Search NASA⌕ Search

SEARCH · Search NASA

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A pulsed power hydrodynamics approach to exploring properties of warm dense matter

Pulsed Power Hydrodynamics, as an application of low-impedance, pulsed power, and high magnetic field technology developed over the last decade to study advanced hydrodynamic problems, instabilities, turbulence, and material properties, can potentially be applied to the study of the behavior and properties of warm dense matter (WDM) as well. Exploration of the properties, such as equation of state and conductivity, of warm dense matter is an emerging area of study focused on the behavior of matter at density near solid density (from 10% of solid density to a few times solid density) and modest temperatures ({approx}1-10 eV). Warm dense matter conditions can be achieved by laser or particle beam heating of very small quantities of matter on timescales short compared to the subsequent hydrodynamic expansion timescales (isochoric heating) and a vigorous community of researchers is applying these techniques using petawatt scale laser systems, but the microscopic size scale of the WDM produced in this way limits access to some physics phenomena. Pulsed power hydrodynamics techniques, either through high convergence liner compression of a large volume, modest density, low temperature plasma to densities approaching solid density or through the explosion and subsequent expansion of a conductor (wire) against a high pressure (density) gas background (isobaric expansion) techniques both offer the prospect for producing warm dense matter in macroscopic quantities. However, both techniques demand substantial energy, proper power conditioning and delivery, and an understanding of the hydrodynamic and instability processes that limit each technique. Similarly, liner compression of normal density material, perhaps using multiple reflected shocks can provide access to the challenging region above normal density -- again with the requirement of very large amounts of driving energy. In this paper we will provide an introduction to techniques that might be applied to explore this interesting new application of the energy-rich technology of pulse power and high magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Evaluation Technique for an F/A-18 Aircraft Loads Model Using F/A-18 Systems Research Aircraft Flight Data

A limited evaluation of the F/A-18 baseline loads model was performed on the Systems Research Aircraft at NASA Dryden Flight Research Center (Edwards, California). Boeing developed the F/A-18 loads model using a linear aeroelastic analysis in conjunction with a flight simulator to determine loads at discrete locations on the aircraft. This experiment was designed so that analysis of doublets could be used to establish aircraft aerodynamic and loads response at 20 flight conditions. Instrumentation on the right outboard leading edge flap, left aileron, and left stabilator measured the hinge moment so that comparisons could be made between in-flight-measured hinge moments and loads model-predicted values at these locations. Comparisons showed that the difference between the loads model-predicted and in-flight-measured hinge moments was up to 130 percent of the flight limit load. A stepwise regression technique was used to determine new loads derivatives. These derivatives were placed in the loads model, which reduced the error to within 10 percent of the flight limit load. This paper discusses the flight test methodology, a process for determining loads coefficients, and the direct comparisons of predicted and measured hinge moments and loads coefficients.

Olney, Candida D.↗

SLAC National Accelerator Laboratory FACET & TEST BEAM FACILITIES PROPOSAL: Development of Electron Radiography for Material Science

The material science community is presently limited by diagnostics in both the fabrication of materials and measuring the resulting materials characteristics of these new fabrication techniques. Because of this limitation the community is forced into an empirical mode of material fabrication, where expert judgment is used to guide manufacturing processes and the resulting materials are inspected and tested for the desired characteristics. This development approach can be time consuming and costly. The solution to this problem is to improve our fundamental understanding of materials, which requires the development of new diagnostics capable of measurement at the micron length scale, during both processing and during testing. These new measurements will enable a fundamental understanding of material characteristics allowing the development of predictive models, which will in turn enable material engineering by design rather than today’s empirical approach. Solving this problem has become a grand challenge for the materials science community. Los Alamos plans to address this challenge through the development of new diagnostics capable of measurements at the smallest length scales through the Multi-Probe Diagnostic Hall (MPDH) at the planned MaRIE (Material and Radiation In Extremes) Facility. One of the probes will be a coherent photon beam generated by an FEL driven by a multi-GeV electron beam. The photons will be used for diffraction measurements as well as radiography of relatively thin samples (nearly single grains). The same multi-GeV electron beam can be used to directly radiograph thicker systems (many grains or “bulk” material), providing high resolution measurements of the density distribution of materials during both fabrication and dynamic testing. This technique, electron radiography or eRad, that has been identified by LANL as one of the probes required to meet this grand challenge has never been demonstrated with high energy electrons. We propose to begin development of this technique with the electron beam available at FACET.

