Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Low Size, Weight, and Power Neuromorphic Computing to Improve Combustion Engine Efficiency

Neuromorphic computing offers one path forward for AI at the edge. However, accessing and effectively utilizing a neuromorphic hardware platform is non-trivial. In this work, we present a complete pipeline for neuromorphic computing at the edge, including a small, inexpensive, low-power, FPGA-based neuromorphic hardware platform, a training algorithm for designing spiking neural networks for neuromorphic hardware, and a software framework for connecting those components. We demonstrate this pipeline on a real-world application, engine control for a spark-ignition internal combustion engine. We illustrate how we connect engine simulations with neuromorphic hardware simulations and training software to produce hardware-compatible spiking neural networks that perform engine control to improve fuel efficiency. We present initial results on the performance of these spiking neural networks and illustrate that they outperform open-loop engine control. We also give size, weight, and power estimates for a deployed solution of this type.

Schuman, Catherine↗

An Interactive Spectral Analysis Tool for Chemical Identification and Quantification of Gas-Phase Species in Complex Spectra

A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm –1 ) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.

Thompson, Christopher J.↗

Using PyBioNetFit to leverage qualitative and quantitative data in biological model parameterization and uncertainty quantification

Data generated in studies of cellular regulatory systems are often qualitative. For example, measurements of signaling readouts in the presence and absence of mutations may reveal a rank ordering of responses across conditions but not the precise extents of mutation-induced differences. Qualitative data are often ignored by mathematical modelers or are considered in an ad hoc manner, as in the study of Kocieniewski and Lipniacki (2013) [Phys Biol 10: 035006], which was focused on the roles of MEK isoforms in ERK activation. In this earlier study, model parameter values were tuned manually to obtain consistency with a combination of qualitative and quantitative data. This approach is not reproducible, nor does it provide insights into parametric or prediction uncertainties. Here, starting from the same data and the same ordinary differential equation (ODE) model structure, we generate formalized statements of qualitative observations, making these observations more reusable, and we improve the model parameterization procedure by applying a systematic and automated approach enabled by the software package PyBioNetFit. We also demonstrate uncertainty quantification (UQ), which was absent in the original study. Our results show that PyBioNetFit enables qualitative data to be leveraged, together with quantitative data, in parameterization of systems biology models and facilitates UQ. These capabilities are important for reliable estimation of model parameters and model analyses in studies of cellular regulatory systems and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

Computational study of critical mass curves for various ratios of {sup 238}Pu to {sup 239}Pu

A MCNP study for a water-reflected sphere of plutonium metal water pseudo-solution was performed for a various ratios of {sup 238}Pu to {sup 239}Pu to develop minimum critical mass curves. The {sup 238}Pu atom percent (at. %) was varied from 35 to 100 percent. It was demonstrated that at {sup 238}Pu ratios of ≥ 65 at. % the high absorption cross section of {sup 238}Pu in the thermal energy region dominates the system reactivity for water moderated systems resulting in a minimum critical mass in the metal rather than solution regime. However, due to the lack of available benchmark experiments to validated use of the {sup 238}Pu cross-section data for quantities above gram-level, the models fell outside the area of applicability (AOA) of the Los Alamos National Laboratory's (LANL) Nuclear Criticality Safety Division's (NCSD) MCNP validation report. An additional of margin of subcriticality (MOS) is needed for {sup 238}Pu systems. This additional MOS will be dependent on the amount and significance of the {sup 238}Pu, which varies in the MCNP study. Whisper is a computational software package designed to assist with validation studies for MCNP. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application model. Therefore, Whisper 1.0.0 was used on the curve minima in the solution regime for the 65 at. % {sup 238}Pu curve to estimate an appropriate additional margin of subcriticality and create a subcritical curve based on the suggested upper subcritical limits (USL)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-I-37: How Fat Distribution and Table Height Affect Estimates of Patient Size in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and hence CTDIvol and SSDE. Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). This study sought to determine if patient size estimates made from localizer scans is affected by variations in fat distribution, specifically when the widest part of the patient is not at the geometric center of the patient. Methods: Lipid gel bolus material was wrapped around an anthropomorphic phantom to simulate two different body mass distributions. The first represented a patient with fairly rigid fat and had a generally oval shape. The second was bell-shaped, representing corpulent patients more susceptible to gravity’s lustful tug. Each phantom configuration was imaged using an AP localizer and then a PA localizer. This was repeated at various scanner table heights. The width of the phantom was measured from the localizer and diagnostic images using in-house software. Results: 1) The projected phantom width varied up to 39% as table height changed.2) At some table heights, the width of the phantom, designed to represent larger patients, exceeded the localizer field of view, resulting in an underestimation of the phantom width.3) The oval-shaped phantom approached a normalized phantom width of 1 at a table height several centimeters lower (AP localizer) or higher (PA localizer) than did the bell-shaped phantom. Conclusion: Accurate estimation of patient size from localizer scans is dependent on patient positioning with respect to scanner isocenter and is limited in large patients. Further, patient size is more accurately measured on projection images if the widest part of the patient, rather than the geometric center of the patient, is positioned at scanner isocenter.

