Pivotal trial characteristics and types of endpoints used to support Food and Drug Administration rare disease drug approvals between 2013 and 2022

Background/aims Rare disease drug development faces unique challenges, such as genotypic and phenotypic heterogeneity within small patient populations and a lack of established outcome measures for conditions without previously successful drug development programs. These challenges complicate the process of selecting the appropriate trial endpoints and conducting clinical trials in rare diseases. In this descriptive study, we examined novel drug approvals for non-oncologic rare diseases by the U.S. Food and Drug Administration’s Center for Drug Evaluation and Research over the past decade and characterized key regulatory and trial design elements with a focus on the primary efficacy endpoint utilized as the basis of approval. Methods Using the Food and Drug Administration’s Data Analysis Search Host database, we identified novel new drug applications and biologics license applications with orphan drug designation that were approved between 2013 and 2022 for non-oncologic indications. From Food and Drug Administration review documents and other external databases, we examined characteristics of pivotal trials for the included drugs, such as therapeutic area, trial design, and type of primary efficacy endpoints. Differences in trial design elements associated with primary efficacy endpoint type were assessed such as randomization and blinding. Then, we summarized the primary efficacy endpoint types utilized in pivotal trials by therapeutic area, approval pathway, and whether the disease etiology is well defined. Results One hundred and seven drugs that met our inclusion criteria were approved between 2013 and 2022. Assessment of the 107 drug development programs identified 150 pivotal trials that were subsequently analyzed. The pivotal trials were mostly randomized (80%) and blinded (69.3%). Biomarkers (41.1%) and clinical outcomes (42.1%) were commonly utilized as primary efficacy endpoints. Analysis of the use of clinical trial design elements across trials that utilized biomarkers, clinical outcomes, or composite endpoints did not reveal statistically significant differences. The choice of primary efficacy endpoint varied by the drug’s therapeutic area, approval pathway, and whether the indicated disease etiology was well defined. For example, biomarkers were commonly selected as primary efficacy endpoints in hematology drug approvals (70.6%), whereas clinical outcomes were commonly selected in neurology drug approvals (69.6%). Further, if the disease etiology was well defined, biomarkers were more commonly used as primary efficacy endpoints in pivotal trials (44.7%) than if the disease etiology was not well defined (27.3%). Discussion In the past 10 years, numerous novel drugs have been approved to treat non-oncologic rare diseases in various therapeutic areas. To demonstrate their efficacy for regulatory approval, biomarkers and clinical outcomes were commonly utilized as primary efficacy endpoints. Biomarkers were not only frequently used as surrogate efficacy endpoints in accelerated approvals, but also in traditionally approved rare disease drugs. The choice of primary efficacy endpoints varied by therapeutic area, approval pathway, and understanding of disease etiology.

Hong, Kyungwan [Rare Diseases Team, Office of New ↗

A statistical study of H i gas in nearby narrow-line AGN-hosting galaxies

As a quenching mechanism, active galactic nucleus (AGN) feedback could suppress on going star formation in host galaxies. On the basis of a sample of galaxies selected from the Arecibo Legacy Fast ALFA (ALFALFA) H i survey, the dependence of the H i mass (M{sub H} {sub i}), stellar mass (M{sub *}), and H i-to-stellar mass ratio (M{sub H} {sub i}/M{sub *}) on various tracers of AGN activity are presented and analyzed in this paper. Almost all the AGN hostings in this sample are gas-rich galaxies, and there is not any evidence to indicate that the AGN activity could increase or decrease either M{sub H} {sub i} or M{sub H} {sub i}/M{sub *}. The position of the cold neutral gas cannot be fixed accurately based only on available H i data, due to the large beam size of ALFALFA survey. In addition, even though AGN hostings are more easily detected by an H i survey compared with absorption line galaxies, these two types of galaxies show similar star formation history. If an AGN hosting would ultimately evolve into an old red galaxy with low cold gas, then when and how the gas has been exhausted must be solved by future hypotheses and observations.

