Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Modeling of thermal processes in high pressure liquid chromatography. I. Low pressure onset of thermal heterogeneity

Heat due to viscous friction is generated in chromatographic columns. When these columns are operated at high flow rates, under a high inlet pressure, this heat causes the formation of significant axial and radial temperature gradients. Consequently, these columns become heterogeneous and several physico-chemical parameters, including the retention factors and the parameters of the mass transfer kinetics of analytes are no longer constant along and across the columns. A robust modeling of the distributions of the physico-chemical parameters allows the analysis of the impact of the heat generated on column performance. We developed a new model of the coupled heat and mass transfers in chromatographic columns, calculated the axial and radial temperature distributions in a column, and derived the distributions of the viscosity and the density of the mobile phase, hence of the axial and radial mobile phase velocities. The coupling of the mass and the heat balances in chromatographic columns was used to model the migration of a compound band under linear conditions. This process yielded the elution band profiles of analytes, hence the column efficiency under two different sets of experimental conditions: (1) the column is operated under natural convection conditions; (2) the column is dipped in a stream of thermostated fluid. The calculated results show that the column efficiency is remarkably lower in the second than in the first case. The inconvenience of maintaining constant the temperature of the column wall (case 2) is that retention factors and mobile phase velocities vary much more significantly across the column than if the column is kept under natural convection conditions (case 1).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative multiphase model for hydrothermal liquefaction of algal biomass

Here, optimized incorporation of hydrothermal liquefaction (HTL, reaction in water at elevated temperature and pressure) within an integrated biorefinery requires accurate models to predict the quantity and quality of all HTL products. Existing models primarily focus on biocrude product yields with limited consideration for biocrude quality and aqueous, gas, and biochar co-products, and have not been validated with an extensive collection of feedstocks. In this study, HTL experiments (300 °C, 30 min) were conducted using 24 different batches of microalgae feedstocks with distinctive feedstock properties, which resulted in a wide range of biocrude (21.3–54.3 dry weight basis, dw%), aqueous (4.6–31.2 dw%), gas (7.1–35.6 dw%), and biochar (1.3–35.0 dw%) yields. Based on these results, a multiphase component additivity (MCA) model was introduced to predict yields and characteristics of the HTL biocrude product and aqueous, gas, and biochar co-products, with only feedstock biochemical (lipid, protein, carbohydrate, and ash) and elemental (C/H/N) composition as model inputs. Biochemical components were determined to distribute across biocrude product/HTL co-products as follows: lipids to biocrude; proteins to biocrude > aqueous > gas; carbohydrates to gas ≈ biochar > biocrude; and ash to aqueous > biochar. Modeled quality indicators included biocrude C/H/N contents, higher heating value (HHV), and energy recovery (ER); aqueous total organic carbon (TOC) and total nitrogen (TN) contents; and biochar carbon content. The model was validated with HTL data from the literature, the potential to expand the application of this modeling framework to include waste biosolids (e.g., wastewater sludge, manure) was explored, and future research needs for industrial application were identified. Ultimately, the MCA model represents a critical step towards the integration of cultivation models with downstream HTL and biorefinery operations to enable system-level optimization, valorization of co-product streams (e.g., through catalytic hydrothermal gasification and nutrient recovery), and the navigation of tradeoffs across the value chain.

09 BIOMASS FUELS↗

Electrostatic and aerodynamic forced vibrations of a thin flexible electrode: Quasi-periodic vs. chaotic oscillations

