Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Multirate digital control system design

Methods for multirate digital control system design are discussed. A simple method for sampling rate selection based on control bandwidths is proposed. Methods for generating a discrete-time state model of a sampled-data plant and a discrete-time equivalent to an analog cost function for a sampled-data plant are described. The succesive loop closures and linear quadratic Gaussian synthesis methods are reviewed, and a constrained optimization synthesis method is introduced. The proposed sampling rate selection, discretization, and synthesis methods are applied to two example design problems. Multirate and single-rate compensators synthesized by the different methods are compared, based on closed-loop responses, with compensators having the same real-time computation load.

Berg, Martin C.↗

An extension of command shaping methods for controlling residual vibration using frequency sampling

The authors present an extension to the impulse shaping technique for commanding machines to move with reduced residual vibration. The extension, called frequency sampling, is a method for generating constraints that are used to obtain shaping sequences which minimize residual vibration in systems such as robots whose resonant frequencies change during motion. The authors present a review of impulse shaping methods, a development of the proposed extension, and a comparison of results of tests conducted on a simple model of the space shuttle robot arm. Frequency shaping provides a method for minimizing the impulse sequence duration required to give the desired insensitivity.

Singer, Neil C.↗

A general few-projection method for tomographic reconstruction of samples consisting of several distinct materials

We present a method for tomographic reconstruction of objects containing several distinct materials, which is capable of accurately reconstructing a sample from vastly fewer angular projections than required by conventional algorithms. The algorithm is more general than many previous discrete tomography methods, as: (i) a priori knowledge of the exact number of materials is not required; (ii) the linear attenuation coefficient of each constituent material may assume a small range of a priori unknown values. We present reconstructions from an experimental x-ray computed tomography scan of cortical bone acquired at the SPring-8 synchrotron.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Meteorite Porosity Using Liquid Nitrogen

We introduce a new harmless method for porosity measurement suitable for meteorite samples. The method is a modification of the traditional Archimedean method based on immersion of the samples in a liquid medium like water or organic liquids. In our case we used liquid nitrogen for its chemically inert characteristics.

Kohout, T.↗

Method and apparatus for remote sensing of molecular species at nanoscale utilizing a reverse photoacoustic effect

A method and apparatus for identifying a sample, involves illuminating the sample with light of varying wavelengths, transmitting an acoustic signal against the sample from one portion and receiving a resulting acoustic signal on another portion, detecting a change of phase in the acoustic signal corresponding to the light of varying wavelengths, and analyzing the change of phase in the acoustic signal for the varying wavelengths of illumination to identify the sample. The apparatus has a controlled source for illuminating the sample with light of varying wavelengths, a transmitter for transmitting an acoustic wave, a receiver for receiving the acoustic wave and converting the acoustic wave to an electronic signal, and an electronic circuit for detecting a change of phase in the acoustic wave corresponding to respective ones of the varying wavelengths and outputting the change of phase for the varying wavelengths to allow identification of the sample. The method and apparatus can be used to detect chemical composition or visual features. A transmission mode and a reflection mode of operation are disclosed. The method and apparatus can be applied at nanoscale to detect molecules in a biological sample.

Su, Ming↗

Towards utility-scale electronic structure with sample-based quantum bootstrap embedding

One of the main applications for which quantum computers are hoped to find utility is in simulating ground state energies and other observables of molecular chemical systems. The recently proposed sample-based diagonalization method is a readily implementable method for this task on current-day hardware using short circuit depths and has been demonstrated on as many as 85 qubits in recent studies. In this work, we combine the recently proposed quantum bootstrap embedding (QBE) method with sampled-based diagonalization (QBE-SQD) and present the first benchmarking study of the QBE method on real quantum hardware, ibm_pittsburgh, a Heron r3 processor with 156 qubits. Our test system is a hydrogen ring with 8 hydrogen atoms in the cc-pVDZ basis. We show that for this system, QBE-SQD using an active space of (8e, 19o) per fragment with a 43 qubit footprint produces a ground state energy accuracy which exceeds that of an SQD calculation with an (8e, 30o) active space with a 67 qubit footprint when using a comparable number of Slater determinants. This demonstrates that the use of quantum bootstrap embedding techniques is a promising path towards extending the capabilities of state-of-the-art quantum eigensolvers on near-term devices.

