response versus scan angle) correction. The results from this study suggest that a detector-based RVS correction should be used to improve the L1B data quality, especially for several VIS bands in Terra MODIS due to large changes of the scan mirror's optical properties in recent years.

Xiong, X.↗

Exploring the Saturn System in the Thermal Infrared: The Composite Infrared Spectrometer

The Composite Inbred Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wave number, from 10 to 1400 cm (1 mm to 7pm), with a spectral resolution that can be set from 0.5 to 20 cm. The far in portion of the spectrum (10 - 600 cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600 - 1100cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. CIRS observations will provide three-dimensional maps of temperature, gas composition, and aerosols/condensates of the atmospheres of Titan and Saturn with good vertical and horizontal resolution, from deep in their tropospheres to high in their mesospheres. CIRS ability to observe atmospheres in the limb viewing mode (in addition to nadir) offers the opportunity to provide accurate and highly resolved vertical profiles of these atmospheric variables. The ability to observe with high-spectral resolution should facilitate the identification of new constituents. CIRS will also map the thermal and compositional properties of the surfaces of Saturn's icy satellites. It will similarly map Saturn's rings, characterizing their formation and evolution. The combination of broad spectral range, programmable spectral resolution, the small detector fields of view, and an orbiting spacecraft platform will allow CIRS to observe the Saturnian system in the thermal infrared at a level of detail not previously achieved.

Flasar, F. M.↗

The Generation-X X-ray Observatory Vision Mission and Technology Study

The new frontier in astrophysics is the study of the birth and evolution of the first stars, galaxies and black holes in the early Universe. X-ray astronomy opens a window into these objects by studying the emission from black holes, supernova explosions and the gamma-ray burst afterglows of massive stars. However, such objects are beyond the grasp of current or near-future observatories. X-ray imaging and spectroscopy of such distant objects will require an X-ray telescope with large collecting area and high angular resolution. Our team has conceived the Generation-X Vision Mission based on an X-ray observatory with 100 sq m collecting area at 1 keV (1000 times larger than Chandra) and 0.1 arcsecond angular resolution (several times better than Chandra and 50 times better than the Constellation-X resolution goal). Such an observatory would be capable of detecting the earliest black holes and galaxies in the Universe, and will also study extremes of density, gravity, magnetic fields, and kinetic energy which cannot be created in laboratories. NASA has selected the Generation-X mission for study under its Vision Mission Program. We describe the studies being performed to develop the mission concept and define candidate technologies and performance requirements for Generation-X. The baseline Generation-X mission involves four 8m diameter X-ray telescopes operating at Sun-Earth L2. We trade against an alternate concept of a single 26m diameter telescope with focal plane instruments on a separate spacecraft. A telescope of this size will require either robotic or human-assisted in-flight assembly. The required effective area implies that extremely lightweight grazing incidence X-ray optics must be developed. To achieve the required aerial density of at least 100 times lower than in Chandra, we will study 0.1mm thick mirrors which have active on-orbit figure control. We discuss the suite of required detectors, including a large FOV high angular resolution imager, a cryogenic imaging spectrometer and a grating spectrometer. We outline the development roadmap to confront the many technological challenges far implementing the Generation-X mission.

Figueroa-Feliciano, Enectali↗

Hybrid gas scintillation proportional counter/phoswich detector for hard X-ray astronomy

A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.

Grindlay, Jonathan E.↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

High-resolution surface temperature measurements on rotating turbine blades with an infrared pyrometer

A high-resolution pyrometer was developed and tested on a modified turbine engine. The pyrometer was used to obtain temperature profiles of the viewed surface of turbine blades in the engine at tip speeds up to 366 meters per second. The combination of coherent fiber optics, a silicon avalanche detector, and high-speed electronics enabled surface resolution of a spot diameter of 0.05 centimeter. The data, in the form of temperature profiles, was obtained in near real time as a hard copy output from a computer display terminal. Temperatures measured with the pyrometer and with thermocouples agreed within 2 percent at temperatures between 977 to 1144 K.

Uguccini, O. W.↗