In this paper, transverse vibrations of an electrostatically actuated thin flexible cantilever perturbed by low-speed air flow are studied using both experiments and numerical modeling. In the experiments, the dynamic characteristics of the cantilever are studied by supplying a DC voltage with an AC component for electrostatic forcing and a constant uniform air flow around the cantilever system for aerodynamic forcing. A range of control parameters leading to stable vibrations are established using a dimensionless operating parameter that is the ratio of the induced and the free stream velocities. Numerical results are validated with experimental data. Assuming the amplitude of vibrations are small, then a non-linear dynamic Euler-Bernoulli beam equation with viscous damping and gravitational effects is used to model the equation of motion. Aerodynamic forcing is modelled as a temporally sinusoidal and uniform force acting perpendicular to the beam length. The forcing amplitude is found to be proportional to the square of the air flow velocity. Numerical results strongly agree with the experiments predicting accurate vibration amplitude, displacement frequency, and quasi-periodic displacement of the cantilever tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PanDA Pilot Submission using Condor-G: Experience and Improvements

PanDA (Production and Distributed Analysis) is the workload management system of the ATLAS experiment, used to run managed production and user analysis jobs on the grid. As a late-binding, pilot-based system, the maintenance of a smooth and steady stream of pilot jobs to all grid sites is critical for PanDA operation. The ATLAS Computing Facility (ACF) at BNL, as the ATLAS Tier1 center in the US, operates the pilot submission systems for the US. This is done using the PanDA 'AutoPilot' scheduler component which submits pilot jobs via Condor-G, a grid job scheduling system developed at the University of Wisconsin-Madison. In this paper, we discuss the operation and performance of the Condor-G pilot submission at BNL, with emphasis on the challenges and issues encountered in the real grid production environment. With the close collaboration of Condor and PanDA teams, the scalability and stability of the overall system has been greatly improved over the last year. We review improvements made to Condor-G resulting from this collaboration, including isolation of site-based issues by running a separate Gridmanager for each remote site, introduction of the 'Nonessential' job attribute to allow Condor to optimize its behavior for the specific character of pilot jobs, better understanding and handling of the Gridmonitor process, as well as better scheduling in the PanDA pilot scheduler component. We will also cover the monitoring of the health of the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Multi-Tier Provenance Model for Global Climate Research

Global climate researchers rely upon many forms of sensor data and analytical methods to help profile subtle changes in climate conditions. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) program provides researchers with curated products called Value Added Products (VAPs) resulting from continuous instrumentation streams, data fusion, and analytical profiling. To provide these projects the ARM operations and research teams rely upon a number of techniques to ensure strict quality control and quality assurance codes are maintained. End users in the climate research community are highly interested in obtaining as much causal evidence as possible and currently either not all the evidence are easily attainable or easily identifiable without significant effort. Our research interests are to identify a provenance model that serves both the producers and consumers of the VAP maintaining the quality assurance/quality control standards and tailored to meeting the individual researcher’s needs.

54 ENVIRONMENTAL SCIENCES↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Selective evaporation of focusing fluid in two-fluid hydrodynamic print head.

The work performed in this project has demonstrated the feasibility to use hydrodynamic focusing of two fluid steams to create a novel micro printing technology for electronics and other high performance applications. Initial efforts focused solely on selective evaporation of the sheath fluid from print stream provided insight in developing a unique print head geometry allowing excess sheath fluid to be separated from the print flow stream for recycling/reuse. Fluid flow models suggest that more than 81 percent of the sheath fluid can be removed without affecting the print stream. Further development and optimization is required to demonstrate this capability in operation. Print results using two-fluid hydrodynamic focusing yielded a 30 micrometers wide by 0.5 micrometers tall line that suggests that the cross-section of the printed feature from the print head was approximately 2 micrometers in diameter. Printing results also demonstrated that complete removal of the sheath fluid is not necessary for all material systems. The two-fluid printing technology could enable printing of insulated conductors and clad optical interconnects. Further development of this concept should be pursued.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Sensor Arrays and Packaging

Novel sensor packaging elements were designed, fabricated, and tested in order to facilitate the transition of electrochemical mixed-potential sensors toward commercialization. Of the two designs completed, the first is currently undergoing field trials, taking direct measurements within vehicle exhaust streams, while the second is undergoing preliminary laboratory testing. The sensors’ optimal operating conditions, sensitivity to hydrogen, and long-­term baseline stability were also investigated. The sensing capabilities of lanthanum chromite (La 0.8 Sr 0.2 CrO 3 ) and indium-­doped tin oxide (ITO) working electrodes were compared, and the ITO devices were selected for pre-­commercial field trials testing at a hydrogen fuel cell vehicle fueling station in California. Previous data from that fueling station were also analyzed, and the causes of anomalous baseline drift were identified.

