Search NASA⌕ Search

SEARCH · Search NASA

Results for “process data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A novel proposal for all optical half-subtractor based on photonic crystals

Optical logic devices are the inevitable need for the future all optical computing and data processing. In this paper we are going to design and propose an all optical half subtractor using photonic crystal structure. The proposed structure will be realized using both threshold switching and beam interference. Finite difference time domain method used for analyzing the proposed structure. The simulation results show that the contrast ratio for D and B ports are 8 dB and 12 dB respectively. Also the maximum the maximum rise and fall times are 1 ps and 0.6 ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utah FORGE: LBNL Reports on VEMP Electromagnetic Data Collection and Processing - 2024

This archive contains reports related to Vertical Electromagnetic Profiling (VEMP) tool data collection and processing at Utah FORGE in 2024. The first report describes LBNL's effort to collect electromagnetic geophysical data with the tool in well 78-32B and a downhole electrode in well 16A. The second report describes the final data acquisition and processing of the VEMP electromagnetic data collected at the Utah FORGE site in May of 2024. Also included are a noise analysis as well as a comparison of the data to numerical models. This was originally presented as a paper at the 2025 Stanford Geothermal Workshop.

15 GEOTHERMAL ENERGY↗

Development and evaluation of a portable CZT coded aperture gamma-camera

We present the design and the evaluation of a CdZnTe (CZT) based gamma camera using a coded aperture mask. This camera, based on a 8 cm{sup 3} detection module, is small enough to be portable and battery-powered (4 kg weight and 4 W power dissipation). As the detector has spectral capabilities, the gamma camera allows isotope identification and colored imaging, by affecting one color channel to each identified isotope. As all data processing is done at real time, the user can directly observe the outcome of an acquisition and can immediately react to what he sees. We first present the architecture of the system, how the detector works, and its performances. After, we focus on the imaging technique used and its strengths and limitations. Finally, results concerning sensitivity, spatial resolution, field of view and multi-isotope imaging are shown and discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acid–Base Properties of Azo Dyes in Solution Studied Using Spectrophotometry and Colorimetry

Colorimetry and spectrophotometry with chemometric data processing were used to study the acid–base properties of azo dyes in aqueous solution. The capabilities of both methods were compared. Ionization constants of all the functional groups of the azo compounds studied could be determined relative to the change in the specific color difference depending on the acidity of the medium. The colorimetric functions of ion-molecular forms of azo compounds used as an analytical signal allow us to obtain complete information on the acid–base equilibrium in a wide acidity range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dusty plasma in a glow discharge in helium in temperature range of 5–300 K

Dusty plasma structures in glow discharge in helium in the temperature range of 5–300 K are investigated experimentally. We have described the experimental setup that makes it possible to continuously vary the temperature regime. The method for experimental data processing has been described. We have measured interparticle distances in the temperature range of 9–295 K and compared them with the Debye radius. We indicate the ranges of variations in experimental parameters in which plasma–dust structures are formed and various types of their behavior are manifested (rotation, vibrations of structures, formation of vertical linear chains, etc.). The applicability of the Yukawa potential to the description of the structural properties of a dusty plasma in the experimental conditions is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds to a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called “The Weighing of Inversely as Lipschitz Constants” (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

All optical half subtractor using photonic crystal based nonlinear ring resonators

All optical subtractors are one of the optical digital devices that will play crucial roles in the next generation all optical data processing. In this paper we used three nonlinear photonic crystal based ring resonators for designing a novel structure for realizing all optical half subtractor. In the proposed structure X and Y are the input ports and D and B are the output ports. D is on when one of the input ports is ON and the other is OFF, however B is ON only when X is ON and Y is OFF. The maximum rise times for D and B are 2 ps and 3 ps respectively. Also the maximum fall times for D and B both are about 1 ps.

