At least 865 records · Page 48

Automated cloud screening of AVHRR imagery using split-and-merge clustering

Previous methods to segment clouds from ocean in AVHRR imagery have shown varying degrees of success, with nighttime approaches being the most limited. An improved method of automatic image segmentation, the principal component transformation split-and-merge clustering (PCTSMC) algorithm, is presented and applied to cloud screening of both nighttime and daytime AVHRR data. The method combines spectral differencing, the principal component transformation, and split-and-merge clustering to sample objectively the natural classes in the data. This segmentation method is then augmented by supervised classification techniques to screen clouds from the imagery. Comparisons with other nighttime methods demonstrate its improved capability in this application. The sensitivity of the method to clustering parameters is presented; the results show that the method is insensitive to the split-and-merge thresholds.

Gallaudet, Timothy C.↗

Preliminary study of nuclear fuel element testing based on coded source neutron imaging

Neutron radiography (NR) is one of the most important nondestructive testing methods, which is sensitive to low density materials. Especially, Neutron transfer imaging method could be used to test radioactivity materials refraining from γ effect, but it is difficult to realize tomography. Coded source neutron imaging (CSNI) is a newly NR method developed fast in the last several years. The distance between object and detector is much longer than traditional NR, which could be used to test radioactivity materials. With pre-reconstruction process from fold-cover projections, CSNI could easily realize tomography. This thesis carries out preliminary study on the nuclear fuel element testing by coded source neutron imaging. We calculate different enrichment, flaws and activity in nuclear fuel elements tested by CSNI with Monte-Carlo simulation. The results show that CSNI could be a useful testing method for nuclear fuel element testing. (authors)

42 ENGINEERING↗

Shape design sensitivity analysis using domain information

A numerical method for obtaining accurate shape design sensitivity information for built-up structures is developed and demonstrated through analysis of examples. The basic character of the finite element method, which gives more accurate domain information than boundary information, is utilized for shape design sensitivity improvement. A domain approach for shape design sensitivity analysis of built-up structures is derived using the material derivative idea of structural mechanics and the adjoint variable method of design sensitivity analysis. Velocity elements and B-spline curves are introduced to alleviate difficulties in generating domain velocity fields. The regularity requirements of the design velocity field are studied.

Seong, Hwal-Gyeong↗

A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow and critical parameters is presented. • The method could provide a useful tool to complement existing chemical assays.

60 APPLIED LIFE SCIENCES↗

Performance analysis of structured gradient algorithm

The structured gradient algorithm uses a structured estimate of the array correlation matrix (ACM) to estimate the gradient required for the constrained least-mean-square (LMS) algorithm. This structure reflects the structure of the exact array correlation matrix for an equispaced linear array and is obtained by spatial averaging of the elements of the noisy correlation matrix. In its standard form the LMS algorithm does not exploit the structure of the array correlation matrix. The gradient is estimated by multiplying the array output with the receiver outputs. An analysis of the two algorithms is presented to show that the covariance of the gradient estimated by the structured method is less sensitive to the look direction signal than that estimated by the standard method. The effect of the number of elements on the signal sensitivity of the two algorithms is studied.

Godara, Lal C.↗

Is the assumption of normality or log-normality for continuous response data critical for benchmark dose estimation?

Continuous responses (e.g. body weight) are widely used in risk assessment for determining the benchmark dose (BMD) which is used to derive a U.S. EPA reference dose. One critical question that is not often addressed in dose–response assessments is whether to model the continuous data as normally or log-normally distributed. Additionally, if lognormality is assumed, and only summarized response data (i.e., mean ± standard deviation) are available as is usual in the peer-reviewed literature, the BMD can only be approximated. In this study, using the “hybrid” method and relative deviation approach, we first evaluate six representative continuous dose–response datasets reporting individual animal responses to investigate the impact on BMD/BMDL estimates of (1) the distribution assumption and (2) the use of summarized versus individual animal data when a log-normal distribution is assumed. We also conduct simulation studies evaluating model fits to various known distributions to investigate whether the distribution assumption has influence on BMD/BMDL estimates. Our results indicate that BMDs estimated using the hybrid method are more sensitive to the distribution assumption than counterpart BMDs estimated using the relative deviation approach. The choice of distribution assumption has limited impact on the BMD/BMDL estimates when the within dose-group variance is small, while the lognormality assumption is a better choice for relative deviation method when data are more skewed because of its appropriateness in describing the relationship between mean and standard deviation. Additionally, the results suggest that the use of summarized data versus individual response data to characterize log-normal distributions has minimal impact on BMD estimates. - Highlights: • We investigate to what extent the distribution assumption can affect BMD estimates. • Both real data analysis and simulation study are conducted. • BMDs estimated using hybrid method are more sensitive to distribution assumption. • Summarized continuous data are adequate for BMD estimation.