Bierman, Joel [North Carolina State University, Ra↗

Analysis methods for quantifying Xe-127 samples from the UNESE project

In the Underground Nuclear Explosions Signatures Experiment (UNESE) radioactive 37 Ar and 127 Xe were used as tracers in subsurface migration experiments. As part of the experiment, methods were developed to quantify 127 Xe via β-γ coincidence spectroscopy. Later examination of the results highlighted a weakness of this analysis method in samples with no 127 Xe present, so a reanalysis of samples was performed to identify those which were falsely identified as having 127 Xe present. Ongoing work to develop a new analysis method with targeted regions of interest is also described. Measurements were also performed to quantify the concentration of 127 Xe and 37 Ar which were injected as part of UNESE Phase 2. A best value for the concentration of 37 Ar and 127 Xe was determined and reported here for use in future analyses of the UNESE Phase 2 results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

MCCCS-MN

The MCCCS‒MN (Monte Carlo for Complex Chemical Systems‒Minnesota) software is developed by the Siepmann research group at the University of Minnesota. MCCCS‒MN allows for the simulation of multi-component molecular systems in the canonical, isobaric-isothermal (including constant stress for solids), grand-canonical, semi-grand, and Gibbs (NVT, NPT, and more than two simulation boxes) ensembles. It uses the configurational-bias Monte Carlo method to efficiently sample phase space for linear, branched and cyclic chain molecules, the adiabatic nuclear and electronic sampling Monte Carlo method to treat many-body polarization effects, and the aggregation-volume-bias Monte Carlo algorithm to efficiently sample the spatial distribution of associating molecules. MCCCS-MN employs a molecular representation of the system where force fields contain bonded and non-bonded terms. Funding for the development of MCCCS-MN through grants from the National Science Foundation (simulation of fluid phase equilibria and chromatography) and the Department of Energy (simulation of adsorption equilibria) is gratefully acknowledged.

Siepmann, J.Ilja [University of Minnesota - Twin C↗

Effects of Sample Preparation on the Infrared Reflectance Spectra of Powders

While reflectance spectroscopy is a useful tool in identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-packed as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.

FTIR↗

Application of modern autoradiography to nuclear forensic analysis

Modern autoradiography techniques based on phosphorimaging technology using image plates (IPs) and digital scanning can identify heterogeneities in activity distributions and reveal material properties, serving to inform subsequent analyses. Here, we have adopted these advantages for applications in nuclear forensics, the technical analysis of radioactive or nuclear materials found outside of legal control to provide data related to provenance, production history, and trafficking route for the materials. IP autoradiography is a relatively simple, non-destructive method for sample characterization that records an image reflecting the relative intensity of alpha and beta emissions from a two-dimensional surface. Such data are complementary to information gathered from radiochemical characterization via bulk counting techniques, and can guide the application of other spatially resolved techniques such as scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS). IP autoradiography can image large 2-dimenstional areas (up to 20 × 40 cm), with relatively low detection limits for actinides and other radioactive nuclides, and sensitivity to a wide dynamic range (10 5 ) of activity density in a single image. Distributions of radioactivity in nuclear materials can be generated with a spatial resolution of approximately 50 μm using IP autoradiography and digital scanning. While the finest grain silver halide films still provide the best possible resolution (down to ~10 μm), IP autoradiography has distinct practical advantages such as shorter exposure times, no chemical post-processing, reusability, rapid plate scanning, and automated image digitization. Sample preparation requirements are minimal, and the analytical method does not consume or alter the sample. These advantages make IP autoradiography ideal for routine screening of nuclear materials, and for the identification of areas of interest for subsequent micro-characterization methods. Here in this article we present a summary of our setup, as modified for nuclear forensic sample analysis and related research, and provide examples of data from select samples from the nuclear fuel cycle and historical nuclear test debris.

07 ISOTOPE AND RADIATION SOURCES↗

RAPID METHOD FOR DETERMINATION OF RADIOSTRONTIUM IN EMERGENCY MILK SAMPLES

A new rapid separation method for radiostrontium in emergency milk samples was developed at the Savannah River Site (SRS) Environmental Bioassay Laboratory (Aiken, SC, USA) that will allow rapid separation and measurement of Sr-90 within 8 hours. The new method uses calcium phosphate precipitation, nitric acid dissolution of the precipitate to coagulate residual fat/proteins and a rapid strontium separation using Sr Resin (Eichrom Technologies, Darien, IL, USA) with vacuum-assisted flow rates. The method is much faster than previous method that use calcination or cation exchange pretreatment, has excellent chemical recovery, and effectively removes beta interferences. When a 100 ml sample aliquot is used, the method has a detection limit of 0.5 Bq/L, well below generic emergency action levels.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Digital redesign of continuous systems by matching of states at multiple sampling periods

This paper presents a method of digital approximation of a continuous-data system by the matching of states at multiple sampling periods. Two alternate methods are presented; one method samples the states every sampling period, and alters the forward and feedback gains, so as to match the states of the two systems at the end of N sampling periods. The second method requires the sampling of the states every N sampling periods, with the change of gains at each sampling period. An illustrative example using the one-axis dynamics of the Skylab Satellite is presented.

