Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Spatially recursive filtering and smoothing for multibody dynamics

Methods developed recently by the author to solve the problem of forward dynamics for nonlinear joint-connected multibody systems are summarized. Solution of this problem is of interest in such application areas as robotics, deploying structures, ground vehicles, and pointing of antennas and instrumented platforms. The problem is solved by the recursive filtering and smoothing techniques of state estimation theory. The filtering stage takes the applied joint moments as inputs to produce a sequence of spatial constraint forces acting at the joints of the system. The smoothing stage takes the innovations process resulting from the filter as an input and produces a set of spatial accelerations and a corresponding set of joint-angle accelerations.

Rodriguez, G.↗

Experimental validation of a three-dimensional linear system model for breast tomosynthesis

A three-dimensional (3D) linear model for digital breast tomosynthesis (DBT) was developed to investigate the effects of different imaging system parameters on the reconstructed image quality. In the present work, experimental validation of the model was performed on a prototype DBT system equipped with an amorphous selenium (a-Se) digital mammography detector and filtered backprojection (FBP) reconstruction methods. The detector can be operated in either full resolution with 85 {mu}m pixel size or 2x1 pixel binning mode to reduce acquisition time. Twenty-five projection images were acquired with a nominal angular range of {+-}20 deg. The images were reconstructed using a slice thickness of 1 mm with 0.085x0.085 mm in-plane pixel dimension. The imaging performance was characterized by spatial frequency-dependent parameters including a 3D noise power spectrum (NPS) and in-plane modulation transfer function (MTF). Scatter-free uniform x-ray images were acquired at four different exposure levels for noise analysis. An aluminum (Al) edge phantom with 0.2 mm thickness was imaged to measure the in-plane presampling MTF. The measured in-plane MTF and 3D NPS were both in good agreement with the model. The dependence of DBT image quality on reconstruction filters was investigated. It was found that the slice thickness (ST) filter, a Hanning window to limit the high-frequency components in the slice thickness direction, reduces noise aliasing and improves 3D DQE. An ACR phantom was imaged to investigate the effects of angular range and detector operational modes on reconstructed image quality. It was found that increasing the angular range improves the MTF at low frequencies, resulting in better detection of large-area, low-contrast mass lesions in the phantom. There is a trade-off between noise and resolution for pixel binning and full resolution modes, and the choice of detector mode will depend on radiation dose and the targeted lesion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for standard model Higgs boson production in association with a W boson at CDF

We present a search for standard model Higgs boson production in association with a W boson in proton-antiproton collisions (pp{yields}W{sup {+-}}H{yields}l{nu}bb) at a center of mass energy of 1.96 TeV. The search employs data collected with the CDF II detector which correspond to an integrated luminosity of approximately 1 fb{sup -1}. We select events consistent with a signature of a single lepton (e{sup {+-}}/{mu}{sup {+-}}), missing transverse energy, and two jets. Jets corresponding to bottom quarks are identified with a secondary vertex tagging method and a neural network filter technique. The observed number of events and the dijet mass distributions are consistent with the standard model background expectations, and we set 95% confidence level upper limits on the production cross section times branching ratio ranging from 3.9 to 1.3 pb for Higgs boson masses from 110 to 150 GeV/c{sup 2}, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying and reducing model-form uncertainties in Reynolds-averaged Navier–Stokes simulations: A data-driven, physics-informed Bayesian approach

