Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Multi-Task Learning of Scanning Electron Microscopy and Synthetic Thermal Tomography Images for Detection of Defects in Additively Manufactured Metals

One of the key challenges in laser powder bed fusion (LPBF) additive manufacturing of metals is the appearance of microscopic pores in 3D-printed metallic structures. Quality control in LPBF can be accomplished with non-destructive imaging of the actual 3D-printed structures. Thermal tomography (TT) is a promising non-contact, non-destructive imaging method, which allows for the visualization of subsurface defects in arbitrary-sized metallic structures. However, because imaging is based on heat diffusion, TT images suffer from blurring, which increases with depth. We have been investigating the enhancement of TT imaging capability using machine learning. In this work, we introduce a novel multi-task learning (MTL) approach, which simultaneously performs the classification of synthetic TT images, and segmentation of experimental scanning electron microscopy (SEM) images. Synthetic TT images are obtained from computer simulations of metallic structures with subsurface elliptical-shaped defects, while experimental SEM images are obtained from imaging of LPBF-printed stainless-steel coupons. MTL network is implemented as a shared U-net encoder between the classification and the segmentation tasks. Results of this study show that the MTL network performs better in both the classification of synthetic TT images and the segmentation of SEM images tasks, as compared to the conventional approach when the individual tasks are performed independently of each other.

36 MATERIALS SCIENCE↗

Joint iterative reconstruction and 3D rigid alignment for X-ray tomography

X-ray tomography is widely used for three-dimensional structure determination in many areas of science, from the millimeter to the nanometer scale. The resolution and quality of the 3D reconstruction is limited by the availability of alignment parameters that correct for the mechanical shifts of the sample or sample stage for the images that constitute a scan. In this paper we describe an algorithm for marker-free, fully automated and accurately aligned and reconstructed X-ray tomography data. Our approach solves the tomographic reconstruction jointly with projection data alignment based on a rigid-body deformation model. We demonstrate the robustness of our method on both synthetic phantom and experimental data and show that our method is highly efficient in recovering relatively large alignment errors without prior knowledge of a low resolution approximation of the 3D structure or a reasonable estimate of alignment parameters.

36 MATERIALS SCIENCE↗

Plasmonic Three-Dimensional Transparent Conductor Based on Al-Doped Zinc Oxide-Coated Nanostructured Glass Using Atomic Layer Deposition

Transparent nanostructured glass coatings, fabricated on glass substrates, with a unique three-dimensional (3D) architecture were utilized as the foundation for the design of plasmonic 3D transparent conductors. Transformation of the non-conducting 3D structure to a conducting 3D network was accomplished through atomic layer deposition of aluminum-doped zinc oxide (AZO). After AZO growth, gold nanoparticles (AuNPs) were deposited by electronbeam evaporation to enhance light trapping and decrease the overall sheet resistance. Field emission scanning electron microscopy and atomic force microcopy images revealed the highly porous, nanostructured morphology of the AZO coated glass surface along with the in-plane dimensions of the deposited AuNPs. Sheet resistance measurements conducted on the coated samples verified that the electrical properties of the 3D network are comparable to that of the untextured two-dimensional AZO coated glass substrates. In addition, transmittance measurements of the glass samples coated with various AZO thicknesses showed preservation of the highly transparent nature of each sample, while the AuNPs demonstrated enhanced light scattering as well as light-trapping capability.

36 MATERIALS SCIENCE↗

Pushing the limits: Resolving paleoseawater signatures in nanoscale fluid inclusions by atom probe tomography

New insight into the geochemistry of ancient environments can be gained through structural and chemical analyses of nanometer-scale features within minerals. Here, we present recent developments using atom probe tomography (APT) enabling direct visualization of nanoscale fluid inclusions trapped within pyrite (FeS 2 ) and thereby chemical characterization of remnant seawater. Pyrite framboids (spherical clusters of nanocrystals) were sampled from the Middle Devonian Leicester Pyrite Member (New York). Scanning transmission electron microscopy shows low density regions distributed within the pyrite consistent with nanoscale pores (<4 nm in size). APT 3D visualization and compositional mapping reveals that the nanopores are filled with water. The inclusions appear to preserve the elemental signature of the water column in which the framboids formed, specifically seawater components including Na, K, Mg, and Ca. Mg/Ca ratios within the pyrite were generally measured to be within 0.6±0.2 – consistent with calcite-dominated seawater conditions existing in the Middle Devonian. Furthermore, this study demonstrates the potential for a novel approach to reconstruct paleoenvironmental conditions from coupled elemental and structural analyses of nanoscale fluid inclusions.

