Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

An SSM/I radiometer simulator for studies of microwave emission from soil

A ground-based simulator of the defense meterological satellite program special sensor microwave/imager (DMSP SSM/I) is described, and its integration with micrometeorological instrumentation for an investigation of microwave emission from moist and frozen soils is discussed. The simulator consists of three single polarization radiometers which are capable of both Dicke radiometer and total power radiometer modes of operation. The radiometers are designed for untended operation through a local computer and a daily telephone link to a laboratory. The functional characteristics of the radiometers are described, together with their field deployment configuration and an example of performance parameters.

Galantowicz, J. F.↗

Evaluation of a fault tolerant system for an integrated avionics sensor configuration with TSRV flight data

The performance analysis results of a fault inferring nonlinear detection system (FINDS) using sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment is presented. First, a statistical analysis of the flight recorded sensor data was made in order to determine the characteristics of sensor inaccuracies. Next, modifications were made to the detection and decision functions in the FINDS algorithm in order to improve false alarm and failure detection performance under real modelling errors present in the flight data. Finally, the failure detection and false alarm performance of the FINDS algorithm were analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minute flight data. In general, the detection speed, failure level estimation, and false alarm performance showed a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed was faster for filter measurement sensors soon as MLS than for filter input sensors such as flight control accelerometers.

Caglayan, A. K.↗

Sensitive Fluorescent Determination of Cobalt by Microwave Assisted Synthesized TPTZ Functionalized Carbon Dots

Novel fluorescent carbon dots (CDs) for cobalt ions sensing were synthesized from 2,4,6-tris(2′-pyridyl)-s-triazine (TPTZ) and citric acid by microwave-assisted method in one pot. This sensor was water soluble, simple, sensitive and cheap. The size of the CDs was determined from transmission electron microscope image and was in the range of 10 nm. Under optimized experimental conditions, this luminescent system had stable response for Co (II) over a concentration range from 0.4 to 50 µM with a detection limit as low as 230 nM. The proposed method showed good sensitivity and selectivity with respect to interference ions. Finally, this system was used for Co (II) determination in tap water, river water and mineral water and B{sub 12} ampoule samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical Vapor Deposition Of Silicon Carbide

Large single-crystal SiC boules from which wafers of large area cut now being produced commerically. Availability of wafers opens door for development of SiC semiconductor devices. Recently developed chemical vapor deposition (CVD) process produces thin single-crystal SiC films on SiC wafers. Essential step in sequence of steps used to fabricate semiconductor devices. Further development required for specific devices. Some potential high-temperature applications include sensors and control electronics for advanced turbine engines and automobile engines, power electronics for electromechanical actuators for advanced aircraft and for space power systems, and equipment used in drilling of deep wells. High-frequency applications include communication systems, high-speed computers, and microwave power transistors. High-radiation applications include sensors and controls for nuclear reactors.

Powell, J. Anthony↗

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

In Situ Performance of the Low Frequency Array for Advanced ACTPol

The Advanced Atacama Cosmology Telescope Polarimeter (AdvACT) is an upgrade for the Atacama Cosmology Telescope using Transition Edge Sensor (TES) detector arrays to measure cosmic microwave background (CMB) temperature and polarization anisotropies in multiple frequencies. The low frequency (LF) array was deployed early 2020. It consists of 292 TES bolometers observing in two bands centered at 27 GHz and 39 GHz. At these frequencies, it is sensitive to synchrotron radiation from our galaxy as well as to the CMB, and complements the AdvACT arrays operating at 90, 150 and 230 GHz. We present the initial LF array on-site characterization, including the time constant, optical efficiency and array sensitivity.

Superconducting detectors↗

Performance of a low-parasitic frequency-domain multiplexing readout

Frequency-domain multiplexing is a readout technique for transition-edge sensor bolometer arrays used on modern cosmic microwave background experiments, including the SPT-3G receiver. Here, we present design details and performance measurements for a low-parasitic frequency-domain multiplexing readout. Reducing the parasitic impedance of the connections between cryogenic components provides a path to improve both the crosstalk and noise performance of the readout. Reduced crosstalk will in turn allow higher-multiplexing factors. We have demonstrated a factor of two improvement in parasitic resistance compared to SPT-3G hardware. Reduced parasitics also permits operation of lower-resistance bolometers optimized for improved readout noise performance. We demonstrate that a module in the prototype system has comparable readout noise performance to an SPT-3G module when operated with dark TES bolometers in the laboratory.

frequency-domain multiplexing↗

Assessment of Retrieved GMI Emissivity Over Land, Snow and Sea Ice in the GEOS System

