Search NASA⌕ Search

SEARCH · Search NASA

Results for “model validations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Low-Cost Sulfur Thermal Storage for Solar Industrial Process Heat Applications

Industrial process heat (IPH) is one of the largest energy demands in U.S., representing about 10% of all domestic energy consumption. Fuel costs to generate this industrial process heat are generally a top three cost for industry, a major component in American manufacturing competitiveness. Roughly 60% of US IPH demand (about 6,500 TBtu annually) falls in the medium-temperature range of 100–250 °C. While concentrated solar thermal (CST) technologies can provide a cost-effective source of heat in this temperature range, solar intermittency limits their adoption in industries that operate 24/7. Element 16 Technologies, Inc. developed a low-cost sulfur thermal energy storage (TES) technology to bridge this gap by capturing excess solar heat during the day and dispatching it reliably during non-solar hours. The core innovation is the use of sulfur, an abundant, industrial waste byproduct that costs ten times less than molten salt used in commercial TES systems. The overall goal of the project was to advance the design and development of molten sulfur TES to a manufacturing-relevant prototype stage for solar industrial process heat applications, while establishing and validating a realistic pathway to commercial success. Key tasks included corrosion and mechanical durability testing to identify cost-effective materials, design investigations using physics-based simulation tools, techno-economic evaluations of system lifetime costs, and pilot-scale testing for performance verification. Corrosion testing of steel alloys under cyclic molten sulfur conditions showed that austenitic stainless steels in the 300 series performed particularly well, with no structural degradation of welds or joints. Thermal cyclic testing of pilot sulfur TES units up to 1.5 MWh quantified charge/discharge rates, heat losses, round-trip efficiency and validated the system's capability to operate effectively under intermittent charging conditions. A techno-economic model, informed by sulfur TES performance model validated using pilot test data, showed that hybrid solar+sulfur TES+NG boiler systems are economically competitive with incumbent natural gas boilers for multiple locations in the southwest US. In summary, this project established molten sulfur TES as a technically viable pathway to improve economic competitiveness of American manufacturing by lowering the cost of solar industrial process heat.

14 SOLAR ENERGY↗

EVALUATION OF PRESSURE DROP CORRELATIONS FOR THE WIRE-WRAPPED ROD BUNDLES

The accurate prediction of pressure drop in the fuel rod bundle is of importance for the design and thermal-hydraulic analysis of nuclear reactor system. Due to very complex geometry of wire-wrapped fuel rod bundle geometry for the Sodium Fast Reactor (SFR), a simple method using hydraulic (equivalent) diameter is not sufficient to predict the pressure drop of rod bundle accurately. For several decades, many experimental works have been performed to develop an accurate correlation for wire-wrapped fuel bundle friction factor. In these works, the friction factor correlation of wire-wrapped fuel bundle has been developed as a function of Reynolds number of the flow and the design parameters such as fuel pin diameter, wire diameter, rod pitch, and wire lead length. The Cheng and Todreas correlations are well-known and used in many subchannel analysis code, such as CADET, TRIO-U, MATRA-LMW, SE2-ANL, etc. Novendstern model, Rehme model, Baxi and Dalle Donne model are also well-known and widely referred. Computational Fluid Dynamics is another typical approach to predict the pressure drop of wire-wrapped fuel rod bundle, but it requires the model validation because the accuracy of pressure drop prediction by the CFD simulation depends on what turbulence model is employed. The present work aims at evaluating the existing pressure drop correlations for the wire-wrapped fuel rod bundle and evaluating the pressure drop of 217-pin rod bundle by the CFD analysis.

99 GENERAL AND MISCELLANEOUS↗

Offshore Wind Energy Validation Experiment Hierarchy

This paper provides a summary of planning work for experiments that will be necessary to address the long-term model validation needs required to meet offshore wind energy deployment goals. Conceptual experiments are identified and laid out in a validation hierarchy for both wind turbine and wind plant applications. Instrumentation needs that will be required for the offshore validation experiments to be impactful are then listed. The document concludes with a nominal vision for how these exp

Maniaci, David Charles↗

Comparison of Fickian and temporally nonlocal transport theories over many scales in an exhaustively sampled sandstone slab

