Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface modifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

rf plasma system as an atomic oxygen exposure facility

The materials of spacecraft external surfaces in low Earth orbit (LEO) are exposed to the various constituents of the space environment, including atomic oxygen (AO) and solar ultra violet (UV) radiation. Material degradation and erosion by LEO are simulated in ground laboratories using a variety of experimental facilities, each with their respective limitations. rf oxygen plasma is a simulation facility widely used for materials screening for LEO application. However, the complex plasma environment, which contains, in addition to the neutral oxygen atoms, excited species, electrons, and ions as well as vacuum ultraviolet (VUV) radiation, might lead to erroneous determination of materials reactivity with respect to LEO. This paper describes the development of a simple, low cost rf plasma system to produce a well-defined AO and VUV environment. The new system constrained the afterglow flow through two right-angle turns. The afterglow was characterized at three specific locations by (i) optical emission spectroscopy for assessment of electronically excited states, (ii) current measurements, and (iii) UV radiation measurements. Kapton registered samples were exposed at the three specific locations in the system and characterized by mass loss for etch rate evaluation, and atomic force microscopy for surface modification. It was found that there is a significant reduction in ionic species, excited species, and UV radiation as the afterglow advances through the right-angle turns. The reduction in charged particle flux is due to recombination within the afterglow as well as neutralization by colliding with the grounded metal chamber walls; similar decrease in UV radiation flux occurs through radiation absorption by the chamber walls. Finally, it is shown that the ground state AO is the dominant reactive specie of the plasma afterglow after passing through the two right-angle turns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Beam Measurements of a Dense Plasma Focus Device Using CR 39 Nuclear Track Detectors

The project is carried out using a small Mather type plasma focus device powered by a 15 kV, 30 {mu}F capacitor. The filling gas used is argon. The ion beam generated is investigated by both time resolved and time integrated methods. Investigation on the dynamic of the current sheath is also carried out in order to obtain an optimum condition for ion beam production. The angular distribution of the ion emission is measured at positions of 0 deg. (end-on), 45 deg. and 90 deg. (side-on) by using CR-39 nuclear track detectors. The divergence of the ion beam is also determined using these detectors. A biased ion collector is used for time resolved measurement of the ion beam. Time of flight technique is employed for the determination of the ion beam energy. Average ion beam energy obtained is about 180 keV. The ion beam produced can be used for applications such as material surface modification and ion implantation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser induced popcornlike conformational transition of nanodiamond as a nanoknife

Nanodiamond (ND) is surrounded by layers of graphite on its surface. This unique structure feature creates unusual fluorescence spectra, which can be used as an indicator to monitor its surface modification. Meanwhile, the impurity, nitroso (C-N=O) inside the ND can be photolyzed by two-photon absorption, releasing NO to facilitate the formation of a sp{sup 3} diamond structure in the core of ND and transforming it into a sp{sup 2} graphite structure. Such a conformational transition enlarges the size of ND from 8 to 90 nm, resulting in a popcornlike structure. This transition reaction may be useful as nanoknives in biomedical application.

36 MATERIALS SCIENCE↗

Diagnosis of high-intensity pulsed heavy ion beam generated by a novel magnetically insulated diode with gas puff plasma gun

Intense pulsed heavy ion beam is expected to be applied to materials processing including surface modification and ion implantation. For those applications, it is very important to generate high-purity ion beams with various ion species. For this purpose, we have developed a new type of a magnetically insulated ion diode with an active ion source of a gas puff plasma gun. When the ion diode was operated at a diode voltage of about 190 kV, a diode current of about 15 kA, and a pulse duration of about 100 ns, the ion beam with an ion current density of 54 A/cm{sup 2} was obtained at 50 mm downstream from the anode. By evaluating the ion species and the energy spectrum of the ion beam via a Thomson parabola spectrometer, it was confirmed that the ion beam consists of nitrogen ions (N{sup +} and N{sup 2+}) of energy of 100-400 keV and the proton impurities of energy of 90-200 keV. The purity of the beam was evaluated to be 94%. The high-purity pulsed nitrogen ion beam was successfully obtained by the developed ion diode system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4D Density Determination of NH Radicals in an MSE Microplasma Combining Planar Laser Induced Fluorescence and Cavity Ring-Down Spectroscopy

