Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Techno-economic analysis of a conceptual biofuel production process from bioethylene produced by photosynthetic recombinant cyanobacteria

Ethylene is a petrochemical produced in large volumes worldwide. It serves as a building block for a wide variety of plastics, textiles, and chemicals, and can be converted into liquid transportation fuels. There is great interest in the development of technologies that produce ethylene from renewable resources, such as biologically derived CO 2 and biomass. One of the metabolic pathways used by microbes to produce ethylene is via an ethylene-forming enzyme (EFE). By expressing a bacterial EFE gene in a cyanobacterium, ethylene has been produced through photosynthetic carbon fixation. Here, we present a conceptual design and techno-economic analysis of a process of biofuel production based on the upgradation of ethylene generated by the recombinant cyanobacterium. This analysis focuses on potential near-term to long-term cost projections for the integrated process of renewable fuels derived from ethylene. The cost projections are important in showing the potential of this technology and determining research thrusts needed to reach target goals. The base case for this analysis is a midterm projection using tubular photobioreactors for cyanobacterial growth and ethylene production, cryogenic distillation for ethylene separation and purification, a two-step Ziegler oligomerization process with subsequent hydrotreatment and upgradation for fuel production, and a wastewater treatment process that utilizes anaerobic digestion of cyanobacterial biomass. The minimum fuel selling price (MFSP) for the midterm projection is 15.07 per gallon gasoline equivalent (GGE). Near-term and long-term projections are 28.66 per GGE and 5.36 per GGE, respectively. Single- and multi-point sensitivity analyses are conducted to determine the relative effect that chosen variables could have on the overall costs. This analysis identifies several key variables for improving the overall process economics and outlines strategies to guide future research directions. Finally, the productivity of ethylene has the largest effect on cost and is calculated based on a number of variables that are incorporated into this cost model (i.e., quantum requirement, photon transmission efficiency, and the percent of energy going to either ethylene or cyanobacterial biomass production).

09 BIOMASS FUELS↗

SENSITIVITY OF STACKED IMAGING DETECTORS TO HARD X-RAY POLARIZATION

The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions dedicated to spectroscopy and imaging at energies >10 keV, e.g., Astro-H and NuSTAR. Nevertheless, our understanding of the hard X-ray sky would greatly benefit from carrying out contemporaneous polarimetric measurements, because the study of hard spectral tails and of polarized emission are often two complementary diagnostics of the same non-thermal and acceleration processes. At energies above a few tens of keV, the preferred technique to detect polarization involves the determination of photon directions after a Compton scattering. Many authors have asserted that stacked detectors with imaging capabilities can be exploited for this purpose. If it is possible to discriminate those events which initially interact in the first detector by Compton scattering and are subsequently absorbed by the second layer, then the direction of scattering is singled out from the hit pixels in the two detectors. In this paper, we give the first detailed discussion of the sensitivity of such a generic design to the X-ray polarization. The efficiency and the modulation factor are calculated analytically from the geometry of the instruments and then compared with the performance as derived by means of Geant4 Monte Carlo simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer↗

Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance

Often only a single physical process or component is investigated in the simulation of radiation detector systems. The results are then considered to be representative of what is expected in the correlating physical experiment. Although singular assessments may serve as a good estimate, the overall performance of a radiation detector system depends on several physical processes and the performance of all components within the system. Our Geant4-based multiphysics simulation toolkit couples radiation transport with optical photon processes, providing simulations of radiation detector systems components from the scintillator through the photocathode of the photodetector. Work to incorporate the back-end detector components, including the complete photodetector and subsequent electronics (e.g., amplifiers, digitizers), is underway. Geant4 is used to model the radiation transport and optical photon processes that occur in the front-end detector system components when exposed to a chosen source. These components include the scintillator, detector housing, optical coupling to the photodetector, and photocathode of the photodetector. Characteristics of several detector systems that have been studied include time response; pulse height spectra; number of photoelectrons per MeV; detector efficiency versus incident quanta energy; and effects on detector response due to change in geometries, materials, and reflectivity. Comparison of these characteristics by means of this toolkit enables the selection of the optimal individual components; thus, it is possible to specify the radiation detector system best suited to meet the requirements of any physical experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bringing weak transitions to light

Abstract Weak transitions between quantum states are of fundamental importance for a broad range of phenomena from analytical biochemistry to precision physics, but generally challenge experimental detection. Due to their small cross sections scaling with the absolute square of their transition matrix elements, spectroscopic measurements often fail in particular in the presence of competing background processes. Here we introduce a general concept to break this scaling law and enhance the transition probability by exploiting a stronger laser-coupled pathway to the same excited state. We demonstrate the concept experimentally by attosecond transient absorption spectroscopy in helium atoms. The quasi-forbidden transitions from the ground state 1s 2 to the weakly coupled doubly excited 2p3dandsp 2,4− states are boosted by an order of magnitude. Enhancing single-photon-suppressed transitions can find widespread applicability, from spectral diagnostics of complex molecules in life and chemical sciences to precision spectroscopy of weak transitions in metastable atomic nuclei in the search for new physics.