Measurements from microwave sounders and imagers provide a valuable source of information including atmospheric temperature and water vapor in Numerical Weather Prediction (NWP) systems that assimilate these observations directly over water surfaces (oceans and other large water bodies). In a recent decadal survey, targeted observables in the Planetary Boundary Layer (PBL) were cited as a key need for future observations (NASEM, 2018). Microwave observations which sense in the PBL are currently available, however, utilizing surface-sensitive microwave observations for atmospheric data assimilation remains a challenge over land, snow and sea ice. This is in part due to the inability of surface emissivity models used by NWP data assimilation systems to simulate observations with sufficient accuracy. The GEOS-ADAS (Todling and el Akkraoui, 2018) which utilizes the Community Radiative Transfer Model (CRTM) (Han, 2006; Chen 2009) is no exception. The ECMWF system has retrieved instantaneous surface emissivity from surface-sensitive channels for SSMI/S and MHS radiance observations, and apply these estimates to the closest channels higher in frequency (Baordo and Geer 2016) in the calculation of simulated radiances. This approach currently is also being tested in the GEOS-ADAS for AMSU-A and ATMS radiances (Zhu et al. 2021). No or minimal emissivity spectral variability has been assumed in the above-mentioned studies. Recently, work by Munchak et al., 2020 (hereby referred to as M2020) provided a new database for emissivity over land, snow and sea ice retrieved from the NASA Global Precipitation Mission (GPM). Compared with Tool to Estimate Land Surface Emissivities at Microwave (TELSEM2; Wang et al., 2017), M2020 provides emissivities for more frequencies(i.e., 10.7 GHz V/H). Moreover, this database is unique in that it utilizes both active and passive data to retrieve surface emissivity and normalized radar cross section. While the emissivity values may be useful for other sensors, they are most applicable to the GPM Microwave Imager (GMI). In this work the GEOS-ADAS is modified to utilize emissivity values from Munchak et al, 2020 in place of values used by CRTM. Presently, only GMI radiances over ocean are used in the operational GEOS-ADAS. This study will focus on the GMI radiances over land, snow, and ice, as a first attempt to evaluate GMI radiances over these non-water surface types. Two cases are then presented, one with one week of observation minus background departures using the modified GEOS-ADAS, and one utilizing the original GEOS-ADAS. It should be noted that the surface emissivity models in CRTM are not state of the art and are scheduled to be replaced by the Community Surface Emissivity Module (CSEM; Chen and Weng, 2016). Simulations using default CRTM emissivity values are used merely as reference comparing against M2020, and is not a thorough comparison against other more state of the art modules such as CSEM.

GMI↗

Advanced ACTPol Multichroic Polarimeter Array Fabrication Process for 150 mm Wafers

Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN(sub x)) materials and microwave structures, and the resulting performance improvements.

Atacama Cosmology Telescope(ACT)↗

Silicon Carbide Solar Cells Investigated

The semiconductor silicon carbide (SiC) has long been known for its outstanding resistance to harsh environments (e.g., thermal stability, radiation resistance, and dielectric strength). However, the ability to produce device-quality material is severely limited by the inherent crystalline defects associated with this material and their associated electronic effects. Much progress has been made recently in the understanding and control of these defects and in the improved processing of this material. Because of this work, it may be possible to produce SiC-based solar cells for environments with high temperatures, light intensities, and radiation, such as those experienced by solar probes. Electronics and sensors based on SiC can operate in hostile environments where conventional silicon-based electronics (limited to 350 C) cannot function. Development of this material will enable large performance enhancements and size reductions for a wide variety of systems--such as high-frequency devices, high-power devices, microwave switching devices, and high-temperature electronics. These applications would supply more energy-efficient public electric power distribution and electric vehicles, more powerful microwave electronics for radar and communications, and better sensors and controls for cleaner-burning, more fuel-efficient jet aircraft and automobile engines. The 6H-SiC polytype is a promising wide-bandgap (Eg = 3.0 eV) semiconductor for photovoltaic applications in harsh solar environments that involve high-temperature and high-radiation conditions. The advantages of this material for this application lie in its extremely large breakdown field strength, high thermal conductivity, good electron saturation drift velocity, and stable electrical performance at temperatures as high as 600 C. This behavior makes it an attractive photovoltaic solar cell material for devices that can operate within three solar radii of the Sun.