60 APPLIED LIFE SCIENCES↗

DMLC tracking and gating can improve dose coverage for prostate VMAT

Purpose: To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. Methods: A dose reconstruction method was used to retrospectively assess the dose distributions delivered without motion correction during volumetric modulated arc therapy fractions for 20 fractions of five prostate cancer patients who received conventionally fractionated radiotherapy. These delivered dose distributions were compared with the dose distributions which would have been delivered had DMLC tracking or gating motion correction strategies been implemented. The delivered dose distributions were constructed by incorporating the observed prostate motion with the patient's original treatment plan to simulate the treatment delivery. The DMLC tracking dose distributions were constructed using the same dose reconstruction method with the addition of MLC positions from Linac log files obtained during DMLC tracking simulations with the observed prostate motions input to the DMLC tracking software. The gating dose distributions were constructed by altering the prostate motion to simulate the application of a gating threshold of 3 mm for 5 s. Results: The delivered dose distributions showed that dosimetric effects of intrafraction prostate motion could be substantial for some fractions, with an estimated dose decrease of more than 19% and 34% from the planned CTVD{sub 99%} and PTV D{sub 95%} values, respectively, for one fraction. Evaluation of dose distributions for DMLC tracking and gating deliveries showed that both interventions were effective in improving the CTV D{sub 99%} for all of the selected fractions to within 4% of planned value for all fractions. For the delivered dose distributions the difference in rectum V{sub 65%} for the individual fractions from planned ranged from −44% to 101% and for the bladder V{sub 65%} the range was −61% to 26% from planned. The application of tracking decreased the maximum rectum and bladder V{sub 65%} difference to 6% and 4%, respectively. Conclusions: For the first time, the dosimetric impact of DMLC tracking and gating to account for intrafraction motion during prostate radiotherapy has been assessed and compared with no motion correction. Without motion correction intrafraction prostate motion can result in a significant decrease in target dose coverage for a small number of individual fractions. This is unlikely to effect the overall treatment for most patients undergoing conventionally fractionated treatments. Both DMLC tracking and gating demonstrate dose distributions for all assessed fractions that are robust to intrafraction motion.

