Search NASA⌕ Search

SEARCH · Search NASA

Results for “e + e - experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Measurement of the Reaction {sup 2}H(e,e{sup '}) at 180 deg. Close to the Deuteron Breakup Threshold

Inclusive inelastic electron scattering off the deuteron under 180 deg. has been studied at the S-DALINAC close to the breakup threshold at momentum transfers q=0.27 fm{sup -1} and 0.74 fm{sup -1} with good energy resolution sufficient to map in detail the spin flip M1 response, which governs the starting reaction pn{yields}d{gamma} of big-bang nucleosynthesis over most of the relevant temperature region. Results from potential model calculations and (for q=0.27 fm{sup -1}) from pionless nuclear effective field theory are in excellent agreement with the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-E-01: ABR Diagnostic Radiology Core Exam: Was Our Redesigned Physics Course Successful in Teaching Physics to Radiology Residents?

Purpose: Our purpose is to evaluate the effectiveness of our two year physics course in preparing radiology residents for the American Board of Radiology (ABR) diagnostic radiology exam. Methods: We designed a new two-year physics course that integrates radiology clinical content and practice and is primarily based on the AAPM curriculum and RSNA/AAPM physics modules. Biweekly classes focus on relevant concepts from assigned reading and use audience response systems to encourage participation. Teaching efficiency is optimized through lecturer rotations of physicists, radiologists, and guest speakers. An emphasis is placed on clinical relevance by requiring lab work and providing equipment demonstrations. Periodic quiz were given during the course. The course website was also redesigned for usability, and physics review lectures were conducted two weeks before the board exam to refresh key concepts. At the completion of our first two-year course, we conducted a confidential evaluation of the faculty and course. The evaluation assessed metrics such as overall organization, clinical relevance of content, and level of difficulty, with a rating scale from poor to excellent. Results: Our evaluation indicated that the redesigned course provided effective board exam preparation, with most responses between good and excellent. There was some criticism on the course length and on chronological discontinuity, but the review lectures were appreciated by the residents. All of our residents passed the physics component of the ABR exam with scores exceeding the minimum passing score by a significant margin. Conclusion: The course evaluation and board exam results indicate that our new two-year course format provides valuable board exam preparation. This is possible thanks to the time and effort taken by the physics faculty on ensuring the residents get quality physics education.

60 APPLIED LIFE SCIENCES↗

SU-E-E-02: Dashboard for Tracking Physics Resident Progress

Purpose: Design a system to easily and securely track the progress of medical physics residents through their residency. Paper sign-offs while offering a real signature are not easily updated or summarized. A resident or mentor needs to be able to quickly assess what the current assignments are, what are overdue, and whether the resident is on track to complete all the tasks in a timely fashion. An electronic version can accomplish all these goals. Methods: An electronic dashboard was created in excel to not only house the tasks and sign-off but to succinctly summarize the residents progress. The first tab contains the dashboard which displays tables of the progress of the residents in each rotation, their current task, and overdue tasks. It also displays the last meetings with the residents, and timeline of important items, and a burn-down chart of the remaining tasks. This are all tied to the data and current date which auto fills the tables. The second tab contains the data. This is comprised of lists of rotations and their associated tasks along with their due dates. A signature column was also created which is password protected but allows special subset users i.e. mentors to alter without using a password. Results: The dashboard has allowed residents to better track their progress and tells them what they should be working on. It has also allowed the mentors and the program director to rapid assess their progress. Conclusion: The dashboard is successful and has been created to allow easy addition and subtraction of required tasks as the residency evolves. The next step is to create a web app version of the excel sheet with logins.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-E-03: Developing Solutions to Critical Radiation Oncology Challenges in Tanzania

Purpose: Develop solutions to critical medical physics challenges in Tanzania. Methods: In September of 2013 we began working with Jumaa Bin Dachi, a Therapy Physicist at the Ocean Road Cancer Institute in Dar es Salaam, Tanzania. We developed a bi-lateral learning partnership over the course of eight qualitative Skype meetings with Jumaa. From these meetings we have ascertained that there is a gap between the installation of new equipment and treating patients. This gap has often been overlooked by international partners attempting to improve radiation therapy access. Relationships with academic institutions abroad can fill these gaps, and lead to sustained care of patients needing radiation. Results: Our efforts are best given in a supporting role to help develop solutions and new technology that can reduce the burden on the Medical Physicist. Solutions may include: training material, support for radiation therapy classes, development of appropriate local protocols, and peer-review on documents being produced. New technology needs to focus around simple and easy field shaping, improved patient imaging systems, and systems for patient set-up. We believe our work can help alleviate some of the burdens faced by this institute. Conclusion: While we are just in the beginning stage of this partnership, we believe there is great potential for success between both parties. We hope that the Ocean Road Cancer Institute will benefit from potential funding and resources by partnering with a High Income Country to develop affordable solutions to clinical problems in Tanzania.