Science & Technology - Other Topics↗

Theory of x-ray absorption by laser-aligned symmetric-top molecules.

We devise a theory of x-ray absorption by symmetric-top molecules which are aligned by an intense optical laser. Initially, the density matrix of the system is composed of the electronic ground state of the molecules and a thermal ensemble of rigid-rotor eigenstates. We formulate equations of motion of the two-color (laser plus x rays) rotational-electronic problem. The interaction with the laser is assumed to be nonresonant; it is described by an electric dipole polarizability tensor. X-ray absorption is approximated as a one-photon process. It is shown that the equations can be separated such that the interaction with the laser can be treated independently of the x rays. The laser-only density matrix is propagated numerically. After each time step, the x-ray absorption is calculated. We apply our theory to study adiabatic alignment of bromine molecules (Br2). The required dynamic polarizabilities are determined using the ab initio linear response methods coupled-cluster singles (CCS), second-order approximate coupled-cluster singles and doubles (CC2), and coupled-cluster singles and doubles (CCSD). For the description of x-ray absorption on the {sigma}g1s-->{sigma}u4p resonance, a parameter-free two-level model is used for the electronic structure of the molecules. Our theory opens up novel perspectives for the quantum control of x-ray radiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Meaurement of the target single-spin asymmetry in quasi-elastic region from the reaction {sup 3}He{up_arrow}(e,e')

A measurement of the inclusive target single-spin asymmetry has been performed using the quasi-elastic {sup 3}He{up_arrow}(e,e') reaction with a vertically polarized {sup 3}He target at Q{sup 2} values of 0.13, 0.46 and 0.97 GeV{sup 2}. This asymmetry vanishes under the one photon exchange assumption. But the interference between two-photon exchange and one-photon exchange gives rise to an imaginary amplitude, so that a non-zero A{sub y} is allowed. The experiment, conducted in Hall A of Jefferson Laboratory in 2009, used two independent spectrometers to simultaneously measure the target single-spin asymmetry. Using the effective polarization approximation, the neutron single-spin asymmetries were extracted from the measured {sup 3}He asymmetries. The measurement is to establish a non-vanishing A{sub y}. Non-zero asymmetries were observed at all Q{sup 2} points, and the overall precision is an order of magnitude improved over the existing proton data. The data provide new constraints on Generalized Parton Distribution (GPD) models and new information on the dynamics of the two-photon exchange process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Canted Undulator Upgrade for GeoSoilEnviroCARS Sector 13 at the Advanced Photon Source

Support for the beamline component of the canted undulator upgrade of Sector 13 (GeoSoilEnviroCARS; managed and operated by the University of Chicago) at the Advanced Photon Source (APS; Argonne National Laboratory) was received from three agencies (equally divided): NASA-SRLIDAP (now LARS), NSF-EAR-IF (ARRA) and DOE-Single Investigator Small Group (SISGR). The associated accelerator components (undulators, canted front end) were provided by the APS using DOE-ARRA funding. The intellectual merit of the research enabled by the upgrade lies in advancing our knowledge of the composition, structure and properties of earth materials; the processes they control; and the processes that produce them. The upgrade will facilitate scientific advances in the following areas: high pressure mineral physics and chemistry, non-crystalline and nano-crystalline materials at high pressure, chemistry of hydrothermal fluids, reactions at mineral-water interfaces, biogeochemistry, oxidation states of magmas, flow dynamics of fluids and solids, and cosmochemistry. The upgrade, allowing the microprobe to operate 100% of the time and the high pressure and surface scattering and spectroscopy instruments to receive beam time increases, will facilitate much more efficient use of the substantial investment in these instruments. The broad scientific community will benefit by the increase in the number of scientists who conduct cutting-edge research at GSECARS. The user program in stations 13ID-C (interface scattering) and 13ID-D (laser heated diamond anvil cell and large volume press) recommenced in June 2012. The operation of the 13ID-E microprobe station began in the Fall 2012 cycle (Oct.-Dec 2012). The upgraded canted beamlines double the amount of undulator beam time at Sector 13 and provide new capabilities including extended operations of the X-ray microprobe down to the sulfur K edge and enhanced brightness at high energy. The availability of the upgraded beamlines will advance the research being conducted at Sector 13.

