Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems [Slides]

The study performed two related analyses using data from a new-construction residential community equipped with rooftop solar and storage (S+S) in Arizona. The study analyzed the factors that determine customer electricity cost savings from S+S adoption. The research compared the Arizona case study data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, NREL explored ways to improve such models and, conversely, use modeled results to suggest improvements to S+S dispatches.

14 SOLAR ENERGY↗

Performance of a full-scale ITER metal hydride storage bed in comparison with requirements

The storage of hydrogen isotopes as metal hydride is the technique chosen for the ITER Tritium Plant Storage and Delivery System (SDS). A prototype storage bed of a full-scale has been designed, manufactured and intensively tested at the Tritium Laboratory, addressing main performance parameters specified for the ITER application. The main requirements for the hydrogen storage bed are a strict physical limitation of the tritium storage capacity (currently 70 g T{sub 2}), a high supply flow rate of hydrogen isotopes, in-situ calorimetry capabilities with an accuracy of 1 g and a fully tritium compatible design. The pressure composition isotherm of the ZrCo hydrogen system, as a reference material for ITER, is characterised by significant slope. As a result technical implementation of the ZrCo hydride bed in the SDS system requires further considerations. The paper presents the experience from the operation of ZrCo getter bed including loading/de-loading operation, calorimetric loop performance, and active gas cooling of the bed for fast absorption operation. The implications of hydride material characteristics on the SDS system configuration and design are discussed. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural assessment of a Space Station solar dynamic heat receiver thermal energy storage canister

This paper assesses the structural performance of a Space Station thermal energy storage (TES) canister subject to orbital solar flux variation and engine cold start-up operating conditions. The impact of working fluid temperature and salt-void distribution on the canister structure are assessed. Both analytical and experimental studies were conducted to determine the temperature distribution of the canister. Subsequent finite-element structural analyses of the canister were performed using both analytically and experimentally obtained temperatures. The Arrhenius creep law was incorporated into the procedure, using secondary creep data for the canister material, Haynes-188 alloy. The predicted cyclic creep strain accumulations at the hot spot were used to assess the structural performance of the canister. In addition, the structural performance of the canister based on the analytically-determined temperature was compared with that based on the experimentally-measured temperature data.

Tong, M. T.↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Thermal stability study of a new guanidine suppressor for the next-generation caustic-side solvent extraction process

Cesium stripping performance of thermally stressed solvent degrades slowly over time in batch tests of the Next Generation Caustic-Side Solvent Extraction (NGS) process. NGS is currently used at pilot scale at the Savannah River Site for the selective removal of cesium from high-level salt waste. Recently a new guanidine, N,N',N" -tris(3,7-dimethyloctyl)guanidine (TiDG), was chosen for use as the suppressor, a lipophilic organic base needed for stripping, and the present study was undertaken to address the question of its stability. The NGS process solvent was evaluated for a period of three months under a variety of temperature and storage conditions. The performance of the solvent was tested at 30-day increments using a standard extraction, scrub, strip, and extraction (ES 2 S 3 E) sequence. Lastly, the results provide insight on the effects of storage and process conditions, the stripping behavior of TiDG, and the stability of the new solvent composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comprehensive Study on Energy Efficiency and Performance of Flash-based SSD

Use of flash memory as a storage medium is becoming popular in diverse computing environments. However, because of differences in interface, flash memory requires a hard-disk-emulation layer, called FTL (flash translation layer). Although the FTL enables flash memory storages to replace conventional hard disks, it induces significant computational and space overhead. Despite the low power consumption of flash memory, this overhead leads to significant power consumption in an overall storage system. In this paper, we analyze the characteristics of flash-based storage devices from the viewpoint of power consumption and energy efficiency by using various methodologies. First, we utilize simulation to investigate the interior operation of flash-based storage of flash-based storages. Subsequently, we measure the performance and energy efficiency of commodity flash-based SSDs by using microbenchmarks to identify the block-device level characteristics and macrobenchmarks to reveal their filesystem level characteristics.