79 ASTRONOMY AND ASTROPHYSICS↗

BROADBAND IMAGING SEGREGATION OF z approx 3 Lyalpha EMITTING AND Lyalpha ABSORBING GALAXIES

The spectral properties of Lyman break galaxies (LBGs) offer a means to isolate pure samples displaying either dominant Lyalpha in absorption or Lyalpha in emission using broadband information alone. We present criteria developed using a large z approx 3 LBG spectroscopic sample from the literature that enables large numbers of each spectral type to be gathered in photometric data, providing good statistics for multiple applications. In addition, we find that the truncated faint, blue-end tail of z approx 3 LBG population overlaps and leads directly into an expected Lyalpha emitter (LAE) population. As a result, we present simple criteria to cleanly select large numbers of z approx 3 LAEs in deep broadband surveys. We present the spectroscopic results of 32r' approx< 25.5 LBGs and r' approx< 27.0 LAEs at z approx 3 preselected in the Canada-France-Hawaii Telescope Legacy Survey that confirm these criteria.

79 ASTRONOMY AND ASTROPHYSICS↗

THE DEMOGRAPHICS OF BROAD-LINE QUASARS IN THE MASS-LUMINOSITY PLANE. II. BLACK HOLE MASS AND EDDINGTON RATIO FUNCTIONS

We employ a flexible Bayesian technique to estimate the black hole (BH) mass and Eddington ratio functions for Type 1 (i.e., broad line) quasars from a uniformly selected data set of {approx}58, 000 quasars from the Sloan Digital Sky Survey (SDSS) DR7. We find that the SDSS becomes significantly incomplete at M {sub BH} {approx}< 3 Multiplication-Sign 10{sup 8} M {sub Sun} or L/L {sub Edd} {approx}< 0.07, and that the number densities of Type 1 quasars continue to increase down to these limits. Both the mass and Eddington ratio functions show evidence of downsizing, with the most massive and highest Eddington ratio BHs experiencing Type 1 quasar phases first, although the Eddington ratio number densities are flat at z < 2. We estimate the maximum Eddington ratio of Type 1 quasars in the observable universe to be L/L {sub Edd} {approx} 3. Consistent with our results in Shen and Kelly, we do not find statistical evidence for a so-called sub-Eddington boundary in the mass-luminosity plane of broad-line quasars, and demonstrate that such an apparent boundary in the observed distribution can be caused by selection effect and errors in virial BH mass estimates. Based on the typical Eddington ratio in a given mass bin, we estimate growth times for the BHs in Type 1 quasars and find that they are comparable to or longer than the age of the universe, implying an earlier phase of accelerated (i.e., with higher Eddington ratios) and possibly obscured growth. The large masses probed by our sample imply that most of our BHs reside in what are locally early-type galaxies, and we interpret our results within the context of models of self-regulated BH growth.

79 ASTRONOMY AND ASTROPHYSICS↗

Near optimal energy selective x-ray imaging system performance with simple detectors

Purpose: This article describes a method to achieve near optimal performance with low energy resolution detectors. Tapiovaara and Wagner [Phys. Med. Biol. 30, 519-529 (1985)] showed that an energy selective x-ray system using a broad spectrum source can produce images with a larger signal to noise ratio (SNR) than conventional systems using energy integrating or photon counting detectors. They showed that there is an upper limit to the SNR and that it can be achieved by measuring full spectrum information and then using an optimal energy dependent weighting. Methods: A performance measure is derived by applying statistical detection theory to an abstract vector space of the line integrals of the basis set coefficients of the two function approximation to the x-ray attenuation coefficient. The approach produces optimal results that utilize all the available energy dependent data. The method can be used with any energy selective detector and is applied not only to detectors using pulse height analysis (PHA) but also to a detector that simultaneously measures the total photon number and integrated energy, as discussed by Roessl et al. [Med. Phys. 34, 959-966 (2007)]. A generalization of this detector that improves the performance is introduced. A method is described to compute images with the optimal SNR using projections in a ''whitened'' vector space transformed so the noise is uncorrelated and has unit variance in both coordinates. Material canceled images with optimal SNR can also be computed by projections in this space. Results: The performance measure is validated by showing that it provides the Tapiovaara-Wagner optimal results for a detector with full energy information and also a conventional detector. The performance with different types of detectors is compared to the ideal SNR as a function of x-ray tube voltage and subject thickness. A detector that combines two bin PHA with a simultaneous measurement of integrated photon energy provides near ideal performance across a wide range of operating conditions. Conclusions: Low energy resolution detectors can be used in energy selective x-ray imaging systems to produce images with near optimal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image encryption and watermarking combined dynamic chaotic hopping pattern with double random phase encoding DRPE