It is not a compelling argument, solely on the basis of a better fit to solute breakthrough curve (BTC) data, that a temporally nonlocal model is necessary to simulate transport in an advection-dominated system. One may counter that the classical advection-dispersion equation (ADE) is a valid model at some small scale and that the detailed hydraulic conductivity (K) data must be well-represented: then the nonlocality is only a result of upscaling and loss of information. But is the nonlocal model demonstrably necessary at all scales? We examine the experiment conducted by Klise et al. (2008) in which a 30.5 by 30.5 cm slab of relatively homogeneous, cross-bedded sandstone was exhaustively sampled for K. The slab was sealed, saturated with potassium iodide, and X-rayed 10 times while being flushed with fresh water. The 8,649 air-permeameter measurements were down- and upscaled to make finer and coarser grids on which the velocity field was solved and the ADE applied. The optimized parameters in the ADE were found to scale predictably, most notably the longitudinal dispersivity (α L ), which grew linearly with upscaling. But at all levels of up- and downscaling, including the original K measurement scale of 0.33 cm, the ADE did not adequately represent the late-time tails. The temporally nonlocal, time- fractional ADE (t-FADE) was applied and the optimized parameters (α L and the immobile capacity beta) did not depend on scale. The better fit provided by the t-FADE in the late BTC tails did not bring about a sacrificed fit elsewhere in the BTC. Furthermore, the optimized ADE and t-FADE solutions do not converge at the smallest scale, directly implying that the temporal nonlocality is a necessary model component. We conclude that the logical inference if the ADE is valid in heterogeneous material, then there is tailing in the BTC'' is not a proof that the reverse is true. We provide a clear counterexample. A corollary is that a mismatch between data and a discretized solution to the ADE does not imply that more data will improve fits or predictive ability.

58 GEOSCIENCES↗

Model Collision Operators for Numerical Gyrokinetics

We motivate the need to include collisional dissipation in gyrokinetic turbulence simulations, and construct criteria for a physically valid model of such dissipation. A new analytically manageable operator satisfying those criteria is presented and transformed into gyrokinetic variables. The form of conservation laws for collision operators in gyrokinetic variables is explained. The numerical implementation of our new operator in the code GS2 is outlined and successful tests from this code presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed parameter model and experimental validation of a compressive-mode energy harvester under harmonic excitations

This paper presents the modeling and parametric analysis of the recently proposed nonlinear compressive-mode energy harvester (HC-PEH) under harmonic excitation. Both theoretical and experimental investigations are performed in this study over a range of excitation frequencies. Specially, a distributed parameter electro-elastic model is analytically developed by means of the energy-based method and the extended Hamilton’s principle. An analytical formulation of bending and stretching forces are derived to gain insight on the source of nonlinearity. Furthermore, the analytical model is validated against with experimental data and a good agreement is achieved. Both numerical simulations and experiment illustrate that the harvester exhibits a hardening nonlinearity and hence a broad frequency bandwidth, multiple coexisting solutions and a large-amplitude voltage response. Using the derived model, a parametric study is carried out to examine the effect of various parameters on the harvester voltage response. It is also shown from parametric analysis that the harvester’s performance can be further improved by selecting the proper length of elastic beams, proof mass and reducing the mechanical damping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of mixed grain size sediment input on braided river Morphodynamics: Insights from experimental and numerical modeling

The rate of sediment supply has significant impacts on river morphology, making it crucial to understand the geomorphic changes and grain size distribution dynamics in rivers. However, the effects of varying grain size sediment input on morphological changes in braided channels remain poorly understood. This study is the first to investigate the bar development and sediment sorting processes in braided channels with non-uniform sediment inputs using both numerical and experimental approaches. We applied a two-dimensional numerical model, Nays2DH to confirm and generalize experimental results. The model reproduced key experiment results, including 1) stream elevation changes, and 2) grain size distribution. Using this validated model, we explored the morphological changes and sorting process in a braided river with sediment inputs. The numerical experiments demonstrate that sediment input controls the elevation of the stream bed and the grain size distribution. Notably, both the elevation and grain-size distribution become relatively stable in downstream of the channel. Additionally, the simulation results suggest that an increased sediment supply leads to greater channel complexity, with bed surface armoring decreasing.