47 OTHER INSTRUMENTATION↗

New physical processes for extracting GPDs with a better sensitivity to partonic structure

We introduce a new type of exclusive processes for a better study of generalized parton distributions (GPDs), which we refer to as single-diffractive hard exclusive processes (SDHEPs). We advocate a two-stage framework for picturing SDHEPs based on the separation of scales, which gives a clear description both kinematically and dynamically. We examine the sensitivity of the SDHEP to the parton momentum fraction x -dependence of GPDs, and demonstrate it quantitatively with two specific processes that can be readily measured at J-PARC or AMBER using a pion beam and at JLab using a photon beam, respectively. Both processes are capable of providing enhanced sensitivity to the x -dependence, overcoming the problem of shadow GPDs, and disentangling different types of GPDs with various spin asymmetries.

Qiu, Jianwei↗

Thermophotovoltaic power conversion systems: Current performance and future potential

Thermophotovoltaic (TPV) systems offer a unique, solid-state approach to converting heat into electricity based on thermal radiation. TPV is particularly suitable for certain classes of power generation applications that are not well served by standard engines, such as long, remote missions where repairs are difficult, and portable generation where space and weight are at a premium. While standard thermophotovoltaics are limited in their conversion efficiency, photonic crystals can improve performance by an order of magnitude for a number of systems. While there are many potential applications, two exemplary systems are discussed: TPV μreactors for portable power generation in a mm-scale form factor, and solar TPV for long-term off-grid power generation from sunlight. In both cases, photonic crystals can enable potential performance exceeding that of many other well-known technologies, such as single-junction photovoltaics.

14 SOLAR ENERGY↗

Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit

Purpose: It is a known fact that Monte Carlo simulations of radiation transport are computationally intensive and may require long computing times. The authors introduce a new paradigm for the acceleration of Monte Carlo simulations: The use of a graphics processing unit (GPU) as the main computing device instead of a central processing unit (CPU). Methods: A GPU-based Monte Carlo code that simulates photon transport in a voxelized geometry with the accurate physics models from PENELOPE has been developed using the CUDA programming model (NVIDIA Corporation, Santa Clara, CA). Results: An outline of the new code and a sample x-ray imaging simulation with an anthropomorphic phantom are presented. A remarkable 27-fold speed up factor was obtained using a GPU compared to a single core CPU. Conclusions: The reported results show that GPUs are currently a good alternative to CPUs for the simulation of radiation transport. Since the performance of GPUs is currently increasing at a faster pace than that of CPUs, the advantages of GPU-based software are likely to be more pronounced in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

Microwave-assisted hydrothermally grown epitaxial ZnO films on Left-Pointing-Angle-Bracket 1 1 1 Right-Pointing-Angle-Bracket MgAl{sub 2}O{sub 4} substrate

In this report, epitaxial ZnO films were grown on Left-Pointing-Angle-Bracket 1 1 1 Right-Pointing-Angle-Bracket MgAl{sub 2}O{sub 4} single crystal substrates using Microwave Assisted Hydrothermal (MAH) method with microwave radiation heating (2.45 GHz) at 90 Degree-Sign C in a short time (within 15 min). Scanning electron microscopy confirms that these films possess smooth surface morphology with fully coalesced grains. In addition, photoluminescence (PL) measurements exhibit strong ultraviolet emission at room temperature, indicating potential applications for short-wave light-emitting photonic devices. The PL properties were improved by a thermal annealing process without generating structural defects. Hall measurements after thermal treatment show the carrier concentration to be of the order of 10{sup 19} cm{sup -3} which is comparable to those grown by conventional solution methods. The MAH method will offer a rapid route to synthesize epitaxial ZnO films with good optical and electrical properties for various applications. - Graphical abstract: FESEM images showing the morphology and cross sectional view of ZnO films grown using microwave assisted hydrothermal method at 90 Degree-Sign C for 30 min. Highlights: Black-Right-Pointing-Pointer Microwave Assisted Hydrothermal (MAH) method was introduced to synthesize epitaxial ZnO films. Black-Right-Pointing-Pointer The films possess smooth surface morphology, fully coalesced grains with high optical properties. Black-Right-Pointing-Pointer It exhibit good electrical properties (carrier concentration 10{sup 19} cm{sup -3}, mobility 19 cm{sup 2}/Vs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the physics potential to study the gluon content of proton and deuteron at NICA SPD