In modern civilization information, security is a crucial problem. Image encryption and watermarking can effectively protect information from unauthorized access. This paper introduces a new vigorous symmetric optical image encryption and watermarking technique. This technique depends on a novel dynamic delay chaotic hopping pattern (DDCHP) combined with double random phase encoding (DRPE). To get a robust watermark image, the plain image is first watermarked with a binary secret message using a new chaotic hopping pattern (CHP) and then encrypted using a DRPE system that is controlled by double random independent keys generated with double DDCHP. In this symmetric cryptosystem, three different chaotic maps are used to enlarge the key space of the proposed cryptosystem against brute-force attack and overcome the linearity and vulnerable of the classical DRPE. The system keys are hypersensitive and their initial parameters are selected carefully. Security scrutiny proves the efficiency of the suggested cryptosystem. Therefore, the obtained simulation results prove that the cryptosystem is robust enough against the known attacks, such as statistical attack (uniform histograms of different encrypted images, correlation coefficients between the plain and the encrypted image is as low as 5.46 × 10{sup −6}), differential attack (99.99% NPCR and 38.6% UACI), brute force attack (large enough key space), and entropy attack. Moreover, the robustness of the watermark (secret message) is proved due to the solidity of CHP. The proposed approach can be used in different implementations like secure military communications, e-finance, e-healthcare, authenticated multimedia broadcasting, etc.

97 MATHEMATICS AND COMPUTING↗

MADHAT: Model-Agnostic Dark Halo Analysis Tool

We present the Model-Agnostic Dark Halo Analysis Tool (MADHAT), a numerical tool which implements a Fermi-LAT data-driven, model-independent analysis of gamma-ray emission from dwarf satellite galaxies and dwarf galaxy candidates due to dark matter annihilation, dark matter decay, or other nonstandard or unknown astrophysics. This tool efficiently provides statistical upper bounds on the number of observed photons in excess of the number expected, based on empirical determinations of foregrounds and backgrounds, using a stacked analysis of any selected set of dwarf targets. It also calculates the resulting bounds on the properties of dark matter under any assumptions the user makes regarding dark sector particle physics or astrophysics. As an application, we determine new bounds on Sommerfeld-enhanced dark matter annihilation in a set of eight dwarfs. MADHAT v1.0 includes 58 dwarfs and dwarf candidate targets, and we discuss future planned developments. MADHAT is available and will be maintained at https://github.com/MADHATdm.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dosimetric Analysis of IMRT and Multistatic Fields Techniques for Left Breast Radiotherapy