54 ENVIRONMENTAL SCIENCES↗

Bridging microscopy with molecular dynamics and quantum simulations: an atomAI based pipeline

Recent advances in (scanning) transmission electron microscopy have enabled a routine generation of large volumes of high-veracity structural data on 2D and 3D materials, naturally offering the challenge of using these as starting inputs for atomistic simulations. In this fashion, the theory will address experimentally emerging structures, as opposed to the full range of theoretically possible atomic configurations. However, this challenge is highly nontrivial due to the extreme disparity between intrinsic timescales accessible to modern simulations and microscopy, as well as latencies of microscopy and simulations per se. Addressing this issue requires as a first step bridging the instrumental data flow and physics-based simulation environment, to enable the selection of regions of interest and exploring them using physical simulations. Here we report the development of the machine learning workflow that directly bridges the instrument data stream into Python-based molecular dynamics and density functional theory environments using pre-trained neural networks to convert imaging data to physical descriptors. Additionally, the pathways to ensure structural stability and compensate for the observational biases universally present in the data are identified in the workflow. This approach is used for a graphene system to reconstruct optimized geometry and simulate temperature-dependent dynamics including adsorption of Cr as an ad-atom and graphene healing effects. However, it is universal and can be used for other material systems.

36 MATERIALS SCIENCE↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗

3D Printing with Mixed Powders of Boron Carbide and Al Alloy

Laser additive manufacturing with mixed powders of boron carbide and aluminum alloy is investigated. Parameters such as laser power, scan speed, scan pattern, and hatching space are systematically evaluated and optimized to obtain the desired density and porosity. These results show that the AM part contains 20 wt% boron carbide and 80 wt% aluminum alloy, which are well mixed and synthesized during the melting process. Its mechanical properties are close to those of aluminum. A thin-wall structure based two dimensional and three dimensional radial collimators were fabricated with well-controlled geometry for neutron scattering measurement.

36 MATERIALS SCIENCE↗

Additively Manufactured Carbon Fiber-Reinforced Siliconized Silicon Carbide Composites Using Carbon Fiber-Reinforced Poly-Ether-Ether-Ketone (PEEK) as a Precursor

Herein, we report a method to additively manufacture carbon fiber-reinforced siliconized silicon carbide composites. The process involves the pyrolysis of a 3D-printed carbon fiber-reinforced poly-ether-ether-ketone (PEEK) composite to produce a porous carbon fiber-reinforced carbon matrix composite preform, which is subsequently infiltrated with molten silicon to obtain a carbon fiber-reinforced siliconized silicon carbide composite. A key aspect of the method is limiting polymer melt flow during pyrolysis of PEEK, which is achieved by thermally annealing the 3D-printed carbon fiber-reinforced PEEK preform in air at a temperature below PEEK’s melting temperature. Rheological and differential scanning calorimetry (DSC) measurements demonstrate that the thermal annealing treatment altered the melting behavior of PEEK, while NMR and FTIR measurements provided a mechanistic explanation for the structural changes responsible for the behavior. It was also found that dimensional changes during pyrolysis were anisotropic with greater shrinkage in the stacking direction of the material.

Yoon, Bola [ORNL] (ORCID:0000000260875373)↗

Reconstituted Three-Dimensional Interactive Imaging

A method combines two-dimensional images, enhancing the images as well as rendering a 3D, enhanced, interactive computer image or visual model. Any advanced compiler can be used in conjunction with any graphics library package for this method, which is intended to take digitized images and virtually stack them so that they can be interactively viewed as a set of slices. This innovation can take multiple image sources (film or digital) and create a "transparent" image with higher densities in the image being less transparent. The images are then stacked such that an apparent 3D object is created in virtual space for interactive review of the set of images. This innovation can be used with any application where 3D images are taken as slices of a larger object. These could include machines, materials for inspection, geological objects, or human scanning. Illuminous values were stacked into planes with different transparency levels of tissues. These transparency levels can use multiple energy levels, such as density of CT scans or radioactive density. A desktop computer with enough video memory to produce the image is capable of this work. The memory changes with the size and resolution of the desired images to be stacked and viewed.

