Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Ultra-Compact Neuroprocessor for Automotive Diagnostic and Control

Demands on the performance of vehicle control and diagnostic systems are steadily increasing as a consequence of stiff global competition and government mandates. In the United States, light trucks and passenger cars are required both to meet strict emission standards and to perform continuous diagnostics of all emissions systems operating in the vehicle.

Neuroprocessor automotive diagnostics↗

Diagnostic Reasoning using Prognostic Information for Unmanned Aerial Systems

With increasing popularity of unmanned aircraft, continuous monitoring of their systems, software, and health status is becoming more and more important to ensure safe, correct, and efficient operation and fulfillment of missions. The paper presents integration of prognosis models and prognostic information with the R2U2 (REALIZABLE, RESPONSIVE, and UNOBTRUSIVE Unit) monitoring and diagnosis framework. This integration makes available statistically reliable health information predictions of the future at a much earlier time to enable autonomous decision making. The prognostic information can be used in the R2U2 model to improve diagnostic accuracy and enable decisions to be made at the present time to deal with events in the future. This will be an advancement over the current state of the art, where temporal logic observers can only do such valuation at the end of the time interval. Usefulness and effectiveness of this integrated diagnostics and prognostics framework was demonstrated using simulation experiments with the NASA Dragon Eye electric unmanned aircraft.

Diagnostics↗

Virtual Diagnostics Interface (ViDI) for Planning Laser-Based Wind Tunnel Experiments

Virtual Diagnostics Interface (ViDI), originally introduced by Richard Schwartz in 2004 and described again by Alderfer, et. al., in 2007, is an interactive 3D software tool developed at NASA Langley Research Center to serve three main purposes: assist in pre-test planning, enhance post-test image analysis and visualization, and serve as a central location for data storage and distribution.1,2 ViDI is composed of custom-developed software and Autodesk® 3ds Max® as it incorporates Computer Aided Design (CAD) models with the results obtained from optical diagnostics.3 This software tool has proven useful in the field of optical diagnostics where pre-test planning of beam paths, optical elements, and test articles must be carried out to avoid interference, ensure spatial resolution is sufficient, and the camera Field of View (FoV) is adequate for the field of interest. Typically, practical considerations such as the distance a camera is from the region of interest, the angles at which the camera is oriented and issues such as the size of the camera and its sensor and size and focal length lens as well as the path of the laser need to be taken into account to predict a successful measurement. An example application of ViDI is shown in Fig.1 where an experiment to investigate flow separation over the wing of the High Lift Common Research Model (HL-CRM) is currently being planned in the National Transonic Facility (NTF) at NASA Langley Research Center.

virtual diagnostics interface↗

Advanced Diagnostics for Megahertz Imaging of Mixing, Fuel Spray, and Combustion Processes for Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Advanced Diagnostics For Megahertz Imaging Of Mixing, Fuel Spray, And Combustion Processes For Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Assessment of ProgPy - An Open-Source Condition Monitoring and Diagnostics Tool

Traditional maintenance programs, such as corrective and preventive strategies, may lead to high costs and operational inefficiencies. Condition Monitoring and Diagnostics (CM&D) aims to improve these maintenance strategies by enabling timely insights into equipment health and performance. However, implementation of CM&D can be challenging without a robust framework that manages data efficiently, supports interoperability and simplifies integration. To address these challenges ProgPy, an open-source Python-based prognostics tool developed by NASA Ames Research Center, offers a structured solution for broader Prognostics and Health Management (PHM) applications. Ongoing research is assessing the feasibility of implementing ProgPy as a Condition Monitoring and Diagnostics (CM&D) solution by comparing its framework to the guidelines for open CM&D systems recommended in the ISO 13374-2 standard. This evaluation aims to highlight ProgPy’s strengths and identify opportunities for improvement, thereby, contributing to its advancement as an effective tool for Prognostics and Health Management (PHM). This paper presents the results of an initial assessment of the ProgPy toolbox through a gearbox case study using open-source datasets.

Condition-Monitoring, Diagnostics, Failure, Gearbo↗

Overview of the gamma reaction history diagnostic for the national ignition facility (NIF)

The National Ignition Facility (NIF) has a need for measuring gamma radiation as part of a nuclear diagnostic program. A new gamma-detection diagnostic uses 900 off-axis parabolic mirrors to rel ay Cherenkov light from a volume of pressurized gas. This non imaging optical system has the high-speed detector placed at a stop position with the Cherenkov light delayed until after the prompt gammas have passed through the detector. Because of the wavelength range (250 to 700 nm), the optical element surface finish was a key design constraint. A cluster of four channels (each set to a different gas pressure) will collect the time histories for different energy ranges of gammas.

