At least 865 records · Page 48

Unlocking the potential of DNA-based tagging: current market solutions and expanding horizons

The commercialization of DNA tagging is a growing trend that demonstrates the increasing practicality of this novel approach. This interdisciplinary technology is based on the distinctive characteristics of DNA as a molecule that can remain stable in varying environmental conditions and store data following appropriate preparation. Moreover, newly developed technologies could simplify DNA synthesis and the encoding of data within DNA. The implementation of DNA tagging presents distinctive benefits in comparison to conventional labelling techniques, including universal product code (UPC) barcoding, radio-frequency identification (RFID), quick response (QR) codes, and Bluetooth technologies, by surmounting the limitations encountered by these systems. The discourse pertains to extant DNA-tagging mechanisms along with prospective implementations in a wide range of domains, including but not limited to art, the metaverse, forensics, wildlife monitoring, and the military. The potential of DNA labelling in various contexts underscores the importance of continued research and development in this rapidly evolving field.

59 BASIC BIOLOGICAL SCIENCES↗

Reproduction of melting behavior for vitrified hillforts based on amphibolite, granite, and basalt lithologies

Abstract European Bronze and Iron Age vitrified hillforts have been known since the 1700s, but archaeological interpretations regarding their function and use are still debated. We carried out a series of experiments to constrain conditions that led to the vitrification of the inner wall rocks in the hillfort at Broborg, Sweden. Potential source rocks were collected locally and heat treated in the laboratory, varying maximum temperature, cooling rate, and starting particle size. Crystalline and amorphous phases were quantified using X-ray diffraction both in situ, during heating and cooling, and ex situ, after heating and quenching. Textures, phases, and glass compositions obtained were compared with those for rock samples from the vitrified part of the wall, as well as with equilibrium crystallization calculations. ‘Dark glass’ and its associated minerals formed from amphibolite or dolerite rocks melted at 1000–1200 °C under reducing atmosphere then slow cooled. ‘Clear glass’ formed from non-equilibrium partial melting of feldspar in granitoid rocks. This study aids archaeological forensic investigation of vitrified hillforts and interpretation of source rock material by mapping mineralogical changes and glass production under various heating conditions.

42 ENGINEERING↗

Evaluation of polyanionic cyclodextrins as high affinity binding scaffolds for fentanyl

Abstract Cyclodextrins (CDs) have been previously shown to display modest equilibrium binding affinities ( K a ~ 100–200 M -1 ) for the synthetic opioid analgesic fentanyl. In this work, we describe the synthesis of new CDs possessing extended thioalkylcarboxyl or thioalkylhydroxyl moieties and assess their binding affinity towards fentanyl hydrochloride. The optimal CD studied displays a remarkable affinity for the opioid of K a = 66,500 M −1 , the largest value reported for such an inclusion complex to date. One dimensional 1 H Nuclear Magnetic Resonance (NMR) as well as Rotational Frame Overhauser Spectroscopy (2D-ROESY) experiments supported by molecular dynamics (MD) simulations suggest an unexpected binding behavior, with fentanyl able to bind the CD interior in one of two distinct orientations. Binding energies derived from the MD simulations work correlate strongly with NMR-derived affinities highlighting its utility as a predictive tool for CD candidate optimization. The performance of these host molecules portends their utility as platforms for medical countermeasures for opioid exposure, as biosensors, and in other forensic science applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proof of principle study: synchrotron X-ray fluorescence microscopy for identification of previously radioactive microparticles and elemental mapping of FFPE tissues

