Search NASA⌕ Search

SEARCH · Search NASA

Results for “mean squared error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

SU-G-BRA-11: Tumor Tracking in An Iterative Volume of Interest Based 4D CBCT Reconstruction

Purpose: 4D CBCT can allow evaluation of tumor motion immediately prior to radiation therapy, but suffers from heavy artifacts that limit its ability to track tumors. Various iterative and compressed sensing reconstructions have been proposed to reduce these artifacts, but are costly time-wise and can degrade the image quality of bony anatomy for alignment with regularization. We have previously proposed an iterative volume of interest (I4D VOI) method which minimizes reconstruction time and maintains image quality of bony anatomy by focusing a 4D reconstruction within a VOI. The purpose of this study is to test the tumor tracking accuracy of this method compared to existing methods. Methods: Long scan (8–10 mins) CBCT data with corresponding RPM data was collected for 12 lung cancer patients. The full data set was sorted into 8 phases and reconstructed using FDK cone beam reconstruction to serve as a gold standard. The data was reduced in way that maintains a normal breathing pattern and used to reconstruct 4D images using FDK, low and high regularization TV minimization (λ=2,10), and the proposed I4D VOI method with PTVs used for the VOI. Tumor trajectories were found using rigid registration within the VOI for each reconstruction and compared to the gold standard. Results: The root mean square error (RMSE) values were 2.70mm for FDK, 2.50mm for low regularization TV, 1.48mm for high regularization TV, and 2.34mm for I4D VOI. Streak artifacts in I4D VOI were reduced compared to FDK and images were less blurred than TV reconstructed images. Conclusion: I4D VOI performed at least as well as existing methods in tumor tracking, with the exception of high regularization TV minimization. These results along with the reconstruction time and outside VOI image quality advantages suggest I4D VOI to be an improvement over existing methods. Funding support provided by CPRIT grant RP110562-P2-01.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-08: LINAC Head Geometry Modeling for Cyber Knife System

Purpose: Knowledge of the LINAC head information is critical for model based dose calculation algorithms. However, the geometries are difficult to measure precisely. The purpose of this study is to develop linac head models for Cyber Knife system (CKS). Methods: For CKS, the commissioning data were measured in water at 800mm SAD. The measured full width at half maximum (FWHM) for each cone was found greater than the nominal value, this was further confirmed by additional film measurement in air. Diameter correction, cone shift and source shift models (DCM, CSM and SSM) are proposed to account for the differences. In DCM, a cone-specific correction is applied. For CSM and SSM, a single shift is applied to the cone or source physical position. All three models were validated with an in-house developed pencil beam dose calculation algorithm, and further evaluated by the collimator scatter factor (Sc) correction. Results: The mean square error (MSE) between nominal diameter and the FWHM derived from commissioning data and in-air measurement are 0.54mm and 0.44mm, with the discrepancy increasing with cone size. Optimal shift for CSM and SSM is found to be 9mm upward and 18mm downward, respectively. The MSE in FWHM is reduced to 0.04mm and 0.14mm for DCM and CSM (SSM). Both DCM and CSM result in the same set of Sc values. Combining all cones at SAD 600–1000mm, the average deviation from 1 in Sc of DCM (CSM) and SSM is 2.6% and 2.2%, and reduced to 0.9% and 0.7% for the cones with diameter greater than 15mm. Conclusion: We developed three geometrical models for CKS. All models can handle the discrepancy between vendor specifications and commissioning data. And SSM has the best performance for Sc correction. The study also validated that a point source can be used in CKS dose calculation algorithms.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-02: An Investigation of Respiratory Surrogate Motion Data Requirements for Multiple-Step Ahead Prediction

