Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Increasing the Fissile Mass Loading of High-Level Waste Glass Canisters to Greater Than 2,500 g/m 3 at the Savannah River Site

To eliminate future fissile mass loading constraints for the Savannah River Site H-Canyon Facility and Liquid Waste system, the Savannah River National Laboratory recommends a repository evaluation of a uranium fissile mass loading in glass at 7,144 g/m 3 in addition to the existing International Atomic Energy Agency safeguards and security limit of 2,500 g/m 3 total plutonium. This recommended increase above the authorized 2,500 g/m 3 fissile mass loading limit is based on concentrations of uranium and plutonium shown to produce an acceptable glass waste form rather than projections of the maximum fissile mass loading in future sludge batches. An authorized fissile mass loading limit greater than 2,500 g/m 3 will increase facility flexibility, reduce the number of high-level waste canisters produced, and potentially avoid an increase in the Department of Energy Environmental Management mission life without compromising safety or glass product quality.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Seasonal Modulation of Crustal Seismicity in Northeastern Japan Driven by Snow Load

Numerous studies have reported that surface hydrological loading can seasonally modulate seismicity rates at crustal depths. For example, substantial winter snow accumulation occurs across the Japanese Islands, and these snowy regions appear to have seasonally modulated the occurrence of previous large inland earthquakes. Therefore, it is important to investigate the impact of seasonal stress changes on crustal seismicity to deepen our understanding of earthquake generation. Here we constrain seasonal changes in the surface load across northeastern Japan using Global Navigation Satellite System surface displacements and evaluate the potential relationship between temporal trends in inland seismicity and estimated seasonal stress changes. The spatial distribution of the seasonal surface load is consistent with snow depth along the Sea of Japan. The inland seismicity beneath northeastern Japan is modestly modulated by the seasonal stress changes that are induced by the annual snow load. However, this seasonal response is weaker than that in other regions. This weak modulation may be due to the small surface-load-induced stress perturbation relative to the long-term-averaged stressing rate and/or the limited presence of crustal fluids to trigger seismicity in Japan.

58 GEOSCIENCES↗

VRN3P: Variational Recurrent Neural Network Based Net-Load Prediction under High Solar Penetration

This is the final technical report for the SETO-funded VRN3P project (PNNL# 76914). The goal of this project, led by Pacific Northwest National Laboratory (PNNL), in collaboration with Lawrence Livermore National Laboratory (LLNL) and Portland General Electric (PGE), was to develop and validate a deep variational recurrent neural network-based net-load prediction (VRN3P) framework for probabilistic time-series forecasting of day-ahead net-load under high solar penetration scenarios. The project team reports successful design of a novel probabilistic net-load forecasting architecture, comprising of a variational autoencoder and a recurrent neural network, which demonstrates 30% improvement in forecast performance, 60% improvement in training time, and consumes 44% less memory, when compared with conventional baseline models. The team tested the VRN3P model performance on GridLAB-D test-cases representing varying BTM solar penetration levels of 20%, 30%, and 50%, with integrated time-series net-load profiles provided by the utility partner (PGE). The VRN3P model demonstrate <2% hourly MAPE (averaged over the year) for day- ahead net-load forecast on the test scenario with 20% BTM solar. Transfer learning extension of the VRN3P model has demonstrated 8.33× speed-up in training, while still achieving acceptable forecast performance of 2.24% hourly MAPE on the 30% BTM solar penetration test-scenario. A preliminary version of the VRN3P GridAPPS-D™has been developed, along with a web-based interactive user-interface (named ‘Forte’) which has made available on GitHub for public use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Waste Loading Glass Formulation Development for High-Zr HLW

This report describes work performed to develop and test new glass and feed formulations in order to increase waste loadings and glass melting rates for Hanford HLW with high concentrations of zirconium. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to evaluate the effects of waste loading on glass properties and the maximum waste loadings that can be achieved. The testing included an assessment of melt rate using a Vertical Gradient Furnace (VGF) system to develop new formulations with both high waste loadings and high melt rates. The results from crucible-scale testing supported subsequent DM100 tests designed to further assess the enhanced glass and feed formulations with respect to processing rate and product quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Estimated radiactive and shock loading of fusion reactor armor