Despite their well-known limitations, Reynolds-Averaged Navier–Stokes (RANS) models are still the workhorse tools for turbulent flow simulations in today's engineering analysis, design and optimization. While the predictive capability of RANS models depends on many factors, for many practical flows the turbulence models are by far the largest source of uncertainty. As RANS models are used in the design and safety evaluation of many mission-critical systems such as airplanes and nuclear power plants, quantifying their model-form uncertainties has significant implications in enabling risk-informed decision-making. In this work we develop a data-driven, physics-informed Bayesian framework for quantifying model-form uncertainties in RANS simulations. Uncertainties are introduced directly to the Reynolds stresses and are represented with compact parameterization accounting for empirical prior knowledge and physical constraints (e.g., realizability, smoothness, and symmetry). An iterative ensemble Kalman method is used to assimilate the prior knowledge and observation data in a Bayesian framework, and to propagate them to posterior distributions of velocities and other Quantities of Interest (QoIs). We use two representative cases, the flow over periodic hills and the flow in a square duct, to evaluate the performance of the proposed framework. Both cases are challenging for standard RANS turbulence models. Simulation results suggest that, even with very sparse observations, the obtained posterior mean velocities and other QoIs have significantly better agreement with the benchmark data compared to the baseline results. At most locations the posterior distribution adequately captures the true model error within the developed model form uncertainty bounds. The framework is a major improvement over existing black-box, physics-neutral methods for model-form uncertainty quantification, where prior knowledge and details of the models are not exploited. This approach has potential implications in many fields in which the governing equations are well understood but the model uncertainty comes from unresolved physical processes. - Highlights: • Proposed a physics–informed framework to quantify uncertainty in RANS simulations. • Framework incorporates physical prior knowledge and observation data. • Based on a rigorous Bayesian framework yet fully utilizes physical model. • Applicable for many complex physical systems beyond turbulent flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Exhaust Stack. The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow -angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Exhaust Stack. The 3430 stack was tested in both January and May of 2010 to document the results of several changes that were made to the exhaust system after the January tests. The 3430 stack meets the qualification criteria given in the American National Standards Institute/Health Physics Society N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliancewith the requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Pathway Stack . The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Pathway stack. Therefore, this new system also meets the qualification criteria given in the ANSI/HPS N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliance to the requirements.

54 ENVIRONMENTAL SCIENCES↗

MO-DE-210-05: Improved Accuracy of Liver Feature Motion Estimation in B-Mode Ultrasound for Image-Guided Radiation Therapy

Purpose: In similarity-measure based motion estimation incremental tracking (or template update) is challenging due to quantization, bias and accumulation of tracking errors. A method is presented which aims to improve the accuracy of incrementally tracked liver feature motion in long ultrasound sequences. Methods: Liver ultrasound data from five healthy volunteers under free breathing were used (15 to 17 Hz imaging rate, 2.9 to 5.5 minutes in length). A normalised cross-correlation template matching algorithm was implemented to estimate tissue motion. Blood vessel motion was manually annotated for comparison with three tracking code implementations: (i) naive incremental tracking (IT), (ii) IT plus a similarity threshold (ST) template-update method and (iii) ST coupled with a prediction-based state observer, known as the alpha-beta filter (ABST). Results: The ABST method produced substantial improvements in vessel tracking accuracy for two-dimensional vessel motion ranging from 7.9 mm to 40.4 mm (with mean respiratory period: 4.0 ± 1.1 s). The mean and 95% tracking errors were 1.6 mm and 1.4 mm, respectively (compared to 6.2 mm and 9.1 mm, respectively for naive incremental tracking). Conclusions: High confidence in the output motion estimation data is required for ultrasound-based motion estimation for radiation therapy beam tracking and gating. The method presented has potential for monitoring liver vessel translational motion in high frame rate B-mode data with the required accuracy. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

Nonlinear Ensemble Filtering with Diffusion Models: Application to the Surface Quasigeostrophic Dynamics

The intersection between classical data assimilation methods and novel machine learning techniques has attracted significant interest in recent years. Here, we explore another promising solution in which diffusion models are used to formulate a robust nonlinear ensemble filter for sequential data assimilation. Unlike standard machine learning methods, the proposed ensemble score filter (EnSF) is completely training free and can efficiently generate a set of analysis ensemble members. Here, in this study, we apply the EnSF to a surface quasigeostrophic model and compare its performance against the popular local ensemble transform Kalman filter (LETKF), which makes Gaussian assumptions in the analysis step. Numerical tests demonstrate that EnSF maintains stable performance in the absence of localization and for a variety of experimental settings. We find that while LETKF maintains optimal performance in the case of linear observations of the entire state and a perfect model, EnSF shows improvements over LETKF when nonlinear observations are assimilated and the system is subject to unexpected model errors. A spectral decomposition of the analysis results in this nonlinear observation regime shows that the largest improvements over LETKF occur at large scales (small wavenumbers), where LETKF lacks sufficient ensemble spread. Overall, this initial application of EnSF to a geophysical model of intermediate complexity motivates further development of the algorithm for more realistic problems.