Nays2DH↗

National Atmospheric Release Advisory Center dispersion modeling of the Full-scale Radiological Dispersal device (FSRDD) field trials

The results of the National Atmospheric Release Advisory Center (NARAC) model simulations are compared to measured data from the Full-Scale Radiological Dispersal Device (FSRDD) field trials. The series of explosive radiological dispersal device (RDD) experiments was conducted in 2012 by Defence Research and Development Canada (DRDC) and collaborating organizations. During the trials, a wealth of data was collected, including a variety of deposition and air concentration measurements. The experiments were conducted with one of the stated goals being to provide measurements to atmospheric dispersion modelers. These measurements can be used to facilitate important model validation studies. For this study, meteorological observations recorded during the tests are input to the diagnostic meteorological model, ADAPT, which provides 3–D, time-varying mean wind and turbulence fields to the LODI dispersion model. LODI concentration and deposition results are compared to the measured data, and the sensitivity of the model results to changes in input conditions (such as the particle activity size distribution of the source) and model physics (such as the rise of the buoyant cloud of explosive products) is explored. The NARAC simulations predicted the experimentally measured deposition results reasonably well considering the complexity of the release. Lastly, changes to the activity size distribution of the modeled particles can improve the agreement of the model results to measurement.

54 ENVIRONMENTAL SCIENCES↗

Dual technicolor with hidden local symmetry

We consider a dual description of the technicolor-like gauge theory within the D4/D8-brane configuration with varying confinement and electroweak symmetry breaking scales. Constructing an effective truncated model valid below a certain cutoff, we identify the particle spectrum with Kaluza-Klein modes of the model in a manner consistent with the hidden local symmetry. Integrating out heavy states, we find that the low-energy action receives nontrivial corrections stemming from the mixing between standard model and heavy gauge bosons, which results in reduction of oblique parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adaptive RAS/SPS System Settings for Improving Grid Reliability and Asset Utilization through Predictive Simulation and Controls

Remedial Action Schemes (RAS) or Special Protection Schemes (SPS) are used throughout the bulk transmission system as a non-wires method of increasing transmission transfer capability. However, as the population grows within the Western Interconnection, more power needs to be transferred with less ability to build lines. This leads to a greater number of RAS, and the subsequent interaction between these disparate schemes can have unintended consequences. While the large number of RAS within the Western Electricity Coordinating Council (WECC) protect for different things, which can range from the violation of thermal limitations to transient stability issues, they can be described by common methods of operation. In order to understand these methods, a survey was sent out to members of the WECC Modeling & Validation Working Group (MVWG). The response received provides a necessary base in which to understand and build models that can be used within WECC. This report provides information on the survey results regarding RAS/SPS modeling practices for planning and operational studies within the WECC footprint, which is foundational for on-going and future work on RAS. Pacific Northwest National Laboratory (PNNL) and its industry partners are developing innovative methods for adaptively setting RAS parameters based on realistic and near real-time operational conditions to improve power grid reliability and grid asset utilization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Staged Pressurized Oxy Combustion (SPOC): Improving Flexibility and Performance at Reduced Cost

Staged Pressurized Oxy-Combustion (SPOC) is a coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Traditional oxy-combustion plants remove most of the nitrogen in air prior to combustion, thereby burning fuel in oxygen instead of air, producing a flue gas containing primarily CO 2 and water that allows relatively simple CO 2 capture at amounts > 90%. This technology relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. The SPOC process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing the recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is up to 6 percentage points greater than traditional atmospheric-pressure oxy-combustion, representing a step-change improvement over first-generation oxy-combustion technologies. WUSTL has teamed up with the Electric Power Research Institute, Inc., American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to develop a practicable and workable boiler design concept associated with the application of SPOC. In particular, due to the staged nature of the heat release, the team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants. Improved flexibility is a critical need as coal power plants are being tasked with providing grid stability to balance the growth of intermittent renewables. Not only is flexible operation important, achieving efficient power generation at reduced loads will be key as the plants are likely to operate in this regime for significant periods of time as more renewables become available. At reduced loads, coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and to a lesser extent the main steam due to the heat transfer characteristics of these circuits when flue gas quantities are lower. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. Since the SPOC process can be configured to deliver targeted heat input to each boiler circuit by adjusting the relative fuel firing rate of each stage, better temperature control can be achieved during dynamic conditions. Oxygen supply flexibility is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Testing results and model validation that form the basis of a full-scale boiler design that will encompass both efficiency and flexibility improvements over conventional oxy-combustion processes will be presented.

