Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

X-rays only when you want them: Optimized pump–probe experiments using pseudo-single-bunch operation

Laser pump–X-ray probe experiments require control over the X-ray pulse pattern and timing. Here, the first use of pseudo-single-bunch mode at the Advanced Light Source in picosecond time-resolved X-ray absorption experiments on solutions and solids is reported. In this mode the X-ray repetition rate is fully adjustable from single shot to 500 kHz, allowing it to be matched to typical laser excitation pulse rates. Suppressing undesired X-ray pulses considerably reduces detector noise and improves signal to noise in time-resolved experiments. In addition, dose-induced sample damage is considerably reduced, easing experimental setup and allowing the investigation of less robust samples. Single-shot X-ray exposures of a streak camera detector using a conventional non-gated charge-coupled device (CCD) camera are also demonstrated.

43 PARTICLE ACCELERATORS↗

Use of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion

An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering

A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.

36 MATERIALS SCIENCE↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new method for in situ structural investigations of nano-sized amorphous and crystalline materials using mixed-flow reactors

Structural investigations of amorphous and nanocrystalline phases forming in solution are historically challenging. Few methods are capable of in situ atomic structural analysis and rigorous control of the system. A mixed-flow reactor (MFR) is used for total X-ray scattering experiments to examine the short- and long-range structure of phases in situ with pair distribution function (PDF) analysis. The adaptable experimental setup enables data collection for a range of different system chemistries, initial supersaturations and residence times. The age of the sample during analysis is controlled by adjusting the flow rate. Faster rates allow for younger samples to be examined, but if flow is too fast not enough data are acquired to average out excess signal noise. Slower flow rates form older samples, but at very slow speeds particles settle and block flow, clogging the system. Proper background collection and subtraction is critical for data optimization. Overall, this MFR method is an ideal scheme for analyzing the in situ structures of phases that form during crystal growth in solution. As a proof of concept, high-resolution total X-ray scattering data of amorphous and crystalline calcium phosphates and amorphous calcium carbonate were collected for PDF analysis.

36 MATERIALS SCIENCE↗

A Generic Communication Protocol for Remote Laboratories: an Implementation on e-lab

The remote laboratories at IST (Instituto Superior Tecnico), e-lab, serve as a valuable tool for education and training based on remote control technologies. Due to the high number and increase of remotely operated experiments a generic protocol was developed to perform the communication between the software driver and the respective experimental setup in an easier and more unified way. The training in these fields of students and personnel can take advantage of such infrastructure with the purpose of deploying new experiments in a faster way. More than 10 experiments using the generic protocol are available on-line in a 24 x 7 way. (authors)

99 GENERAL AND MISCELLANEOUS↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

The dependence of a plasma acceleration process on a expansion area geometry

It has been reported that plasma acceleration by a electron beam results in a ion energy spectra that coincides with energy ion spectra of a pulsed vacuum discharges. Thus, one can assume that acceleration of plasma by electron beam is the basic plasma acceleration mechanism in a different type of a vacuum discharges. This work is devoted to examination of influence of expansion area geometry on an acceleration process. Experimental setup consist of three different units : vacuum diode; plasma cloud formation unit; expansion unit. Experiments were made for three expansion area configuration : Without expansion unit; Expansion tube; Expansion cone. Experiments have shown that narrowing of an expansion area results in additional acceleration of ions. Measurements of an ion energy spectra revealed a high energy tails appearance. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Double-Output CLL Resonant Converter for All-Electric UAV Applications

This paper presents a double-output resonant converter with high-frequency isolation for unmanned aerial vehicle (UAV) applications. The proposed topology is developed by using a full-bridge resonant inverter and double-output half-bridge active rectifiers. For the control system, a phase-shifted pulse width modulation (PS-PWM) method is utilized to adjusts the power flow among the output rectifiers in a wide voltage range regulation with a central control. The theoretical analysis of the converter is explored using the system model under different load conditions with constant frequency. The proposed system is validated with experimental results using 60 V input source and generating 0 - 100 V in each output at a full power of 500 W with 96% maximum efficiency in the laboratory experimental setup.

Asa, Erdem↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1k VA experimental setup that interfaces a PV module to the grid.

generalized PV controller↗

Detection of Cyber Attacks in Grid-tied PV Systems Using Dynamic Watermarking

This paper presents of an active detection scheme for detecting cyber attacks on sensors controlling a grid-tied PV systems. Several cyber vulnerabilities in Grid tied PV Systems are discussed. The defense mechanism introduces a private (secret) watermarking signal into the control inputs of the grid-tied inverter system. This will enable the detection of any malicious manipulation of sensor measurements. Based on the measured data, two statistical tests are conducted to identify anomalies in the system using the presence of the watermarking signal. It shown that when a sensor data is compromised and/or replaced by a pre-recorded healthy signal, both test 1 and 2 exhibit high values indicating a possible malicious activity. The robustness of the proposed algorithm is tested and validated with several attack scenarios on a grid tied PV system. Select results from an experimental setup are discussed.