60 APPLIED LIFE SCIENCES↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of differences in calculated and actual measured skin doses to canine limbs during stereotactic radiosurgery using Gafchromic film

Accurate calculation of absorbed dose to the skin, especially the superficial and radiosensitive basal cell layer, is difficult for many reasons including, but not limited to, the build-up effect of megavoltage photons, tangential beam effects, mixed energy scatter from support devices, and dose interpolation caused by a finite resolution calculation matrix. Stereotactic body radiotherapy (SBRT) has been developed as an alternative limb salvage treatment option at Colorado State University Veterinary Teaching Hospital for dogs with extremity bone tumors. Optimal dose delivery to the tumor during SBRT treatment can be limited by uncertainty in skin dose calculation. The aim of this study was to characterize the difference between measured and calculated radiation dose by the Varian Eclipse (Varian Medical Systems, Palo Alto, CA) AAA treatment planning algorithm (for 1-mm, 2-mm, and 5-mm calculation voxel dimensions) as a function of distance from the skin surface. The study used Gafchromic EBT film (International Specialty Products, Wayne, NJ), FilmQA analysis software, a limb phantom constructed from plastic water Trade-Mark-Sign (fluke Biomedical, Everett, WA) and a canine cadaver forelimb. The limb phantom was exposed to 6-MV treatments consisting of a single-beam, a pair of parallel opposed beams, and a 7-beam coplanar treatment plan. The canine forelimb was exposed to the 7-beam coplanar plan. Radiation dose to the forelimb skin at the surface and at depths of 1.65 mm and 1.35 mm below the skin surface were also measured with the Gafchromic film. The calculation algorithm estimated the dose well at depths beyond buildup for all calculation voxel sizes. The calculation algorithm underestimated the dose in portions of the buildup region of tissue for all comparisons, with the most significant differences observed in the 5-mm calculation voxel and the least difference in the 1-mm voxel. Results indicate a significant difference between measured and calculated data extending to average depths of 2.5 mm, 3.4 mm, and 10 mm for the 1-mm, 2-mm, and 5-mm dimension calculation matrices, respectively. These results emphasize the importance of selecting as small a treatment planning software calculation matrix dimension as is practically possible and of taking a conservative approach for skin treatment planning objectives. One suggested conservative approach is accomplished by defining the skin organ as the outermost 2-3 mm of the body such that the high dose tail of the skin organ dose-volume histogram curve represents dose on the deep side of the skin where the algorithm is more accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling the small-scale deposition of snow onto structured Arctic sea ice during a MOSAiC storm using snowBedFoam 1.0.

The remoteness and extreme conditions of the Arctic make it a very difficult environment to investigate. In these polar regions covered by sea ice, the wind is relatively strong due to the absence of obstructions and redistributes a large part of the deposited snow mass, which complicates estimates for precipitation hardly distinguishable from blowing or drifting snow. Moreover, the snow mass balance in the sea ice system is still poorly understood, notably due to the complex structure of its surface. Quantitatively assessing the snow distribution on sea ice and its connection to the sea ice surface features is an important step to remove the snow mass balance uncertainties (i.e., snow transport contribution) in the Arctic environment. In this work we introduce snowBedFoam 1.0., a physics-based snow transport model implemented in the open-source fluid dynamics software OpenFOAM. We combine the numerical simulations with terrestrial laser scan observations of surface dynamics to simulate snow deposition in a MOSAiC (Multidisciplinary Drifting Observatory for the Study of Arctic Climate) sea ice domain with a complicated structure typical for pressure ridges. The results demonstrate that a large fraction of snow accumulates in their vicinity, which compares favorably against scanner measurements. However, the approximations imposed by the numerical framework, together with potential measurement errors (precipitation), give rise to quantitative inaccuracies, which should be addressed in future work. The modeling of snow distribution on sea ice should help to better constrain precipitation estimates and more generally assess and predict snow and ice dynamics in the Arctic.

54 ENVIRONMENTAL SCIENCES↗

A Review of Finite Element Method Models for Nuclear Graphite Applications

Graphite components serve as structural support and as a neutron moderator in multiple nuclear power stations and is also a prospective material in Generation IV reactor concepts. The environment (e.g. high temperature and intense radiation) within a graphite core changes the geometry, microstructure and material properties of the graphite components, that could limit the lifetime (i.e. safe operation) of a reactor. Some of the assessments made for graphite reactor core components include Finite Element Method (FEM) simulations. These simulations are used to estimate the stress state and strain state and probability of failure of irradiated graphite components. FEM also forms part of the validation of measurements or as a complementary technique to experimental procedures in graphite research. A comprehensive overview of FEM methodologies is provided in this review, including: FEM software, basics steps to set up a FEM model, and analytical solutions used to validate simulations for this field of study. In conclusion, the objective of this paper is to inform researchers in the different available FEM techniques and tools used in the research of nuclear graphite.