42 ENGINEERING↗

TakeTwo : an indexing algorithm suited to still images with known crystal parameters

The indexing methods currently used for serial femtosecond crystallography were originally developed for experiments in which crystals are rotated in the X-ray beam, providing significant three-dimensional information. On the other hand, shots from both X-ray free-electron lasers and serial synchrotron crystallography experiments are still images, in which the few three-dimensional data available arise only from the curvature of the Ewald sphere. Traditional synchrotron crystallography methods are thus less well suited to still image data processing. Here, a new indexing method is presented with the aim of maximizing information use from a still image given the known unit-cell dimensions and space group. Efficacy for cubic, hexagonal and orthorhombic space groups is shown, and for those showing some evidence of diffraction the indexing rate ranged from 90% (hexagonal space group) to 151% (cubic space group). Here, the indexing rate refers to the number of lattices indexed per image.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of magnetic parameters in La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} thin films using EMCD

It is well known that the magnetic state of the La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO) thin-film heterostructure is strongly correlated with the lattice, spin, orbital, and charge states, since these influence the electric and magnetic transport properties even on the unit-cell level. Therefore, understanding the material's magnetic properties on the nanoscale is important for the development of novel applications. The recently developed electron magnetic-circular dichroism (EMCD) technique allows the determination of atomic site-specific magnetic information via the use of transmitted electrons; however, its sensitivity is not high enough to quantitatively acquire magnetic information in many weak magnetism systems. Here, we utilized a dynamical diffraction-effect assisted EMCD technique to quantitatively determine the spin and orbital magnetic moment of LSMO/SrTiO{sub 3} thin films on the nanometer scale using a transmission electron microscope. Further, data processing was optimized to enhance the intensity of the EMCD signals for manganese, which have very weak magnetism at room temperature. High signal-to-noise ratio and accurate quantitative magnetic measurement are eventually achieved. Finally, the spin magnetic moments (0.73 ± 0.26 μ{sub B}) are derived, and we also limited the ratio of the orbital to spin magnetic moment within an interval of (−0.03, 0.01). Our results not only present the nanoscale magnetic parameters of LSMO/SrTiO{sub 3}, but also demonstrate how the measurement limit of the spin (or orbital) magnetic moment can be achieved, which is via the developed dynamical diffraction effect assisted EMCD technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-207A-06: On-Line Beam Range Verification with Multiple Scanning Particle Beams: Initial Feasibility Study with Simulations

Purpose: To investigate the feasibility and requirement for intra-fraction on-line multiple scanning particle beam range verifications (BRVs) with in-situ PET imaging, which is beyond the current single-beam BRV with extra factors that will affect the BR measurement accuracy, such as beam diameter, separation between beams, and different image counts at different BRV positions. Methods: We simulated a 110-MeV proton beam with 5-mm diameter irradiating a uniform PMMA phantom by GATE simulation, which generated nuclear interaction-induced positrons. In this preliminary study, we simply duplicated these positrons and placed them next to the initial protons to approximately mimic the two spatially separated positron distributions produced by two beams parallel to each other but with different beam ranges. These positrons were then imaged by a PET (∼2-mm resolution, 10% sensitivity, 320×320×128 mm^3 FOV) with different acquisition times. We calculated the positron activity ranges (ARs) from reconstructed PET images and compared them with the corresponding ARs of original positron distributions. Results: Without further image data processing and correction, the preliminary study show the errors between the measured and original ARs varied from 0.2 mm to 2.3 mm as center-to-center separations and range differences were in the range of 8–12 mm and 2–8 mm respectively, indicating the accuracy of AR measurement strongly depends on the beam separations and range differences. In addition, it is feasible to achieve ≤ 1.0-mm accuracy for both beams with 1-min PET acquisition and 12 mm beam separation. Conclusion: This study shows that the overlap between the positron distributions from multiple scanning beams can significantly impact the accuracy of BRVs of distributed particle beams and need to be further addressed beyond the established method of single-beam BRV, but it also indicates the feasibility to achieve accurate on-line multi-beam BRV with further improved method.