Inertial confinement fusion (ICF) is of interest as a source of neutrons for proliferation-resistant and high burn-up fission reactor designs. ICF is a transient process, each implosion leading to energy release over a short period, with a continuous series of ICF operations needed to drive the fission reactor. ICF yields energy in the form of MeV-range neutrons and ions, and thermal x-rays. These radiations, particularly the thermal x-rays, can deposit a pulse of energy in the wall of the ICF chamber, inducing loading by isochoric heating (i.e. at constant volume before the material can expand) or by ablation of material from the surface. The explosion of the hot ICF system, and the compression of any fill material in the chamber, may also result in direct mechanical loading by a blast wave (decaying shock) reaching the chamber wall. The chamber wall must be able to survive the repetitive loading events for long enough for the reactor to operate economically. It is thus necessary to understand the loading induced by ICF systems in possible chamber wall designs, and to predict the response and life time of the wall. Estimates are given for the loading induced in the wall armor of the fusion chamber caused by ablative thermal radiation from the fusion plasma and by the hydrodynamic shock. Taking a version of the LIFE design as an example, the ablation pressure was estimated to be {approx}0.6 GPa with an approximately exponential decay with time constant {approx}0.6 ns. Radiation hydrodynamics simulations suggested that ablation of the W armor should be negligible.

42 ENGINEERING↗

Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions

Measurements of ash deposition rates were made between the secondary superheater and reheater sections of a 450 MW cyclone-fired lignite boiler as the operational load varied from 33 to 100%. Significant reductions in deposition rates with a decrease in operational load were observed. To uncover the causative mechanisms behind these observations, operational data from the power plant were used to carry out computational fluid dynamic (CFD) simulations of the boiler. After ascertaining that the gas temperatures and velocities at various sections within the boiler were being represented adequately, decoupled simulations of the ash deposition process on the deposit probe were carried out using a finely resolved boundary layer mesh. Fly ash particle size distribution (PSD) and its concentration for the decoupled calculations were determined from stand-alone cyclone barrel simulations. The ash partitioning (mass %) between the fly ash and slag was found to be ~50:50, which was in line with previous field observations, and it did not vary significantly across different cyclone loads. The predicted PSD of the deposit ash was concentrated in the size range 10–30 microns, which was in agreement with cross-sectional images of the deposit obtained from the measurements. At lower loads, sharp variations in the deposition rates were predicted in the gas temperature range 950–1150 K. The particle kinetic energy—particle viscosity-based capture methodology utilized in this study in conjunction with appropriate ash compositions, ash viscosity models and gas temperature estimates can help estimate slagging propensities at different loads reasonably well in these systems.

Krishnamoorthy, Gautham (ORCID:0000000255205092)↗

Characterization of a Human Platelet Lysate-Loaded Keratin Hydrogel for Wound Healing Applications In Vitro

One of the promising approaches to facilitate healing and regenerative capacity includes the application of growth-factor-loaded biomaterials. Human platelet lysate (hPL) derived from platelet-rich plasma through a freeze-thaw process has been used as a growth factor rich therapeutic in many regenerative applications. To provide sustained local delivery of the hPL-derived growth factors such as epidermal growth factor (EGF), the hPL can be loaded into biomaterials that do not degrade rapidly in vivo. Keratin (KSO), a strong filamentous protein found in human hair, when formulated as a hydrogel, is shown to sustain the release of drugs and promote wound healing. In the current study, we created a KSO biomaterial that spontaneously forms a hydrogel when rehydrated with hPL that is capable of controlled and sustained release of pro-regenerative molecules. Our study demonstrates that the release of hPL is controlled by changing the KSO hydrogel and hPL-loading concentrations, with hPL loading concentrations having a greater effect in changing release profiles. In addition, the 15% KSO concentration proved to form a stable hydrogel, and supported cell proliferation over 3 days without cytotoxic effects in vitro. The hPL-loaded keratin hydrogels show promise in potential applications for wound healing with the sustained release of pro-regenerative growth factors with easy tailoring of hydrogel properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Dynamic Model and Control System for Load-Following Studies of Supercritical Pulverized Coal Power Plants