The purpose of this study was to analyze the dosimetric difference between intensity-modulated radiation therapy (IMRT) using 3 or 5 beams and multistatic field technique (MSF) in radiotherapy of the left breast. We made comparative analysis of two kinds of radiotherapy that can achieve improved dose homogeneity. First is a MSF that uses both major and small irradiation fields at the same time. The other is IMRT using 3 or 5 beams with an inverse planning system using multiple static multileaf collimators. We made treatment plans for 16 early left breast cancer patients who were randomly selected and had undergone breast conserving surgery and radiotherapy, and analyzed them in the dosimetric aspect. For the mean values of V{sub 95} and dose homogeneity index, no statistically significant difference was observed among the three therapies. Extreme hot spots receiving >110% of prescribed dose were not found in any of the three methods. Using Tukey's test, IMRT showed a significantly larger increase in exposure dose to the ipsilateral lung and the heart than MSF in the low-dose area, but in the high-dose area, MSF showed a slight increase. To improve dose homogeneity, the application of MSF, which can be easily planned and applied more widely, is considered optimal as an alternative to IMRT for radiotherapy of early left breast cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Contributions of vegetation heterogeneity within tower footprint to CO 2 flux estimations through graph neural network modeling

Net ecosystem exchange of CO 2 (Fc) measured directly by eddy covariance towers is based on various assumptions, including large, flat and homogenous land cover type. In reality, often a tower site is not large enough for flux measurements, and landscapes consist of patches of different land cover types within the flux footprint. In addition, some portions of fluxes are contributed by different cover types when a footprint exceeds the size of the target ecosystem. The contributions of non-dominant patches to Fc are often ignored. Here, in this study, we propose a novel integrated modeling framework that combines random forest (RF) and XGBoost with a residual correction module based on a deep graph convolutional network (DeeperGCN) to simulate Fc for seven flux measurement sites in southwest Michigan. High-resolution remote sensing vegetation indices, soil properties, meteorological variables, and footprint-weighted spatial features were used as model inputs at three spatial resolutions (10 m, 20 m, 30 m), and their importance in predicting Fc with DeeperGCN was assessed. We found that residual correction using DeeperGCN significantly improved prediction accuracy, with the R 2 increasing from 0.9098 to 0.9479 for RF and from 0.9235 to 0.9433 for XGBoost. At site level, the maximum improvement in R 2 reached 0.1617. Paired t-tests confirmed that these improvements were statistically significant (p < 0.05). Among all predictors, leaf area index and incoming shortwave radiation emerged as the dominant drivers of spatial residual variation, followed by precipitation, relative humidity, and selected vegetation indices. The 20 m resolution yielded the best balance between model performance and computational efficiency. In conclusion, our modeling framework effectively captures both spatial heterogeneity and nonlinear interactions, offering a robust solution for spatially explicit flux modeling in structurally diverse ecosystems beyond the study sites.

footprint model↗

Detection of special nuclear materials with the associate particle technique

In the frame of the French trans-governmental R and D program against chemical, biological, radiological, nuclear and explosives (CBRN-E) threats, CEA is studying the detection of Special Nuclear Materials (SNM) by neutron interrogation with fast neutrons produced by an associated particle sealed tube neutron generator. The deuterium-tritium fusion reaction produces an alpha particle and a 14 MeV neutron almost back to back, allowing tagging neutron emission both in time and direction with an alpha particle position-sensitive sensor embedded in the generator. Fission prompt neutrons and gamma rays induced by tagged neutrons which are tagged by an alpha particle are detected in coincidence with plastic scintillators. This paper presents numerical simulations performed with the MCNP-PoliMi Monte Carlo computer code and with post processing software developed with the ROOT data analysis package. False coincidences due to neutron and photon scattering between adjacent detectors (cross talk) are filtered out to increase the selectivity between nuclear and benign materials. Accidental coincidences, which are not correlated to an alpha particle, are also taken into account in the numerical model, as well as counting statistics, and the time-energy resolution of the data acquisition system. Such realistic calculations show that relevant quantities of SNM (few kg) can be distinguished from cargo and shielding materials in 10 min acquisitions. First laboratory tests of the system under development in CEA laboratories are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pseudorandom number generation using chaotic true orbits of the Bernoulli map