42 ENGINEERING↗

The melting temperature of liquid water with the effective fragment potential

Direct simulation of the solid-liquid water interface with the effective fragment potential (EFP) via the constant enthalpy and pressure (NPH) ensemble was used to estimate the melting temperature (Tm) of ice-Ih. Initial configurations and velocities, taken from equilibrated constant pressure and temperature (NPT) simulations at T = 300 K, 350 K and 400 K, respectively, yielded corresponding Tm values of 378±16 K, 382±14 K and 384±15 K. These estimates are consistently higher than experiment, albeit to the same degree with previously reported estimates using density functional theory (DFT)-based Born-Oppenheimer simulations with the Becke-Lee-Yang-Parr functional plus dispersion corrections (BLYP-D). KRB was supported by a Computational Science Graduate Fellowship from the Department of Energy. MSG was supported by a U.S. National Science Foundation Software Infrastructure (SI2) grant (ACI – 1047772). SSX acknowledges support from the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle.

Brorsen, Kurt R.↗

Distributed data management on Belle II

The Belle II experiment started taking physics data in April 2018 with an estimated total volume of all files including raw events, Monte-Carlo and skim statistics of 340 petabytes expected by the end of operations in the late-2020s. Originally designed as a fully integrated component of the BelleDIRAC production system, the Belle II distributed data management (DDM) software needs to manage data across about 29 storage elements worldwide for a collaboration of nearly 1000 physicists. By late 2018, this software required significant performance improvements to meet the requirements of physics data taking and was seriously lacking in automation. Rucio, the DDM solution created by ATLAS, was an obvious alternative but required tight integration with BelleDIRAC and a seamless yet non-trivial migration. This contribution describes the work done on both DDM options, the current status of the software running successfully in production and the problems associated with trying to balance long-term operations cost against short term risk. .

97 MATHEMATICS AND COMPUTING↗

Application of the SEGUE Stellar Parameter Pipeline to LAMOST Stellar Spectra

We describe an application of the SEGUE Stellar Parameter Pipeline (SSPP) to medium-resolution stellar spectra obtained by the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST), in order to determine estimates of the stellar atmospheric parameters (T{sub eff}, log g, and [Fe/H]) and the abundance ratios ([α/Fe] and [C/Fe]). By performing a coordinate match with the LAMOST stellar database, we selected stars with LAMOST spectra in common with stars having available spectroscopy from the Apache Point Observatory Galactic Evolution Experiment (APOGEE), the RAdial Velocity Experiment (RAVE), and the Sloan Extension for Galactic Understanding and Exploration (SEGUE). We ran the selected LAMOST stellar spectra from each survey through SSPP, and compared the stellar parameters down to signal-to-noise ratio (S/N) of 10 and chemical abundances down to S/N = 20 derived by SSPP with those determined by the APOGEE, RAVE, and SEGUE software pipelines. Our results show that the derived stellar parameters generally agree quite well, even though there exist some small systematic offsets with small scatter in T{sub eff}, log g, and [Fe/H], due to the use of different temperature scales, abundance scales, and calibrations adopted by each survey. Comparison of the [α/Fe] determinations for LAMOST spectra suggests no sign of significant systematic offsets (<–0.04 dex), with a small scatter (<0.08 dex) relative to stars in common with APOGEE and SEGUE. The [C/Fe] estimates determined for the LAMOST spectra also exhibit good agreement, with a very small offset (∼0.01 dex) and scatter (∼0.12 dex) relative to the SEGUE stars, while there exists about a –0.19 dex offset, with a small scatter of ∼0.13 dex, for the APOGEE sample. Due to the existence of small offsets in the stellar parameters and abundances among difference data sets, optimal results when combining the different data sets will be obtained by removing the offsets. Once accomplished, the stellar parameters and chemical abundances estimated by SSPP from the LAMOST stellar spectra should provide a reliable database for studies of the Galactic disk and halo systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Plane-Parallel Electron Beam Propagation in Different Media by Numerical Simulation Methods

