Search NASA⌕ Search

SEARCH · Search NASA

Results for “software specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Large-Scale Additive Manufacturing of Silicon Carbide with Process Monitoring

This report summarizes new capabilities in additive manufacturing (AM) of large-scale silicon carbide (SiC) components under the Advanced Materials and Manufacturing Technologies (AMMT) program. SiC is a promising material that is being considered for many advanced reactor designs due to its high temperature strength, radiation tolerance, minimal neutron absorption, and oxidation resistance [1-8]. One of the primary limitations to using SiC as an in-core structural material is the inability to fabricate large SiC components with complex geometries. While under the former Transformational Challenge Reactor (TCR) program, ceramic AM systems at the Oak Ridge National Laboratory (ORNL) were limited in the quantity and overall size achievable for producing ceramic AM components. To address this, ORNL has improved its infrastructure for binder jet and chemical vapor infiltration (CVI) processes with cutting-edge equipment coming online in a newly renovated laboratory space capable of producing larger components and higher throughput without compromise on part size. This report details the laboratory renovation progress, focusing specifically on the DesktopMetal (formerly ExOne) X25Pro binder jet, a large scale CVI furnace, and the added functionality of a software tool called Peregrine for quality assurance and control purposes.

36 MATERIALS SCIENCE↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GeoChip 3.0: A High Throughput Tool for Analyzing Microbial Community, Composition, Structure, and Functional Activity

Microarray-based genomic technology has been widely used for microbial community analysis, and it is expected that microarray-based genomic technologies will revolutionize the analysis of microbial community structure, function and dynamics. A new generation of functional gene arrays (GeoChip 3.0) has been developed, with 27,812 probes covering 56,990 gene variants from 292 functional gene families involved in carbon, nitrogen, phosphorus and sulfur cycles, energy metabolism, antibiotic resistance, metal resistance, and organic contaminant degradation. Those probes were derived from 2,744, 140, and 262 species for bacteria, archaea, and fungi, respectively. GeoChip 3.0 has several other distinct features, such as a common oligo reference standard (CORS) for data normalization and comparison, a software package for data management and future updating, and the gyrB gene for phylogenetic analysis. Our computational evaluation of probe specificity indicated that all designed probes had a high specificity to their corresponding targets. Also, experimental analysis with synthesized oligonucleotides and genomic DNAs showed that only 0.0036percent-0.025percent false positive rates were observed, suggesting that the designed probes are highly specific under the experimental conditions examined. In addition, GeoChip 3.0 was applied to analyze soil microbial communities in a multifactor grassland ecosystem in Minnesota, USA, which demonstrated that the structure, composition, and potential activity of soil microbial communities significantly changed with the plant species diversity. All results indicate that GeoChip 3.0 is a high throughput powerful tool for studying microbial community functional structure, and linking microbial communities to ecosystem processes and functioning. To our knowledge, GeoChip 3.0 is the most comprehensive microarrays currently available for studying microbial communities associated with geobiochemical cycling, global climate change, bioenergy, agricuture, land use, ecosystem management, environmental cleanup and restoration, bioreactor systems, and human health.

54 ENVIRONMENTAL SCIENCES↗

Scientific and Computational Challenges of the Fusion Simulation Program (FSP)

This paper highlights the scientific and computational challenges facing the Fusion Simulation Program (FSP) a major national initiative in the United States with the primary objective being to enable scientific discovery of important new plasma phenomena with associated understanding that emerges only upon integration. This requires developing a predictive integrated simulation capability for magnetically-confined fusion plasmas that are properly validated against experiments in regimes relevant for producing practical fusion energy. It is expected to provide a suite of advanced modeling tools for reliably predicting fusion device behavior with comprehensive and targeted science-based simulations of nonlinearly-coupled phenomena in the core plasma, edge plasma, and wall region on time and space scales required for fusion energy production. As such, it will strive to embody the most current theoretical and experimental understanding of magnetic fusion plasmas and to provide a living framework for the simulation of such plasmas as the associated physics understanding continues to advance over the next several decades. Substantive progress on answering the outstanding scientific questions in the field will drive the FSP toward its ultimate goal of developing the ability to predict the behavior of plasma discharges in toroidal magnetic fusion devices with high physics fidelity on all relevant time and space scales. From a computational perspective, this will demand computing resources in the petascale range and beyond together with the associated multi-core algorithmic formulation needed to address burning plasma issues relevant to ITER - a multibillion dollar collaborative experiment involving seven international partners representing over half the world's population. Even more powerful exascale platforms will be needed to meet the future challenges of designing a demonstration fusion reactor (DEMO). Analogous to other major applied physics modeling projects (e.g., Climate Modeling), the FSP will need to develop software in close collaboration with computers scientists and applied mathematicians and validated against experimental data from tokamaks around the world. Specific examples of expected advances needed to enable such a comprehensive integrated modeling capability and possible "co-design" approaches will be discussed. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel Computing in SCALE