42 ENGINEERING↗

Radiochemistry as a (rho)R Diagnostic with the RAGS Gas Collection System

Radiochemical diagnostic techniques such as gas-phase capsule debris analysis may prove to be successful methods for establishing the success or failure of ignition experiments at the National Ignition Facility (NIF). Samples in the gas phase offer the most direct method of collection by simply pumping out the large target chamber following a NIF shot. The target capsules will be prepared with dopants which will produce radioactive noble gas isotopes upon activation with neutrons. We have designed and constructed the Radchem Apparatus for Gas Sampling (RAGS) in order to collect post-shot gaseous samples for NIF capsule diagnostics. The design of RAGS incorporates multiple stages intended to purify, transfer, and count the radioactive decays from gaseous products synthesized in NIF experiments. At the moment the dopant of choice is {sup 124}Xe, which will undergo (n,{gamma}) and (n, 2n) reactions to produce {sup 125}Xe and {sup 123}Xe. The half-lives of each are on the order of multiple hours and are suitable for long-term gamma-counting. These isotopes and the rest of the gases evolved in a NIF shot will be drawn through the NIF turbo pumps, past the temporarily shuttered cryo pumps (to aid our collection efficiency), and towards the first main portion of the RAGS system: the pre-cleaner. The pre-cleaner will consist of a water removal system, a series of heated getter cartridges to remove most other impurities such as N{sub 2}, O{sub 2}, CO{sub 2}, etc., and a residual gas analyzer (RGA) to monitor vacuum quality. The noble gases will flow through the precleaner and into the second stage of the system: the cryo collector. This cryo collector consists of a main cryo head for noble gas collection which will operate for approximately five minutes post-shot. Afterwards a valve will close and isolate the pre-cleaner, while the cryo head warms to release the Xe gas to one of two locations - either a second cryo station for in-situ gamma counting, or to a small cooled gas bottle for removal and counting. Additional capabilities of the RAGS system include a noble gas calibration apparatus attached to the NIF target chamber, which will be operated hours pre-shot to determine collection efficiency through the whole RAGS system via the signal detected from the RGA. Also it is possible there will be the addition of a helium puff system to drive the Xe through the pre-cleaner and collection stations. It is also likely that multiple cryo collection stations will be built into the system in the future to fractionate and collect other noble gases such as Kr, Ar, and possibly Ne. A prototype pre-cleaner has been built at Lawrence Berkeley National Laboratory (LBNL) and is in the testing phases. The information learned in this testing will help collaborators at Sandia National Laboratory that are building and delivering the systems that will be deployed at NIF. The LBNL testing so far has demonstrated that radioactive fission gases can be flowed through the system with and without carrier gases of air and/or He, and the activity can be collected on an activated charcoal sample. Further testing in the upcoming months will hopefully yield more information about any presence of Xe in the water removed from the system, and commissioning of a small cryo cooler as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge Diagnostics for Laser Plasma Accelerators

The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1percent per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm2 and 0.4 pC/ps/mm2, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within +/-10 percent.

43 PARTICLE ACCELERATORS↗

Initial Evaluation of Engine Combustion Network Injectors with X-Ray Diagnostics

A significant hurdle in the understanding of diesel sprays is the sensitivity of such sprays to the detailed geometry of the spray nozzle. This sensitivity hampers the comparison of results from spray measurements by different research groups, even if the groups measure nozzles with the same nominal geometry. Moreover, these differences make the comparison and validation of different diagnostic techniques problematic. To remove this source of uncertainty from diesel spray measurements, a collaboration of several research groups has formed to measure a common set of injectors under identical conditions under the auspices of Sandia National Laboratorys Engine Combustion Network. The current work describes the initial measurement of these injectors and the sprays created by these injectors using the x-ray diagnostics available at the Advanced Photon Source. X-ray phase-enhanced imaging is used to perform time-resolved, in situ measurements of injector pintle motion. In addition to these measurements, x-ray radiography measurements of the sprays from these injectors will be performed to better understand the near-nozzle fuel mass distribution in these sprays.