Artificial intelligence↗

Transition of Iodine Analysis to Accelerator Mass Spectrometry

Funding was received from NA-22 to investigate transitioning iodine isotopic analyses to an accelerator mass spectrometry (AMS) system. The present method uses gas-phase chemistry followed by thermal ionization mass spectrometry (TIMS). It was anticipated that the AMS approach could provide comparable data, with improved background levels and superior sample throughput. An aqueous extraction method was developed for removal of iodine species from high-volume air filters. Ethanol and sodium hydroxide, plus heating and ultrasonic treatment, were used to successfully extract iodine from loaded high-volume air filters. Portions of the same filters were also processed in the traditional method and analyzed by TIMS for comparison. Aliquot parts of the aqueous extracts were analyzed by AMS at the Swiss Federal Institute of Technology. Idaho National Laboratory (INL) personnel visited several AMS laboratories in the US, Spain, and Switzerland. Experience with AMS systems from several manufacturers was gained, and relationships were developed with key personnel at the laboratories. Three batches of samples were analyzed in Switzerland, and one in Spain. Results show that the INL extraction method successfully extracted enough iodine from high-volume air filters to allow AMS analysis. Comparison of the AMS and TIMS data is very encouraging; while the TIMS showed about forty percent more atoms of 129I, the 129/127 ratios tracked each other very well between the two methods. The time required for analysis is greatly reduced for the aqueous extraction/AMS approach. For a hypothetical batch of thirty samples, the AMS methodology is about five times faster than the traditional gas-phase chemistry and TIMS analysis. As an additional benefit, background levels for the AMS method are about 1000 times lower than for TIMS. This results from the fundamental mechanisms of ionization in the AMS system and cleanup of molecular interferences. We showed that an aqueous extraction of high-volume air filters, followed by isotopic analysis by AMS, can be used successfully to make iodine measurements with results comparable to those obtained by filter combustion and TIMS analysis.

47 OTHER INSTRUMENTATION↗

ATTITUDE FILTERING ON SO(3)

A new method is presented for the simultaneous estimation of the attitude of a spacecraft and an N-vector of bias parameters. This method uses a probability distribution function defined on the Cartesian product of SO(3), the group of rotation matrices, and the Euclidean space W N .The Fokker-Planck equation propagates the probability distribution function between measurements, and Bayes s formula incorporates measurement update information. This approach avoids all the issues of singular attitude representations or singular covariance matrices encountered in extended Kalman filters. In addition, the filter has a consistent initialization for a completely unknown initial attitude, owing to the fact that SO(3) is a compact space.

Markley, F. Landis↗

TH-C-17A-08: Monte Carlo Based Design of Efficient Scintillating Fiber Dosimeters

Purpose: To accurately predict Cherenkov radiation generation in scintillating fiber dosimeters. Quantifying Cherenkov radiation provides a method for optimizing fiber dimensions, orientation, optical filters, and photodiode spectral sensitivity to achieve efficient real time imaging dosimeter designs. Methods: We develop in-house Monte Carlo simulation software to model polymer scintillation fibers' fluorescence and Cherenkov emission in megavoltage clinical beams. The model computes emissions using generation probabilities, wavelength sampling, fiber photon capture, and fiber transport efficiency and incorporates the fiber's index of refraction, optical attenuation in the Cherenkov and visible spectrum and fiber dimensions. Detector component selection based on parameters such as silicon photomultiplier efficiency and optical coupling filters separates Cherenkov radiation from the dose-proportional scintillating emissions. The computation uses spectral and geometrical separation of Cherenkov radiation, however other filtering techniques can expand the model. Results: We compute Cherenkov generation per electron and fiber capture and transmission of those photons toward the detector with incident electron beam angle dependence. The model accounts for beam obliquity and nonperpendicular electron fiber impingement, which increases Cherenkov emission and trapping. The rotational angle around square fibers shows trapping efficiency variation from the normally incident minimum to a maximum at 45 degrees rotation. For rotation in the plane formed by the fiber axis and its surface normal, trapping efficiency increases with angle from the normal. The Cherenkov spectrum follows the theoretical curve from 300nm to 800nm, the wavelength range of interest defined by silicon photomultiplier and photodiode spectral efficiency. Conclusion: We are able to compute Cherenkov generation in realistic real time scintillating fiber dosimeter geometries. Design parameters incorporate fiber dimensions, orientations, several types of detector spectral response, optical coupling filters and light transport. We can vary these parameters to design and optimize high efficiency real time dosimeters capable of enhancing external beam patient safety and treatment accuracy. This research was supported in part by a GAANN Fellowship from the Department of Education.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A decentralized square root information filter/smoother