Purpose: Respiratory-gated radiotherapy and dynamic tracking employ real-time imaging and surrogate motion-monitoring methods with tumor motion prediction in advance of real-time. This study investigated respiratory motion data length on prediction accuracy of tumor motion. Methods: Predictions generated from the algorithm are validated against a one-dimensional surrogate signal of amplitude versus time. Prediction consists of three major components: extracting top-ranked subcomponents from training data matching the last respiratory cycle; calculating weighting factors from best-matched subcomponents; fusing data proceeding best-matched subcomponents with respective weighting factors to form predictions. Predictions for one respiratory cycle (∼3-6seconds) were assessed using 351 patient data from the respiratory management device. Performance was evaluated for correlation coefficient and root mean square error (RMSE) between prediction and final respiratory cycle. Results: Respiratory prediction results fell into two classes, where best predictions for 70 cycles or less performed using relative prediction and greater than 70 cycles are predicted similarly using relative and derivative relative. For 70 respiratory cycles or less, the average correlation between prediction and final respiratory cycle was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0003, 0.9985±0.0023, and 0.9981±0.0023 with RMSE values of 0.0091±0.0030, 0.0091±0.0030, 0.0305±0.0051, 0.0299±0.0259, and 0.0299±0.0259 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 37, 65, 20, 22, and 22. For data with greater than 70 cycles average correlation was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0004, 0.9988±0.0020, and 0.9988±0.0020 with RMSE values of 0.0081±0.0031, 0.0082±0.0033, 0.0306±0.0056, 0.0218±0.0222, and 0.0218±0.0222 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 24, 44, 42, 30, and 45. Conclusion: The prediction algorithms are effective in estimating surrogate motion in advance. These results indicate an advantage in using relative prediction for shorter data and either relative or derivative relative prediction for longer data.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-10: One-Step CT Reconstruction for Metal Artifact Reduction by a Modification of Penalized Weighted Least-Squares (PWLS)

Purpose: Metal objects create severe artifacts in kilo-voltage (kV) CT image reconstructions due to the high attenuation coefficients of high atomic number objects. Most of the techniques devised to reduce this artifact utilize a two-step approach, which do not reliably yield the qualified reconstructed images. Thus, for accuracy and simplicity, this work presents a one-step reconstruction method based on a modified penalized weighted least-squares (PWLS) technique. Methods: Existing techniques for metal artifact reduction mostly adopt a two-step approach, which conduct additional reconstruction with the modified projection data from the initial reconstruction. This procedure does not consistently perform well due to the uncertainties in manipulating the metal-contaminated projection data by thresholding and linear interpolation. This study proposes a one-step reconstruction process using a new PWLS operation with total-variation (TV) minimization, while not manipulating the projection. The PWLS for CT reconstruction has been investigated using a pre-defined weight, based on the variance of the projection datum at each detector bin. It works well when reconstructing CT images from metal-free projection data, which does not appropriately penalize metal-contaminated projection data. The proposed work defines the weight at each projection element under the assumption of a Poisson random variable. This small modification using element-wise penalization has a large impact in reducing metal artifacts. For evaluation, the proposed technique was assessed with two noisy, metal-contaminated digital phantoms, against the existing PWLS with TV minimization and the two-step approach. Result: The proposed PWLS with TV minimization greatly improved the metal artifact reduction, relative to the other techniques, by watching the results. Numerically, the new approach lowered the normalized root-mean-square error about 30 and 60% for the two cases, respectively, compared to the two-step method. Conclusion: A new PWLS operation shows promise for improving metal artifact reduction in CT imaging, as well as simplifying the reconstructing procedure.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-02: Dose Reduction in Contrast-Enhanced Digital Mammography Using a Photon-Counting Detector

Purpose: Photon-counting detectors (PCDs) allow multi-energy X-ray imaging without additional exposures and spectral overlap. This capability results in the improvement of accuracy of material decomposition for dual-energy X-ray imaging and the reduction of radiation dose. In this study, the PCD-based contrast-enhanced dual-energy mammography (CEDM) was compared with the conventional CDEM in terms of radiation dose, image quality and accuracy of material decomposition. Methods: A dual-energy model was designed by using Beer-Lambert’s law and rational inverse fitting function for decomposing materials from a polychromatic X-ray source. A cadmium zinc telluride (CZT)-based PCD, which has five energy thresholds, and iodine solutions included in a 3D half-cylindrical phantom, which composed of 50% glandular and 50% adipose tissues, were simulated by using a Monte Carlo simulation tool. The low- and high-energy images were obtained in accordance with the clinical exposure conditions for the conventional CDEM. Energy bins of 20–33 and 34–50 keV were defined from X-ray energy spectra simulated at 50 kVp with different dose levels for implementing the PCD-based CDEM. The dual-energy mammographic techniques were compared by means of absorbed dose, noise property and normalized root-mean-square error (NRMSE). Results: Comparing to the conventional CEDM, the iodine solutions were clearly decomposed for the PCD-based CEDM. Although the radiation dose for the PCD-based CDEM was lower than that for the conventional CEDM, the PCD-based CDEM improved the noise property and accuracy of decomposition images. Conclusion: This study demonstrates that the PCD-based CDEM allows the quantitative material decomposition, and reduces radiation dose in comparison with the conventional CDEM. Therefore, the PCD-based CDEM is able to provide useful information for detecting breast tumor and enhancing diagnostic accuracy in mammography.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-05: Water Equivalent Path Length Calculations Using Scatter-Corrected Head and Neck CBCT Images to Evaluate Patients for Adaptive Proton Therapy