47 OTHER INSTRUMENTATION↗

An Overview of the Waste-to-Energy System Simulation (WESyS) Model

The leveraging of waste streams for energy and chemical production could add revenue to waste disposal operations, and it presents opportunities for addressing a variety of economic and environmental objectives at the local, state, and national levels. The Waste-to-Energy System Simulation (WESyS) model is a system dynamics model that was created to simulate the development of the U.S. waste-to-energy industry over time. For each of the three primary waste resources modeled (landfills, concentrated animal feeding operations, and publicly owned treatment works), WESyS simulates technically feasible scenarios for use of the waste, including direct conversion to fuels, and anaerobic digestion followed by flaring, electricity generation, combined heat and power, cleanup and compression to compressed natural gas, and cleanup and injection into an existing pipeline. The model allows users to explore numerous plausible future scenarios for the development of the U.S. waste-to-energy industry. This report provides an overview of the WESyS model and documents the key assumptions, equations, and data sources used to create the model.

09 BIOMASS FUELS↗

Technology in Focus: Power-to-X

Power-to-X is the process that converts electricity into energy carriers that can be used in industries and applications not connected to the electricity grid. By creating a product with direct process connected generation, contracted generation, or grid-delivered electricity that is in excess of current demand, production of electricity can be managed to time arbitrage energy and mitigate generation curtailment or inefficient operational reductions. In addition, creating a product potentially develops a secondary revenue stream that aids economics of the facility. This document is a high-level factsheet that provides an overview of what Power-to-X is and what it means.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laser velocimeter measurements in a large transonic wind tunnel

A two-component fringe type laser velocimeter operated in the backscatter mode was used to measure the free-stream velocity in an undisturbed flow field in a wind-tunnel test section from Mach 0.2 to Mach 1.0 and to measure the velocity along the stagnating streamline of a hemisphere model from Mach 0.2 to Mach 0.8. Burst signals from the laser velocimeter were processed by high-speed burst counters, and histograms of the number of occurrences of a particular counter output were collected by means of a pulse height analyzer. Arithmetic means of the histograms were calculated, and the results were compared with predicted local gas velocities with allowance for the lag of the scattering particles with respect to the gas flow. The free-stream measurements were accurate to within 2% of the calibration measurements. The stagnation streamline measurements show trends similar to theoretical predictions.

Meyers, J. F.↗

The effect of inflow velocity profiles on the performance of supersonic ejector nozzles

The design of supersonic nozzles is becoming increasingly complex as conflicting requirements for low noise, higher efficiency, and wider operating range are driving the designer toward more variable geometry and multiple stream flows. Analysis techniques must be modified and expanded to take into account these additional complexities and still retain the rapid computational rate necessary for optimization and design studies. A nozzle analysis must handle more flow streams, more complex geometries, and more highly distorted initial profiles. This paper discusses some modifications to a method for calculating the performance characteristics of supersonic ejector nozzles and demonstrates the improvement in results the modifications provide.

Bishop, A. R.↗

A review and analysis of boundary layer transition data for turbine application

A number of data sets from the open literature that include heat transfer data in apparently transitional boundary layers, with particular application to the turbine environment, were reviewed and analyzed to extract transition information. The data were analyzed by using a version of the STAN5 two-dimensional boundary layer code. The transition starting and ending points were determined by adjusting parameters in STAN5 until the calculations matched the data. The results are presented as a table of the deduced transition location and length as functions of the test parameters. The data sets reviewed cover a wide range of flow conditions, from low-speed, flat-plate tests to full-scale turbine airfoils operating at simulated turbine engine conditions. The results indicate that free-stream turbulence and pressure gradient have strong, and opposite, effects on the location of the start of transition and on the length of the transition zone.