We devise a pseudorandom number generator that exactly computes chaotic true orbits of the Bernoulli map on quadratic algebraic integers. Moreover, we describe a way to select the initial points (seeds) for generating multiple pseudorandom binary sequences. This selection method distributes the initial points almost uniformly (equidistantly) in the unit interval, and latter parts of the generated sequences are guaranteed not to coincide. We also demonstrate through statistical testing that the generated sequences possess good randomness properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Young stellar object variability (YSOVAR): Long timescale variations in the mid-infrared

The YSOVAR (Young Stellar Object VARiability) Spitzer Space Telescope observing program obtained the first extensive mid-infrared (3.6 and 4.5 μm) time series photometry of the Orion Nebula Cluster plus smaller footprints in 11 other star-forming cores (AFGL 490, NGC 1333, Mon R2, GGD 12-15, NGC 2264, L1688, Serpens Main, Serpens South, IRAS 20050+2720, IC 1396A, and Ceph C). There are ∼29,000 unique objects with light curves in either or both IRAC channels in the YSOVAR data set. We present the data collection and reduction for the Spitzer and ancillary data, and define the 'standard sample' on which we calculate statistics, consisting of fast cadence data, with epochs roughly twice per day for ∼40 days. We also define a 'standard sample of members' consisting of all the IR-selected members and X-ray-selected members. We characterize the standard sample in terms of other properties, such as spectral energy distribution shape. We use three mechanisms to identify variables in the fast cadence data—the Stetson index, a χ{sup 2} fit to a flat light curve, and significant periodicity. We also identified variables on the longest timescales possible of six to seven years by comparing measurements taken early in the Spitzer mission with the mean from our YSOVAR campaign. The fraction of members in each cluster that are variable on these longest timescales is a function of the ratio of Class I/total members in each cluster, such that clusters with a higher fraction of Class I objects also have a higher fraction of long-term variables. For objects with a YSOVAR-determined period and a [3.6]-[8] color, we find that a star with a longer period is more likely than those with shorter periods to have an IR excess. We do not find any evidence for variability that causes [3.6]-[4.5] excesses to appear or vanish within our data set; out of members and field objects combined, at most 0.02% may have transient IR excesses.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of nuclear reaction cross sections on excited nuclei with the coupled-channels method

We calculate nuclear cross sections on excited nuclei in the fast neutron energy range. We partition the whole process into two contributions: the direct reaction part and the compound nuclear reactions. A coupled-channels method is used for calculating the direct transition of the nucleus from the initial excited state, which is a member of the ground-state rotational band, to the final ground and excited low-lying levels. This process is strongly affected by the channel coupling. The compound nuclear reactions on the excited state are calculated with the statistical Hauser-Feshbach model, with the transmission coefficients obtained from the coupled-channels calculation. The calculations are performed for a strongly deformed nucleus {sup 169}Tm, and selected cross sections for the ground and first excited states are compared. The calculation is also made for actinides to investigate possible modification to the fission cross section when the target is excited. It is shown that both the level coupling for the entrance channel, and the different target spin, change the fission cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-253: Evaluation of 4DCT Images with Correlation of RPM Signals to Tumor Motion for Respiratory-Gated Radiotherapy