A number of developments has recently led to a considerable interest in the decentralization of linear least squares estimators. The developments are partly related to the impending emergence of VLSI technology, the realization of parallel processing, and the need for algorithmic ways to speed the solution of dynamically decoupled, high dimensional estimation problems. A new method is presented for combining Square Root Information Filters (SRIF) estimates obtained from independent data sets. The new method involves an orthogonal transformation, and an information matrix filter 'homework' problem discussed by Schweppe (1973) is generalized. The employed SRIF orthogonal transformation methodology has been described by Bierman (1977).

Bierman, G. J.↗

Dosimetric Impact of Intrafraction Motion During RapidArc Stereotactic Vertebral Radiation Therapy Using Flattened and Flattening Filter-Free Beams

Purpose: To study the dosimetric impact of relatively short-duration intrafraction shifts during a single fraction of RapidArc delivery for vertebral stereotactic body radiation therapy (SBRT) using flattened (FF) and flattening filter-free (FFF) beams. Methods and Materials: The RapidArc plans, each with 2 to 3 arcs, were generated for 9 patients using 6-MV FF and 10-MV FFF beams with maximum dose rates of 1000 and 2400 MU/min, respectively. A total of 1272 plans were created to estimate the dosimetric consequences in target and spinal cord volumes caused by intrafraction shifts during one of the arcs. Shifts of 1, 2, and 3 mm for periods of 5, 10, and 30 seconds, and 5 mm for 5 and 10 seconds, were modelled during a part of the arc associated with high doses and steep dose gradients. Results: For FFF plans, shifts of 2 mm over 10 seconds and 30 seconds could increase spinal cord D{sub max} by up to 6.5% and 13%, respectively. Dosimetric deviations in FFF plans were approximately 2-fold greater than in FF plans. Reduction in target coverage was <1% for 83% and 96% of the FFF and FF plans, respectively. Conclusion: Even short-duration intrafraction shifts can cause significant dosimetric deviations during vertebral SBRT delivery, especially when using very high dose rate FFF beams and when the shift occurs in that part of the arc delivering high doses and steep gradients. The impact is greatest on the spinal cord and its planning-at-risk volume. Accurate and stable patient positioning is therefore required for vertebral SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Bubble-Point Test

Improved bubble-point test devised for large pleated filter elements. Sizes of pores in filters determined more accurately. Test method replaces older test accurate for pore sizes of 20 microns or less, but subject to gross inaccuracy for filter elements with pores of 70 microns or larger. Unlike older test, no measurement of pressure is necessary. Also no need to estimate average depth of filter-element pleats below surface of liquid.