Purpose: To establish a method to evaluate the dosimetric impact of anatomic changes in head and neck patients during proton therapy by using scatter-corrected cone-beam CT (CBCT) images. Methods: The water equivalent path length (WEPL) was calculated to the distal edge of PTV contours by using tomographic images available for six head and neck patients received photon therapy. The proton range variation was measured by calculating the difference between the distal WEPLs calculated with the planning CT and weekly treatment CBCT images. By performing an automatic rigid registration, six degrees-of-freedom (DOF) correction was made to the CBCT images to account for the patient setup uncertainty. For accurate WEPL calculations, an existing CBCT scatter correction algorithm, whose performance was already proven for phantom images, was calibrated for head and neck patient images. Specifically, two different image similarity measures, mutual information (MI) and mean square error (MSE), were tested for the deformable image registration (DIR) in the CBCT scatter correction algorithm. Results: The impact of weight loss was reflected in the distal WEPL differences with the aid of the automatic rigid registration reducing the influence of patient setup uncertainty on the WEPL calculation results. The WEPL difference averaged over distal area was 2.9 ± 2.9 (mm) across all fractions of six patients and its maximum, mostly found at the last available fraction, was 6.2 ± 3.4 (mm). The MSE-based DIR successfully registered each treatment CBCT image to the planning CT image. On the other hand, the MI-based DIR deformed the skin voxels in the planning CT image to the immobilization mask in the treatment CBCT image, most of which was cropped out of the planning CT image. Conclusion: The dosimetric impact of anatomic changes was evaluated by calculating the distal WEPL difference with the existing scatter-correction algorithm appropriately calibrated. Jihun Kim, Yang-Kyun Park, Gregory Sharp, and Brian Winey have received grant support from the NCI Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-05: Monte Carlo Simulation of a Novel Multi-Layer MV Imager

Purpose: To develop and validate a Monte Carlo (MC) model of a novel multi-layer imager (MLI) for megavolt (MV) energy beams. The MC model will enable performance optimization of the MLI design for clinical applications including patient setup verification, tumor tracking and MVCBCT. Methods: The MLI is composed of four layers of converter, scintillator and light detector, each layer similar to the current clinical AS1200 detector (Varian Medical Systems, Inc). The MLI model was constructed using the Geant4 Application for Tomographic Emission (GATE v7.1) and includes interactions for x-ray photons, charged particles and optical photons. Computational experiments were performed to assess Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE) and Noise Power Spectrum normalized by photon fluence and average detector signal (qNNPS). Results were compared with experimental measurements. The current work incorporates, in one model, the complete chain of events occurring in the imager; i.e. starting from x-ray interaction to charged particle transport and energy deposition to subsequent generation, interactions and detection of optical photons. Results: There is good agreement between measured and simulated MTF, qNNPS and DQE values. Normalized root mean squared error (NRMSE) between measured and simulated values over all four layers was 2.18%, 2.43% and 6.05% for MTF, qNNPS and DQE respectively. The relative difference between simulated and measured values for qNNPS(0) was 1.68% and 1.57% for DQE(0). Current results were obtained using a 6MV Varian Truebeam™ spectrum. Conclusion: A comprehensive Monte Carlo model of the MLI prototype was developed to allow optimization of detector components. The model was assessed in terms of imaging performance using standard metrics (i.e. MTF, qNNPS, DQE). Good agreement was found between simulated and measured values. The model will be used to assess alternative detector constructions to facilitate advanced clinical imaging applications including MV-CBCT and tumor tracking. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-05: Iterative Reconstruction Via Prior Image Constrained Total Generalized Variation for Spectral CT