An application of microplasmas is surface modification under mild conditions and of small, well defined areas. For this, an understanding of the plasma composition is of importance. First results of our work on the production and detection of NH radicals in a capacitively coupled radio frequency (RF) microplasma are presented. A microstructured comb electrode was used to generate a glow discharge in a hydrogen/nitrogen gas mixture by applying 13.56 MHz RF voltage. The techniques of planar laser induced fluorescence (PLIF) and cavity ring-down spectroscopy (CRDS) are used for space and time resolved, quantitative detection of the NH radical in the plasma. The rotational temperature was determined to be 820 K and, the density 5.1x10{sup 12} cm{sup 3}. Also, time dependent behaviour of the NH production was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling and Simulation of the Advanced Plasma Source

Plasma ion assisted-deposition (PIAD) is a combination of conventional thermal evaporation deposition and plasma-beam surface modification; it serves as a well-established technology for the creation of high quality coatings on mirrors, lenses, and other optical devices. It is closely related to ion-assisted deposition to the extent that electrons preserve quasineutrality of the ion beam. This paper investigates the Advanced Plasma Source (APS), a plasma beam source employed for PIAD. A field enhanced glow discharge generates a radially expanding plasma flow with an ion energy of about 80-120 eV. Charge exchange collisions with the neutral background gas (pressure 0.1 Pa and below) produce a cold secondary plasma, which expands as well. A model is developed which describes the primary ions by a simplified Boltzmann equation, the secondary ions by the equations of continuity and momentum balance, and the electrons by the condition of Boltzmann equilibrium. Additionally, quasineutrality is assumed. The model can be reduced to a single nonlinear differential equation for the velocity of the secondary ions, which has several removable singularities and one essential singularity, identified as the Bohm singularity. Solving the model yields macroscopic plasma features, such as fluxes, densities, and the electrical field. An add-on Monte-Carlo simulation is employed to calculate the ion energy distribution function at the substrate. All results compare well to experiments conducted at a commercial APS system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron-beam direct processing on living cell membrane

We demonstrated a direct processing on a living Hep G2 cell membrane in conventional cultivation conditions using an electron beam. Electron beam-induced deposition from liquid precursor 3,4-ethylenedioxythiophene and ablation was performed on the living cells. The 2.5-10 keV electron beam which was irradiated through a 100-nm-thick SiN nanomembrane could induce a deposition pattern and a ablation on a living cell membrane. This electron beam direct processing can provide simple in-situ cell surface modification for an analytical method of living cell membrane dynamic.

60 APPLIED LIFE SCIENCES↗

Textured Nd2Fe14B flakes with enhanced coercivity

Morphology, structure, and magnetic properties of the [001] textured Nd2Fe14B nanocrystalline flakes prepared by surfactant-assisted high energy ball milling (HEBM) and subsequent annealing were studied. These flakes have a thickness of 80-200 nm, a length of 0.5-10 mu m, and an average grain size of 10-14nm. The addition of some amount of Dy, Nd70Cu30 alloy, and an appropriate post annealing increased the coercivity H-i(c) of the Nd2Fe14B flakes. iHc was 3.7, 4.3, and 5.7 kOe for the Nd15.5Fe78.5B6, Nd14Dy1.5Fe78.5B6 and 83.3wt.% Nd14Dy1.5Fe78.5B6+16.7 wt.% Nd70Cu30 flakes prepared by HEBM for 5 h in heptane with 20 wt.% oleylamine, respectively. After annealing at 450 degrees C for 0.5h, their iHc increased to 5.1, 6.2, and 7.0 kOe, respectively. Anisotropic magnetic behavior was found in all of the as-milled and annealed flakes. Both, the thickening of Nd-rich phase at grain boundaries via diffusion of Nd70Cu30 and the surface modification of the Nd2Fe14B flake could be the main reasons for the coercivity enhancement in the as-milled and annealed Nd70Cu30-added Nd2Fe14B flakes. (C) 2012 American Institute of Physics. [doi: 10.1063/1.3679425]