60 APPLIED LIFE SCIENCES↗

SU-E-E-07: When the Old Ways Are the Best Ways: In Defense of Didactic Training

Purpose: Physics education for residents has taken on a more prominent role due to the new ABR examination format. We present a curriculum for a new radiology residency entering its second year. This curriculum favors an extensive traditional didactic teaching approach. The curriculum is designed to minimize the amount of independent learning that is necessary outside the classroom Methods and Materials: idactic training repeats yearly for all four years of residency and consists of two 1-hour lectures per week and several in-class tests. The impact of physics on clinical practice is introduced gradually throughout the residency using specific clinical cases. The extensive time spent with the residents allows lectures to be taught at a deep (almost physicist) level and reduces the necessity of learning base concepts outside of lecture. This frees the resident to use resources (e.g., AAPM/RSNA physics modules) to cement concepts through repetition or to learn a slightly confusing concept from a different teaching perspective. Consistent testing reduces the traditional resident studying technique of physics “cramming.” Results: On average, the first year residents scored in the 98th percentile on the American College of Radiology Diagnostic Radiology In-Service Training Exam (ACR DXIT). Feedback from the new first year residents was very positive and suggestions are constantly solicited and incorporated. For example, based on resident feedback, short-format quizzes each lecture were eliminated and replaced interactive questions during lecture. Residents felt they have advanced rapidly and have a better understanding of radiologic physics, though they have expressed concern that the 1-hour lecture block may not be optimal for learning physics. Conclusion: An extensive, physicist-led series of didactic lectures is effective in the teaching of physics to residents.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

SU-E-E-02: An Excel-Based Study Tool for ABR-Style Exams

Purpose: As the landscape of learning and testing shifts toward a computer-based environment, a replacement for paper-based methods of studying is desirable. Using Microsoft Excel, a study tool was developed that allows the user to populate multiple-choice questions and then generate an interactive quiz session to answer them. Methods: The code for the tool was written using Microsoft Excel Visual Basic for Applications with the intent that this tool could be implemented by any institution with Excel. The base tool is a template with a setup macro, which builds out the structure based on user’s input. Once the framework is built, the user can input sets of multiple-choice questions, answer choices, and even add figures. The tool can be run in random-question or sequential-question mode for single or multiple courses of study. The interactive session allows the user to select answer choices and immediate feedback is provided. Once the user is finished studying, the tool records the day’s progress by reporting progress statistics useful for trending. Results: Six doctoral students at UTHSCSA have used this tool for the past two months to study for their qualifying exam, which is similar in format and content to the American Board of Radiology (ABR) Therapeutic Part II exam. The students collaborated to create a repository of questions, met weekly to go over these questions, and then used the tool to prepare for their exam. Conclusion: The study tool has provided an effective and efficient way for students to collaborate and be held accountable for exam preparation. The ease of use and familiarity of Excel are important factors for the tool’s use. There are software packages to create similar question banks, but this study tool has no additional cost for those that already have Excel. The study tool will be made openly available.

97 MATHEMATICS AND COMPUTING↗

SU-E-E-03: Shared Space Fosters Didactic and Professional Learning Across Professions for Medical and Physics Residents

Purpose: Medical Physicists and Radiation Oncologists are two professions who should be working as a team for optimal patient care, yet lack of mutual understanding about each others respective role and work environment creates barriers To improve collaboration and learning, we designed a shared didactic and work space for physics and radiation oncology residents to maximize interaction throughout their professional training. Methods: Physician and Physics residents are required to take the same didactic classes, including journal clubs and respective seminars. The residents also share an office environment among the seven physician and two physic residents. Results: By maximizing didactic overlap and sharing office space, the two resident groups have developed a close professional relationship and supportive work environment. Several joint research projects have been initiated by the residents. Awareness of physics tasks in the clinic has led to a request by the physician residents to change physics didactics, converting the physics short course into a lab-oriented course for the medical residents which is in part taught by the physics residents. The physics seminar is given by both residency groups; increased motivation and interest in learning about physics has led to several medical resident-initiated topic selections which generated lively discussion. The physics long course has changed toward including more discussion among residents to delve deeper into topics and study beyond what passing the boards would require. A supportive work environment has developed, embedding the two physics residents into a larger residents group, allowing them to find mentor and peers more easily. Conclusion: By creating a shared work and didactic environment, physician and physics residents have improved their understanding of respective professional practice. Resident-initiated changes in didactic practice have led to improved learning and joint research. A strong social support system has developed, embedding physics residents into a larger peer group.