The SCALE computational architecture has remained basically the same since its inception 30 years ago, although constituent modules and capabilities have changed significantly. This SCALE concept was intended to provide a framework whereby independent codes can be linked to provide a more comprehensive capability than possible with the individual programs - allowing flexibility to address a wide variety of applications. However, the current system was designed originally for mainframe computers with a single CPU and with significantly less memory than today's personal computers. It has been recognized that the present SCALE computation system could be restructured to take advantage of modern hardware and software capabilities, while retaining many of the modular features of the present system. Preliminary work is being done to define specifications and capabilities for a more advanced computational architecture. This paper describes the state of current SCALE development activities and plans for future development. With the release of SCALE 6.1 in 2010, a new phase of evolutionary development will be available to SCALE users within the TRITON and NEWT modules. The SCALE (Standardized Computer Analyses for Licensing Evaluation) code system developed by Oak Ridge National Laboratory (ORNL) provides a comprehensive and integrated package of codes and nuclear data for a wide range of applications in criticality safety, reactor physics, shielding, isotopic depletion and decay, and sensitivity/uncertainty (S/U) analysis. Over the last three years, since the release of version 5.1 in 2006, several important new codes have been introduced within SCALE, and significant advances applied to existing codes. Many of these new features became available with the release of SCALE 6.0 in early 2009. However, beginning with SCALE 6.1, a first generation of parallel computing is being introduced. In addition to near-term improvements, a plan for longer term SCALE enhancement activities has been developed to provide an integrated framework for future methods development. Some of the major components of the SCALE parallel computing development plan are parallelization and multithreading of computationally intensive modules and redesign of the fundamental SCALE computational architecture.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Strengthening the Security of Operational Technology: Understanding Contemporary Bill of Materials

The evolution of cyber-physical infrastructure has made its security more challenging. The last few years have witnessed a convergence of hardware and software segments in various domains, including operational technology (OT) which is responsible for carrying out critical tasks such as monitoring and controlling power grids, nuclear plants, transportation, and emergency services. Both hardware and software encapsulate numerous open source and proprietary subcomponents, making it crucial for end-users to understand the composition of the products they are using. For example, wind turbines incorporate thousands of lines of code (software) used for the turbine's design, planning, operation, and analytics in addition to the numerous hardware subcomponents that construct it. Due to the highly complex nature of software and hardware, knowledge of the components and subcomponents is required to mitigate cyber vulnerabilities and defend against cyberattacks. There has also been a transformation from a traditional linear supply chain into a global, dynamic, diverse, and interconnected system. The digitization of the supply chain makes it easier to find and exploit vulnerabilities. Critical infrastructures (e.g., power grids, oil, natural gas, water, and wastewater) rely on OT to function, and if the OT is compromised, equipment damage and potential interruption of services could result. A significant security measure to protect OT systems from disruption is to develop a supply chain bill of materials (BoM) corresponding to the software and hardware used in OT, along with attestations amongst vendors and asset owners. A supply chain BoM is a proactive way to understand the inherent vulnerabilities in the system and mitigate them in advance of being exploited. BoMs bolster the trust placed in the digital infrastructure and enhance software supply chain security by sustaining the management of component obsolescence and compliance, along with the seclusion of unsafe segments of a specific product. Adopting BoM tools is becoming increasingly important across various government sectors, as evidenced by the recent U.S. executive order on cybersecurity (NIST 2021). This paper aims to classify BoMs based on structure, functionality, component type, and architecture. The work also discusses case studies to further highlight the benefits of BoMs. In addition, it identifies missing pieces in existing BoM implementations so that future research may identify bounds on where it could expect to make improvements and directly enable researchers to identify promising areas for exploration. Further, the authors provide valuable recommendations to tool developers, researchers, and standardizing organizations (policymakers), additionally benefitting critical infrastructure owners and government executives. This aids in paving a path for future work, thereby, providing suggestions to determine a tool for consumers that best suit their needs.

