Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Highly multiplexible thermal kinetic inductance detectors for x-ray imaging spectroscopy

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present a TKID prototype, which is able to achieve an energy resolution of 75 eV at 5.9 keV, even though its general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing, and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations, we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential beneficial effects of electron-hole plasmas created in silicon sensors by XFEL-like high intensity pulses for detector development

There is a compelling need for a high frame rate imaging detector with a wide dynamic range, from single x-rays/pixel/pulse to >10{sup 6} x-rays/pixel/pulse, that is capable of operating at both x-ray free electron laser (XFEL) and 3rd generation sources with sustained fluxes of > 10{sup 11} x-rays/pixel/s [1, 2, 3]. We propose to meet these requirements with the High Dynamic Range Pixel Array Detector (HDR-PAD) by (a) increasing the speed of charge removal strategies [4], (b) increasing integrator range by implementing adaptive gain [5], and (c) exploiting the extended charge collection times of electron-hole pair plasma clouds that form when a sufficiently large number of x-rays are absorbed in a detector sensor in a short period of time [6]. We have developed a measurement platform similar to the one used in [6] to study the effects of high electron-hole densities in silicon sensors using optical lasers to emulate the conditions found at XFELs. Characterizations of the employed tunable wavelength laser with picosecond pulse duration have shown Gaussian focal spots sizes of 6 ± 1 µm rms over the relevant spectrum and 2 to 3 orders of magnitude increase in available intensity compared to previous measurements presented in [6]. Results from measurements on a typical pixelated silicon diode intended for use with the HDR-PAD (150 µm pixel size, 500 µm thick sensor) are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of readout electronics for POLARBEAR-2 cosmic microwave background experiment

The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation cosmic microwave background (CMB) experiment, Polarbear-2, having 7588 TES bolometers. To enable the large arrays, we have been developing a readout system with a multiplexing factor of 40 in the frequency domain. Extending that architecture to 40 bolometers requires an increase in the bandwidth of the SQUID electronics, above 4 MHz. This paper focuses on cryogenic readout and shows how it affects cross talk and the responsivity of the TES bolometers. A series resistance, such as equivalent series resistance of capacitors for LC filters, leads to non-linear response of the bolometers. A wiring inductance modulates a voltage across the bolometers and causes cross talk. They should be controlled well to reduce systematic errors in CMB observations. As a result, we have been developing a cryogenic readout with a low series impedance and have tuned bolometers in the middle of their transition at a high frequency (>3 MHz).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The GlueX Start Counter Detector

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscale-Resolution Thermal Mapping Using a Flexible Platform of Patterned Quantum Sensors

Here, temperature sensors with micro- and nanoscale spatial resolution have long been explored for their potential to investigate the details of physical systems at an unprecedented scale. In particular, the rapid miniaturization of transistor technology, with its associated steep boost in power density, calls for sensors that accurately monitor heating distributions. Here, we report on a simple and scalable fabrication approach, based on directed self-assembly and transfer-printing techniques, to constructing arrays of nanodiamonds containing temperature-sensitive fluorescent spin defects. The nano-particles are embedded within a low-thermal-conductivity matrix that allows for repeated use on a wide range of systems with minimal spurious effects. Additionally, we demonstrate access to a wide spectrum of array parameters ranging from sparser single-particle arrays, with the potential for quantum computing applications, to denser devices with 98 ± 0.8% yield and stronger photoluminescence signals, ideal for temperature measurements. With these, we experimentally reconstruct the temperature map of an operating coplanar waveguide to confirm the accuracy of these platforms.

47 OTHER INSTRUMENTATION↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

The 先生 (SENSEI†) Experiment: sub-GeV dark matter searches with skipper-CCD

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The SENSEI Experiment: sub-GeV dark matter searches with skipper-CCDs

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.

60 APPLIED LIFE SCIENCES↗

An in-depth field validation of “DUSST”: A novel low-maintenance soiling measurement device

This study presents indoor and field validation results for two versions of the “DUSST” optical soiling sensor, intended to be a low-cost and low-maintenance device for measuring photovoltaic soiling losses. Indoor testing covers irradiance calibration and temperature dependencies, which are necessary to achieve high accuracy, low uncertainty field measurements. Field testing includes an array of different environments including Saudi Arabia, California, Utah, and Colorado. DUSST versions include a configuration with a 530-nm light emitting diode (LED) (discussed in previous work) and a unit with seven white LEDs and a polycarbonate collimating optic. The new design increases light intensity fivefold and demonstrates a single linear calibration coefficient is effective to measure soiling losses as high as 75%. Field data from Utah and California demonstrate that daily soiling loss measurements and soiling rate calculations closely match both reference cell and full-size module measurements of soiling losses and soiling rates. Corrective methods employed on the Utah DUSST sensor suggest that it is possible to achieve measurement errors as low as ±0.1% at two standard deviations. Field data from both Colorado and Saudi Arabia demonstrate that LED lens soiling can occur and that further design optimizations are needed. The lesson learned from all the field deployment locations suggests directions for future design improvements.