43 PARTICLE ACCELERATORS↗

A Langmuir Probe Diagnostic for Use in Inhomogeneous, Time-Varying Plasmas Produced by High-Energy Laser Ablation

Langmuir probes (LP) are used extensively to characterize plasma environments produced by radio frequency, pulsed plasma thrusters, and laser ablation. We discuss here the development of a LP diagnostic to examine high-density, high-temperature inhomogeneous plasmas such as those that can be created at the University of Rochester's Laboratory for Laser Energetics OMEGA facility. We have configured our diagnostic to examine the velocity of the plasma expanding from the target. We observe velocities of approximately 16-17 cm/{micro}s, with individual LP currents displaying complex structures, perhaps due to the multiple atomic species and ionization states that exist.

47 OTHER INSTRUMENTATION↗

South pole bang-time diagnostic on the National Ignition Facility

The south pole bang-time (SPBT) diagnostic views National Ignition Facility (NIF) implosions through the lower hohlraum laser entrance hole to measure the time of peak x-ray emission (peak compression) in indirect drive implosions. Five chemical-vapor-deposition (CVD) diamond photoconductive detectors (PCD's) with different filtrations and sensitivities record the time-varying x rays emitted by the target. Wavelength-selecting highly oriented pyrolytic graphite (HOPG) crystal mirror monochromators increase the x-ray signal-to-background ratio by filtering for 11-keV emission. Diagnostic timing and the in-situ temporal instrument response function are determined from laser impulse shots on the NIF. After signal deconvolution and background removal, the bang time is determined to 45-ps accuracy. The x-ray 'yield' (mJ/sr/keV at 11 keV) is determined from the total area under the peak.

36 MATERIALS SCIENCE↗

Characterization of a theta-pinch plasma using triple probe diagnostic

Plasma diagnostics were carried out in a theta-pinch device to investigate the applicability for plasma-material interaction under fusion-like conditions. A series of triple probe diagnostics show that the plasma is sustained for approximately 80 {micro}s at each pulse, with 3.0 (10){sup 21} m{sup -3} plasma density and up to 40 eV electron temperature when a 32 {micro}F main capacitor is discharged at 20 kV. In order to increase plasma density and temperature, an RF antenna is installed near one end of a Pyrex tube and a 50 {micro}F preionization capacitor is connected to an electrode placed at the same end as the antenna. In this configuration, several time delays between the main and preionization capacitors are tested. When the preionization capacitor was triggered 45 {micro}s before the main bank discharge, it resulted in high energetic plasma being obtained with a few density spikes at 10{sup 22} m{sup -3} and electron temperature around 100 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online Monitoring To Enable Improved Diagnostics, Prognostics and Maintenance

Only time will tell what the implications of the Fukushima incident will be. Discussions are on-going with regard to continued operation and life extension of the existing fleet, new build, and the wider policy issues including technologies needed to address spent fuel storage and ensure energy security, and the related desires to provide sustainable energy systems while at the same time limiting greenhouse gas emissions. The science base for advanced diagnostics and prognostics to support its use in nuclear power plants (NPPs) for active components (pumps, valves etc) has been demonstrated. A challenge is enabling adaption of these technologies for NPP deployment and the validation of the data from these technologies. Advanced diagnostics, monitoring and prognostics applied to passive structures, which in the USA context of longer term operation is up to 80 years, are being researched. Early laboratory work is demonstrating the potential for these methods, although technical challenges remain. It can be expected that there will be an increased need for and use of on-line monitoring for a wide range of both active and passive systems in all types of nuclear power plants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnostics and Prognostics Tools for Assessing Remaining Useful Life of Nuclear Power Plant Materials