60 APPLIED LIFE SCIENCES↗

Sensitivity analysis of homogenized cross section in AP1000 lattices

The two-step method for light water reactor simulation consists of performing lattice-level calculations to determine homogenized properties of the lattice for a variety of configurations and burnups then performing a core-level calculation which relies on those pre-calculated lattice properties. Calculating the homogenized lattice properties for the specific conditions needed in the core-level calculation relies on interpolating from the pre-calculated lattice properties. Although many studies have explored different models that can be used for this interpolation, there is a need to explore how to appropriately parameterize the lattice for those interpolation models. The present study uses linear sensitivity methods to determine the sensitivity of homogenized cross sections to both instantaneous and historical values of state variables. The results from this study can be used to inform parameterizations which more appropriately capture history effects in homogenized cross section interpolation. Two different lattices are used for this analysis from the AP1000 reactor, one includes burnable absorbers. It was found that early in the cycle, the historical values of state variables have little effect on the instantaneous value of the homogenized cross sections explored here - especially in the case of the lattice containing burnable absorbers. However, it was found that later in the cycle, the thermal fission homogenized cross section was sensitive to the historic states of the lattice. In fact, using the average of a state variable as a predictor for interpolation models may be insufficient for capturing historic effects due to more recent states having larger sensitivity measures than less recent states. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human Gut Microbiota from Autism Spectrum Disorder Promote Behavioral Symptoms in Mice

Large-scale phosphoproteomics with coverage of over 10,000 sites of phosphorylation have now been routinely achieved with advanced mass spectrometry (MS)-based workflows. However, accurate targeted MS-based quantification of phosphorylation dynamics, an important direction for gaining quantitative understanding of signaling pathways or networks, has been much less investigated. Herein, we report an assessment of the targeted workflow in the context of signal transduction pathways, using the epidermal growth factor receptor (EGFR)–mitogen-activated protein kinase (MAPK) pathway as our model. 43 phosphopeptides from the EGFR–MAPK pathway were selected for the study. The recovery and sensitivity of a workflow consisted of two commonly used enrichment methods, immobilized metal affinity chromatography (IMAC) and titanium oxide (TiO2), combined with selected reaction monitoring (SRM)-MS, were evaluated. The recovery of phosphopeptides by IMAC and TiO2 enrichment was quantified to be 38 ± 5% and 58 ± 20%, respectively, based on internal standards. Moreover, both enrichment methods provided comparable sensitivity from 1-100 g starting peptides. Robust quantification was consistently achieved for most targeted phosphopeptides when starting with 25-100 g peptides. However, the numbers of quantified targets significantly dropped when peptide samples were in the 1-25g range. Finally, IMAC-SRM was applied to quantify signaling dynamics of EGFR-MAPK pathway in Hs578T cells following 3 ng/mL EGF treatment. The kinetics of phosphorylation clearly revealed early and late phases of phosphorylation, even for very low abundance proteins. These results demonstrate the feasibility of robust targeted quantification of phosphorylation dynamics for specific pathways, even starting with relatively small amounts of protein.

Sharon, Gil↗

Targeted Quantification of Phosphorylation Dynamics in the Context of EGFR-MAPK Pathway