Gaugler, R. E.↗

Effects of a Scanning Reflectarray Antenna on Modulated Data Modeled

The ferroelectric reflectarray is a new type of scanning antenna under development for space and ground communications and radar applications at the NASA Glenn Research Center. The reflectarray offers tremendous cost, gain, and efficiency advantages in comparison to the state-of-the-art phased arrays, but there is an inherent intersymbol interference (ISI) problem with digital communication data streams processed through the array because of the way the reflectarray is operated. This interference stems from the fact that the antenna beam is formed by the superposition of reflected waves from the array elements. The delays from the elements to the observation point of each wave differ. Ferroelectric phase shifters are designed to compensate for the modulo-2p phase differences so that the waves will constructively interfere at the sinusoidal carrier level; however, the delays of the integer-number multiple of the carrier period are not compensated for. This lack of compensation causes ISI in digital modulated signals. ISI has not been a problem with analog modulations and low-rate digital modulations since the distortion (or ISI) introduced is negligible. The problem becomes acute when the data rate gets higher, and the electrical size of the array gets bigger. Moreover, there are intrinsic transient effects associated with the phase shifters and the controller that executes the algorithm to direct the beam. That is, phase shifter updates to redirect the beam may be initiated simultaneously, but nonlinearity will cause different settling times. The ISI problem and other effects ultimately limit the size (gain) and data rate of the reflectarray. An ISI analysis was required to prove or disprove the suitability of the reflectarray antenna for high-rate digitally modulated signals and to give guidance for determining antenna parameters. In this research, the nature of the ISI of the reflectarray has been mathematically modeled.

Romanofsky, Robert R.↗

CFD Models of a Serpentine Inlet, Fan, and Nozzle

Several computational fluid dynamics (CFD) codes were used to analyze the Versatile Integrated Inlet Propulsion Aerodynamics Rig (VIIPAR) located at NASA Glenn Research Center. The rig consists of a serpentine inlet, a rake assembly, inlet guide vanes, a 12-in. diameter tip-turbine driven fan stage, exit rakes or probes, and an exhaust nozzle with a translating centerbody. The analyses were done to develop computational capabilities for modeling inlet/fan interaction and to help interpret experimental data. Three-dimensional Reynolds averaged Navier-Stokes (RANS) calculations of the fan stage were used to predict the operating line of the stage, the effects of leakage from the turbine stream, and the effects of inlet guide vane (IGV) setting angle. Coupled axisymmetric calculations of a bellmouth, fan, and nozzle were used to develop techniques for coupling codes together and to investigate possible effects of the nozzle on the fan. RANS calculations of the serpentine inlet were coupled to Euler calculations of the fan to investigate the complete inlet/fan system. Computed wall static pressures along the inlet centerline agreed reasonably well with experimental data but computed total pressures at the aerodynamic interface plane (AIP) showed significant differences from the data. Inlet distortion was shown to reduce the fan corrected flow and pressure ratio, and was not completely eliminated by passage through the fan