Traditional energy production plants are increasingly forced to cycle their load and operate under low-load conditions in response to growth in intermittent renewable generation. A plant-wide dynamic model of a supercritical pulverized coal (SCPC) power plant has been developed in the Aspen Plus Dynamics® (APD) software environment and the impact of advanced control strategies on the transient responses of the key variables to load-following operation and disturbances can be studied. Models of various key unit operations, such as the steam turbine, are developed in Aspen Custom Modeler® (ACM) and integrated in the APD environment. A coordinated control system (CCS) is developed above the regulatory control layer. Three control configurations are evaluated for the control of the main steam; the reheat steam temperature is also controlled. For studying servo control performance of the CCS, the load is decreased from 100% to 40% at a ramp rate of 3% load per min. The impact of a disturbance due to a change in the coal feed composition is also studied. The CCS is found to yield satisfactory performance for both servo control and disturbance rejection.

20 FOSSIL-FUELED POWER PLANTS↗

Ducted Fuel Injection vs. Conventional Diesel Combustion: Extending the Load Range in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) is a technique to attenuate soot formation in compression ignition engines relative to conventional diesel combustion (CDC). The concept is to inject fuel through a small tube inside the combustion chamber to reduce equivalence ratios in the autoignition zone relative to CDC. DFI has been studied at loads as high as 8.5 bar gross indicated mean effective pressure (IMEP g ) and as low as 2.5 bar IMEP g using a four-orifice fuel injector. Across previous studies, DFI has been shown to attenuate soot emissions, increase NO x emissions (at constant charge dilution), and slightly decrease fuel conversion efficiencies for most tested points. This study expands on the previous work by testing 1.1 bar IMEPg (low-load/idle) conditions and 10 bar IMEPg (higher-load) conditions with the same four-orifice fuel injector, as well as examining potential causes of the degradations in NO x emissions and fuel conversion efficiencies. DFI and CDC are directly compared at each operating point in the study. At the low-load condition, the intake charge dilution was swept to elucidate the soot and NO x performance of DFI. The low-load range is important because it is the target of impending, more-stringent emissions regulations, and DFI is shown to be a potentially effective approach for helping to meet these regulations. The results also indicate that DFI likely has slightly decreased fuel conversion efficiencies relative to CDC. We find that the increase in NO x emissions with DFI is likely due to longer charge gas residence times at higher temperatures, which arise from shorter combustion durations and advanced combustion phasing relative to CDC.

42 ENGINEERING↗

Impact of Paint Color on Rest Period Climate Control Loads in Long-Haul Trucks: Preprint

Cab climate conditioning is one of the primary reasons for operating the main engine in a long-haul truck during driver rest periods. In the United States, sleeper cab trucks use approximately 667 million gallons of fuel annually for rest period idling. The U.S. Department of Energy's National Renewable Energy Laboratory's (NREL) CoolCab Project works closely with industry to design efficient thermal management systems for long-haul trucks that minimize engine idling and fuel use while maintaining occupant comfort. Heat transfer to the vehicle interior from opaque exterior surfaces is one of the major heat pathways that contribute to air conditioning loads during long-haul truck daytime rest period idling. To quantify the impact of paint color and the opportunity for advanced paints, NREL collaborated with Volvo Group North America, PPG Industries, and Dometic Environmental Corporation. Initial screening simulations using CoolCalc, NREL's rapid HVAC load estimation tool, showed promising air-conditioning load reductions due to paint color selection. Tests conducted at NREL's Vehicle Testing and Integration Facility using long-haul truck cab sections, 'test bucks,' showed a 31.1% of maximum possible reduction in rise over ambient temperature and a 20.8% reduction in daily electric air conditioning energy use by switching from black to white paint. Additionally, changing from blue to an advanced color-matched solar reflective blue paint resulted in a 7.3% reduction in daily electric air conditioning energy use for weather conditions tested in Colorado. National-level modeling results using weather data from major U.S. cities indicated that the increase in heating loads due to lighter paint colors is much smaller than the reduction in cooling loads.