Large-scale phosphoproteomics with coverage of over 10,000 sites of phosphorylation have now been routinely achieved with advanced mass spectrometry (MS)-based workflows. However, accurate targeted MS-based quantification of phosphorylation dynamics, an important direction for gaining quantitative understanding of signaling pathways or networks, has been much less investigated. Herein, we report an assessment of the targeted workflow in the context of signal transduction pathways, using the epidermal growth factor receptor (EGFR)–mitogen-activated protein kinase (MAPK) pathway as our model. 43 phosphopeptides from the EGFR–MAPK pathway were selected for the study. The recovery and sensitivity of a workflow consisted of two commonly used enrichment methods, immobilized metal affinity chromatography (IMAC) and titanium oxide (TiO2), combined with selected reaction monitoring (SRM)-MS, were evaluated. The recovery of phosphopeptides by IMAC and TiO2 enrichment was quantified to be 38 ± 5% and 58 ± 20%, respectively, based on internal standards. Moreover, both enrichment methods provided comparable sensitivity from 1-100 g starting peptides. Robust quantification was consistently achieved for most targeted phosphopeptides when starting with 25-100 g peptides. However, the numbers of quantified targets significantly dropped when peptide samples were in the 1-25g range. Finally, IMAC-SRM was applied to quantify signaling dynamics of EGFR-MAPK pathway in Hs578T cells following 3 ng/mL EGF treatment. The kinetics of phosphorylation clearly revealed early and late phases of phosphorylation, even for very low abundance proteins. These results demonstrate the feasibility of robust targeted quantification of phosphorylation dynamics for specific pathways, even starting with relatively small amounts of protein.

Environmental Molecular Sciences Laboratory↗

Heuristic optimization in penumbral image for high resolution reconstructed image

Penumbral imaging is a technique which uses the fact that spatial information can be recovered from the shadow or penumbra that an unknown source casts through a simple large circular aperture. The size of the penumbral image on the detector can be mathematically determined as its aperture size, object size, and magnification. Conventional reconstruction methods are very sensitive to noise. On the other hand, the heuristic reconstruction method is very tolerant of noise. However, the aperture size influences the accuracy and resolution of the reconstructed image. In this article, we propose the optimization of the aperture size for the neutron penumbral imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing Gas Diffusion in LXe-TPCs for Upcoming Hydrogen Doping Studies [Poster]

Liquid xenon time projection chambers (LXe-TPCs) currently lead the direct-detection search for dark matter (DM) in the form of weakly interacting massive particles (WIMPs). However, sensitivity is currently limited to DM with masses above 5 GeV/c². Hydrogen doping in LXe-TPCs would allow for better kinematic matching between light DM particles and target nuclei, expanding sensitivity to DM masses down to 200 MeV/c². Additionally, this method would introduce sensitivity to spindependent DM. So far, no major experiments have explored this parameter space. Plans are underway to dope an existing small-scale LXe-TPC (XELDA) with H₂ to study behavior and mixing properties in LXe. This will include measuring the Henry coefficient and characterizing the charge-to-light spectrum of H₂ recoils in LXe. Prior to this, it is important to determine an expected time scale of H₂ diffusion and saturation in our TPC.

43 PARTICLE ACCELERATORS↗

Flutter-Constrained Optimization with the Linearized Frequency-Domain Approach

Due to the high computational cost associated with unsteady aeroelastic analysis, state-of-the-art aeroelastic optimizations based on computational fluid dynamics typically ignore critical constraints like flutter and aeroelastic gust response. The linearized frequency-domain method offers an approach for adding high-fidelity flutter constraints to multidisciplinary optimizations at relatively low cost compared to other unsteady computational fluid dynamics methods. In recent work, sensitivities have been implemented for the linearized frequency-domain method in FUN3D. In this work, the linearized frequency-domain method and associated sensitivities are applied to gradient-based aeroelastic optimization with flutter constraints based on computational fluid dynamics. An overview of the flutter constraint formulation and implementation is provided, and then two optimization problems are presented. The first optimization increases the flutter speed of a pitch and plunge airfoil at transonic conditions using the minimal amount of geometric changes. The second optimization minimizes the mass of the AGARD 445.6 wing subject to a flutter constraint.

Aeroelasticity↗

Flutter-Constrained Optimization with the Linearized Frequency-Domain Approach

Due to the high computational cost associated with unsteady aeroelastic analysis, state-of-the-art aeroelastic optimizations based on computational fluid dynamics typically ignore critical constraints like flutter and aeroelastic gust response. The linearized frequency-domain method offers an approach for adding high-fidelity flutter constraints to multidisciplinary optimizations at relatively low cost compared to other unsteady computational fluid dynamics methods. In recent work, sensitivities have been implemented for the linearized frequency-domain method in FUN3D. In this work, the linearized frequency-domain method and associated sensitivities are applied to gradient-based aeroelastic optimization with flutter constraints based on computational fluid dynamics. An overview of the flutter constraint formulation and implementation is provided, and then two optimization problems are presented. The first optimization increases the flutter speed of a pitch and plunge airfoil at transonic conditions using the minimal amount of geometric changes. The second optimization minimizes the mass of the AGARD 445.6 wing subject to a flutter constraint.