Cui, BZ↗

Performance enhancement of organic light-emitting diodes by chlorine plasma treatment of indium tin oxide

The characteristics of green phosphorescent organic light-emitting diodes (OLEDs) fabricated on ITO/glass substrates pretreated with low-energy O{sub 2} and Cl{sub 2} plasma were compared. At 20 mA/cm{sup 2}, the OLEDs with O{sub 2} and Cl{sub 2} plasma-treated indium tin oxide (ITO) had voltages of 9.6 and 7.6 eV, and brightness of 9580 and 12380 cd/m{sup 2}, respectively. At {approx}10{sup 4} cd/m{sup 2}, the latter had a 30% higher external quantum efficiency and a 74% higher power efficiency. Photoelectron spectroscopies revealed that Cl{sub 2} plasma treatment created stable In-Cl bonds and raised the work function of ITO by up to 0.9 eV. These results suggest that the better energy level alignment at the chlorinated ITO/organic interface enhances hole injection, leading to more efficient and more reliable operation of the OLEDs. The developed plasma chlorination process is very effective for surface modification of ITO and compatible with the fabrication of various organic electronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma electron source for the generation of wide-aperture pulsed beam at forevacuum pressures

This article reports on design and application of wide-aperture pulsed beam source, based on hollow cathode discharge. The source is intended for electron beam generation in pressure range 2-15 Pa. Multi-aperture extraction system, used in a source, provided beam cross-section uniformity of 10% on diameter 40 mm. The limiting values of the current density, pulse duration, and accelerating voltage are 350 mA/cm{sup 2}, 250 {mu}s, and 10 kV, respectively. These parameters are sufficient for surface modification of various materials, including non-conducting matters.

43 PARTICLE ACCELERATORS↗

Laser-induced breakdown spectroscopy of tantalum plasma

Laser Induced Breakdown spectroscopy (LIBS) of Tantalum (Ta) plasma has been investigated. For this purpose Q-switched Nd: YAG laser pulses (λ∼ 1064 nm, τ∼ 10 ns) of maximum pulse energy of 100 mJ have been employed as an ablation source. Ta targets were exposed under the ambient environment of various gases of Ar, mixture (CO{sub 2}: N{sub 2}: He), O{sub 2}, N{sub 2}, and He under various filling pressure. The emission spectrum of Ta is observed by using LIBS spectrometer. The emission intensity, excitation temperature, and electron number density of Ta plasma have been evaluated as a function of pressure for various gases. Our experimental results reveal that the optical emission intensity, the electron temperature and density are strongly dependent upon the nature and pressure of ambient environment. The SEM analysis of the ablated Ta target has also been carried out to explore the effect of ambient environment on the laser induced grown structures. The growth of grain like structures in case of molecular gases and cone-formation in case of inert gases is observed. The evaluated plasma parameters by LIBS analysis such as electron temperature and the electron density are well correlated with the surface modification of laser irradiated Ta revealed by SEM analysis.

36 MATERIALS SCIENCE↗

A room temperature electron cyclotron resonance ion source for the DC-110 cyclotron

The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intensive Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. This article reviews the design and construction of DECRIS-5 ion source along with some initial commissioning results.