Bailey, Sheila G.↗

Analysis of Multi-Scale Radiometric Data Collected during the Cold Land Processes Experiment-1 (CLPX-1)

Brightness temperature maps at 18.7 and 37 GHz collected at the Fraser and North Park Meso-Scale Areas during the Cold Land Processes Experiment by the NOAA Polarimetric Scanning Radiometer (PSWA) airborne sensor are analyzed. The Fraser site is mostly covered by forest with a typical snowpack depth of 1 m while North Park has no forest cover and is characterized by patches of shallow snow. We examine histograms of the brightness temperatures at 500 m resolution for both the Fraser and North Park areas. The histograms can be modelled by a log-normal distribution in the case of the Fraser MSA and by a bi-modal distribution in the case of the North Park MSA. The histograms of the brightness temperatures at coarser resolutions are also plotted to study the effects of sensor resolution on the shape of the distribution, on the values of the average brightness temperatures and standard deviations. Finally, the values of brightness temperatures obtained by re-sampling (aggregating) the data at 25 km resolution are compared with the values of the brightness temperatures collected by the Advanced Microwave Scanning Radiometer (AMSR-E) and Special Sensor Microwave/Imager (SSMII) satellite radiometers. The results show that in both areas for sensor footprint larger than 5000 m, the brightness temperatures show a flat distribution and the memory of the initial distribution is lost. The values of the brightness temperatures measured by the satellite radiometers are in good agreement with the values obtained averaging the airborne data, even if some discrepancies occur.

Tedesco, M.↗

Interactive display/graphics systems for remote sensor data analysis

A color-television display system and interactive graphics equipment on-line to an IBM 360/44 computer are used to develop a variety of interactive displays which aid in analyzing remote sensor data. These interactive displays are used to: (1) analyze data from a multispectral scanner; (2) develop automatic pattern recognition systems based on multispectral scanner measurements; and (3) analyze data from non-imaging sensors such as the infrared radiometer and microwave scatterometer.

Eppler, W. G.↗

A coactive interdisciplinary research program with NASA

The applications area of the Texas A&M University remote sensing program consists of a series of coactive projects with NASA/MSC personnel. In each case, the Remote Sensing Center has served to complement and enhance the research capability within the Manned Spacecraft Center. In addition to the applications study area, the Texas A&M University program includes coordinated projects in sensors and data analysis. Under the sensors area, an extensive experimental study of microwave radiometry for soil moisture determination established the effect of soil moisture on the measured brightness temperature for several different soil types. The data analysis area included a project which ERTS-A and Skylab data were simulated using aircraft multispectral scanner measurements at two altitudes. This effort resulted in development of a library of computer programs which provides an operational capability in classification analysis of multispectral data.

Rouse, J. W., Jr.↗

Interactive display/graphics systems for remote sensor data analysis.

Using a color-television display system and interactive graphics equipment on-line to an IBM 360/44 computer, investigators at the Manned Spacecraft Center have developed a variety of interactive displays which aid in analyzing remote sensor data. This paper describes how such interactive displays are used to: (1) analyze data from a multispectral scanner, (2) develop automatic pattern recognition systems based on multispectral scanner measurements, and (3) analyze data from nonimaging sensors such as the infrared radiometer and microwave scatterometer.

Eppler, W. G.↗

MAS2-8 radar and digital control unit

The design of the MAS 2-8 (2 to 8 GHz microwave-active spectrometer), a ground-based sensor system, is presented. A major modification in 1974 to the MAS 2-8, that of a control subsystem to automate the data-taking operation, is the prime focus. The digital control unit automatically changes all system parameters except FM rate and records the return signal on paper tape. The overall system operation and a detailed discussion of the design and operation of the digital control unit are presented.

Oberg, J. M.↗

The recovery of microwave scattering parameters from scatterometric measurements with special application to the sea

As part of an effort to demonstrate the value of the microwave scatterometer as a remote sea wind sensor, the interaction between an arbitrarily polarized scatterometer antenna and a noncoherent distributive target was derived and applied to develop a measuring technique to recover all the scattering parameters. The results are helpful for specifying antenna polarization properties for accurate retrieval of the parameters not only for the sea but also for other distributive scenes.

Claassen, J. P.↗

The SeaSat-A satellite scatterometer

This paper describes the methods used to develop performance requirements and design characteristics for the microwave scatterometer (SASS) ocean-surface wind sensor on the NASA SeaSat-A satellite. Wind vector measurement requirements from the SeaSat user community (wind speed and direction accuracy, resolution cell size, grid spacing, and swath width) define instrument characteristics. The resulting scatterometer is designed for 14.6 GHz using four fan beam antennas to measure wind speed and direction over a 1000-km swath width with a resolution cell size 50 x 50 km. Results show scatterometer accuracy satisfies user requirements for wind speed from 4 m/s to greater than 24 m/s for the nominal SeaSat-A orbit of 790 km altitude, 108 deg inclination, and 0.001 eccentricity.

Grantham, W. L.↗

Microwave multispectral investigations of snow

A long term observational program on microwave emission and scatter behavior under controlled conditions, was started at a high altitude alpine test site. All stages of development of snow cover during the whole season are under investigation. The study was done to achieve required knowledge on microwave radiative properties of snow for optimization of the microwave payloads of air and spaceborne snow sensors and for the interpretation of large scale snow maps obtained by these sensors. Preliminary results of the first month obtained with radiometers at 4.9, 10.5, 21 and 36 GHz are presented.

Schanda, E.↗