30 DIRECT ENERGY CONVERSION↗

Sensitivity analysis of numerical modeling input parameters on floating offshore wind turbine loads in extreme idling conditions

Abstract. Floating offshore wind turbine (FOWT) systems are subject to complex environmental loads, with significant potential for damage in extreme storm conditions. Design simulations in these conditions are required to assess the survivability of the device with some level of confidence. Aero-hydro-servo-elastic engineering tools can be used with a reasonable balance of accuracy and computational efficiency. The models require many input parameters to describe the air and water conditions, the system properties, and the load calculations. Each of these parameters has some possible range, due to either statistical uncertainty or variations with time. Variation in the input parameters can have important effects on the uncertainty in the resulting loads, but it is not practical to perform detailed assessments of the impact of this uncertainty for every input parameter. This work demonstrates a method to identify the input parameters that have the most impact on the loads to focus further inspection. The process is done specifically for extreme storm load cases defined in the International Electrotechnical Commission design requirements for floating offshore wind turbines. The analysis was performed using the International Energy Agency Wind 15 MW offshore reference wind turbine atop the University of Maine VolturnUS-S reference platform in two US offshore wind regions, the Gulf of Maine and Humboldt Bay. It was found that the direction of incident waves and current, yaw misalignment, and the length of mooring line sections were among the primary sensitivities.

17 WIND ENERGY↗

Assessment of wind turbine component loads under yaw-offset conditions

Abstract. Renewed interest in yaw control for wind turbine and power plants for wake redirection and load mitigation demands a clear understanding of the effects of running with skewed inflow. In this paper, we investigate the physics of yawed operations, building up the complexity from a simplified analytical treatment to more complex aeroelastic simulations. Results in terms of damage equivalent loads (DELs) and extreme loads under misaligned conditions of operation are compared to data collected from an instrumented, utility-scale wind turbine. The analysis shows that multiple factors are responsible for the DELs of the various components and that airfoil aerodynamics, elastic characteristics of the rotor, and turbulence intensities are the primary drivers. Both fatigue and extreme loads are observed to have relatively complex trends with yaw offsets, which can change depending on the wind-speed regime. Good agreement is found between predicted and measured trends for both fatigue and ultimate loads.

Damiani, Rick↗

Effects of Accident Thermal Loading on In-Plane Shear Behavior of Steel-Plate Composite Walls

Structural walls in safety-related nuclear facilities are required to be designed for seismic and accident thermal (due to postulated high-energy pipe break events) loading combination. Current U.S. and international codes provide limited guidance for analysis and design of walls for this loading combination. This paper describes the experimental results and observations from tests conducted on a laboratory-scale (1:4 to 1:5) test unit representing steel-plate composite (SC) walls subjected to combined in-plane (seismic) and accident thermal loading. The test unit was subjected to surface temperatures of up to 450°F in combination with cyclic in-plane loading. Results of similar experiments recently conducted in Japan are also summarized (with surface temperatures up to 570°F). Surface heating combined with the low thermal conductivity and high specific heat of concrete resulted in nonlinear thermal gradients through the thickness of the specimens. These nonlinear thermal gradients and the associated self- or internal restraint led to extensive concrete cracking. This concrete cracking reduced the initial and secant stiffness of the specimens. The initial stiffness of the heated specimens reduced to 30 to 40% of the initial stiffness of the control (unheated) specimen. The secant stiffness of the heated specimens reduced up to 50% of the secant stiffness of the control (unheated) specimen. However, the in-plane shear strength of the heated SC specimens was still approximately 10 to 30% greater than the nominal in-plane shear strength calculated, for the limit state of steel plate von Mises yielding, using AISC N690 equations and measured material properties. Evaluation of the experimental results and observations suggests that the in-plane shear strength of SC walls subjected to typical accident surface temperatures (up to 570°F) can be estimated conservatively using the current provisions of AISC N690. The stiffness for accident thermal loading combinations can be considered to reduce from cracked composite stiffness at ambient temperature to fully cracked—that is, steel-only stiffness as the surface temperature increases up to typical accident value.