Simulation by the Monte Carlo method is widely used to calculate the character of ionizing radiation interaction with substance. A wide variety of programs based on the given method allows users to choose the most suitable package for solving computational problems. In turn, it is important to know exactly restrictions of numerical systems to avoid gross errors. Results of estimation of the feasibility of application of the program PCLab (Computer Laboratory, version 9.9) for numerical simulation of the electron energy distribution absorbed in beryllium, aluminum, gold, and water for industrial, research, and clinical beams are presented. The data obtained using programs ITS and Geant4 being the most popular software packages for solving the given problems and the program PCLab are presented in the graphic form. A comparison and an analysis of the results obtained demonstrate the feasibility of application of the program PCLab for simulation of the absorbed energy distribution and dose of electrons in various materials for energies in the range 1–20 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Low surface brightness galaxies selected from the 40% sky area of the ALFALFA H i Survey. I. Sample and statistical properties

The population of low surface brightness (LSB) galaxies, which are objects with central surface brightnesses at least one magnitude fainter than the night sky, is crucial for understanding the extremes of galactic formation and evolution of the universe. As LSB galaxies are mostly rich in gas (H i), the α.40 Sloan Digital Sky Survey (SDSS) Data Release 7 (DR7) sample is one of the best survey combinations to select a sample of them in the local universe. Since the sky backgrounds are systematically overestimated for galactic images by the SDSS photometric pipeline, particularly for luminous galaxies or galaxies with extended LSB outskirts, in this paper, we above all estimated the sky backgrounds of SDSS images accurately in both the g and r bands for each galaxy in the α.40 SDSS DR7 sample, using a precise method of sky subtraction. Once subtracting the sky background, we did surface photometry with the Kron elliptical aperture using the SExtractor software and fitted geometric parameters with an exponential profile model using the Galfit software for each galactic image in the α.40 SDSS DR7 sample. Based on the photometric and geometric results, we further calculated the B-band central surface brightness, μ{sub 0}(B), for each galaxy and ultimately defined a sample of LSB galaxies consisting of 1129 galaxies with μ{sub 0}(B) > 22.5 mag arcsec{sup −2} and the axis ratio b/a > 0.3 from the 12,423 α.40 SDSS DR7 galaxies. This H i-selected sample of LSB galaxies is a relatively unbiased sample of gas-rich and disk-dominated LSB galaxies, which is complete both in H i observation and the optical magnitude within the limit of the SDSS DR7 photometric survey. This LSB galactic sample spans from 22.5 to 28.3 in μ{sub 0}(B) with a fraction of 4% fainter than 25.0 mag arcsec{sup −2} in B-band central surface brightness and distributes from −27.0 to −12.3 mag in absolute magnitude in the B band (M(B)), including the 43 faintest galaxies (M(B) > −17.3 mag). This sample is a blue LSB galactic sample, of which 98% are bluer than 0.75 mag in B–V color. As for 21 cm H i properties, our LSB galactic sample has a median M{sub H i}/L{sub B} = 0.87, and a large portion (95%) has high mass of H i (M(H i) > 10{sup 7.7}M⊙), which supports galaxies in this LSB galactic sample being mostly gas-rich. Additionally, we statistically investigated the environment of our LSB galaxies and found that up to 92% of the total LSB galaxies have less than eight neighboring galaxies, which provides strong evidence that LSB galaxies prefer to reside in the low-density environment.

79 ASTRONOMY AND ASTROPHYSICS↗