60 APPLIED LIFE SCIENCES↗

A Collimated CZT Detector for Quantitative Gamma Assays - 17250

Cadmium-Zinc-Telluride [CZT] detectors for gamma spectroscopic measurements and room-temperature operation have had a long history of promising good performance. Very small detectors [0.05-0.5 cm{sup 3}] have been commercially available for many years, but their small size creates problems for spectroscopy because of very low photopeak efficiency, especially at medium and high energies. Large CZT [4-6 cm{sup 3}] detectors have been shown to work nicely in a research environment when complicated electronic and data processing algorithms are applied. We report here test results from a commercially available 1 cubic centimeter CZT detector housed in a portable custom Tungsten shield with a set of collimators with different apertures. The detector has 2-2.5% FWHM resolution at Cs-137 energies, and near-Gaussian shaped peaks. Efficiency calibrations can be quickly made for a wide variety of geometries using the ISOCS mathematical efficiency software. We show successful validation tests comparing accuracy of measurements on reference calibration point sources, line sources, and 200 liter drums. The low weight of the device [9 kg including the shield and collimator] and low power [powered via USB from the PC] makes these devices particularly suitable for human-deployed in-situ measurements of large objects containing medium levels of activity - e.g. characterization of objects encountered during decommissioning, emergency response, truck alarm investigation, or waste being shipped to a disposal facility. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a reliable assessment of charging effects during surface analysis: Accurate spectral shapes of ZrO 2 and Pd/ZrO 2 via X-ray Photoelectron Spectroscopy

X-ray Photoelectron Spectroscopy of large bandgap or insulating material surfaces relies on an effective mechanism that compensates for the emission (loss) of electrons by maintaining the material surface at a steady-state uniform potential. While a steady-state may be attained by utilizing an active compensation, such as low power electron emitting filament, there is the possibility that the surface potential is not uniform over the area analyzed, leading to peak shifts and incorrect spectral interpretation. Here, in this work, a spectral data processing method based on mapping the ZrO 2 and Pd/ZrO 2 surfaces utilizing photoemission peak binding energy is proposed, which provides information about the response of specific material surfaces to charge compensation. Spectromicroscopy of ZrO 2 and Pd/ZrO 2 surfaces without spatial information is used to monitor the efficacy of charge compensation. Exploiting counts distributed over many bins require the use of procedures and algorithms essential to practical mapping peak positions. Iterative singular value decomposition is therefore introduced and utilized as a means of efficiently delivering spatially resolved spectra from which binding energy for peaks is computed. The concepts developed in this work result in robust and accurate peak models of ZrO 2 and Pd/ZrO 2 that can be applied in XPS analysis of not only ZrO 2 but other large bandgap or insulating material surfaces. Supporting arguments for a peak model representing signal from Zr 3p and Pd 3d are developed within this work are presented.

36 MATERIALS SCIENCE↗

Magnetization reversal in magnetic dot arrays: Nearest-neighbor interactions and global configurational anisotropy

Various proposals for future magnetic memories, data processing devices, and sensors rely on a precise control of the magnetization ground state and magnetization reversal process in periodically patterned media. In finite dot arrays, such control is hampered by the magnetostatic interactions between the nanomagnets, leading to the non-uniform magnetization state distributions throughout the sample while reversing. In this paper, we evidence how during reversal typical geometric arrangements of dots in an identical magnetization state appear that originate in the dominance of either Global Configurational Anisotropy or Nearest-Neighbor Magnetostatic interactions, which depends on the fields at which the magnetization reversal sets in. Based on our findings, we propose design rules to obtain the uniform magnetization state distributions throughout the array, and also suggest future research directions to achieve non-uniform state distributions of interest, e.g., when aiming at guiding spin wave edge-modes through dot arrays. Our insights are based on the Magneto-Optical Kerr Effect and Magnetic Force Microscopy measurements as well as the extensive micromagnetic simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Segmentation of nanotomographic cortical bone images for quantitative characterization of the osteoctyte lacuno-canalicular network

A newly developed data processing method able to characterize the osteocytes lacuno-canalicular network (LCN) is presented. Osteocytes are the most abundant cells in the bone, living in spaces called lacunae embedded inside the bone matrix and connected to each other with an extensive network of canals that allows for the exchange of nutrients and for mechanotransduction functions. The geometrical three-dimensional (3D) architecture is increasingly thought to be related to the macroscopic strength or failure of the bone and it is becoming the focus for investigating widely spread diseases such as osteoporosis. To obtain 3D LCN images non-destructively has been out of reach until recently, since tens-of-nanometers scale resolution is required. Ptychographic tomography was validated for bone imaging in [1], showing clearly the LCN. The method presented here was applied to 3D ptychographic tomographic images in order to extract morphological and geometrical parameters of the lacuno-canalicular structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use of the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences.