Biobanks containing formalin-fixed, paraffin-embedded (FFPE) tissues from animals and human atomic-bomb survivors exposed to radioactive particulates remain a vital resource for understanding the molecular effects of radiation exposure. These samples are often decades old and prepared using harsh fixation processes which limit sample imaging options. Optical imaging of hematoxylin and eosin (H&E) stained tissues may be the only feasible processing option, however, H&E images provide no information about radioactive microparticles or radioactive history. Synchrotron X-ray fluorescence microscopy (XFM) is a robust, non-destructive, semi-quantitative technique for elemental mapping and identifying candidate chemical element biomarkers in FFPE tissues. Still, XFM has never been used to uncover distribution of formerly radioactive micro-particulates in FFPE canine specimens collected more than 30 years ago. In this work, we demonstrate the first use of low-, medium-, and high-resolution XFM to generate 2D elemental maps of ~ 35-year-old, canine FFPE lung and lymph node specimens stored in the Northwestern University Radiobiology Archive documenting distribution of formerly radioactive micro-particulates. Additionally, we use XFM to identify individual microparticles and detect daughter products of radioactive decay. The results of this proof-of-principle study support the use of XFM to map chemical element composition in historic FFPE specimens and conduct radioactive micro-particulate forensics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of machine learning methods to classify radioactive elements using prompt-gamma-ray neutron activation data

The detection of illicit radiological materials is critical to establishing a robust second line of defence in nuclear security. Neutron-capture prompt-gamma activation analysis (PGAA) can be used to detect multiple radioactive materials across the entire Periodic Table. However, long detection times and a high rate of false positives pose a significant hindrance in the deployment of PGAA-based systems to identify the presence of illicit substances in nuclear forensics. In the present work, six different machine-learning algorithms were developed to classify radioactive elements based on the PGAA energy spectra. The model performance was evaluated using standard classification metrics and trend curves with an emphasis on comparing the effectiveness of algorithms that are best suited for classifying imbalanced datasets. We analyse the classification performance based on Precision, Recall, F1-score, Specificity, Confusion matrix, ROC-AUC curves, and Geometric Mean Score (GMS) measures. The tree-based algorithms (Decision Trees, Random Forest and AdaBoost) have consistently outperformed Support Vector Machine and K-Nearest Neighbours. Based on the results presented, AdaBoost is the preferred classifier to analyse data containing PGAA spectral information due to the high recall and minimal false negatives reported in the minority class.

97 MATHEMATICS AND COMPUTING↗

Powder diffraction

Powder diffraction is a non-destructive technique, which is experimentally simple in principle. Because the physics behind diffraction is well understood, an exceptionally large amount of information can be obtained from a single measurement. The positions and relative intensities of the peaks yield a fingerprint that can be used for qualitative phase analysis. Quantitative phase analysis can be obtained by detailed analysis of the intensities. Unit cells can be derived from the peak positions. Crystal structures can be solved using powder diffraction data and refined by the Rietveld method. The peak profiles contain information about crystallite size, strain and nanostructure. Non-idealities in the intensities give information on texture. Abandoning the crystallographic model provides information about local structure, by pair distribution function analysis. For powder diffraction, everything is a sample; the technique is commonly applied to characterize minerals, ceramics, metals and alloys, catalysts, polymers, pharmaceuticals, organic compounds, environmental and forensic samples, among others. The major features of contemporary laboratory powder diffractometers are described. Methods for obtaining suitable powder specimens are summarized. Major applications of qualitative and quantitative phase analysis, structure solution, size/strain/nanostructure analysis using peak profiles, texture analysis and pair distribution function analysis are introduced.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dust to dust - How a human corpse decomposes

After death, the human body decomposes through four stages. The final, skeleton stage may be reached as quickly as two weeks or as slowly as two years, depending on temperature, humidity and other environmental conditions where the body lies. Dead bodies emit a surprising array of chemicals, from benzene to freon, which can help forensic scientists find clandestine graves.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Quantitative Analysis of Ion Mobility Spectrometry by Chemometric Multivariate Calibration