Aeroelasticity↗

Stochastic Simulations and Sensitivity Analysis of Plasma Flow

For complex physical systems with large number of random inputs, it will be very expensive to perform stochastic simulations for all of the random inputs. Stochastic sensitivity analysis is introduced in this paper to rank the significance of random inputs, provide information on which random input has more influence on the system outputs and the coupling or interaction effect among different random inputs. There are two types of numerical methods in stochastic sensitivity analysis: local and global methods. The local approach, which relies on a partial derivative of output with respect to parameters, is used to measure the sensitivity around a local operating point. When the system has strong nonlinearities and parameters fluctuate within a wide range from their nominal values, the local sensitivity does not provide full information to the system operators. On the other side, the global approach examines the sensitivity from the entire range of the parameter variations. The global screening methods, based on One-At-a-Time (OAT) perturbation of parameters, rank the significant parameters and identify their interaction among a large number of parameters. Several screening methods have been proposed in literature, i.e., the Morris method, Cotter's method, factorial experimentation, and iterated fractional factorial design. In this paper, the Morris method, Monte Carlo sampling method, Quasi-Monte Carlo method and collocation method based on sparse grids are studied. Additionally, two MHD examples are presented to demonstrate the capability and efficiency of the stochastic sensitivity analysis, which can be used as a pre-screening technique for reducing the dimensionality and hence the cost in stochastic simulations.

30 DIRECT ENERGY CONVERSION↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GEAR-MC and Differential-Operator Methods Applied to Electron-Photon Transport in the Integrated TIGER Series

The sensitivity analysis algorithms that have been developed by the radiation transport community in multiple neutron transport codes, such as MCNP and SCALE, are extensively used by fields such as the nuclear criticality community. However, these techniques have seldom been considered for electron transport applications. In the past, the differential-operator method with the single scatter capability has been implemented in Sandia National Laboratories’ Integrated TIGER Series (ITS) coupled electron-photon transport code. This work is meant to extend the available sensitivity estimation techniques in ITS by implementing an adjoint-based sensitivity method, GEAR-MC, to strengthen its sensitivity analysis capabilities. To ensure the accuracy of this method being extended to coupled electron-photon transport, it is compared against the central-difference and differential-operator methodologies to estimate sensitivity coefficients for an experiment performed by McLaughlin and Hussman. Energy deposition sensitivities were calculated using all three methods, and the comparison between them has provided confidence in the accuracy of the newly implemented method. Unlike the current implementation of the differential-operator method in ITS, the GEAR-MC method was implemented with the option to calculate the energy-dependent energy deposition sensitivities, which are the sensitivity coefficients for energy deposition tallies to energy-dependent cross sections. The energy-dependent cross sections could be the cross sections for the material, elements in the material, or reactions of interest for the element. Further, these sensitivities were compared to the energy-integrated sensitivity coefficients and exhibited a maximum percentage difference of 2.15%.

42 ENGINEERING↗

Selected Uses of TSUNAMI in Critical Experiment Design and Analysis

Validation in criticality safety is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 and enable investigation of the parameters at which such a critical condition is achieved. For the critical experiments used in a validation to capture the biases of the materials and neutron energy spectra of interest, those materials must be included in the experiment such that they influence k eff or another observable parameter with statistical significance. This paper discusses the use of sensitivity uncertainty (S/U) methods to develop critical experiments for various purposes. S/U techniques are useful for understanding the underlying components of nuclear data which affect the k eff or another parameter of a given configuration. S/U calculations are most commonly used to compare existing experiments to applications of interest; however, S/U techniques can also be used to identify, optimize, or assess features of proposed experiments so that they can better test specific portions of nuclear data or match an application of interest. The S/U techniques discussed here are from the TSUNAMI code system. The two primary codes discussed in this work are TSUNAMI-3D, which implements the KENO criticality code to calculate the sensitivity of k eff to nuclear data, and TSAR, which calculates the sensitivity of a reactivity difference between two configurations based on their TSUNAMI-3D generated sensitivity profiles. The methods used in these tools are discussed in more detail in the SCALE manual. This paper is one of a series on the development and use of TSUNAMI tools. The other papers address development of TSUNAMI methods and a review of TSUNAMI applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