Purpose: To investigate iterative reconstruction via prior image constrained total generalized variation (PICTGV) for spectral computed tomography (CT) using fewer projections while achieving greater image quality. Methods: The proposed PICTGV method is formulated as an optimization problem, which balances the data fidelity and prior image constrained total generalized variation of reconstructed images in one framework. The PICTGV method is based on structure correlations among images in the energy domain and high-quality images to guide the reconstruction of energy-specific images. In PICTGV method, the high-quality image is reconstructed from all detector-collected X-ray signals and is referred as the broad-spectrum image. Distinct from the existing reconstruction methods applied on the images with first order derivative, the higher order derivative of the images is incorporated into the PICTGV method. An alternating optimization algorithm is used to minimize the PICTGV objective function. We evaluate the performance of PICTGV on noise and artifacts suppressing using phantom studies and compare the method with the conventional filtered back-projection method as well as TGV based method without prior image. Results: On the digital phantom, the proposed method outperforms the existing TGV method in terms of the noise reduction, artifacts suppression, and edge detail preservation. Compared to that obtained by the TGV based method without prior image, the relative root mean square error in the images reconstructed by the proposed method is reduced by over 20%. Conclusion: The authors propose an iterative reconstruction via prior image constrained total generalize variation for spectral CT. Also, we have developed an alternating optimization algorithm and numerically demonstrated the merits of our approach. Results show that the proposed PICTGV method outperforms the TGV method for spectral CT.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-11: Spatial and Rotational Quality Assurance of 6DOF Patient Tracking Systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations (6DOF). In this work, we develop a novel technique to evaluate the 6DOF performance of external motion tracking systems. We apply this methodology to an infrared (IR) marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to follow input trajectories with sub-millimeter and sub-degree accuracy. The 6DOF positions of the robotic system were then tracked and recorded independently by three optical camera systems. A calibration methodology which associates the motion phantom and camera coordinate frames was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20×20×16 mm and 5×5×5 degree workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the IR marker tracking system to have maximal root mean square error (RMSE) values of 0.25 mm translationally and 0.09 degrees rotationally, in any one axis, comparing intended 6DOF positions to positions measured by the IR camera. The 6DOF RSME discrepancy for the first 3D optical surface tracking unit yielded maximal values of 0.60 mm and 0.11 degrees over the same 6DOF volume. An earlier generation 3D optical surface tracker was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.74 mm and 0.28 degrees within the same 6DOF evaluation space. Conclusion: The proposed technique was effective at evaluating the performance of 6DOF patient tracking systems. All systems examined exhibited tracking capabilities at the sub-millimeter and sub-degree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-11: Anatomical and Functional Assessment of Coronary Artery Disease Using Low-Dose Whole-Organ Dynamic Computed Tomography

Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosis level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-12: Image-Based Motion Estimation for Plaque Visualization in Coronary Computed Tomography Angiography

Purpose: Visualization and quantification of coronary artery calcification and atherosclerotic plaque benefits from coronary artery motion (CAM) artifact elimination. This work applies a rigid linear motion model to a Volume of Interest (VoI) for estimating motion estimation and compensation of image degradation in Coronary Computed Tomography Angiography (CCTA). Methods: In both simulation and testbench experiments, translational CAM was generated by displacement of the imaging object (i.e. simulated coronary artery and explanted human heart) by ∼8 mm, approximating the motion of a main coronary branch. Rotation was assumed to be negligible. A motion degraded region containing a calcification was selected as the VoI. Local residual motion was assumed to be rigid and linear over the acquisition window, simulating motion observed during diastasis. The (negative) magnitude of the image gradient of the reconstructed VoI was chosen as the motion estimation objective and was minimized with Covariance Matrix Adaptation Evolution Strategy (CMAES). Results: Reconstruction incorporated the estimated CAM yielded signification recovery of fine calcification structures as well as reduced motion artifacts within the selected local region. The compensated reconstruction was further evaluated using two image similarity metrics, the structural similarity index (SSIM) and Root Mean Square Error (RMSE). At the calcification site, the compensated data achieved a 3% increase in SSIM and a 91.2% decrease in RMSE in comparison with the uncompensated reconstruction. Conclusion: Results demonstrate the feasibility of our image-based motion estimation method exploiting a local rigid linear model for CAM compensation. The method shows promising preliminary results for the application of such estimation in CCTA. Further work will involve motion estimation of complex motion corrupted patient data acquired from clinical CT scanner.

60 APPLIED LIFE SCIENCES↗

Multichannel deconvolution of vibrational signals: A state-space inverse filtering approach

Deconvolution of noisy measurements, especially when they are multichannel, has always been a challenging problem. The processing techniques developed range from simple Fourier methods to more sophisticated model-based parametric methodologies based on the underlying acoustics of the problem at hand. Methods relying on multichannel mean-squared error processors (Wiener filters) have evolved over long periods from the seminal efforts in seismic processing. However, when more is known about the acoustics, then model-based state-space techniques incorporating the underlying process physics can improve the processing significantly. The problems of interest are the vibrational response of tightly coupled acoustic test objects excited by an out-of-the-ordinary transient, potentially impairing their operational performance. Further, employing a multiple input/multiple output structural model of the test objects under investigation enables the development of an inverse filter by applying subspace identification techniques during initial calibration measurements. Feasibility applications based on a mass transport experiment and test object calibration test demonstrate the ability of the processor to extract the excitations successfully.