60 APPLIED LIFE SCIENCES↗

A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities

Purpose: To develop a physical, adaptive motion perturbation model to predict tumor motion using feedback from dynamic measurement of breathing conditions to compensate for breathing irregularities. Methods and Materials: A novel respiratory motion perturbation (RMP) model was developed to predict tumor motion variations caused by breathing irregularities. This model contained 2 terms: the initial tumor motion trajectory, measured from 4-dimensional computed tomography (4DCT) images, and motion perturbation, calculated from breathing variations in tidal volume (TV) and breathing pattern (BP). The motion perturbation was derived from the patient-specific anatomy, tumor-specific location, and time-dependent breathing variations. Ten patients were studied, and 2 amplitude-binned 4DCT images for each patient were acquired within 2 weeks. The motion trajectories of 40 corresponding bifurcation points in both 4DCT images of each patient were obtained using deformable image registration. An in-house 4D data processing toolbox was developed to calculate the TV and BP as functions of the breathing phase. The motion was predicted from the simulation 4DCT scan to the treatment 4DCT scan, and vice versa, resulting in 800 predictions. For comparison, noncorrected motion differences and the predictions from a published 5-dimensional model were used. Results: The average motion range in the superoinferior direction was 9.4 ± 4.4 mm, the average ΔTV ranged from 10 to 248 mm{sup 3} (−26% to 61%), and the ΔBP ranged from 0 to 0.2 (−71% to 333%) between the 2 4DCT scans. The mean noncorrected motion difference was 2.0 ± 2.8 mm between 2 4DCT motion trajectories. After applying the RMP model, the mean motion difference was reduced significantly to 1.2 ± 1.8 mm (P=.0018), a 40% improvement, similar to the 1.2 ± 1.8 mm (P=.72) predicted with the 5-dimensional model. Conclusions: A novel physical RMP model was developed with an average accuracy of 1.2 ± 1.8 mm for interfraction motion prediction, similar to that of a published lung motion model. This physical RMP was analytically derived and is able to adapt to breathing irregularities. Further improvement of this RMP model is under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consumption study and identification of methyl salicylate in spicy cassava chips

Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students’ pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam’s addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive control was 1.273 mg/mL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible-light Phase Curves from the Second Year of the TESS Primary Mission

We carried out a systematic study of full-orbit phase curves for known transiting systems in the northern ecliptic sky that were observed during Year 2 of the TESS primary mission. We applied the same methodology for target selection, data processing, and light-curve fitting as we did in our Year 1 study. Out of the 15 transiting systems selected for analysis, seven—HAT-P-7, KELT-1, KELT-9, KELT-16, KELT-20, Kepler-13A, and WASP-12—show statistically significant secondary eclipses and day–night atmospheric brightness modulations. Small eastward dayside hot-spot offsets were measured for KELT-9b and WASP-12b. KELT-1, Kepler-13A, and WASP-12 show additional phase-curve variability attributed to the tidal distortion of the host star; the amplitudes of these signals are consistent with theoretical predictions. We combined occultation measurements from TESS and Spitzer to compute dayside brightness temperatures, TESS-band geometric albedos, Bond albedos, and phase integrals for several systems. The new albedo values solidify the previously reported trend between dayside temperature and geometric albedo for planets with 1500 K < T {sub day} < 3000 K. For Kepler-13Ab, we carried out an atmospheric retrieval of the full secondary eclipse spectrum, which revealed a noninverted temperature–pressure profile, significant H{sub 2}O and K absorption in the near-infrared, evidence for strong optical atmospheric opacity due to sodium, and a confirmation of the high geometric albedo inferred from our simpler analysis. We explore the implications of the phase integrals (ratios of Bond to geometric albedos) for understanding exoplanet clouds. We also report updated transit ephemerides for all of the systems studied in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