Ibrahim, Hasan↗

A High-Fidelity Cyber-Physical Testbed-Based Benchmarking Dataset For Testing Operational Technology Specific Intrusion Detection Systems

Quality datasets serve a critical purpose in cyber security research. Data is needed to understand system behavior and develop security controls to protect critical systems. However, for critical infrastructure operational environments there is a lack of available datasets to study because of the high cost and specialized capabilities necessary to generate them. This paper documents the development of a dataset of high fidelity hardware in the loop laboratory simulated models of electric and natural gas distribution systems with real cyber attack test cases. A deep dive discussion for the experimental setup and controls for generating the data is provided along with observations from using the data in evaluating intrusion detection approaches.

Ashok, Aditya↗

Characterization and Comparison of Trench and Planar Silicon Carbide (SiC) MOSFET at Different Temperatures

In this paper, the static and dynamic characteristics of discrete 650 V and 1200 V trench TO 247 SiC MOSFET is evaluated and compared with a similar current rating 1200 V planar gate discrete TO 247 SiC MOSFET. The new trench MOSFET has promising application for vehicle charging and auxiliary power supply application due to the lower on-state resistance and lower capacitance. Static characteristics for these devices are evaluated using a curve tracer for different device junction temperature A common double pulse test (DPT) platform is developed to evaluate the switching loss at different device junction temperature ranging from 25°C to 175°C. The experimental setup and results are presented for different load currents and temperature.

Anwar, Saeed↗

Development of a compact neutron source based on field ionization processes

The authors report on the use of carbon nanofiber nanoemitters to ionize deuterium atoms for the generation of neutrons in a deuterium-deuterium reaction in a preloaded target. Acceleration voltages in the range of 50-80 kV are used. Field emission of electrons is investigated to characterize the emitters. The experimental setup and sample preparation are described and first data of neutron production are presented. Ongoing experiments to increase neutron production yields by optimizing the field emitter geometry and surface conditions are discussed.

43 PARTICLE ACCELERATORS↗

2-ps Hard X-Ray Streak Camera Measurements at Sector 7 Beamline of the Advanced Photon Source

A hard X-ray streak camera capable of 2-ps time resolution is in operation at the Sector 7 beamline of the Advanced Photon Source. It is used for laser-pump, X-ray probe experiments using the Ti:Sapphire femtosecond laser system installed on the beamline. This streak camera, combined with standardized and prealigned experimental setups, can perform time-resolved liquid-phase absorption spectroscopy, reflectivity, and diffraction experiments.

43 PARTICLE ACCELERATORS↗

ECP SOLLVE: Validation and Verification Testsuite Status Update and Compiler Insight for OpenMP

The OpenMP language continues to evolve with every new specification release, as does the need to validate and verify the new features that have been implemented by the different vendors. With the release of OpenMP 5.0 and OpenMP 5.1, new target offload and host-based features have been introduced to the programming model. While OpenMP continues to grow in maturity, there is an observable growth in the number of compiler and hardware vendors that support OpenMP. In this manuscript, the main focus is on evaluating the conformity and OpenMP implementation progress of various compiler vendors such as Cray, IBM, GNU, Clang/LLVM, NVIDIA, and Intel. More specifically, the 4.5, 5.0, and 5.1 versions of the OpenMP specification are analyzed. For our experimental setup, the Crusher and Summit computing systems hosted by Oak Ridge National Lab’s Computing Facilities are utilized. The effort of vendor agnostic analysis of these implementations is especially valuable for application developers who are using new OpenMP features to accelerate their scientific codes. Insights are presented into the current implementation status of various vendors, the progression of specific compiler’s support for OpenMP overtime, the subset of OpenMP 4.5, 5.0, and 5.1 that is supported by all compilers, and examples of how our test suite has influenced discussion regarding the correct interpretation of the OpenMP specification. By evaluating OpenMP conformity of pre-Exascale computing systems, the aim is to detail progress and status of AMD + Cray ecosystem before the system and their OpenMP implementation is used for mission critical applications when the first Exascale Computer Frontier is made available to applications.

Huber, Thomas↗

FALCON readout channel for X-ray ptychography applications

This work reports the current state of the development of a pixelated readout for nanometer resolution X-ray ptychography applications. A very dense, low-noise and low-power pixel developed in a commercial 65nm CMOS technology is envisioned for such applications, targeting a pixel area of 150 μm × 150 μm, an overall noise of 200e- rms and a power consumption of 150μW per pixel. In the paper, an introduction to the application and an overview of the experimental setup are given, the designed frontend channel is reported and revised in its components and simulation results of the schematic-level design are shown and discussed.

Lazzaroni, Paolo↗

Development of a Host-Based Intrusion Detection and Control Device for Industrial Field Control Devices

Industrial control systems contain a multitude of devices deployed into the field to observe and control a physical process. Currently, most of these devices lack common host-based cybersecurity features, which can lead them to be seen as vulnerable targets. The Cymbiote device was developed to address this problem by examining multiple streams of data to determine what might indicate a potential threat, and to evaluate and execute appropriate response actions. This paper discusses the evolution of the Cymbiote device in response to evaluation and testing done on real-world hardware. Experimental results are discussed, as are the new developments that have been made to the device in response to the findings. In addition, we describe future research directions for this approach along with the experimental setup changes in response to the requirements for statistical rigor.

Rice, Theora R.↗