47 OTHER INSTRUMENTATION↗

Prevention and management of silica scaling in membrane distillation using pH adjustment

Membrane scaling by silica is a major challenge in desalination, particularly for inland desalination of brackish groundwater or geothermal resources, which often contain high concentrations of silica and dissolved solids. Adjustment of feed pH may reduce silica scaling risk, which is important for inland facilities that operate at high water recoveries to reduce brine disposal costs. However, water recovery of reverse osmosis is also limited due to increased osmotic pressure with feed water concentration. Membrane distillation (MD) is a thermally driven membrane desalination technique that is not limited by increased osmotic pressure of the feed. In this investigation, pH adjustment was tested as a strategy to reduce silica scaling risk in the MD process. With feed water pH less than 5 or higher than 10, scaling impacts were negligible at silica concentrations up to 600 mg/L. Scaling rates were highest at neutral pH between 6 and 8. Cleaning strategies were also explored to remove silica scale from membranes. Cleaning using NaOH solutions at pH higher than 11 to induce dissolution of silica scale was effective at temporarily restoring performance; however, some silica remained on membrane surfaces and scaling upon re-exposure to supersaturated silica concentrations occurred faster than with new membranes.

15 GEOTHERMAL ENERGY↗

X-ray near-field speckle: implementation and critical analysis

The newly introduced coherence-based technique of X-ray near-field speckle (XNFS) has been implemented at 8-ID-I at the Advanced Photon Source. In the near-field regime of high-brilliance synchrotron X-rays scattered from a sample of interest, it turns out that, when the scattered radiation and the main beam both impinge upon an X-ray area detector, the measured intensity shows low-contrast speckles, resulting from interference between the incident and scattered beams. A micrometer-resolution XNFS detector with a high numerical aperture microscope objective has been built and its capability for studying static structures and dynamics at longer length scales than traditional far-field X-ray scattering techniques is demonstrated. Specifically, the dynamics of dilute silica and polystyrene colloidal samples are characterized. This study reveals certain limitations of the XNFS technique, especially in the characterization of static structures, which is discussed.

47 OTHER INSTRUMENTATION↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Long-Term Update of NRG Oncology RTOG 0319: A Phase 1 and 2 Trial to Evaluate 3-Dimensional Conformal Radiation Therapy Confined to the Region of the Lumpectomy Cavity for Stage I and II Breast Carcinoma