Hamilton, Joseph↗

TBS (Trabecular Bone Score) Expands Understanding of Spaceflight Effects on the Lumbar Spine of Long-Duration Astronauts

Bone loss due to long‐duration spaceflight has been characterized by both DXA and QCT serial scans. It is unclear if these spaceflight‐induced changes in bone mineral density (BMD) and structure result in increased fracture incidence. NASA astronauts currently fly 5 to 6‐month missions on the International Space Station (ISS) and at least one 12‐month mission is planned. While NASA has measured areal BMD (by DXA) and volumetric BMD (by QCT) and has estimated hip strength (by finite element models of QCT data, no method has yet been used to examine bone micro‐architecture from lumbar spine (LS). DXA scans are routinely performed pre‐ and postflight on all ISS astronauts to follow BMD changes associated with spaceflight. Trabecular Bone Score (TBS) is a relatively new method that measures grey‐scale‐level texture information extracted from LS DXA images and correlates with 3D parameters of bone micro‐architecture. We evaluated the ability of LS TBS to discriminate changes in astronauts who have flown on ISS missions and to determine if TBS can provide additional information compared to DXA. Methods: Lumbar Spine (L1‐4) DXA scans from 51 astronauts (mean age, 47 +/- 4 yrs) were divided into 3 groups based on the exercise regimens performed onboard the ISS. "Pre‐ARED" (exercise using a load‐limited resistive exercise device, <300 lb), "ARED" (exercise with a high‐load resistive exercise device, up to 600 lb) and "Bisphos+ARED" group (ARED exercise and a 70‐mg alendronate tablet once a week before and during flight, starting 17 days before launch). DXA scans were performed and analyzed on a Hologic Discovery W using the same technician for the pre‐ and post‐flight scans. LSC for the LS in our laboratory is 0.025 g/sq. cm. TBS was performed at the Mercy Hospital, Cincinnati, Ohio on a similar Hologic computer. Data were analyzed using a paired, 2‐tailed Student's t‐test for the difference between pre‐ and postflight means. Percent change and % change per month are noted. Interpretation: Our data suggest that: TBS and DXA both detected significant decrements in the LS in these pre‐ ARED astronauts, not unexpected given the insufficient loads provided by this early exercise device. TBS did not detect significant changes in the ARED or Bisphos+ARED groups while DXA did detect significant changes in the ARED astronauts. These findings suggest that DXA and TBS are detecting independent effects of bone loss interventions tested in ISS astronauts in space, which may be due to distinct effects of interventions on mineral content of separate cortical vs. trabecular bone. Conclusion: TBS, in conjunction with DXA BMD, may provide additional insight into the nature of changes (or lack thereof) in the microstructure of trabecular bone and the areal BMD of vertebral bodies.

Smith, Scott A.↗

NASA's Astromaterials Database: Enabling Research Through Increased Access to Sample Data, Metadata and Imagery

The Astromaterials Acquisition & Curation Office at NASA's Johnson Space Center (JSC) is the designated facility for curating all of NASA's extraterrestrial samples. Today, the suite of collections includes the lunar samples from the Apollo missions, cosmic dust particles falling into the Earth's atmosphere, meteorites collected in Antarctica, comet and interstellar dust particles from the Stardust mission, asteroid particles from Japan's Hayabusa mission, solar wind atoms collected during the Genesis mission, and space‐exposed hardware from several missions. To support planetary science research on these samples, JSC's Astromaterials Curation Office hosts NASA's Astromaterials Curation digital repository and data access portal [http://curator.jsc.nasa.gov/], providing descriptions of the missions and collections, and critical information about each individual sample. Our office is designing and implementing several informatics initiatives to better serve the planetary research community. First, we are re‐hosting the basic database framework by consolidating legacy databases for individual collections and providing a uniform access point for information (descriptions, imagery, classification) on all of our samples. Second, we continue to upgrade and host digital compendia that summarize and highlight published findings on the samples (e.g., lunar samples, meteorites from Mars). We host high resolution imagery of samples as it becomes available, including newly scanned images of historical prints from the Apollo missions. Finally we are creating plans to collect and provide new data, including 3D imagery, point cloud data, micro CT data, and external links to other data sets on selected samples. Together, these individual efforts will provide unprecedented digital access to NASA's Astromaterials, enabling preservation of the samples through more specific and targeted requests, and supporting new planetary science research and collaborations on the samples.