97 MATHEMATICS AND COMPUTING↗

The Current State of Radiation Dosimetry in Radionuclide Therapy

Radionuclide therapy combines the specificity of cancer cell targeting with the well-known cytotoxic effects of ionizing radiation. It has the potential to simultaneously eradicate both the primary tumor site as well as the metastatic extent of the disease throughout the body. Despite these advantages, a major limitation of radionuclide therapy is that conventional internal dosimetry methods have failed to accurately predict treatment outcomes in patients. It has been proposed that this shortcoming is due to the fact that therapeutic dosimetry is typically performed using methods developed for diagnostic imaging that do not consider patient specific anatomy, pharmacokinetics and dose heterogeneity. Even worse, dosimetry methods are often completely neglected during treatment planning and dose prescription is based on Body Surface Area/Weight (BSA/BW) and platelet counts. The most widely used internal dosimetry software is OLINDA/EXM (Organ Level Internal Dose Assessment for Exponential Modeling). OLINDA/EXM calculates absorbed doses using the formulism developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine. In its current implementation, OLINDA/EXM requires the use of S factors, which are derived in phantoms that do not accurately represent the actual patient. In addition, OLINDA/EXM assumes that the activity distribution in each organ and tumor is uniform, when it has been well established that activity distributions are often highly heterogeneous. Furthermore, the tumor is not modeled in the phantom, which introduces additional uncertainties in the calculation. Due to these limitations, there is a clear need for improved dosimetry methods for therapeutic nuclear medicine that utilize patient-specific imaging information. A variety of efforts are currently underway to develop such methods. There are two commercial software packages on the market for voxel level internal dosimetry: STRATOS (Philips Technologies, Aachen, Germany) and VoxelDose (DosiSoft, Cachan, France), but both packages are not widely used in clinical practice. In addition, several academic platforms have been developed. Similar to these offerings, RAPID is a robust, fast and multimodal platform. However, RAPID has been designed with tremendous flexibility to perform accurate dosimetry for any radiopharmaceutical in the pre-clinical and clinical setting in order to aid in drug development and to assist in radionuclide therapy treatment planning. This presentation will overview existing dosimetry platforms while focusing on the Monte Carlo-based platform developed at the University of Wisconsin known as RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID is a robust and universal platform that can provide accurate 3D internal dosimetry for any radiopharmaceutical during both the pre-clinical and clinical stages of drug development as well as clinical treatment planning in TRT. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiotherapy Breast Boost With Reduced Whole-Breast Dose Is Associated With Improved Cosmesis: The Results of a Comprehensive Assessment From the St. George and Wollongong Randomized Breast Boost Trial

Purpose: To evaluate comprehensively the effect of a radiotherapy boost on breast cosmetic outcomes after 5 years in patients treated with breast-conserving surgery. Methods: The St. George and Wollongong trial (NCT00138814) randomized 688 patients with histologically proven Tis-2, N 0-1, M0 carcinoma to the control arm of 50 Gy in 25 fractions (342 patients) and the boost arm of 45 Gy in 25 fractions to the whole breast followed by a 16 Gy in 8 fraction electron boost (346 patients). Five-year cosmetic outcomes were assessed by a panel subjectively in 385 patients and objectively using pBRA (relative breast retraction assessment). A subset of patients also had absolute BRA measurements. Clinician assessment and patient self-assessment of overall cosmetic and specific items as well as computer BCCT.core analysis were also performed. Results: The boost arm had improved cosmetic overall outcomes as scored by the panel and BCCT.core software with 79% (p = 0.016) and 81% (p = 0.004) excellent/good cosmesis respectively compared with 68% in no-boost arm. The boost arm also had lower pBRA and BRA values with a mean difference of 0.60 and 1.82 mm, respectively, but was not statistically significant. There was a very high proportion of overall excellent/good cosmetic outcome in 95% and 93% in the boost and no-boost arms using patient self-assessment. However, no difference in overall and specific items scored by clinician assessment and patient self-assessment was found. Conclusion: The results show the negative cosmetic effect of a 16-Gy boost is offset by a lower whole-breast dose of 45 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Sensitivity Analysis of MFiX-PIC Parameters Using Nodeworks, PSUADE, and DAKOTA

The study presented in this report was aimed to demonstrate UQ analysis performed not only with Nodeworks, but also two other well-established UQ software tools from the U.S. DOE’s National Laboratories (PSUADE from Lawrence Livermore National Laboratory and DAKOTA from Sandia National Laboratory). It is important to emphasize that the motivation of this study was not to determine the best UQ software, but to verify if the global sensitivity analyses from the end-to-end workflow in Nodeworks are consistent with the results of other two UQ software. The components of Nodeworks from Python’s ecosystem have been tested as standalone libraries. However, an assessment study for the complete workflow targeting a specific UQ analysis has not been performed for Nodeworks. Hence, this study is expected to serve as an equivalent of solution verification for Nodeworks using other established UQ tools as reference solution. For this purpose, three distinct flow configurations (i.e., settling bed, bubbling fluidized, and circulating fluidized bed) have been used as representative multiphase flow problems of interest. The results of the systematic simulation campaigns performed in an earlier study using the particle-in-cell (PIC) approach in the Multiphase Flow with Interphase eXchanges (MFIX) suite of solvers (i.e., MFiX-PIC) was utilized. The same set of tabulated results was provided as input to the different UQ software for global sensitivity analysis. Results for the three cases indicate that based on the Sobol’ Sensitivity Indices method the order of importance ranking determined by Nodeworks for the Sobol’ Total Sensitivity Indices is consistent with PSUADE and DAKOTA in each case for the five model parameters considered. The input files for Nodeworks for the three cases are also shared through NETL’s Gitlab repository for the reader interested in reproducibility and further analysis (See Section 1.2).