Purpose: NRG Oncology RTOG 0319 was the first cooperative group trial in the United States to evaluate 3-dimensional conformal radiation therapy (3D-CRT) accelerated partial breast irradiation (APBI). This report updates secondary endpoints of toxicity and efficacy. Methods and Materials: Patients with stage I or II invasive breast cancer (tumor size ≤3 cm, ≤3 positive lymph nodes, negative margins) were eligible for 3D-CRT APBI: 38.5 Gy in 10 twice-daily fractions. Patient characteristics and treatment details have previously been reported. Adverse events were graded with CTCAE v3.0 (National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0). This analysis updates the rates of ipsilateral breast recurrence (IBR), contralateral breast recurrence, ipsilateral node recurrence (INR), metastatic sites (distant metastases [DM]), mastectomy, disease-free survival, mastectomy-free survival, and overall survival. Results: Of 58 enrolled patients, 52 were eligible, with a median age of 61 years; 94% had stage I cancer and 83% had estrogen receptor positive disease. The median follow-up period was 8 years (minimum-maximum, 1.7-9.0 years). The 7-year estimate of isolated IBR (no DM) was 5.9%. The 7-year estimates of all IBRs, INR, mastectomy rate, and DM were 7.7%, 5.8%, 7.7%, and 7.7%, respectively. All 4 IBRs were invasive, of which 3 had a component within the planning target volume. The patterns of failure were as follows: 3 IBRs, 1 INR, 2 DM, 1 INR plus DM, and 1 IBR plus INR plus DM. The 7-year estimates of mastectomy-free survival, disease-free survival, and overall survival were 71.2%, 71.2%, and 78.8%, respectively. Thirteen patients died: 3 of breast cancer and 10 of other causes. Grade 3 (G3) treatment-related adverse events were reported by 4 patients (7.7%). No G3 pain or pulmonary or cardiac toxicities were reported. Conclusions: This phase 1 and 2 trial of 3D-CRT APBI continues to show durable tumor control and minimal G3 toxicity, comparable to other APBI techniques. Mature phase 3 results will determine the appropriateness and limitations of this noninvasive APBI technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase-locked cantilever magnetometry

We describe a feedback-based dynamic cantilever magnetometry technique capable of achieving thermal limited magnetic moment sensitivity with low applied fields. Using this technique, we have observed periodic entry of vortices into mesoscopic Sr 2 RuO 4 rings. The quantized jump in the magnetic moment of the particle produced by individual vortices was measured with a resolution of 7x10 -16 emu with an applied field of 1 Oe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emissive sheath measurements in the afterglow of a radio frequency plasma

The difference between the plasma potential and the floating potential of a highly emissive planar surface was measured in the afterglow of a radio frequency discharge. A Langmuir probe was used to measure the electron temperature and an emissive probe was used to measure the spatial distribution of the potential using the inflection point in the limit of zero emission technique. Time-resolved measurements were made using the slow-sweep method, a technique for measuring time-resolved current-voltage traces. This was the first time the inflection point in the limit of zero emission was used to make time-resolved measurements. Measurements of the potential profile of the presheath indicate that the potential penetrated approximately 50% farther into the plasma when a surface was emitting electrons. The experiments confirmed a recent kinetic theory of emissive sheaths, demonstrating that late in the afterglow as the plasma electron temperature approached the emitted electron temperature, the emissive sheath potential shrank to zero. However, the difference between the plasma potential and the floating potential of a highly emissive planar surface data appeared to be much less sensitive to the electron temperature ratio than the theory predicts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of reconstruction errors and identification of artefacts for JET gamma and neutron tomography

The Joint European Torus (JET) neutron profile monitor ensures 2D coverage of the gamma and neutron emissive region that enables tomographic reconstruction. Due to the availability of only two projection angles and to the coarse sampling, tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET, but the problem of evaluating the errors associated with the reconstructed emissivity profile is still open. The reconstruction technique based on the maximum likelihood principle, that proved already to be a powerful tool for JET tomography, has been used to develop a method for the numerical evaluation of the statistical properties of the uncertainties in gamma and neutron emissivity reconstructions. The image covariance calculation takes into account the additional techniques introduced in the reconstruction process for tackling with the limited data set (projection resampling, smoothness regularization depending on magnetic field). The method has been validated by numerically simulations and applied to JET data. Different sources of artefacts that may significantly influence the quality of reconstructions and the accuracy of variance calculation have been identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature determination of shock layer using spectroscopic techniques

Shock layer temperature profiles are obtained through analysis of radiation from shock layers produced by a blunt body inserted in an arc jet flow. Spectral measurements of N2(+) have been made at 0.5 inch, 1.0 inch, and 1.4 inches from the blunt body. A technique is developed to measure the vibrational and rotational temperatures of N2(+). Temperature profiles from the radiation layers show a high temperature near the shock front and decreasing temperature near the boundary layer. Precise temperature measurements could not be made using this technique due to the limited resolution. Use of a high resolution grating will help to make a more accurate temperature determination. Laser induced fluorescence technique is much better since it gives the scope for selective excitation and a better spacial resolution.