42 ENGINEERING↗

Bayesian estimation of HIV acquisition dates for prevention trials

Accurate timing estimates of when participants acquire HIV in HIV prevention trials are necessary for determining antibody levels at acquisition. The Antibody-Mediated Prevention (AMP) Studies showed that a passively administered broadly neutralizing antibody can prevent the acquisition of HIV from a neutralization-sensitive virus. We developed a pipeline for estimating the date of detectable HIV acquisition (DDA) in AMP Study participants using diagnostic and viral sequence data. Using a Bayesian strategy that combines three streams of data (REN [rev/vpu/env/Δnef] sequence, GP [gag/Δpol] sequence, and diagnostic) where their 95% credible intervals overlap based on pre-specified criteria and decision rules. We evaluated the performance of our AMP pipeline using PacBio viral sequence data from 41 participants across two prospective acute HIV acquisition cohort studies, FRESH and RV217, with twice-weekly sampling. These cohort studies enrolled young women in South Africa and men and women in Kenya and Thailand, respectively, with a high likelihood of HIV acquisition. In evaluating performance, “true DDA” was the center of bounds between last-negative and first-positive RNA diagnostic tests (median time 4 days, range 2–7 days); bias was the mean difference between estimated and true DDA. Using diagnostic data alone yielded timing estimates with a bias of 2.4 days and root mean square error (RMSE) of 7.9 days. These results were improved using sequence + diagnostic data (bias 1.5 days, RMSE 6.9 days), as well as by restricting sequence-based estimation to samples from ≤5 weeks post-DDA (bias 0.2 days, RMSE 7.8 days).

59 BASIC BIOLOGICAL SCIENCES↗

Selection of Spectral Variables and Improvement of the Accuracy of Calibration of Temperature by Projection onto Latent Structures Using the Fluorescence Spectra of Yb{sup 3+}:CaF{sub 2}

The efficiency of interval methods for selecting variables and the divisive method of interval optimization by a genetic algorithm is considered with the purpose to increase the accuracy of temperature calibration by projection onto latent structures. The fluorescence spectra of Yb{sup 3+}:CaF{sub 2} recorded in the 880–1120 nm band with a resolution of approximately 0.2 nm in the temperature range from 66 to 150°C in 2°C increments are used as an example. The best result for the root-mean-square error of temperature prediction in the test sample (0.45°C) was obtained by interval projection onto latent structures by a combination of moving windows. The use of methods for selecting spectral variables improved more than two times the accuracy of temperature calibration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multilevel Particle Filters

In this paper the filtering of partially observed diffusions, with discrete-time observations, is considered. It is assumed that only biased approximations of the diffusion can be obtained for choice of an accuracy parameter indexed by l. A multilevel estimator is proposed consisting of a telescopic sum of increment estimators associated to the successive levels. Additionally, the work associated to $\mathcal{O}(\varepsilon^2)$ mean-squared error between the multilevel estimator and average with respect to the filtering distribution is shown to scale optimally, for example, as $\mathcal{O}(\varepsilon^{-2})$ for optimal rates of convergence of the underlying diffusion approximation. The method is illustrated with some toy examples as well as estimation of interest rate based on real S&P 500 stock price data.

97 MATHEMATICS AND COMPUTING↗

Bayesian Static Parameter Estimation for Partially Observed Diffusions via Multilevel Monte Carlo

In this article we consider static Bayesian parameter estimation for partially observed diffusions that are discretely observed. We work under the assumption that one must resort to discretizing the underlying diffusion process, for instance, using the Euler--Maruyama method. Given this assumption, we show how one can use Markov chain Monte Carlo (MCMC) and particularly particle MCMC [C. Andrieu, A. Doucet, and R. Holenstein, J. R. Stat. Soc. Ser. B Stat. Methodol., 72 (2010), 269--342] to implement a new approximation of the multilevel (ML) Monte Carlo (MC) collapsing sum identity. Our approach comprises constructing an approximate coupling of the posterior density of the joint distribution over parameter and hidden variables at two different discretization levels and then correcting by an importance sampling method. The variance of the weights are independent of the length of the observed data set. The utility of such a method is that, for a prescribed level of mean square error, the cost of this MLMC method is provably less than i.i.d. sampling from the posterior associated to the most precise discretization. However the method here comprises using only known and efficient simulation methodologies. Finally, the theoretical results are illustrated by inference of the parameters of two prototypical processes given noisy partial observations of the process: the first is an Ornstein--Uhlenbeck process and the second is a more general Langevin equation.

97 MATHEMATICS AND COMPUTING↗