99 GENERAL AND MISCELLANEOUS↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Nanoporous Architectures for Multifaceted Clean Energy Applications

Recently, there has been immense interest in the design and synthesis of highly porous organic architectures due to their multifaceted potentials for applications that include gas storage, separation, conductivity, and catalysis. The chemical composition, physical, and textural properties are dictated during synthesis. This allows for the production of materials with enhanced properties relevant to their respective applications. With the exception of microcrystalline covalent-organic frameworks (COFs), these polymeric materials are amorphous with considerably high porosity and well-defined cavities, which render them highly attractive, especially in adsorptive gas storage. Such desirable traits are imparted into organic materials through the use of rigid building blocks that direct the growth of polymer networks without the aid of templating agents. During the award period, we focused our efforts on the synthesis and characterization of porous organic polymers constructed through B-N and C-N bond formation and investigated their performance in gas storage (H 2 , CH 4 , CO 2 ) and selective CO 2 binding over CH 4 and N 2 . We also demonstrated that thermolysis of nitrogen rich organic polymers afford highly porous nitrogen-rich porous carbons that show remarkable CO 2 capture and separation properties.

36 MATERIALS SCIENCE↗

Metal-Organic Frameworks (MOFs) Containing Frustrated Lewis Pairs (FLP) for H 2 Storage at Ambient Temperature

This final technical report summarizes the key accomplishments of the HyMarc Seedling project to develop new materials based on metal-organic framework (MOF) incorporated with frustrated Lewis pairs (FLP) termed as FLP@MOF, as next-generation of hydrogen storage sorbent that can meet or exceed DOE’s 2025 performance target of hydrogen storage gravimetric density of 5.5 wt.% and volumetric density of 0.040 kg H 2 /L. The project was carried out by the PI Shengqian Ma at the University of North Texas (UNT) along with Argonne National Laboratory (ANL) to develop FLP@MOF systems that exhibit high hydrogen storage capacity at ambient temperature under pressure <100 bar, as well as to obtain improved fundamental understanding of hydrogen adsorption mechanism in FLP@MOF system.

08 HYDROGEN↗

Electrical Energy Storage Data Submission Guidelines

Energy storage technologies are positioned to play a substantial role in power delivery systems. They are being touted as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, due to their relative infancy, there is a lack of knowledge on how these resources truly operate over time. Data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verifying the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data the provider supplies for analysis. After review of energy storage data received from several providers, it has become clear that some of these data are inconsistent and incomplete, raising the question of their efficacy for robust analysis. This report reviews and proposes general guidelines such as sampling rates and data points that providers must supply for robust data analysis to take place. Consistent guidelines are the basis of the proper protocol and ensuing standards to (a) reduce the time it takes data to reach those who are providing analysis; (b) allow them to better understand the energy storage installations; and (c) enable them to provide high-quality analysis of the installations. This report is intended to serve as a starting point for what data points should be provided when monitoring. As battery technologies continue to advance and the industry expands, this report will be updated to remain current.

25 ENERGY STORAGE↗

Revolutionizing Porous Liquids: Stabilization and Structural Engineering Achieved by a Surface Deposition Strategy

Facile approaches capable of constructing stable and structurally diverse porous liquids (PLs) that can deliver high-performance applications are a long-standing, captivating, and challenging research area that requires significant attention. Here, in this work, a facile surface deposition strategy is demonstrated to afford diverse type III-PLs possessing ultra-stable dispersion, external structure modification, and enhanced performance in gas storage and transformation by leveraging the expeditious and uniform precipitation of selected metal salts. The Ag(I) species-modified zeolite nanosheets are deployed as the porous host to construct type III-PLs with ionic liquids (ILs) containing bromide anion , leading to stable dispersion driven by the formation of AgBr nanoparticles. The as-afforded type-III PLs display promising performance in CO 2 capture/conversion and ethylene/ethane separation. Property and performance of the as-produced PLs can be tuned by the cation structure of the ILs, which can be harnessed to achieve polarity reversal of the porous host via ionic exchange. The surface deposition procedure can be further extended to produce PLs from Ba(II)-functionalized zeolite and ILs containing [SO 4 ] 2– anion driven by the formation of BaSO 4 salts. The as-produced PLs are featured by well-maintained crystallinity of the porous host, good fluidity and stability, enhanced gas uptake capacity, and attractive performance in small gas molecule utilization.