Akundi, Murty A.↗

Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the extent and time course of cardiac deconditioning following spaceflight or headdown tilt bed rest (HDTBR). METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR‐2), during (BR31, 70), and following (BR+4hr) HDTBR. Repeated measures ANOVA was used to evaluate the effect of HDTBR on cardiac variables in control and exercise subjects. RESULTS After sedentary HDTBR, longitudinal (‐19.0 +/- 1.8% vs. ‐14.9 +/- 2.4%) and radial (15.0 +/- 1.9% vs. 11.3 +/- 2.2%) strain and twist (18.0 +/- 4.0deg vs. 17.0 +/- 3.6deg) were significantly impaired. In contrast, exercise preserved LV mechanics, and there were non‐significant improvements from BR‐2 to BR70 in longitudinal strain (‐18.7 +/- 1.5% vs. ‐20.4 +/- 2.7%), radial strain (13.2 +/- 2.4% vs. 14.2 +/- 1.6%), and twist (16.3 +/- 3.6deg vs. 18.6 +/- 5.9deg). CONCLUSIONS Using speckle tracking echocardiography provides important new insights into temporal changes in LV mechanics during disuse and exercise training.

Scott, J. M.↗

Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

BACKGROUND Current techniques used to assess cardiac function following spaceflight or head-down tilt bed rest (HDTBR) involve invasive and time consuming procedures such as Swan-Ganz catheterization or cardiac magnetic resonance imaging. An alternative approach, echocardiography, can monitor cardiac morphology and function via sequential measurements of left ventricular (LV) mass and ejection fraction (EF). However, LV mass and EF are insensitive measures of early (subclinical) cardiac deconditioning, and a decrease in LV mass and EF become evident only once significant deconditioning has already occurred. The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the magnitude and time course of cardiac deconditioning. METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR-2), during (BR31, 70), and following (BR+4hr) HDTBR. Multi-level modeling was used to evaluate the effect of HDTBR condition (Control, Exercise) on cardiac variables. RESULTS Compared to BR-2, longitudinal (BR-2: - 19.0 +/- 1.8%; BR31: -15.9 +/- 2.4%; BR70: -14.9 +/- 2.4%; BR+4hr: -16.0 +/- 2.1%) and radial (BR-2: 15.0 +/- 1.9%; BR31: 12.3 +/- 2.4%; BR70: 11.3 +/- 2.2%; BR+4hr: 13.5 +/- 2.5% ) strains were significantly impaired during and following bed rest (p<0.05), while twist (BR-2: 18.0 +/- 4.0deg; BR31: 18.1 +/- 3.8deg; BR70: 17.0 +/- 3.6deg; BR+4hr:18.1 +/- 4.3deg) was significantly decreased at BR70 (p<0.05). In contrast, exercise preserved LV mechanics for longitudinal strain (BR-2: -19.1 +/- 1.5%; BR 31: -19.0 +/- 2.4%; BR70: -19.1 +/- 2.7%; BR+4hr: -17.8 +/- 2.1%), radial strain (BR-2: 13.8 +/- 2.4; BR31: 14.7 +/- 2.4; BR70: 14.4 +/- 1.6; BR+4hr: 14.4 +/- 2.4), and twist (BR-2: 17.8 +/- 3.6deg; BR31: 18.0 +/- 3.6deg; BR70: 18.2 +/- 5.9deg; BR+4hr: 18.3 +/- 4.2deg). CONCLUSIONS Speckle-tracking echocardiography provides important new insight into temporal changes in LV mechanics during disuse and exercise training.