Chima, R. V.↗

Downlink Data Multiplexer

A multiplexer/demultiplexer system has been developed to enable the transmission, over a single channel, of four data streams generated by a variety of sources at different (including variable) bit rates. In the original intended application, replicas of this multiplexer/demultiplexer system would be incorporated into the spacecraft-to-ground communication systems of the space shuttles. The multiplexer of each system would be installed in the spacecraft, where it would acquire and process data from such sources as commercial digital camcorders, video tape recorders, and the spacecraft telemetry system. The demultiplexer of each system would be installed in a ground station. Purely terrestrial systems of similar design could be attractive for use in situations in which there are requirements to transmit multiple streams of high-quality video data and possibly other data over single channels. The figure is a block diagram of the multiplexer as configured to process data received via three fiber-optic channels like those of the International Space Station and one electrical-cable channel that conforms to the Institute of Electrical and Electronic Engineers (IEEE) 1394 standard. (This standard consists of specifications of a high-speed serial data interface, the physical layer of which includes a cable known in the art as "FireWire." An IEEE 1394 interface can also transfer power between the components to which it is connected.) The fiber-optic channels carry packet and/or bit-stream signals that conform to the standards of the Consultative Committee for Space Data Systems (CCSDS). The IEEE 1394 interface accepts an isochronous signal like that from a digital camcorder or a video tape recorder. The processing of the four input data streams to combine them into one output stream is governed by a statistical multiplexing algorithm that features a flow-control capability and makes it possible to utilize the transmission channel with nearly 100-percent efficiency. This algorithm allocates the available bandwidth of the transmission channel to the data streams according to a combination of data rates and preassigned priorities. Incoming data streams that demand too much bandwidth are blocked. Bandwidth not needed for a transmission of a given data stream is allocated to other streams as available. Priority is given to the IEEE 1394 stream. In addition to the four incoming data streams, the multiplexer transmits data on the status of the system. An operator can monitor and control the multiplexer via displays and controls on the multiplexer housing. The output of the multiplexer is connected via a coaxial cable with an impedance of 50 Ohms to an interface circuit compatible with the space-shuttle high-speed digital downlink, which operates at a rate of 48 Mb/s.

Holland, Douglas↗

Large-Eddy Simulation of Variable Speed Power Turbine Cascade with Inflow Turbulence

Numerical results are presented from theNASAGlenn Research Center’sin-house turbomachinery code, Glenn-HT applied to the Variable Speed Power Turbine (VSPT) experiment at the NASA Transonic Turbine Blade Cascade Facility.The main goal of this paper is to implement a digital filtering method to generate turbulence upstream and a sub-grid model (Localized dynamic k-equation model (LDKM)) in the framework of LES in order to investigate the effect of inflow turbulence on the transition seen in the VSPT experimental data at the cruise condition (incidence angle of 40oand Tu = 0.5%, 5%,10%, and 15%). Although the boundary layer on thesuction side and pressure side of the blades is initially laminar due to favorable pressure gradient, the laminar flow can transition to turbulent flow past a separation zoneon the suction sideor by natural or by-pass transition. This process determinesthe total-pressure lossesin the wake. Therefore, it is desirable to develop a reliable prediction tool to accurately capture the transition mechanism in blade rows operated under the conditions of low Reynolds number andat a variety offree stream turbulence conditions. Our numerical studies reveal that the location of separationis rather insensitive to the level of Tu, however the effect ofincreasingTu seems to be in reducing the size and ultimately suppressing the separation bubble. In addition, we performedspectral analysis to identify the peak frequencies in the region where the separation bubble is formed, which provides valuable insights into the transition/separation mechanism.

CFD↗

SLUDGE RETRIEVAL FROM HANFORD K WEST BASIN SETTLER TANKS

In 2010, an innovative, remotely operated retrieval system was deployed to successfully retrieve over 99.7% of the radioactive sludge from ten submerged tanks in Hanford's K-West Basin. As part of K-West Basin cleanup, the accumulated sludge needed to be removed from the 0.5 meter diameter by 5 meter long settler tanks and transferred approximately 45 meters to an underwater container for sampling and waste treatment. The abrasive, dense, non-homogeneous sludge was the product of the washing process of corroded nuclear fuel. It consists of small (less than 600 micron) particles of uranium metal, uranium oxide, and various other constituents, potentially agglomerated or cohesive after 10 years of storage. The Settler Tank Retrieval System (STRS) was developed to access, mobilize and pump out the sludge from each tank using a standardized process of retrieval head insertion, periodic high pressure water spray, retraction, and continuous pumping of the sludge. Blind operations were guided by monitoring flow rate, radiation levels in the sludge stream, and solids concentration. The technology developed and employed in the STRS can potentially be adapted to similar problematic waste tanks or pipes that must be remotely accessed to achieve mobilization and retrieval of the sludge within.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