43 PARTICLE ACCELERATORS↗

Self-standing elastomeric composites based on lithium ferrites and their dielectric behavior

Lithium ferrite (LiFe{sub 5}O{sub 8}) is an attractive material for technological applications due to its physical properties, which are significantly dependent on the preparation method and raw materials. In this work, LiFe{sub 5}O{sub 8} crystallites were obtained by controlled heat-treatment process at 1100 °C, of a homogeneous mixture of Li{sub 2}O-Fe{sub 2}O{sub 3} powders, prepared by wet ball-milling and using lithium and iron nitrates as raw materials. The main goal was the preparation of a flexible and self-standing tick composite film by embedding lithium ferrite particles in a polymeric matrix, taking advantage of the good mechanical properties of the polymer and of the electrical and dielectric properties of the ferrite. The selected polymer matrix was styrene-b-isoprene-b-styrene copolymer. To prepare the composites, the lithium ferrite particles were chemically modified in order to functionalize their surface. To analyse the influence of the particles surface modification, different composites were made, with modified and unmodified particles. The structure of the obtained composites was studied by FTIR, XRD, TGA, and DSC techniques. The dielectric properties were analysed, in the frequency range between 10 Hz and 1 MHz and in function of temperature in the range between −73 °C and 127 °C. These properties were related with the structure and concentration of the particles in the matrix network. The composites with the modified particles present higher dielectric constant, maintaining values of loss tangent sufficiently low (<10{sup −2}) that can be considered interesting for technological applications.

36 MATERIALS SCIENCE↗

Plasma acceleration using a radio frequency self-bias effect

In this work plasma acceleration using a RF self-bias effect is experimentally studied. The experiments are conducted using a novel plasma accelerator system, called Neptune, consisting of an inductively coupled plasma source and a RF-biased set of grids. The plasma accelerator can operate in a steady state mode, producing a plasma flow with separately controlled plasma flux and velocity without any magnetic configuration. The operating pressure at the source output is as low as 0.2 mTorr and can further be decreased. The ion and electron flows are investigated by measuring the ion and electron energy distribution functions both space resolved and with different orientations with respect to the flow direction. It is found that the flow of electrons from the source is highly anisotropic and directed along the ion flow and this global flow of accelerated plasma is well localized in the plasma transport chamber. The maximum flux is about 7.5·10{sup 15} ions s{sup −1} m{sup −2} (at standard conditions) on the axis and decreasing to almost zero at a radial distances of more than 15 cm from the flow axis. Varying the RF acceleration voltage in the range 20–350 V, the plasma flow velocity can be changed between 10 and 35 km/s. The system is prospective for different technology such as space propulsion and surface modification and also interesting for fundamental studies for space-related plasma simulations and investigation of the dynamo effect using accelerated rotating plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The influence of MoO{sub x} gap states on hole injection from aluminum doped zinc oxide with nanoscale MoO{sub x} surface layer anodes for organic light emitting diodes

The effective workfunction of Al doped ZnO films (AZO) increased from 4.1 eV to 5.55 eV after surface modification with nanoscale molybdenum sub-oxides (MoO{sub x}). Hole only devices with anodes consisting of 3 nm of MoO{sub x} on AZO exhibited a lower turn-on voltage (1.5 vs 1.8 V), and larger charge injection (190 vs 118 mA/cm{sup 2}) at the reference voltage, compared to indium tin oxide (ITO). AZO devices with 10 nm of MoO{sub x} exhibited the highest workfunction but performed poorly compared to devices with 3 nm of MoO{sub x}, or standard ITO. Ultraviolet photoelectron, X-ray photoelectron, and optical spectroscopies indicate that the 3 nm MoO{sub x} films are more reduced and farther away from MoO{sub 3} stoichiometry than their 10 nm equivalents. The vacancies associated with non-stoichiometry result in donor-like gap states which we assign to partially occupied Mo 4d levels. We propose that Fowler-Nordheim tunneling from these levels is responsible for the reduction in threshold voltage measured in devices with 3 nm of MoO{sub x}. A schematic band diagram is proposed. The thicker MoO{sub x} layers are more stoichiometric and resistive, and the voltage drop across these layers dominates their electrical performance, leading to an increase in threshold voltage. The results indicate that AZO with MoO{sub x} layers of optimal thickness may be potential candidates for anode use in organic light emitting diodes.