20 FOSSIL-FUELED POWER PLANTS↗

Thermal Performance of Vegetative Roofing Systems

Vegetative roofing, otherwise known as green or garden roofing, has seen tremendous growth in the last decade in the United States. The numerous benefits that green roofs provide have helped to fuel their resurgence in industrial and urban settings. There are many environmental and economical benefits that can be realized by incorporating a vegetative roof into the design of a building. These include storm-water retention, energy conservation, reduction in the urban heat island effect, increased longevity of the roofing membrane, the ability of plants to create biodiversity and filter air contaminants, and beautification of the surroundings by incorporating green space. The vegetative roof research project at Oak Ridge National Laboratory (ORNL) was initiated to quantify the thermal performance of various vegetative roofing systems relative to black and white roofs. Single Ply Roofing Institute (SPRI) continued its long-term commitment to cooperative research with ORNL in this project. Low-slope roof systems for this study were constructed and instrumented for continuous monitoring in the mixed climate of East Tennessee. This report summarizes the results of the annual cooling and heating loads per unit area of three vegetative roofing systems with side-by-side comparison to black and white roofing systems as well as a test section with just the growing media without plants. Results showed vegetative roofs reduced heat gain (reduced cooling loads) compared to the white control system due to the thermal mass, extra insulation, and evapo-transpiration associated with the vegetative roofing systems. The 4-inch and tray systems reduced the heat gain by approximately 61%, while the reduction with the 8-inch vegetative roof was found to be approximately 67%. The vegetative roofing systems were more effective in reducing heat gain than in reducing heat losses (heating loads). The reduction in heat losses for the 4-inch and tray systems were found to be approximately 40% in the mixed climate of East Tennessee. It should be noted that these values are climate dependent. Vegetative roofs also reduced the temperature (heat exposure) and temperature fluctuations (thermal stress) experienced by the membrane. In the cooling season of East Tennessee, the average peak temperature of the 4-inch and tray systems was found to be approximately 94 F cooler than the control black roofing system. The average temperature fluctuations at the membrane for the 4-inch and tray systems were found to be approximately 10 F compared to 125 F for black and 64 F for white systems. As expected, the 8-inch vegetative roof had the lowest fluctuations at approximately 2 F. Future work will include modeling of the energy performance of vegetative roof panels in the test climate of East Tennessee. The validated model then will be used to predict energy use in roofs with different insulation levels and in climates different from the test climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An advanced membrane-based HMX model and its application in utilizing sensible and latent heat removed in space cooling

This paper presents a comprehensive simulation model for advanced membrane-based heat and mass exchanger (HMX) components which account for three separate fluid streams with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl and ionic liquid (IL)). Preliminary model validation is presented using data from a laboratory prototype absorber. The paper also presents implementation of the model into a sorption system modeling platform and analyzes potential benefit analysis of the HMX component in utilizing the sensible and latent heat removed in space cooling to heat water. The developed model and codes are expected to enable detailed optimization studies and identify novel configurations for the three-fluid HMX maximum performance and cost effectiveness.

Gao, Zhiming↗

Hydrogen Storage System Modeling: Public Access, Maintenance, and Enhancements

This presentation summarizes the Fiscal Year 2020 status and accomplishments for the Hydrogen Storage System Modeling project, a collaborative effort to manage, update, and enhance hydrogen storage system models developed under the Hydrogen Storage Engineering Center of Excellence (HSECoE). The project goal is to provide validated modeling tools that will be used by researchers to evaluate the performance of their new materials in engineered systems relative to the DOE technical targets.

AMR↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Experimental modal analysis of SSR1 cryomodule for numerical model tuning and validation

The present activity aims to test the Cryomodule SSR1 to validate the corresponding mixed multibody-finite element numerical model and to determine the range of frequencies in which the first natural modes of the structure lie. The experimental activity consisted of a hammer test of the cryomodule at an early assembly stage at which the internal parts, constituting the cold mass, are accessible and, thus, many accelerometers can be attached to the beam string. The comparison between the experimental results obtained for the sub-assembly and the numerical results obtained for the corresponding sub-model, derived from the previously developed complete model, allowed to assess the validity of the numerical model and to get feedback on the effectiveness of the placement of the sensors in capturing the dynamic response of the system during transportation.

