Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Rapid Responding Palladium-Silver Surface Modified Microsensor for Hydrogen

Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leak detection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid equilibration with the H2 concentration in the surrounding air. The wet chemical process and gas phase conditioning offer a novel approach at creating highly structured surfaces that have not been reported for MC devices. Additionally, these sensors have very low H2 detection thresholds, wide dynamic range and very good selectivity relative to common interferents.

08 HYDROGEN↗

Sensoring hydrogen gas concentration using electrolyte made of proton

Hydrogen gas promises to be a major clean fuel in the near future. Thus, sensors that can measure the concentrations of hydrogen gas over a wide dynamic range (e.g., 1 99.9%) are in demand for the production, storage, and utilization of hydrogen gas. However, it is difficult to directly measure hydrogen gas concentrations greater than 10% using conventional sensor [1 11]. We report a simple sensor using an electrolyte made of proton conductive manganese dioxide that enables in situmeasurements of hydrogen gas concentration over a wide range of 0.1 99.9% at room temperature.

08 HYDROGEN↗

Direct Detection of Soil mRNAs using Targeted Microarrays for Genes Associated with Lignin Degradation

Microarrays have become established tools for describing microbial systems, however the assessment of expression profiles for environmental microbial communities still presents unique challenges. Notably, the concentration of particular transcripts are likely very dilute relative to the pool of total RNA, and PCR-based amplification strategies are vulnerable to amplification biases and the appropriate primer selection. Thus, we apply a signal amplification approach, rather than template amplification, to analyze the expression of genes encoding selected lignin-degrading enzymes in soil. Controls in the form of known amplicons and cDNA from Phanerochaete chrysosporium were included and mixed with the soil cDNA both before and after the signal amplification in order to assess the dynamic range of the microarray. We demonstrate that restored prairie soil expresses a diverse range of genes encoding lignin-degrading enzymes following incubation with lignin substrate, while farmed agricultural soil does not. The mixed additions of control cDNA with soil cDNA does interfere with detection of the low abundance transcripts, nevertheless this microarray approach consistently reports the higher-abundance transcripts which present more robust signals.

09 BIOMASS FUELS↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Atomic resolution convergent beam electron diffraction analysis using convolutional neural networks

Two types of convolutional neural network (CNN) models, a discrete classification network and a continuous regression network, were trained to determine local sample thickness from convergent beam diffraction (CBED) patterns of SrTiO 3 collected in a scanning transmission electron microscope (STEM) at atomic column resolution. Acquisition of atomic resolution CBED patterns for this purpose requires careful balancing of CBED feature size in pixels, acquisition speed, and detector dynamic range. The training datasets were derived from multislice simulations, which must be convolved with incoherent source broadening. Sample thicknesses were also determined using quantitative high-angle annular dark-field (HAADF) STEM images acquired simultaneously. The regression CNN performed well on sample thinner than 35 nm, with 70% of the CNN results within 1 nm of HAADF thickness, and 1.0 nm overall root mean square error between the two measurements. The classification CNN was trained for a thicknesses up to 100 nm and yielded 66% of CNN results within one classification increment of 2 nm of HAADF thickness. Our approach depends on methods from computer vision including transfer learning and image augmentation.

36 MATERIALS SCIENCE↗

IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomic biomarker discovery

Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up to 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.

59 BASIC BIOLOGICAL SCIENCES↗

Implications of inertial subrange scaling for stably stratified mixing

In this work, we investigate the effects of the turbulent dynamic range on active scalar mixing in stably stratified turbulence by adapting the theoretical passive scalar modelling and demonstrating their usefulness through consideration of the results of direct numerical simulations of statistically stationary homogeneous stratified and sheared turbulence. By analysis of inertial and inertial–convective subrange scalings, we show that the relationship between the active scalar and turbulence time scales is predicted by the ratio of the Kolmogorov and Obukhov–Corrsin constants, provided mean flow parameters permit the two subrange scalings to be appropriate approximations. We use the resulting relationship between time scales to parameterise an appropriate turbulent mixing coefficient $\varGamma \equiv \chi /\epsilon$, defined here as the ratio of available potential energy ($E_p$) and turbulent kinetic energy ($E_k$) dissipation rates. With the analysis presented here, we show that $\varGamma$ can be estimated by $E_p,E_k$ and a universal constant provided an appropriate Reynolds number is sufficiently high. This large Reynolds number regime appears here to occur at $ {{Re_b}} \equiv \epsilon / \nu N^{2} \gtrapprox 300$ where $\nu$ is the kinematic viscosity and $N$ is the characteristic buoyancy frequency. We propose a model framework for irreversible diapycnal mixing with robust theoretical parametrisation and asymptotic behaviour in this high-$ {{Re_b}}$ limit.