60 APPLIED LIFE SCIENCES↗

SU-E-E-06: Teaching About the Gamma Camera and Ultrasound Imaging

Purpose: Instructional modules on applications of physics in medicine are being developed. The target audience consists of students who have had an introductory undergraduate physics course. This presentation will concentrate on an active learning approach to teach the principles of the gamma camera. There will also be a description of an apparatus to teach ultrasound imaging. Methods: Since a real gamma camera is not feasible in the undergraduate classroom, we have developed two types of optical apparatus that teach the main principles. To understand the collimator, LEDS mimic gamma emitters in the body, and the photons pass through an array of tubes. The distance, spacing, diameter, and length of the tubes can be varied to understand the effect upon the resolution of the image. To determine the positions of the gamma emitters, a second apparatus uses a movable green laser, fluorescent plastic in lieu of the scintillation crystal, acrylic rods that mimic the PMTs, and a photodetector to measure the intensity. The position of the laser is calculated with a centroid algorithm.To teach the principles of ultrasound imaging, we are using the sound head and pulser box of an educational product, variable gain amplifier, rotation table, digital oscilloscope, Matlab software, and phantoms. Results: Gamma camera curriculum materials have been implemented in the classroom at Loyola in 2014 and 2015. Written work shows good knowledge retention and a more complete understanding of the material. Preliminary ultrasound imaging materials were run in 2015. Conclusion: Active learning methods add another dimension to descriptions in textbooks and are effective in keeping the students engaged during class time. The teaching apparatus for the gamma camera and ultrasound imaging can be expanded to include more cases, and could potentially improve students’ understanding of artifacts and distortions in the images.

60 APPLIED LIFE SCIENCES↗

SU-E-E-07: An Adaptable Approach for Education On Medical Physics at Undergraduate and Postgraduate Levels

Purpose: To contribute to the professional profile of future medical physicists, technologists and physicians, and implement an adaptable educational strategy at both undergraduate and postgraduate levels. Methods: The Medical Physics Block of Electives (MPBE) designed was adapted to the Program of B.S. in Physics. The conferences and practical activities were developed with participatory methods, with interdisciplinary collaboration from research institutions and hospitals engaged on projects of Research, Development and Innovation (RDI). The scientific education was implemented by means of critical analysis of scientific papers and seminars where students debated on solutions for real research problems faced by medical physicists. This approach included courses for graduates not associated to educational programs of Medical Physics (MP). Results: The implementation of the MPBE began in September 2014, with the electives of Radiation MP and Introduction to Nuclear Magnetic Resonance. The students of second year received an Introduction to MP. This initiative was validated by the departmental Methodological Workshop, which promoted the full implementation of the MPBE. Both postgraduated and undergraduate trainees participated in practices with our DICOM viewer system, a local prototype for photoplethysmography and a home-made interface for ROC analysis, built with MATLAB. All these tools were designed and constructed in previous RDI projects. The collaborative supervision of University’s researchers with clinical medical physicists will allow to overcome the limitations of residency in hospitals, to reduce the workload for clinical supervisors and develop appropriate educational activities. Conclusion: We demonstrated the feasibility of adaptable educational strategies, considering available resources. This provides an innovative way for prospective medical physicists, technologists and radiation oncologists. This strategy can be implemented in several regions without formal programs of MP, like most of developing countries. Starting with undergraduate students would allow to reach appropriate certification faster than most of traditional or alternative approaches for education on MP. The authors acknowledge Radiation Consulting Group, LLC, an Arizona Corporation which promotes the use of ionizing radiation in the healing arts, for the “Oscar Luis Caballero” travel grant. The authors thanks to professors Meisbel Daudinot, David Adame and Alexander Pascau for the practices through imagis, imageROC and ANGIODIN PD3000 respectively.

60 APPLIED LIFE SCIENCES↗

SU-E-E-08: Applications of the Quantization of Coupled Circuits in Radiation Physics (design of Klystron, Bremsstrahlung, Synchrotron)