Traditional peak-area calibration and the multivariate calibration methods of principle component regression (PCR) and partial least squares (PLS), including unfolded PLS (U-PLS) and multi-way PLS (N-PLS), were evaluated for the quantification of 2,4,6-trinitrotoluene (TNT) and cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) in Composition B samples analyzed by temperature step desorption ion mobility spectrometry (TSD-IMS). The true TNT and RDX concentrations of eight Composition B samples were determined by high performance liquid chromatography with UV absorbance detection. Most of the Composition B samples were found to have distinct TNT and RDX concentrations. Applying PCR and PLS on the exact same IMS spectra used for the peak-area study improved quantitative accuracy and precision approximately 3 to 5 fold and 2 to 4 fold, respectively. This in turn improved the probability of correctly identifying Composition B samples based upon the estimated RDX and TNT concentrations from 11% with peak area to 44% and 89% with PLS. This improvement increases the potential of obtaining forensic information from IMS analyzers by providing some ability to differentiate or match Composition B samples based on their TNT and RDX concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory-based characterization of plutonium in soil particles using micro-XRF and 3D confocal XRF

The investigation of plutonium (Pu) in a soil matrix is of interest in safeguards, nuclear forensics, and environmental remediation activities. The elemental composition of two plutonium contaminated soil particles was characterized nondestructively using a pair of micro X-ray fluorescence spectrometry (micro-XRF) techniques including high resolution X-ray (hiRX) and 3D confocal XRF. The three dimensional elemental imaging capability of confocal XRF permitted the identification two distinct Pu particles within the samples: one external to the Ferich soil matrix and another co-located with Cu within the soil matrix. The size and morphology of the particles was assessed with X-ray transmission microscopy and micro X-ray computed tomography (micro-CT) providing complementary morphological information. Limits of detection for a 30 μm Pu particle are <10 ng for each of the XRF techniques. Ultimately, this study highlights the capability for lab-based, nondestructive, spatially resolved characterization of heterogeneous matrices on the micrometer scale with nanogram sensitivity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Critical Need for Plutonium and Uranium Isotopic Standards with Lower Uncertainties

Certified reference materials (CRMs) traceable to national and international safeguards database are a critical prerequisite for ensuring that nuclear measurement systems are free of systematic biases. CRMs are used to validate measurement processes associated with nuclear analytical laboratories. Diverse areas related to nuclear safeguards are impacted by the quality of the CRM standards available to analytical laboratories. These include: nuclear forensics, radio-chronometry, national and international safeguards, stockpile stewardship, nuclear weapons infrastructure and nonproliferation, fuel fabrication, waste processing, radiation protection, and environmental monitoring. For the past three decades the nuclear community is confronted with the strange situation that improvements in measurement data quality resulting from the improved accuracy and precision achievable with modern multi-collector mass spectrometers could not be fully exploited due to large uncertainties associated with CRMs available from New Brunswick Laboratory (NBL) that are used for instrument calibration and measurement control. Similar conditions prevail for both plutonium and uranium isotopic standards and for impurity element standards in uranium matrices. Herein, the current status of U and Pu isotopic standards available from NBL is reviewed. Critical areas requiring improvement in the quality of the nuclear standards to enable the U. S. and international safeguards community to utilize the full potential of modern multi-collector mass spectrometer instruments are highlighted.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Synthesis and radiometric evaluation of diglycolamide functionalized mesoporous silica for the chromatographic separation of actinides Th, Pa and U

The separation of Th, Pa, and U is of critical importance in many applications including nuclear power, nuclear waste, environmental and geochemistry, nuclear forensics and nuclear medicine. Diglycolamide (DGA)-based resins have shown the ability to separate many elements, yet, these resins consist of non-covalent impregnation of the DGA molecules on the resin backbone resulting in co-elution of the extraction molecule during separation cycles, therefore limiting their long-term and repeated use. Covalently binding the DGA molecules onto silica is one way to overcome this issue. Herein, measured equilibrium distribution coefficients of normal extraction chromatographic DGA resin and a covalently bound form (KIT-6-N-DGA sorbent) are reported. Several differences are observed between the two systems, the most significant being observed for uranium, which demonstrated significantly lower sorption behavior on KIT-6-N-DGA. These results indicate that U can effectively be separated from Th and Pa using KIT-6-N-DGA, a task that could not be completed with the use of normal DGA alone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing the solid hydrolysis product, UF 4 (H 2 O) 2.5 , generated from neat water reactions with UF 4 at room temperature