Scott, Jessica M.↗

Applications of Advanced Perception and Distributed Sensing Technology towards Autonomous Advanced Air Mobility Applications

Emerging concepts for Advanced Air Mobility (AAM) envisions responsive air transportation capabilities that can safely move people and cargo between places - including local, regional, intraregional, and urban - previously not served or underserved by aviation. Expanding traditional aviation services to these environments, particularly when autonomous operations are involved, face a number of challenges that will require advances beyond the state-of-the-art techniques for airborne sensing and perception, which goes beyond the limits of scalability and applicability of the current air transportation system infrastructure. Additionally, the emerging field of distributed sensing and ‘smart spaces’– where sensing, processing, communication, and actuation are embedded in the environment in which agents are acting and can be exploited by the agents through real-time wireless communication – may provide realistic near-time solutions to limitations imposed by traditional aviation techniques. This paper outlines the needs, challenges, and opportunities for advanced perception and distributed sensing techniques to meet the emerging needs for advanced AAM operations in the national airspace. A general roadmap for research, development, and maturation of perception and distributed sensing (P&DS) technologies is proposed to guide future development through verification, validation, certification into airborne systems. Through this analysis of challenges and the proposed roadmap for technology maturation, we hope to accelerate transition of advanced research techniques from other disciplines into this domain.

Autonomy↗

Mathematical Framework Underlying the In Situ Electrochemical Diagnosis of Adsorbed Intermediates Formed during Redox Reactions at Electrode Surfaces

Previously, we have presented an electrochemical technique wherein an electroactive tracer species is employed to probe the rate-limiting factors governing redox reactions at an electrode surface. In this technique, the electrode is first held potentiostatically to facilitate a redox process (step 1), and then the potential is released to open circuit conditions (step 2) so as to monitor the time-dependent re-equilibration of the electrode potential in the presence of the tracer. The time-dependent potential response in step 2 has been shown to contain information about diffusion—limited or desorption—limited steps, enabling in situ probing of the electrochemistry at the electrode surface during step 1. In the present contribution, a theoretical model governing the transient response in step 2 is developed for two limiting cases: diffusion—limited and desorption—limited recovery of the electrode potential. Mathematical modeling shows that, during re-equilibration, the step 2 potential transient corresponding to a case where step 1 involves surface adsorbed species which undergo desorption in step 2 exhibits a much longer time constant than that when re-equilibration occurs under diffusion limitations. The mathematical framework presented herein provides a sound fundamental basis for applying the aforementioned technique to studying adsorption-desorption processes during electrochemistry. Also, technique limitations are presented in light of the modeling findings.

25 ENERGY STORAGE↗

Overcoming geometric limitations in metallic glasses through stretch blow molding

Bulk metallic glasses (BMGs) exhibit remarkable mechanical properties, such as high strength and elasticity, which is often paired with fracture toughness. Their supercooled liquid region gives rise to plastic-like processing and suggests parts and shapes that can otherwise not be obtained for crystalline metals. However, current processing techniques only allow for limited options in terms of geometry, thicknesses uniformity, and shape complexity. Here we introduce a new processing technique, “stretch blow molding,” to expand the range of possible parts and increase the available geometries that can be fabricated with BMGs. Additionally, a model is derived that allows for the quantification and prediction of stretch blow molding and provides insight into its potential use and limitations. We demonstrate that with stretch blow molding overall strains exceeding 2000% are achievable, compared to the previously reported ~150% of blow molding. With the ability to stretch blow mold shapes that were previously unachievable with any other metal fabrication technique in a fast and economical manner, and the superb properties of BMGs, we look forward to a broad commercial adaptation of this technique.

36 MATERIALS SCIENCE↗

Spaced antenna drift

It has been suggested that the spaced antenna drift (SAD) technique could be successfully used by VHF radars and that it would be superior to a Doppler-beam-swinging (DBS) technique because it would take advantage of the aspect sensitivity of the scattered signal, and might also benefit from returns from single meteors. It appears, however, that the technique suffers from several limitations. On the basis of one SAD experiment performed at the very large Jicamarca radar, it is concluded that the SAD technique can be compared in accuracy to the DBS technique only if small antenna dimensions are used.

Royrvik, O.↗

Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

Cooper, David E.↗