Yackel, R. A.↗

RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Accounting for Incomplete Species Detection in Fish Community Monitoring

Riverine fish assemblages are heterogeneous and very difficult to characterize with a one-size-fits-all approach to sampling. Furthermore, detecting changes in fish assemblages over time requires accounting for variation in sampling designs. We present a modeling approach that permits heterogeneous sampling by accounting for site and sampling covariates (including method) in a model-based framework for estimation (versus a sampling-based framework). We snorkeled during three surveys and electrofished during a single survey in suite of delineated habitats stratified by reach types. We developed single-species occupancy models to determine covariates influencing patch occupancy and species detection probabilities whereas community occupancy models estimated species richness in light of incomplete detections. For most species, information-theoretic criteria showed higher support for models that included patch size and reach as covariates of occupancy. In addition, models including patch size and sampling method as covariates of detection probabilities also had higher support. Detection probability estimates for snorkeling surveys were higher for larger non-benthic species whereas electrofishing was more effective at detecting smaller benthic species. The number of sites and sampling occasions required to accurately estimate occupancy varied among fish species. For rare benthic species, our results suggested that higher number of occasions, and especially the addition of electrofishing, may be required to improve detection probabilities and obtain accurate occupancy estimates. Community models suggested that richness was 41% higher than the number of species actually observed and the addition of an electrofishing survey increased estimated richness by 13%. These results can be useful to future fish assemblage monitoring efforts by informing sampling designs, such as site selection (e.g. stratifying based on patch size) and determining effort required (e.g. number of sites versus occasions).

fish sampling↗

Rapid determination of radiostrontium in seawater samples

A new method for the determination of radiostrontium in seawater samples has been developed at the Savannah River National Laboratory (SRNL) that allows rapid preconcentration and separation of strontium and yttrium isotopes in seawater samples for measurement. The new SRNL method employs a novel and effective pre-concentration step that utilizes a blend of calcium phosphate with iron hydroxide to collect both strontium and yttrium rapidly from the seawater matrix with enhanced chemical yields. The pre-concentration steps, in combination with rapid Sr Resin and DGA Resin cartridge separation options using vacuum box technology, allow seawater samples up to 10 liters to be analyzed. The total 89 Sr + 90 Sr activity may be determined by gas flow proportional counting and recounted after ingrowth of 90 Y to differentiate 89 Sr from 90 Sr. Gas flow proportional counting provides a lower method detection limit than liquid scintillation or Cerenkov counting and allows simultaneous counting of samples. Simultaneous counting allows for longer count times and lower method detection limits without handling very large aliquots of seawater. Seawater samples up to 6 liters may be analyzed using Sr Resin for 89 Sr and 90 Sr with a Minimum Detectable Activity (MDA) of 1-10 mBq/L, depending on count times. Seawater samples up to 10 liters may be analyzed for 90 Sr using a DGA Resin method via collection and purification of 90 Y only. If 89 Sr and other fission products are present, then 91 Y (beta energy 1.55 MeV, 58.5 day half-life) is also likely to be present. 91 Y interferes with attempts to collect 90 Y directly from the seawater sample without initial purification of Sr isotopes first and 90 Y ingrowth. The DGA Resin option can be used to determine 90 Sr, and if 91 Y is also present, an ingrowth option with using DGA Resin again to collect 90 Y can be performed. An MDA for 90 Sr of <1 mBq/L for an 8 hour count may be obtained using 10 liter seawater sample aliquots.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multiple Lines of Evidence

This paper discusses the process of identifying factors that influence the contamination level of a given decision area and then determining the likelihood that the area remains unacceptable. This process is referred to as lines of evidence. These lines of evidence then serve as inputs for the stratified compliance sampling (SCS) method, which requires a decision area to be divided into strata based upon contamination expectations. This is done in order to focus sampling efforts more within stratum where contamination is more likely and to use the domain knowledge about these likelihoods of the stratum remaining unacceptable to buy down the number of samples necessary, if possible. Two different building scenarios were considered as an example (see Table 3.1). SME expertise was elicited concerning four lines of evidence factors (see Table 3.2): 1) amount of contamination that was seen before decontamination, 2) post-decontamination air sampling information, 3) the applied decontaminant information, and 4) the surface material. Statistical experimental design and logistic regression modelling were used to help determine the likelihood that example stratum remained unacceptable for a given example scenario. The number of samples necessary for clearance was calculated by applying the SCS method to the example scenario, using the estimated likelihood of each stratum remaining unacceptable as was determined using the lines of evidence approach. The commonly used simple random sampling (SRS) method was also used to calculate the number of samples necessary for clearance for comparison purposes. The lines of evidence with SCS approach resulted in a 19% to 43% reduction in total number of samples necessary for clearance (see Table 3.6). The reduction depended upon the building scenario, as well as the level of percent clean criteria. A sensitivity analysis was also performed showing how changing the estimated likelihoods of stratum remaining unacceptable affect the number of samples necessary. In conclusion, using the lines of evidence approach with the SCS method can reduce sample sizes when SME are able to identify factors that reduce the likelihood that an area remain unacceptable.

97 MATHEMATICS AND COMPUTING↗

Methods for point-of-care detection of nucleic acid in a sample

Provided herein are methods and apparatus for detecting a target nucleic acid in a sample and related methods and apparatus for diagnosing a condition in an individual. The condition is associated with presence of nucleic acid produced by certain pathogens in the individual.

59 BASIC BIOLOGICAL SCIENCES↗