97 MATHEMATICS AND COMPUTING↗

Event-modeled Risk Assessment Using Linked Diagrams

In order to develop a dynamic probabilistic risk assessment capability, a prototype discrete event simulator was created as part of an LDRD that can model dynamic systems and generate probabilistic risk/reliability results. The development consisted of three major parts: 1. Development of a discrete event modeling software library 2. Design of a simulation object model for dynamic modeling 3. Construction of the graphical user interface (GUI) that will allow risk assessment analysts to more easily develop these models We called this new tool EMRALD. A key part of the EMRALD tool has been to develop an object-oriented software model that is flexible enough to support the varied dynamic simulation models (e.g., fails to operate, fails on demand). An object-oriented approach better matches the simulation model to real world objects and makes it more intuitive for the modeler. The interface represents actual physical components, specifically tracking how they interact. EMRALD is a discrete-event simulation tool that is coupled with a state-based diagramming graphical user interface. A key part of the EMRALD tool has been to develop an object-oriented software model that is flexible enough to support the varied dynamic simulation models (e.g., fails to operate, fails on demand). By having a state-based approach, we can integrate different hazards into a single comprehensive model. For example, a single model can include fire, flooding, transient, and seismic initiating events -- each of these events becomes a trigger into the state-based approach that tell the model to make a transition based upon the specific initiator. An object-oriented approach better matches the simulation model to real world objects and makes it more intuitive for the modeler. The interface represents actual physical components, specifically tracking how they interact.

Smith, CurtisLee↗

Advance Reservation Access Control Using Software-Defined Networking and Tokens

Advance reservation systems allow users to reserve dedicated bandwidth connection resources from an advanced high-speed network. A common use case for such systems is data transfers in distributed science environments in which a user wants exclusive access to the reservation. However, current advance network reservation methods cannot ensure exclusive access of a network reservation to the specific flow for which the user made the reservation. We present here a novel network architecture that addresses this limitation and ensures that a reservation is used only by the intended flow. We achieve this by leveraging software-defined networking (SDN) and token-based authorization. We use SDN to orchestrate and automate the reservation of networking resources, end-to-end and across multiple administrativedomains, and tokens to create a strong binding between the user or application that requested the reservation and the flows provisioned by SDN.

Kettimuthu, R.↗

High-order algorithmic developments and optimizations for large-scale GPU-accelerated simulations (Milestone CEED-MS36)

The goal of this milestone was to improve the high-order software ecosystem for CEED-enabled ECP applications by making progress on efficient matrix-free kernels targeting forthcoming ECP architectures. These kernels included matrix-free preconditioning and the development of new set of CEED solver bake-off problems. As part of this milestone, we also released the next version of the CEED software stack, CEED-4.0, reported on results from several application collaborations, and documented the efforts of porting to AMD GPUs for Frontier and other modern architectures, such as Fugaku. The specific tasks addressed in this milestone were: (1) Port and run CEED benchmarks/miniapps on Frontier EA systems; (2) Demonstrate performant libCEED integration in MFEM, Nek and applications; (3) Matrix-free preconditioning of high-order operators; (4) Benchmark problems for fast high-order solvers on GPU platforms; and (5) Public release of CEED-4.0. The artifacts delivered include the next version of the CEED software stack, CEED-4.0, the next libCEED release, libCEED-0.8, and a number of developments integrated within applications to improve their GPU and CPU performance and capabilities. See the CEED website, https://ceed.exascaleproject.org and the CEED GitHub organization, https://github.com/ceed for more details.