The Spin Physics Detector (SPD) is a future multipurpose experiment foreseen to run at the NICA collider, which is currently under construction at the Joint Institute for Nuclear Research (JINR, Dubna, Russia). The physics program of the experiment is based on collisions of longitudinally and transversely polarized protons and deuterons at √s up to 27 GeV and luminosity up to 10 32 cm –2 s –1 . SPD will operate as a universal facility for the comprehensive study of the unpolarized and polarized gluon content of the nucleon, using complementary probes such as: charmonia, open-charm, and prompt-photon production processes. Furthermore, the aim of this work is to provide a thorough review of the physics objectives that can potentially be addressed at SPD, underlining related theoretical aspects and discussing relevant experimental results when available. Among different pertinent phenomena particular attention is drawn to the study of the gluon helicity, gluon Sivers and Boer-Mulders functions in the nucleon, as well as the gluon transversity distribution in the deuteron, via the measurement of single and double spin asymmetries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the single polarization observables I{sup c} and I{sup s} in {pi}{sup 0{eta}} photoproduction

Meson photoproduction off the nucleon is a key tool in order to understand the structure of baryons and their excitation spectrum. Especially in the regime of high-lying resonances the photoproduction of multi-meson final states is of increasing importance, given that the cross sections for such processes exceed those for single-meson production. Additionally it gives a handle on sequential decays of such resonances via e.g. the {Delta}(1232) or the S{sub 11}(1535) in the intermediate state. For a complete understanding of the processes involved, the measurement not only of unpolarized cross sections but also of polarization observables is mandatory. With the Crystal Barrel/TAPS experiment, located at the ELSA accelerator facility in Bonn, it was possible to determine such observables using a linearly polarized photon beam impinging on a liquid hydrogen target. The beam asymmetries I{sup c} and I{sup s} are presented for the reaction gp {gamma}{sup {yields}p{yields}}p{pi}{sup 0{eta}}. The latter is a feature exclusive to the acoplanar kinematics of multi-meson final states and has been measured for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A front-end readout Detector Board for the OpenPET electronics system

Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.

47 OTHER INSTRUMENTATION↗

Dispersion-engineered χ(2) nanophotonics: a flexible tool for nonclassical light

Abstract This article reviews recent progress in quasi-phasematched χ ( 2 ) nonlinear nanophotonics, with a particular focus on dispersion-engineered nonlinear interactions. Throughout this article, we establish design rules for the bandwidth and interaction lengths of various nonlinear processes, and provide examples for how these processes can be engineered in nanophotonic devices. In particular, we apply these rules towards the design of sources of non-classical light and show that dispersion-engineered devices can outperform their conventional counterparts. Examples include ultra-broadband optical parametric amplification as a resource for measurement-based quantum computation, dispersion-engineered spontaneous parametric downconversion as a source of separable biphotons, and synchronously pumped nonlinear resonators as a potential route towards single-photon nonlinearities.

Jankowski, Marc (ORCID:0000000318457415)↗

Multichannel photoelectron phase lag across atomic barium autoionizing resonances

Phase lag associated with coherent control where an excited system decays into more than one product channel has been subjected to numerous investigations. Although previous theoretical studies have treated the phase lag across resonances in model calculations, quantitative agreement has never been achieved between the theoretical model and an experimental measurement of the phase lag from the ω-2ω ionization of atomic barium. Yamazaki and Elliot, Phys. Rev. Lett. 98, 053001 (2007); Phys. Rev. A 76, 053401 (2007), suggesting that a toy model with phenomenological parameters is inadequate to describe the observed phase lag behavior. Here the phase lag is treated quantitatively in a multichannel coupling formulation, and our calculation based on a multichannel quantum defect and R-matrix treatment achieves good agreement with the experimental observations. Our treatment also develops formulas to describe the effects of hyperfine depolarization on multiphoton ionization processes. Moreover, we identify resonances between Ba + 5d 3/2 and 5d 5/2 thresholds that have apparently never been experimentally observed and classified.

74 ATOMIC AND MOLECULAR PHYSICS↗