36 MATERIALS SCIENCE↗

Cost projections for Redox Energy storage systems

A preliminary design and system cost analysis was performed for the redox energy storage system. A conceptual design and cost estimate was prepared for each of two energy applications: (1) electric utility 100-MWh requirement (10-MW for ten hours) for energy storage for utility load leveling application, and (2) a 500-kWh requirement (10-kW for 50 hours) for use with a variety of residential or commercial applications, including stand alone solar photovoltaic systems. The conceptual designs were based on cell performance levels, system design parameters, and special material costs. These data were combined with estimated thermodynamic and hydraulic analysis to provide preliminary system designs. Results indicate that the redox cell stack to be amenable to mass production techniques with a relatively low material cost.

Michaels, K.↗

Topology Optimization of Curved Electrodes with Suggested Simplified Corrugated Designs

The demand for space-efficient energy storage, from grid to device scale, has soared with the rapid electrification of society. To increase energy density while maintaining high rate performance, shaping electrodes has been shown to be an effective strategy. Computational optimization can suggest designs that improve energy storage performance; however, generated designs are often complex, leading to manufacturing challenges. Additionally, most optimization is typically conducted in standard rectangular domains, whereas some applications, such as in the aerospace industry or in consumer electronics, may benefit from optimized electrodes that fit in a nonstandard form factor. Here, in this work, we use topology optimization to design capacitive full-cell electrodes in a curved domain. We propose a simplified corrugated electrode design based on the optimization results and show that the energy stored in the simplified design is only reduced by about 5–27% when compared to that in the fully optimized design, with more deviation occurring when ionic transport in the porous electrode is particularly impeded. Overall, we find that these simplified designs are promising, particularly given the more conventional manufacturing techniques required, and have a 42–369% increase in energy stored compared to monolithic electrodes.

Energy - Storage↗

Evaluating utility owned electric energy storage systems: a perspective for state electric utility regulators

This report provides a perspective on issues pertaining to the deployment of utility owned electrical energy storage. The intended audience includes state electric utility regulatory authorities, their staffs and the planning personnel in the utilities they regulate. Its purpose is to inform the audience about the potential opportunities for energy storage technologies to play a greater role in the evolving electricity marketplace and grid. The surge of investments in renewable energy (RE) during the last decade, particularly wind and solar energy has stimulated interest in energy storage. These technologies have the capability to balance the variability inherent in many RE technologies. The state public utility commissions’ (PUC) responsibility for regulating utilities leads to a focus on aspects of grid operations and expansion including: voltage and frequency regulation; distributed generation; renewable energy, particularly the administration of Renewable Portfolio Standards (RPS) mandates; and grid capital investment. Energy storage systems can contribute in each of these areas. Given the potential of energy storage technologies to perform these functions, their access to the regulatory process must be improved together with removal of barriers and appropriate and consistent cost benefit analysis methodologies so that they are routinely included in the suite of options considered for providing key grid services. The solutions that deliver the services cost effectively will likely be the solutions put forth by utilities and approved by utility commissions. Two storage system case studies are presented as a means to illustrate some of the fundamental valuation principles particularly pertinent to energy storage systems.

Bhatnagar, Dhruv↗

Time-Lapse Gravity Monitoring of CO2 Migration Based on Numerical Modeling of a Faulted Storage Complex

In this study, the performance of both surface and borehole time-lapse gravity monitoring to detect CO2 leakage from a carbon storage site is evaluated. Several hypothetical scenarios of CO2 migration in a leaky fault, and thief zones at different depths at the Kimberlina site (California, USA) constitute the basis of the approach. The CO2 displacement is simulated using the TOUGH2 simulator applied to a detailed geological model of the site. The gravity responses to these CO2 plumes are simulated using forward modeling with sensors at ground surface and in vertical boreholes. Results of inversion on one scenario are also presented. The surface-based gravity responses obtained for the different leakage scenarios demonstrate that leakage can be detected at the surface in all the scenarios but the time to detection is highly variable (10 to 40 years) and dependent on the detection threshold considered. Borehole measurements of the vertical component of gravity provide excellent constrains in depth when they are located in proximity of the density anomaly associated with the presence of CO2, thus discriminating multiple leaks in different thief zones. Joint inversion of surface and borehole data can bring valuable information of the occurrence of leakages and their importance by providing a reasonable estimate of mass of displaced fluids. This study demonstrates the importance of combining multiphase flow simulations with gravity modeling in order to define if and when gravity monitoring would be applicable at a given storage site.