In recent years, there has been renewed interest in expanding the use of nuclear power to provide sustainable, carbon-free energy. As part of these activities in the USA, there are major initiatives focused on "life extension" for existing light-water nuclear power reactors (LWR) from 60 to 80 (or 100) years. To enable longer term operation, a range of advanced diagnostics and prognostics methods that are suitable for on-line, continuous, in-plant monitoring over extended time periods (months to years) are necessary. A central issue in life extension for the current fleet of LWRs is the early detection and monitoring of materials degradation. Material aging and degradation due to stresses and irradiation is a critical element in assessing potential for the failure of components in legacy nuclear power plants. A related issue is the ability to estimate remaining useful life (RUL) of components and systems based on condition assessment or degradation information. Detection of early stage damage in materials and assessment of remaining life is important in proactive or prognostic-based life management of legacy nuclear power plants. These approaches go beyond what is currently included in "condition-based maintenance," this strategy can potentially improve safety and reduce costs by detecting damage and scheduling appropriate maintenance/mitigation strategies early in the component lifecycle. For early detection of degradation, novel nondestructive (i.e., without destroying the utility of the specimen) tests that are suitable for continuous monitoring over extended time periods are needed, as are new techniques for data integration. The challenge of predicting remaining life starting from earlier phases of degradation is also largely unsolved and will require new prognostics tools. This paper will discuss the development and application of advanced diagnostics and prognostics tools to the life extension problem. The focus of these activities will be on ferritic and stainless steels, and degradation mechanisms common to an LWR operating environment in these materials. The use of micromagnetic measurements to assess early stages of degradation will be discussed. The measurements will be used, along with models of degradation accumulation over time, to assess the remaining useful life using a Bayesian prognostic algorithm. The primary advantage of a Bayesian approach is the ability to incorporate a priori information to constrain the solution of the problem and mitigate uncertainties in the measurements. Further, a Bayesian approach enables the incorporation of additional information as it becomes available, which can be used to update, and refine, the RUL estimates. Results of the proposed techniques on experimentally acquired measurements will be presented in the full paper.

diagnostics↗

Health Assessment and Performance Monitoring of Large Machine Diagnostics

Diagnostic machines are a crucial component of the Stockpile Stewardship Program for data collection, toward the ultimate goal of improving our understanding of nuclear physics. These systems consist of interactions between many complex components, and require regular maintenance for acceptable performance. The Cygnus X-ray diagnostic located at the Nevada National Security Site's U1a underground facility which provides radiographic data for subcritical experiments, is a prime example of these systems. Component degradation and failures within Cygnus can result in system downtime and data loss, affecting schedules and increasing experiment costs. To evade such failures, years worth of data on machine performance has been collected on the two Cygnus axes in the form of voltage and current measurements of Cygnus' various components. Using these as input, we have developed machine learning techniques for assessing the health of Cygnus, with the ultimate goal of predicting declining performance and machine failure.

97 MATHEMATICS AND COMPUTING↗

Diffraction effects in coherent transition radiation diagnostics for sub-mm bunch length measurement

Electrons crossing the boundary between different media generate bursts of transition radiation. In the case of bunches of N electrons, the radiation is coherent and has an N-squared enhancement at wavelengths related to the longitudinal bunch distribution. This coherent transition radiation has therefore attracted attention as an interceptive charged particle beam diagnostic technique. Many analytical descriptions have been devised describing the spectral distribution generated by electron bunches colliding with thin metallic foils making different simplifying assumptions. For typical bunches having lengths in the sub-millimeter range, measurable spectra are generated up into the millimeter range. Analysis of this THz radiation is performed using optical equipment tens of millimeters in size. This gives rise to concern that optical diffraction effects may spread the wavefront of interest into regions larger than the optical elements and partially escape detection, generating a wavelength-dependent instrument response. In this paper we present a model implementing vector diffraction theory to analyze these effects in bunch length diagnostics based on coherent transition radiation.

43 PARTICLE ACCELERATORS↗

A Review of X-ray Diagnostic Calibrations in the 2 to 100 keV Region Using the High Energy X-ray Calibration Facility (HEX)

The precise and accurate measurement of X-rays in the 2 keV to 100 keV region is crucial to the understanding of HED plasmas and warm dense matter in general. With the emergence of inertially confined plasma facilities as the premier platforms for ICF, laboratory astrophysics, and national security related plasma experiments, the need to calibrate diagnostics in the high energy X-ray regime has grown. At National Security Technologies High Energy X-ray Calibration Facility (HEX) in Livermore, California, X-ray imagers, filter-fluorescer spectrometers, crystal spectrometers, image plates, and nuclear diagnostics are calibrated. The HEX can provide measurements of atomic line radiation, X-ray flux (accuracy within 10%), and X-ray energy (accuracy within 1%). The HEX source is comprised of a commercial 160 kV X-ray tube, a fluorescer wheel, a filter wheel, and a lead encasement. The X-ray tube produces a Tungsten bremsstrahlung spectrum which causes a foil to fluoresce line radiation. To minimize bremsstrahlung in the radiation for calibration we also provide various foils as filters. For experimental purposes, a vacuum box capable of 10{sup -7} Torr, as well as HPGe and CdTe radiation detectors, are provided on an optical table. Most geometries and arrangements can be changed to meet experimental needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