Welch, Peter J.↗

TH-C-19A-03: Characterization of the Dose Per Pulse Dependence of Various Detectors Used in Quality Assurance of FFF Treatment Plans

Purpose: To present the dose per pulse dependence of various QA devices under Flattening Filter Free (FFF) conditions. Methods: Air and liquid filled ion chamber arrays, diode arrays, radiochromic film and optically stimulated luminescence detectors were investigated. All detectors were irradiated under similar conditions of varying dose per pulse on a TrueBeam linac. Dose per pulse was controlled by varying SSD from 70 to 160 cm providing a range from ~0.5 to ~3 mGy per pulse. MU rates of up to 2400 MU/min for 10X FFF and 1400 MU/min for the 6X FFF beam were used. Beam pulses were counted using the Profiler™ diode array and pulse timing was confirmed by examining linac node files. Delivered doses were calculated with the Eclipse™ treatment planning system. Results: The detectors show a range of behaviors depending on the detector type, as expected. Diode arrays show up to 4% change in sensitivity (sensitivity increases with increasing dose per pulse) over the range tested. Air and liquid ion chambers arrays show a change in sensitivity of up to 3% (air) and 6% (liquid) (sensitivity decreases with increasing dose per pulse) while film and OSLD do not demonstrate a dependence on dose per pulse. Conclusion: Dependence of detector response on dose per pulse varies considerably depending on detector design. Interplay between dose per pulse and MU rate also exists for some detectors. Due diligence is required to characterize detector response prior to implementation of a QA protocol for FFF treatment delivery. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. We intend to further investigate the implications of this for VMAT FFF patient specific quality assurance. T Karan and F Viel have received partial funding through the Varian Research program.

60 APPLIED LIFE SCIENCES↗

Cast Film Production with Polyethylene Recycled from a Post-Industrial Printed Multilayer Film by Solvent-Targeted Recovery and Precipitation

The solvent-targeted recovery and precipitation (STRAP) process separates and recovers the constituent resins in multilayer plastic packaging films by selective polymer dissolution. In this work, three different experimental methods were considered to recover a polyethylene (PE) resin from a printed multilayer film by STRAP. The methods consisted of (1) a filter bag system, (2) a Soxhlet extraction, and (3) a jacketed dissolution vessel. Cast films were produced with the PE recovered from each method and were analyzed for color, mechanical properties, and number of impurities. High-quality recycled PE cast films can be produced by increasing the solvent to plastic ratio, including a filter pore size of 100 μm, and optimizing temperature control in STRAP. Furthermore, this study demonstrates that STRAP polymers can be recycled back into plastic films, enabling the potential circularity of these packaging materials.

36 MATERIALS SCIENCE↗

Early season prediction of within-field crop yield variability by assimilating CubeSat data into a crop model

Accurate early season predictions of crop yield at the within-field scale can be used to address a range of crop production, management, and precision agricultural challenges. While the remote sensing of within-field insights has been a research goal for many years, it is only recently that observations with the required spatio-temporal resolutions, together with efficient assimilation methods to integrate these into modeling frameworks, have become available to advance yield prediction efforts. Here we explore a yield prediction approach that combines daily high-resolution CubeSat imagery with the APSIM crop model. The approach employs APSIM to train a linear regression that relates simulated yield to simulated leaf area index (LAI). That relationship is then used to identify the optimal regression date at which the LAI provides the best prediction of yield: in this case, approximately 14 weeks prior to harvest. Instead of applying the regression on satellite imagery that is coincident, or closest to, the regression date, our method implements a particle filter that integrates CubeSat-based LAI into APSIM to provide end-of-season high-resolution (3 m) yield maps weeks before the optimal regression date. The approach is demonstrated on a rainfed maize field located in Nebraska, USA, where suitable collections of both imagery and in-situ data were available for assessment. The procedure does not require in-field data to calibrate the regression model, with results showing that even with a single assimilation step, it is possible to provide yield estimates with good accuracy up to 21 days before the optimal regression date. Yield spatial variability was reproduced reasonably well, with a strong correlation to independently collected measurements (R 2 = 0.73 and rRMSE = 12%). When the field averaged yield was compared, our approach reduced yield prediction error from 1 Mg/ha (control case based on a calibrated APSIM model), to 0.5 Mg/ha (using satellite imagery alone), and then to 0.2 Mg/ha (results with assimilation up to three weeks prior to the optimal regression date). Such a capacity to provide spatially explicit yield predictions early in the season has considerable potential to enhance digital agricultural goals and improve end-of-season yield predictions.

54 ENVIRONMENTAL SCIENCES↗