43 PARTICLE ACCELERATORS↗

Modelling the Sensitivity of Yukon River Biogeochemical Dynamics to Environmental and Chemical Drivers: Implications for Dissolved Organic Carbon

Riverine dissolved organic carbon (DOC) is a critical biogeochemical component that transmits information from Arctic soils to the Arctic Ocean, significantly influencing carbon dynamics in this unique ecosystem. As DOC travels downstream, it undergoes transformations that alter its composition and fate. The Yukon River serves as an effective testbed for modelling these dynamics, offering sufficient scale to capture key biogeochemical processes while having a simpler hydrology than other major Arctic rivers, as well as long-term DOC observational data for model validation. To investigate DOC transformations during transit in the Yukon River, we adapted our Arctic Riverine Organic Macromolecular Model by applying regional-specific parameterisations. Our model simulates the transport and transformation of 15 organic macromolecules, including CDOM (coloured dissolved organic matter), proteins, polysaccharides, lipids, lignin phenols, and humic substances. Initial DOC concentrations were derived from observed soil organic carbon stocks in the surrounding watershed, while chemical transformations and hydrological dynamics were modelled along the river's course. Sensitivity and uncertainty analyses were conducted using a Monte Carlo approach under two experimental setups. Results revealed that variability in DOC and CDOM concentrations at the river mouth were predominantly driven by initial DOC concentration (~70% of variability explained) and dilution at confluence points (~10%). The refractory fraction of DOC explained 21%–88% of the variability in 14 macromolecular concentrations and ranked in the top five sensitive parameters for all outputs when a uniform parameter distribution was assumed. However, when a more likely variability was applied to this parameter, its influence on DOC and CDOM decreased. Given that refractory DOC accounts for ~80% of total DOC in Arctic Rivers, this suggests that most DOC resists degradation and retains its chemical composition during transport to the coastal environment. River velocity, which determines residence time, explained 8%–47% of the variability in protein, polysaccharide, lipid, pigments, and lignin phenols at the river mouth. In contrast, chemical turnover times contributed only 1%–5% to output variability. Our findings underscore the need for improved land-specific headwater observations, including seasonal soil moisture and lateral transport dynamics that control the initial tributary-specific DOC inputs. With accelerated permafrost thaw and increasing river discharge, extending our model to other Arctic River systems and seasons will enhance understanding of Arctic riverine carbon fluxes and their contributions to the Arctic Ocean.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Stress Field and Fracture Development During Shale Maturation Using Analog Rock Systems

The emergence of hydrocarbons within shale as a major recoverable resource has sparked interest in fluid transport through these tight mudstones. Recent studies suggest the importance to recovery of microfracture networks that connect localized zones with large organic content to the inorganic matrix. This paper presents a joint modeling and experimental study to examine the onset, formation, and evolution of microfracture networks as shale matures. Both the stress field and fractures are simulated and imaged. A novel laboratory-scale, phase-field fracture propagation model was developed to characterize the material failure mechanisms that play a significant role during the shale maturation process. The numerical model developed consists of coupled solid deformation, pore pressure, and fracture propagation mechanisms. Benchmark tests were conducted to validate model accuracy. Laboratory-grade gelatins with varying Young’s modulus were used as scaled-rock analogs in two dimensional Hele-Shaw cell apparatus. Yeast within the gelatin generates gas in a fashion analogous to hydrocarbon formation as shale matures. These setups allow study and visualization of host rock elastic-brittle fracture and fracture network propagation mechanisms. The experimental setup was fitted to utilize photoelasticity principles coupled with birefringence properties of gelatin to explore visually the stress field of the gelatin as the fracture network developed. Stress optics image analysis and Linear Elastic Fracture Mechanics (LEFM) principles for crack propagation were used to monitor fracture growth for each gelatin type. Observed and simulated responses suggest gas diffusion within and deformation of the gelatin matrix as predominant mechanisms for energy dissipation depending on gelatin strength. LEFM, an experimental estimation of principal stress development with fracture growth, at different stages was determined for each gelatin rheology. Here, the interplay of gas diffusion and material deformation determines the resulting frequency and pattern of fractures. Results correlate with Young’s modulus. Experimental and computed stress fields reveal that fractures resulting from internal gas generation are similar to, but not identical to, type 1 opening mode.

58 GEOSCIENCES↗