Evans, Cindy↗

Kilovoltage cone-beam CT: Comparative dose and image quality evaluations in partial and full-angle scan protocols

Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dose thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.

60 APPLIED LIFE SCIENCES↗

Spin Excitations in a 4f−3d Heterodimer on MgO

We report on the magnetic properties of HoCo dimers as a model system for the smallest intermetallic compound of a lanthanide and a transition metal atom. The dimers are adsorbed on ultrathin MgO(100) films grown on Ag(100). New for 4f elements, we detect inelastic excitations with scanning tunneling spectroscopy and prove their magnetic origin by applying an external magnetic field. In combination with density functional theory and spin Hamiltonian analysis, we determine the magnetic level distribution, as well as sign and magnitude of the exchange interaction between the two atoms. In contrast to typical 4f-3d bulk compounds, we find ferromagnetic coupling in the dimer. © 2018 American Physical Society.

60 APPLIED LIFE SCIENCES↗

High-speed volumetric two-photon fluorescence imaging of neurovascular dynamics

Abstract Understanding the structure and function of vasculature in the brain requires us to monitor distributed hemodynamics at high spatial and temporal resolution in three-dimensional (3D) volumes in vivo. Currently, a volumetric vasculature imaging method with sub-capillary spatial resolution and blood flow-resolving speed is lacking. Here, using two-photon laser scanning microscopy (TPLSM) with an axially extended Bessel focus, we capture volumetric hemodynamics in the awake mouse brain at a spatiotemporal resolution sufficient for measuring capillary size and blood flow. With Bessel TPLSM, the fluorescence signal of a vessel becomes proportional to its size, which enables convenient intensity-based analysis of vessel dilation and constriction dynamics in large volumes. We observe entrainment of vasodilation and vasoconstriction with pupil diameter and measure 3D blood flow at 99 volumes/second. Demonstrating high-throughput monitoring of hemodynamics in the awake brain, we expect Bessel TPLSM to make broad impacts on neurovasculature research.

59 BASIC BIOLOGICAL SCIENCES↗

Image-based reconstruction of three-dimensional myocardial infarct geometry for patient-specific modeling of cardiac electrophysiology

Purpose: Accurate three-dimensional (3D) reconstruction of myocardial infarct geometry is crucial to patient-specific modeling of the heart aimed at providing therapeutic guidance in ischemic cardiomyopathy. However, myocardial infarct imaging is clinically performed using two-dimensional (2D) late-gadolinium enhanced cardiac magnetic resonance (LGE-CMR) techniques, and a method to build accurate 3D infarct reconstructions from the 2D LGE-CMR images has been lacking. The purpose of this study was to address this need. Methods: The authors developed a novel methodology to reconstruct 3D infarct geometry from segmented low-resolution (Lo-res) clinical LGE-CMR images. Their methodology employed the so-called logarithm of odds (LogOdds) function to implicitly represent the shape of the infarct in segmented image slices as LogOdds maps. These 2D maps were then interpolated into a 3D image, and the result transformed via the inverse of LogOdds to a binary image representing the 3D infarct geometry. To assess the efficacy of this method, the authors utilized 39 high-resolution (Hi-res) LGE-CMR images, including 36 in vivo acquisitions of human subjects with prior myocardial infarction and 3 ex vivo scans of canine hearts following coronary ligation to induce infarction. The infarct was manually segmented by trained experts in each slice of the Hi-res images, and the segmented data were downsampled to typical clinical resolution. The proposed method was then used to reconstruct 3D infarct geometry from the downsampled images, and the resulting reconstructions were compared with the manually segmented data. The method was extensively evaluated using metrics based on geometry as well as results of electrophysiological simulations of cardiac sinus rhythm and ventricular tachycardia in individual hearts. Several alternative reconstruction techniques were also implemented and compared with the proposed method. Results: The accuracy of the LogOdds method in reconstructing 3D infarct geometry, as measured by the Dice similarity coefficient, was 82.10% ± 6.58%, a significantly higher value than those of the alternative reconstruction methods. Among outcomes of electrophysiological simulations with infarct reconstructions generated by various methods, the simulation results corresponding to the LogOdds method showed the smallest deviation from those corresponding to the manual reconstructions, as measured by metrics based on both activation maps and pseudo-ECGs. Conclusions: The authors have developed a novel method for reconstructing 3D infarct geometry from segmented slices of Lo-res clinical 2D LGE-CMR images. This method outperformed alternative approaches in reproducing expert manual 3D reconstructions and in electrophysiological simulations.