14 SOLAR ENERGY↗

Event Location using Arrival Times from Seismic and Acoustic Phenomena

Accurately locating seismoacoustic sources with geophysical observations helps to monitor natural and anthropogenic phenomena. Sparsely deployed infrasound arrays can readily locate large sources thousands of kms away, but small events typically produce signals observable at only local to regional distances. At such distances, accurate location efforts rely on observations across smaller regional or temporary deployments which often consist of single-channel infrasound sensors that cannot record direction of arrival. Event locations can also be aided by inclusion of ground coupled airwaves (GCA). This study demonstrates how we can robustly locate a catalog of seismoacoustic events using infrasound, GCA, and seismic arrival times at local to near-regional distances. We employ a probabilistic location framework using simplified forward models. Our results indicate that both single-channel infrasound and GCA arrival times can provide accurate estimates of event location in the absence of array-based observations even when using simple models. However, one must carefully choose model uncertainty bounds to avoid underestimation of confidence intervals.

58 GEOSCIENCES↗

Data acquisition and analysis of the UNCOSS underwater explosive neutron sensor

The purpose of the FP7 UNCOSS project (Underwater Coastal Sea Surveyor, http://www.uncoss-project.org) is to develop a neutron-based underwater explosive sensor to detect unexploded ordnance lying on the sea bottom. The Associated Particle Technique is used to focus the inspection on a suspicious object located by optical and electromagnetic sensors and to determine if there is an explosive charge inside. This paper presents the data acquisition electronics and data analysis software which have been developed for this project. A field programmable gate array that digitizes and processes the signal allows to perform precise time-of-flight and gamma-ray energy measurements. The gamma-ray spectra are unfolded into pure elemental count proportions, mainly C, N, O, Fe, Al, Si, and Ca. The C, N, and O count fractions are converted into chemical proportions, taking into account the gamma-ray production cross sections, as well as neutron and photon attenuation in the different shields between the ROV (Remotely Operated Vehicle) and the explosive, such as the explosive iron shell, seawater, and ROV envelop. A two-dimensional (2D) barycentric representation of the C, N, and O proportions is built from their chemical ratios, and a 2D likelihood map is built from the associated statistical and systematic uncertainties. The threat level is evaluated from the best matching materials of a database including explosives. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflective binary amplitude grating for soft x-ray shearing and Hartmann wavefront sensing

Here, we demonstrate a reflective wavefront sensor grating suitable for the characterization of high-quality x-ray beamlines and optical systems with high power densities. Operating at glancing incidence angles, the optical element is deeply etched with a two-level pattern of shearing interferometry gratings and Hartmann wavefront sensor grids. Transverse features block unwanted light, enabling binary amplitude in reflection with high pattern contrast. We present surface characterization and soft x-ray reflectometry of a prototype grating array to demonstrate function prior to wavefront measurement applications. A simulation of device performance is shown.

47 OTHER INSTRUMENTATION↗

Data Release Report Source Physics Experiments 5 and 6 (SPE-5 and SPE-6), Nevada National Security Site

The fifth Source Physics Experiment test (SPE-5) was conducted in Nevada on April 26, 2016, at 20:49:00 Coordinated Universal Time (UTC). The explosive source was 4,288.7 kilograms (kg) of polymer-bonded explosive (PBXN) –110, equivalent to 5,035 kg of trinitrotoluene (TNT) detonated at a depth of 76.5 meters (m). The sixth Source Physics Experiment test (SPE-6) was conducted in Nevada on October 12, 2016 at 18:36:00 UTC. The explosive source was 1,982.2 kg of PBXC-141, equivalent to 2,240.2 kg of TNT detonated at the depth of 31.4 m. Both tests were recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths ranging from 4 to 99 m below ground surface in boreholes positioned around the shot, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 400 kilometers. In addition, both explosions were recorded in a temporary array of 996 geophones arranged in a densely spaced grid pattern (“large N”). This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the fifth and sixth Source Physics Experiment tests and the various types of near-field and far-field data that are available.

58 GEOSCIENCES↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