42 ENGINEERING↗

Prandtl number effects on extreme mixing events in forced stratified turbulence

Relatively strongly stratified turbulent flows tend to self-organise into a ‘layered anisotropic stratified turbulence’ (LAST) regime, characterised by relatively deep and well-mixed density ‘layers’ separated by relatively thin ‘interfaces’ of enhanced density gradient. Understanding the associated mixing dynamics is a central problem in geophysical fluid dynamics. It is challenging to study LAST mixing, as it is associated with Reynolds numbers $Re := UL/\nu \gg 1$ and Froude numbers $Fr :=(2{\rm \pi} U)/(L N) \ll 1$ ( $U$ and $L$ being characteristic velocity and length scales, $\nu$ the kinematic viscosity and $N$ the buoyancy frequency). Since a sufficiently large dynamic range (largely) unaffected by stratification and viscosity is required, it is also necessary for the buoyancy Reynolds number $Re_{b} := \epsilon /(\nu N^{2}) \gg 1$ , where $\epsilon$ is the (appropriately volume-averaged) turbulent kinetic energy dissipation rate. This requirement is exacerbated for oceanically relevant flows, as the Prandtl number $Pr := \nu /\kappa = {O}(10)$ in thermally stratified water (where $\kappa$ is the thermal diffusivity), thus leading (potentially) to even finer density field structures. We report here on four forced fully resolved direct numerical simulations of stratified turbulence at various Froude ( $Fr=0.5, 2$ ) and Prandtl ( $Pr=1, 7$ ) numbers forced so that $Re_{b}=50$ , with resolutions up to $30\,240 \times 30\,240 \times 3780$ . We find that, as $Pr$ increases, emergent ‘interfaces’ become finer and their contribution to bulk mixing characteristics decreases at the expense of the small-scale density structures populating the well-mixed ‘layers’. However, extreme mixing events (as quantified by significantly elevated local destruction rates of buoyancy variance $\chi _0$ ) are always preferentially found in the (statically stable) interfaces, irrespective of the value of $Pr$ .

Mechanics↗

Grains and Strains from Cepstral Analysis of 4D-STEM Nano-Diffraction Datasets

We report the availability of fast, high dynamic range pixel array detectors makes scanning convergent beam electron diffraction (CBED) a powerful tool for rapid, spatially resolved characterization of lattice structure over a wide range of length scales. However, to extract useful structural information from the large 4-dimensional datasets, especially for complex, 3D specimens, we must confront challenges with CBED intensity variations due to crystal mistilts and multiple scattering as well as challenges with precisely localizing diffracted disk centers.

36 MATERIALS SCIENCE↗

In Situ Reactivity and TOF SIMS Analysis of Surfaces Prepared by Soft and Reactive Landing of Mass Selected Ions