Purpose: During the past decade the quantization of coupled/forced electromagnetic circuits with or without Ohm’s resistance has gained the subject of some fundamental studies, since even problems of quantum electrodynamics can be solved in an elegant manner, e.g. the creation of quantized electromagnetic fields. In this communication, we shall use these principles to describe optimization procedures in the design of klystrons, synchrotron irradiation and high energy bremsstrahlung. Methods: The base is the Hamiltonian of an electromagnetic circuit and the extension to coupled circuits, which allow the study of symmetries and perturbed symmetries in a very apparent way (SU2, SU3, SU4). The introduction resistance and forced oscillators for the emission and absorption in such coupled systems provides characteristic resonance conditions, and atomic orbitals can be described by that. The extension to virtual orbitals leads to creation of bremsstrahlung, if the incident electron (velocity v nearly c) is described by a current, which is associated with its inductivitance and the virtual orbital to the charge distribution (capacitance). Coupled systems with forced oscillators can be used to amplify drastically the resonance frequencies to describe klystrons and synchrotron radiation. Results: The cross-section formula for bremsstrahlung given by the propagator method of Feynman can readily be derived. The design of klystrons and synchrotrons inclusive the radiation outcome can be described and optimized by the determination of the mutual magnetic couplings between the oscillators induced by the currents. Conclusions: The presented methods of quantization of circuits inclusive resistance provide rather a straightforward way to understand complex technical processes such as creation of bremsstrahlung or creation of radiation by klystrons and synchrotrons. They can either be used for optimization procedures and, last but not least, for pedagogical purposes with regard to a qualified understanding of radiation physics for students.

43 PARTICLE ACCELERATORS↗

SU-E-E-11: Novel Matching Module for Respiration-Gated Motion Tumor of Cone-Beam Computed Tomography (CBCT) to 4DCT

Purpose: Four dimensional computed tomography (4DCT) scans reliably record whole respiratory phase and generate internal target volumes (ITV) for radiotherapy planning. However, image guiding with cone-beam computed tomography (CBCT) cannot acquire all or specific respiratory phases. This study was designed to investigate the correlation between average CT and Maximum Intensity Projection (MIP) from 4DCT and CBCT. Methods: Retrospective respiratory gating were performed by GE Discovery CT590 RT. 4DCT and CBCT data from CRIS Dynamic Thorax Phantom with simulated breathing mode were analyzed. The lung tissue equivalent material encompassed 3 cm sphere tissue equivalent material. Simulated breathing cycle period was set as 4 seconds, 5 seconds and 6 seconds for representing variation of patient breathing cycle time, and the sphere material moved toward inferior and superior direction with 1 cm amplitude simulating lung tumor motion during respiration. Results: Under lung window, the volume ratio of CBCT scans to ITVs derived from 10 phases average scans was 1.00 ± 0.02, and 1.03 ± 0.03 for ratio of CBCT scans to MIP scans. Under abdomen window, the ratio of CBCT scans to ITVs derived from 10 phases average scans was 0.39 ± 0.06, and 0.06 ± 0.00 for ratio of CBCT scans to MIP scans. There was a significant difference between lung window Result and abdomen window Result. For reducing image guiding uncertainty, CBCT window was set with width 500 and level-250. The ratio of CBCT scans to ITVs derived from 4 phases average scans with abdomen window was 1.19 ± 0.02, and 1.06 ± 0.01 for ratio of CBCT to MIP scans. Conclusion: CBCT images with suitable window width and level can efficiently reduce image guiding uncertainty for patient with mobile tumor. By our setting, we can match motion tumor to gating tumor location on planning CT more accurately neglecting other motion artifacts during CBCT scans.

60 APPLIED LIFE SCIENCES↗

SU-E-E-12: Validation of the Implementation of Different CT Scanners in Proton Treatment Planning

Purpose: To quantify the impact of the relationship of CT number and Relative Stopping Power (RSP) among different CT-scanners in the evaluation of dose distribution, for different tumor sites and proton therapy modalities like Pencil Beam and Uniform Scanning. Methods: The same tissue characterization phantom was used to analyze the difference in the X-rays energy spectra of 2 CT scanners of the same vendor. One CT is for planning and the other for treatment verification. The Hounsfield unit (HU) variations and associated dosimetric uncertainty were investigated in uniform scanning and pencil beam treatment plans of different sites. At the same time comparisons of the CT calibration curve were done using the same acquisition protocols. The phantom was imaged on a 16 multi-row CT scanner, with energies of 120 and 140 kVp,currents of 263 and 245 mA and slice thickness of 2 and 3mm respectively. The dosimetric uncertainty of the plans was evaluated in a homogeneus phantom comparing DVHs, gamma index criteria 3% 3mm, and range between them. Results: The variation of HU was within the standard deviation of the average for each tissue substitute. The curves fitted with a bilinear interpolation show a maximum deviation in high density materials like cortical bone and solid water, where the HU values deviated more than 0,6% for the 120kVp protocol. For the others curves the deviation was more than 2% for low densities materials. The gamma index uncertainty criteria passed in all the cases. Conclusion: The HU variations for the different scanners were ≤3%. Lower than the 3,5% uncertainties considered in our treatment planning system. The dosimetric analysis shows that the X-ray spectrum has a small effect on the HU-RSP curve, allowing the use of a single tissue characterization curve in our proton treatment planning system for plans verifications.

60 APPLIED LIFE SCIENCES↗