97 MATHEMATICS AND COMPUTING↗

Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

Purpose: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. Methods: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was tested throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. Results: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. Conclusions: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RuleMonkey: software for stochastic simulation of rule-based models

Background: The system-level dynamics of many molecular interactions, particularly protein-protein interactions, can be conveniently represented using reaction rules, which can be specified using model-specification languages, such as the BioNetGen language (BNGL). A set of rules implicitly defines a (bio)chemical reaction network. The reaction network implied by a set of rules is often very large, and as a result, generation of the network implied by rules tends to be computationally expensive. Moreover, the cost of many commonly used methods for simulating network dynamics is a function of network size. Together these factors have limited application of the rule-based modeling approach. Recently, several methods for simulating rule-based models have been developed that avoid the expensive step of network generation. The cost of these “network-free” simulation methods is independent of the number of reactions implied by rules. Software implementing such methods is now needed for the simulation and analysis of rule-based models of biochemical systems. Results: Here, we present a software tool called RuleMonkey, which implements a network-free method for simulation of rule-based models that is similar to Gillespie’s method. The method is suitable for rule-based models that can be encoded in BNGL, including models with rules that have global application conditions, such as rules for intramolecular association reactions. In addition, the method is rejection free, unlike other network-free methods that introduce null events, i.e., steps in the simulation procedure that do not change the state of the reaction system being simulated. We verify that RuleMonkey produces correct simulation results, and we compare its performance against DYNSTOC, another BNGL-compliant tool for network-free simulation of rule-based models. We also compare RuleMonkey against problem-specific codes implementing network-free simulation methods. Conclusions: RuleMonkey enables the simulation of rule-based models for which the underlying reaction networks are large. It is typically faster than DYNSTOC for benchmark problems that we have examined. RuleMonkey is freely available as a stand-alone application http://public.tgen.org/rulemonkey. It is also available as a simulation engine within GetBonNie, a web-based environment for building, analyzing and sharing rule-based models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmentally Adaptive, Multiband Software-Defined-Radar for Monitoring of Item of Interest in a Dynamically Cluttered Room

High-resolution multi-frequency radars when networked together, form a robust and seamless monitoring system for high-valued items. The multi-look-direction radar network investigated by LLNL and DSI, operates at 77 GHz and 5.8GHz, and is capable of detection at centimeter resolution movement of objects of interest. This dual frequency radar (unlike optical methods) can operate under various environments with conditions such a smoke, dust, and other natural or manmade obscurations. In addition, the multiband network radar is based on low-cost FCC approved EM specifications and can be scaled with the dimensions of the room and objects under consideration by user-defined inputs. Furthermore, the underlying radar signal processing based on software-defined radar engine is adaptive to its operational environment, where operators can input the size of the facility and object of interest and the distance between the object and radar. Finally, this multi-frequency radar employs a host of change detection and machine learning algorithms to reach performance levels in terms of high probability of detection and low false alarm rates while the monitoring state of the object can be reported remotely.

42 ENGINEERING↗

New risk metrics and mathematical tools for risk analysis: Current and future challenges

The current status of the food safety supply world wide, has led Food and Agriculture Organization (FAO) and World Health Organization (WHO) to establishing Risk Analysis as the single framework for building food safety control programs. A series of guidelines and reports that detail out the various steps in Risk Analysis, namely Risk Management, Risk Assessment and Risk Communication is available. The Risk Analysis approach enables integration between operational food management systems, such as Hazard Analysis Critical Control Points, public health and governmental decisions. To do that, a series of new Risk Metrics has been established as follows: i) the Appropriate Level of Protection (ALOP), which indicates the maximum numbers of illnesses in a population per annum, defined by quantitative risk assessments, and used to establish; ii) Food Safety Objective (FSO), which sets the maximum frequency and/or concentration of a hazard in a food at the time of consumption that provides or contributes to the ALOP. Given that ALOP is rather a metric of the public health tolerable burden (it addresses the total ‘failure’ that may be handled at a national level), it is difficult to be interpreted into control measures applied at the manufacturing level. Thus, a series of specific objectives and criteria for performance of individual processes and products have been established, all of them assisting in the achievement of FSO and hence, ALOP. In order to achieve FSO, tools quantifying the effect of processes and intrinsic properties of foods on survival and growth of pathogens are essential. In this context, predictive microbiology and risk assessment have offered an important assistance to Food Safety Management. Predictive modelling is the basis of exposure assessment and the development of stochastic and kinetic models, which are also available in the form of Web-based applications, e.g., COMBASE and Microbial Responses Viewer), or introduced into user-friendly softwares, (e.g., Seafood Spoilage Predictor) have evolved the use of information systems in the food safety management. Such tools are updateable with new food-pathogen specific models containing cardinal parameters and multiple dependent variables, including plate counts, concentration of metabolic products, or even expression levels of certain genes. Then, these tools may further serve as decision-support tools which may assist in product logistics, based on their scientifically-based and “momentary” expressed spoilage and safety level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