Uranium tetrafluoride (UF 4 ) is an important intermediate in the production of UF 6 and uranium metal. Room temperature hydrolysis of UF 4 was investigated using a combination of Fluorine-19 nuclear magnetic resonance spectroscopy ( 19 F NMR), Raman and infrared spectroscopy, powder X-ray diffraction, and microscopy measurements. UF 4 (H 2 O) 2.5 was identified as the primary solid hydrolysis product when anhydrous UF 4 was stirred in deionized water. Static NMR and 19 F magic angle spinning NMR measurements revealed that a small amount of uranyl fluoride can also form when anhydrous UF 4 is left in water, although this species comprises less than 5% of the total sample with the remaining parts being UF 4 (H 2 O) 2.5 . Since UF 4 is generally considered to be stable under ambient conditions, these findings mark the first time that a room temperature reaction between UF 4 and water has been detected and analyzed without interference from additional chemical reagents. The Raman characterization of UF 4 (H 2 O) 2.5 presented herein is the first on record. Since UF 4 is one of the most used intermediates during chemical conversion of uranium ore to uranium metal for nuclear fuel and weapons, the results presented herein are applicable to numerous nuclear science fields where solid state detection of uranium is of value, including nuclear nonproliferation, nuclear forensics, and environmental remediation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the hydrolytic degradation of UF 4 in humid air

This manuscript describes the chemical transformations that occur during hydrolysis of uranium tetrafluoride (UF 4 ) due to its storage in humid air (85% and 50% relative humidity) at ambient temperatures. This hydrolysis was previously reported to proceed slowly or not at all (depending on the percent relative humidity); however, previous reports relied primarily on X-ray diffraction methods to probe uranium speciation. Here, we employ a battery of physiochemical probing techniques to explore potential hydrolysis, including Raman spectroscopy, powder X-ray diffraction, 19 F nuclear magnetic resonance spectroscopy, scanning electron microscopy, and focused ion beam microscopy with energy-dispersive X-ray spectroscopy. Of these, only Raman spectroscopy proved to be particularly useful at observing chemical changes to UF 4 . It was found that anhydrous UF 4 slightly oxidizes over the course of thirteen days to Schoepite-like uranium complexes and possibly UO 3 . In contrast, UF 4 exposed to 50% relative humidity slightly decomposes into UO 2 F 2 , Schoepite-like uranium complexes, and possibly a high order uranium oxide that eluded chemical assignment (U x O y ). Despite the rich chemical speciation observed in our Raman spectroscopy measurements, X-ray diffraction and 19 F NMR measurements on the same material showed no changes. Microscopy measurements suggest that the observed reactions between UF 4 and water occur primarily on the surface of UF 4 particulates via a method that is visually similar to surface corrosion of metals. Therefore, we postulate that NMR spectroscopy and X-ray diffraction, which are well-suited for bulk analysis, are less suited than Raman spectroscopy to observe the surface-based reactions that occur to UF 4 when exposed to humid air. Considering the importance of UF 4 in the production of nuclear fuel and weapons, the results presented herein are widely applicable to numerous nuclear science fields where uranium detection and speciation in humid environments is of value, including nuclear nonproliferation and nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Development and investigation of efficient resonance ionization mass spectrometry schemes of gadolinium

Resonance ionization mass spectrometry of gadolinium can be used for nuclear forensics and to further the understanding of stellar nucleosynthesis but has been used only a handful of times due to the high laser power required and interference from non-resonant ionization of molecules of other elements. Herein we present the development of two novel resonance ionization spectroscopy schemes for gadolinium that provide improvements in isotopic fractionation and ionization efficiency, respectively, opening new applications for gadolinium analysis. The schemes are demonstrated and compared in a mixed sample of gadolinium and neodymium.

and nuclear chemistry↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