Time-lapse gravity monitoring, leak detection, CCS↗

The effect of temperature, storage time and collection method on biomethane potential of source separated household food waste

Highlights: • Experiments to mimic storage of OFMSW performed in laboratory scale at 6 and 22 °C. • A recipe representative for OFMSW from households in Sweden was designed. • Clear signs of degradation for OFMSW stored at 22 °C with respect to time. • Higher loss of VS and H{sub 2}O for OFMSW in paper bags compared to plastic bags at 22 °C. - Abstract: The aim of this study was to mimic real conditions for storage and transport and to evaluate how much of the biomethane potential is lost before the organic fraction of municipal solid waste (OFMSW) from households in Sweden reaches the biogas plant. The laboratory biomethane potential (BMP) experiments was carried out with respect to the storage time, collection method (paper or plastic bag) and storage temperature (22 °C and 6 °C) in order to evaluate the effect of these factors on the biomethane potential. A recipe representative for OFMSW from households in Sweden was designed with the help of literature and modification of recipes from technical reports and scientific literature. Laboratory experiments showed that the difference in the BMP of OFMSW stored in plastic- compared to paper bags were obvious at 22 °C with a lower biomethane potential for paper bags, but there was no difference at 6 °C. Provided that the loss of organic matter during pre-treatment is equivalent for both paper and plastic bags it is possible to get more biomethane from OFMSW collected in plastic bags during the warmest part of the year, since they have a more preservative effect on OFMSW than paper bags. This could be explained by the plastic bags being denser than paper and therefore maintain the volatile organic compounds inside the bag and promote a pre-hydrolysis of the material rather than aerobic degradation.

09 BIOMASS FUELS↗

Spinach juice-derived porous Fe{sub 2}O{sub 3}/carbon nanorods as superior anodes for lithium-ion batteries

Graphical abstract: The table of contents entry: The Fe{sub 2}O{sub 3}/C nanocomposite is synthesized successfully by using green plant (spinach juice) as the carbon resource and soft template, which exhibits favorable specific capacity and excellent cycling stability. - Highlights: • The spinach juice serves as the carbon resource and soft template. • As-obtained nanorods are composed of Fe{sub 2}O{sub 3} and carbon with porous nature. • Rod-like Fe{sub 2}O{sub 3}/C exhibits good rate capability and cycling stability as LIB anode. - Abstract: A low-cost and green method to get electrode materials with wonderful electrochemical performance is decisive for the development of lithium ion batteries (LIBs). Here it’s the first time to synthesize rod-like porous Fe{sub 2}O{sub 3} coated with carbon (Fe{sub 2}O{sub 3}/C) by using biomolecules in spinach juice as soft templates and carbon resource. The different initial concentrations of Fe{sup 3+} can affect the morphologies and electrochemical properties of samples. When the initial concentration of Fe{sup 3+} is 0.4 M, the sample (Fe{sub 2}O{sub 3}/C-2) exhibits favorable performance of lithium storage owing to the existence of carbon with excellent electroconductivity and the porous rode-like structure which can relieve the large volume change and provide pathway for Li{sup +} transport during cycles. The initial capacity of sample is 1405 mA h g{sup −1} while the capacity maintained 581 mA h g{sup −1} after 100 cycles at a current density of 0.2 A g{sup −1}. The excellent electrochemical performances of Fe{sub 2}O{sub 3}/C-2 make it a promising anode material for LIBs.

36 MATERIALS SCIENCE↗

Development of High Performance and Sustainable Na-ion Batteries for Stationary Electrical Energy Storage

This report describes the status of advanced sodium-ion battery research being performed at Pacific Northwest National Laboratory for the U.S. Department of Energy’s Energy Storage Systems Program. The program will demonstrate a novel sodium-ion battery pouch cell with at least 50 mAh capacity capable of achieving $100/kWh projected materials cost at an energy retention > 80% over 250 cycles.

25 ENERGY STORAGE↗