36 MATERIALS SCIENCE↗

Boron ion beam generation utilizing lanthanum hexaboride cathodes: Comparison of vacuum arc and planar magnetron glow

Boron ion beams are widely used for semiconductor ion implantation and for surface modification for improving the operating parameters and increasing the lifetime of machine parts and tools. For the latter application, the purity requirements of boron ion beams are not as stringent as for semiconductor technology, and a composite cathode of lanthanum hexaboride may be suitable for the production of boron ions. We have explored the use of two different approaches to boron plasma production: vacuum arc and planar high power impulse magnetron in self-sputtering mode. For the arc discharge, the boron plasma is generated at cathode spots, whereas for the magnetron discharge, the main process is sputtering of cathode material. We present here the results of comparative test experiments for both kinds of discharge, aimed at determining the optimal discharge parameters for maximum yield of boron ions. For both discharges, the extracted ion beam current reaches hundreds of milliamps and the fraction of boron ions in the total extracted ion beam is as high as 80%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of thermal annealing on the redistribution of alkali metals in Cu(In,Ga)Se 2 solar cells on glass substrate

The precise control of alkali-metal concentrations in Cu(In,Ga)Se 2 (CIGS) solar cells via post deposition treatment (PDT) has recently attracted attention. When PDT is performed at an elevated temperature, an accompanying annealing effect is expected. Here, we investigate how thermal annealing affects the redistribution of alkali metals in CIGS solar cells on glass substrates and the properties of the solar cells. In addition, we investigate the origin of non-homogeneous alkali-metal depth profiles that are typical of CIGS grown using a three-stage process. In particular, we use secondary-ion mass spectrometry measurements of the ion concentration as a function of distance from the CIGS surface to investigate the impact of thermal annealing on the distribution of alkali metals (Na, Ka, and Rb) and constituent elements (Ga and In) in the CIGS absorbers. We find that the depth profiles of the alkali metals strongly reflect the density of sites that tend to accommodate alkali metals, i.e., vacancies. Annealing at elevated temperature caused a redistribution of the alkali metals. The thermal-diffusion kinetics of alkali metals depends strongly on the species involved. We introduced low flux potassium fluoride (KF) to study a side effect of KF-PDT, i.e., Na removal from CIGS, separately from its predominant effects such as surface modification. When sufficient amounts of Na are supplied from the soda lime glass via annealing at an elevated temperature, the negative effect was not apparent. Conversely, when the Na supply was not sufficient, it caused a deterioration of the photovoltaic properties.

14 SOLAR ENERGY↗

Demonstration of waferscale voltage amplifier and electrostatic quadrupole focusing array for compact linear accelerators

Compact linear accelerators, with beam energies in the kiloelectron volt to megaelectron volt range, have applications in medicine, neutron/X-ray generation, surface modifications, etc. The size, weight, and power of existing accelerators preclude them from mass availability in portable formats. This paper presents a specific implementation of an ion accelerator architecture based on planar wafers with accelerating and focusing sections. Our low cost approach allows the control of the final ion beam energy with potential applications, for example, for accelerator-based ion implantation. In this paper, we demonstrate two important waferscale modules required to build a linear particle accelerator; these include (1) on-wafer voltage amplification for beam acceleration using Inductor-Capacitor (LC) resonators and (2) waferscale electrostatic quadrupole arrays (ESQA) to refocus the ion beams during transport. On-board LC resonators were developed using Printed Circuit Board fabrication processes to implement an LC element resonant at ~ 16.6 MHz with a quality factor of 25. An energy gain of ~ 250 eV was observed using a two wafer acceleration unit with an argon ion beam with 6.5 keV initial energy. A 3 × 3 ESQA was fabricated on a glass wafer with metal electrodes formed by depositing copper metal around the beam apertures. The ESQA was used to focus and defocus an argon ion beam, demonstrating a field gradient of ~ 500 V over a gap of ~ 250 μm.

43 PARTICLE ACCELERATORS↗