An instrument has been designed and constructed that enables in situ reactivity and time of flight secondary ion mass spectrometry (TOF-SIMS) analysis of surfaces prepared or modified through soft- and reactive landing of mass-selected polyatomic cations and anions. The apparatus employs an electrospray ion source coupled to a high transmission electrodynamic ion funnel, two focusing collision quadrupoles, a large 19 mm diameter quadrupole mass filter, and a quadrupole bender that deflects the ion beam, thereby preventing neutral contaminants from impinging on the deposition surface. The ion soft landing apparatus is coupled to a commercial TOF-SIMS instrument permitting the introduction of surfaces into vacuum and SIMS analysis before and after ion deposition without breaking vacuum. To facilitate a comparison of the current TOF-SIMS instrument with the in situ Fourier transform ion cyclotron resonance (FT-ICR-SIMS) deposition apparatus constructed previously, dications of the cyclic peptide Gramicidin S (GS) and the photoactive organonometallic complex ruthenium tris-bipyridine (Ru(bpy)3) were soft landed onto fluorinated self-assembled monolayer (FSAM) on gold surfaces. In both cases similarities and differences were observed in the secondary ion mass spectra, with the TOF-SIMS results, in general, characterized by greater sensitivity, larger dynamic range, less fragmentation, and fewer in-plume reactions than the corresponding FT-ICR-SIMS spectra. The charge reduction kinetics of both the doubly and singly protonated GS cations on the FSAM surface were also examined as was the influence of the primary gallium ion (Ga+) flux on the efficiency of these processes. In addition, we demonstrate that the new instrument enables detailed studies of the reactivity of catalytically active species immobilized by soft- and reactive landing towards gaseous reagents.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescence intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

An Automated Platform for High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry

An automated platform has been developed for acquisition and visualization of mass spectrometry imaging (MSI) data using nanospray desorption electrospray ionization (nano-DESI). The new system enables robust operation of the nano-DESI imaging source over many hours. This is achieved by controlling the distance between the sample and the probe by mounting the sample holder onto an automated XYZ stage and defining the tilt of the sample plane. This approach is useful for imaging of relatively flat samples such as thin tissue sections. Custom software called MSI QuickView was developed for visualization of large data sets generated in imaging experiments. MSI QuickView enables fast visualization of the imaging data during data acquisition and detailed processing after the entire image is acquired. The performance of the system is demonstrated by imaging rat brain tissue sections. High resolution mass analysis combined with MS/MS experiments enabled identification of lipids and metabolites in the tissue section. In addition, high dynamic range and sensitivity of the technique allowed us to generate ion images of low-abundance isobaric lipids. High-spatial resolution image acquired over a small region of the tissue section revealed the spatial distribution of an abundant brain metabolite, creatine, in the white and gray matter that is consistent with the literature data obtained using magnetic resonance spectroscopy.

Environmental Molecular Sciences Laboratory↗

Improving N-Glycan Coverage using HPLC-MS with Electrospray Ionization at Subambient Pressure

Human serum glycan profiling with mass spectrometry (MS) has been employed to study several disease conditions and is demonstrating promise for e.g. clinical biomarker discovery. However, the poor glycan ionization efficiency and the large dynamic range of glycan concentrations in human sera hinder comprehensive profiling. In particular, large glycans are problematic because they are present at low concentrations and prone to fragmentation. Here we show that the sub-ambient pressure ionization with nanoelectrospray (SPIN)-MS can expand the serum glycome profile when compared with the conventional atmospheric pressure electrospray ionization (ESI)-MS with a heated capillary inlet. Notably, the ions generated by the SPIN interface were observed at higher charge states for 50% of the annotated glycans. Out of a total of 130 detected glycans, 34 were only detected with the SPIN-MS, resulting in improved coverage of glycan families as well as of glycans with larger numbers of labile monosaccharides.

Environmental Molecular Sciences Laboratory↗

Ultrasensitive Sample Quantitation via Selected Reaction Monitoring Using CITP/CZE-ESI-Triple Quadrupole MS

We demonstrate the direct coupling of transient capillary isotachophoresis/ capillary zone electrophoresis (CITP/CZE) with a high sensitivity triple quadrupole mass spectrometer operating in selected reaction monitoring (SRM) mode for sample quantitation. The capability of CITP/CZE for in situ sample enrichment and separation has been shown to significantly improve the analytical figures of merit. A linear dynamic range spanning more than 4 orders of magnitude was observed. An average signal-to-noise ratio (S/N) of 49.6 was observed for 50 attomoles of targeted peptide in the presence of a complex and much more abundant bovine serum albumin (BSA) digest products. A correlation of variation (CV) less than 10 % for peak area was measured from triplicate sample analyses at 50 pM peptide concentration, showing good reproducibility of this online CITP/CZE-SRM mass spectrometry (MS) platform, and with limit of quantitation (LOQ) demonstrated to be well below 50 pM.

Environmental Molecular Sciences Laboratory↗

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

Environmental Molecular Sciences Laboratory↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