Purpose: The amplitudes of lung tumor target motion and RPM signals are different from each other. Also, RPM system does not have in-depth RPM signal analysis tool. We have developed an algorithm that analyzes RPM signals for its stability as well as correlativity to the tumor motion. Methods: We used a Philips Big Bore CT scanner with a Varian Real-Time Position Management™ (RPM) system attached. 4DCT images were reviewed and tumor motion amplitudes of full breathing in superior-inferior, anterior-posterior, and left-right directions were measured. RPM signals were analyzed with the algorithm developed with Matlab. Average signal period, amplitude and statistical stability of the full breathing pattern as well as the pattern around full expiration were calculated. RPM signal amplitudes were normalized to measured tumor motion amplitudes so that selected gating phases (30%–70% or 40%–60%) allow tumor motion under 5.0mm. Results: Twelve patient cases were analyzed in this study with GTV sizes ranged from 1.0cm to 3.0cm diameter. The periods and amplitudes of RPM signal ranged from 3.1seconds to 6.5seconds and from 0.2cm to 1.7cm, respectively. RPM signals were most stable at full expiration. The standard deviation of the RPM signal peaks at full expiration was <0.11cm, and that of gated amplitudes was <0.25cm. Tumor motion amplitudes were primary in superior-inferior direction and minor (<=0.2cm) in other directions on all analyzed cases, ranged from 0.2cm to 2.5cm. The amplitudes increases with the tumor located toward the diaphragm. The gated phases were selected so that the average gated tumor motion amplitude as well as that plus deviation became under 0.5cm in superior-inferior direction. Conclusion: We were able to determine the respiratory-gated phases in RPM signals employing measured tumor motion amplitudes as well as developed RPM signal analyzer through correlation process. The RPM signal amplitudes do not represent tumor motion because of its location.

60 APPLIED LIFE SCIENCES↗

SU-F-T-150: Comparing Normal Tissue Irradiated Volumes for Proton Vs. Photon Treatment Plans On Lung Patients

Purpose: The aim of this work is to compare the “irradiated volume” (IRV) of normal tissues receiving 5, 20, 50, 80 and 90% or higher of the prescription dose with passively scattered proton therapy (PSPT) vs. IMRT of lung cancer patients. The overall goal of this research is to understand the factors affecting outcomes of a randomized PSPT vs. IMRT lung trial. Methods: Thirteen lung cancer patients, selected randomly, were analyzed. Each patient had PSPT and IMRT 74 Gy (RBE) plans meeting the same normal tissue constraints generated. IRVs were created for pairs of IMRT and PSPT plans on each patient. The volume of iGTV, (respiratory motion-incorporated GTV) was subtracted from each IRV to create normal tissue irradiated volume IRVNT. The average of IRVNT DVHs over all patients was also calculated for both modalities and inter-compared as were the selected dose-volume indices. Probability (p value) curves were calculated based on the Wilcoxon matched-paired signed-rank test to determine the dose regions where the statistically significant differences existed. Results: As expected, the average 5, 20 and 50% IRVNT’s for PSPT was found to be significantly smaller than for IMRT (p < 0.001, 0.01, and 0.001 respectively). However, the average 90% IRVNT for PSPT was greater than for IMRT (p = 0.003) presumably due to larger penumbra of protons and the long range of protons in lower density media. The 80% IRVNT for PSPT was also larger but not statistically distinguishable (p = .224). Conclusion: PSPT modality has smaller irradiated volume at lower doses, but larger volume at high doses. A larger cohort of lung patients will be analyzed in the future and IRVNT of patients treated with PSPT and IMRT will be compared to determine if the irradiated volumes (the magnitude of “dose bath”) correlate with outcomes.

60 APPLIED LIFE SCIENCES↗

MC performance study for an early $v_μ$ charged-current inclusive analysis with MicroBooNE

This note describes an analysis performed on Monte Carlo data to evaluate the sensitivity of MicroBooNE for an early ν µ charged-current inclusive cross section measurement. Such an analysis is intended to be done using the first three months of Booster Neutrino Beam data. The event selection is entirely based on an automated event reconstruction. The Monte Carlo prediction for a flux-integrated and single differential cross section measurement with an approximate estimation of statistical and systematic uncertainties for the MicroBooNE detector as designed is presented. This allows the comparison of the sensitivity of MicroBooNE to theory and other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an Open-source Alloy Selection and Lifetime Assessment Tool for Structural Components in CSP