Construction & Building Technology↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Mechanical Behaviors of Fe75Mo5P10C7.5B2.5 Bulk Metallic Glass under Torsional Loadings

Pure- and cyclic-torsional studies were conducted on a Fe{sub 75}Mo{sub 5}P{sub 10}C{sub 7.5}B{sub 2.5} (atomic percent, at.%) bulk-metallic glass at room temperature for an understanding of its damage and fracture mechanisms. Under pure-torsional loading, the metallic glass exhibited very little plastic strain before fracture. The fracture initiated along the maximum tensile-stress plane, which is about 45{sup o} to the axial direction. The shear-fracture strength ({approx}510 MPa) is much lower than the compressive-fracture strength ({approx}3280 MPa), which suggests that different deformation mechanisms be present under various loading modes. Instead of an apparent vein-type structure, the fracture morphologies revealed a crack-initiation site, a mirror region, a mist region, and a hackle region. Under cyclic-torsional loading, fatigue cracks initiated from casting defects, and propagate generally along the maximum tensile-stress plane. A slight cyclic-hardening behavior was observed in initial loading steps. The fatigue-fracture surface consists of three main regions: the fatigue crack-initiation, crack-propagation, and final-fast-fracture areas. The striations resulting from the blunting and re-sharpening of the fatigue crack tip were observed in the crack-propagation region. Based on these results, the damage and fracture mechanisms of the metallic glass induced by torsional loadings are elucidated.

36 MATERIALS SCIENCE↗

Damage predictions of aluminum thin-walled structures subjected to explosive loads.

Predicting failure of thin-walled structures from explosive loading is a very complex task. The problem can be divided into two parts; the detonation of the explosive to produce the loading on the structure, and secondly the structural response. First, the factors that affect the explosive loading include: size, shape, stand-off, confinement, and chemistry of the explosive. The goal of the first part of the analysis is predicting the pressure on the structure based on these factors. The hydrodynamic code CTH is used to conduct these calculations. Secondly, the response of a structure from the explosive loading is predicted using a detailed finite element model within the explicit analysis code Presto. Material response, to failure, must be established in the analysis to model the failure of this class of structures; validation of this behavior is also required to allow these analyses to be predictive for their intended use. The presentation will detail the validation tests used to support this program. Validation tests using explosively loaded aluminum thin flat plates were used to study all the aspects mentioned above. Experimental measurements of the pressures generated by the explosive and the resulting plate deformations provided data for comparison against analytical predictions. These included pressure-time histories and digital image correlation of the full field plate deflections. The issues studied in the structural analysis were mesh sensitivity, strain based failure metrics, and the coupling methodologies between the blast and structural models. These models have been successfully validated using these tests, thereby increasing confidence of the results obtained in the prediction of failure thresholds of complex structures, including aircraft.

36 MATERIALS SCIENCE↗

Discrete sensing and actuation in a simulation model of frequency responsive loads

Loads acting autonomously on a local frequency signal can improve the response of a power system to sudden changes in supply, demand, or both. In this paper we address the use of load for regulating frequency by using feedback control. We extend prior research that focused on continuous proportional control, whereby one assumes that the load responds instantaneously, continuously, and in direct proportion to the changing frequency. However, sensors employed in any practical system have a finite sensitivity which introduces quantization effects into the control. As a result, a critical factor in the design of such a control is the relationship between the sensitivity of the sensor and the gain of the actuator. To study this issue, our model is constructed in two parts. The continuous dynamics of the power system is coupled to discrete event models of the sensors by state events that describe the detection points available to them. The quantized signals from the sensors are transformed by the actuators into discrete changes of load which, in turn, change the frequency and thereby complete the control loop. We illustrate the model with a scenario that involves a sudden, unanticipated change in load and the combined response of the control and power system to recover from the event.

24 POWER TRANSMISSION AND DISTRIBUTION↗