Lack of sufficient data on high temperature mechanical and corrosion behavior of structural materials is a huge barrier in the technological maturity of current and future Concentrating Solar Power (CSP) technologies. Rapid development and selection of materials cannot be achieved by expensive and time-consuming acquisition of experimental data. The goal of the proposed work is development of an open-source alloy selection and lifetime prediction tool that will integrate validated physics-based models to describe influence of temperature, alloy composition, environment and component geometry (thickness) on mechanical and corrosion behavior of Ni and Fe-based alloys employed in molten salts/sCO 2 heat exchangers. This one-year project leveraged the extensive dataset on the creep\corrosion behavior of candidate materials generated at ORNL through past projects and input from current collaborations with industrial partners. Based on previous experience and the feedback provided by industry (Brayton Energy and Echogen), three candidate materials of interest, Ni-based alloys 740H, 282 and 625 and application-specific operating conditions (max. temperature of 730 °C and stress of 150 MPa) were identified for the heat exchanger. An extensive corrosion and creep dataset was assimilated for the relevant operating conditions and was supported by detailed characterization of about 100 metallographic cross-sections. The corrosion dataset consisted of scanning electron microscopy images (secondary electron and backscatter electron), measured concentration profiles of alloying elements using energy dispersive X-ray spectroscopy (EDS), widths of denuded zones (dissolution of strengthening phases) and depths of attack in molten KCl-MgCl 2 mixtures using image analyses. The creep dataset comprised of creep rupture data and creep strain curves (for 740H and 282). Coupled thermodynamic-kinetic microstructure-based models were employed to predict the stress-corrosion induced compositional and phase evolutions in the alloy during operation under the identified operating conditions. Reduced order models were developed from advanced physics-based models and were integrated in a user-friendly alloy selection tool. The corrosion model was able to predict the time to a critical Cr concentration at the oxide/alloy interface (chemical lifetime) within ±10% (1 standard deviation) of typical statistical variation in corrosion tests and EDS measurement errors (±0.5 wt%). The initial scope of the project was limited to predict creep rupture times (Larson-Miller parameter). Based on the input provided by industry, the mechanical lifetime of the heat exchanger is governed by accumulated creep strains (2%) rather than creep rupture. To be able to predict the times to specific creep strains, a more extensive creep model development was undertaken largely beyond the initial scope of the project. The continuum damage mechanics creep model was able to predict times to 2% creep strain, t 2% with an accuracy of ±500h. Ultimately, a screening protocol for SiC was generated to demonstrate the pathway for integration of one of the currently immature materials from a commercial adoption standpoint in the current material evaluation tool. The modeling tool developed here is accessible to the science community and stakeholders and lays the foundation for methods that will enable a rapid evaluation of optimum materials for CSP applications and reliable prediction of material degradation thereby considerably reducing operational costs, improving reliability and increasing overhaul intervals. However, the complete potential of such a tool to include a wider range of materials and test conditions can only be realized with a more concentrated combined experimental-characterization-computation effort.

14 SOLAR ENERGY↗

Investigation of Three-Dimensional Microstructure of Tricalcium Silicate (C 3 S) by Electron Microscopy

A serial block-face scanning electron microscopy (SBFSEM) system, composed of a scanning electron microscope (SEM) and an ultra-microtome installed within the SEM vacuum chamber, has been used to characterize the three-dimensional (3D) microstructure of tricalcium silicate (C 3 S) grains embedded in epoxy resin. A selection of C 3 S grains were segmented and rendered with 3D-image processing software, which allowed the C 3 S grains to be clearly visualized and enabled statistically quantitative analysis. The results show that about 5% of the C 3 S grains have volumes larger than 1 μm 3 and the average volume of the grains is 25 μm 3 . Pores can also be clearly seen in the biggest C 3 S grain, the volume of which is 3.6 × 10 4 μm 3 , and the mean volume and total volume of all the pores within this grain are 4.8 μm 3 and 3.0 × 10 3 μm 3 , respectively. This work provides a new approach for the characterization of the 3D spatial structure of raw C 3 S materials, and the resulting 3D structure of the raw C 3 S is important for further systematic research on the relationships between the spatial microstructure and the hydration kinetics of C 3 S and other cement minerals.

36 MATERIALS SCIENCE↗