60 APPLIED LIFE SCIENCES↗

Transient modes of zeolite surface growth from 3D gel-like islands to 2D single layers

Zeolite crystallization occurs by multifaceted processes involving molecule attachment and nonclassical pathways governed by the addition of amorphous precursors. Here, we use scanning probe microscopy to monitor zeolite LTA crystallization in situ with a spatiotemporal resolution that captures dynamic processes in real time. We report a distinctive pathway involving the formation of gel-like islands from supersaturated solutions comprised of (alumino)silicate molecules. Three-dimensional assembly and evolution of these islands constitutes a unique mode of growth that differs from classical theories. Time-resolved imaging also reveals that growth can occur by (nearly) oriented attachment. At later stages of crystallization, a progressive transition to lower supersaturation shifts growth to a layered mechanism involving two-dimensional nucleation and spreading of layers. Here, we show that LTA crystallization occurs by multiple pathways, thereby reconciling putative hypotheses of growth mechanisms while also highlighting new modes of nonclassical crystallization that may prove relevant to other zeolites and related materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From Voxels to Knowledge: A Practical Guide to the Segmentation of Complex Electron Microscopy 3D-Data

Modern 3D electron microscopy approaches have recently allowed unprecedented insight into the 3D ultrastructural organization of cells and tissues, enabling the visualization of large macromolecular machines, such as adhesion complexes, as well as higher-order structures, such as the cytoskeleton and cellular organelles in their respective cell and tissue context. Given the inherent complexity of cellular volumes, it is essential to first extract the features of interest in order to allow visualization, quantification, and therefore comprehension of their 3D organization. Each data set is defined by distinct characteristics, e.g., signal-to-noise ratio, crispness (sharpness) of the data, heterogeneity of its features, crowdedness of features, presence or absence of characteristic shapes that allow for easy identification, and the percentage of the entire volume that a specific region of interest occupies. All these characteristics need to be considered when deciding on which approach to take for segmentation. The six different 3D ultrastructural data sets presented were obtained by three different imaging approaches: resin embedded stained electron tomography, focused ion beam- and serial block face- scanning electron microscopy (FIB-SEM, SBF-SEM) of mildly stained and heavily stained samples, respectively. For these data sets, four different segmentation approaches have been applied: (1) fully manual model building followed solely by visualization of the model, (2) manual tracing segmentation of the data followed by surface rendering, (3) semi-automated approaches followed by surface rendering, or (4) automated custom-designed segmentation algorithms followed by surface rendering and quantitative analysis. Depending on the combination of data set characteristics, it was found that typically one of these four categorical approaches outperforms the others, but depending on the exact sequence of criteria, more than one approach may be successful. Based on these data, we propose a triage scheme that categorizes both objective data set characteristics and subjective personal criteria for the analysis of the different data sets.

3D electron microscopy↗

Effect of printing parameters on 3D-printed carbon fiber-reinforced polymer composites under magnetic field control

Magnetic field controlled (MFC) 3D printing is a promising method for realizing the intelligent control of the structural performance of carbon fiber-reinforced plastic (CFRP) composites by adjusting the fiber orientation during the printing process. However, few studies have focused on the influence of the printing parameters on the magnetic control of the fiber direction. Therefore, in this study, the mechanical properties and internal fiber distributions of MFC 3D-printed samples of CFRP composites with 10 wt% fiber content, which were printed at different speeds and layer thicknesses, were investigated. Subsequently, the effects of the fiber content on the mechanical properties and fiber distribution of the MFC 3D-printed samples were studied. Furthermore, the origin of fiber fracture was evaluated through observation and analysis of the fracture section using scanning electron microscopy. The fiber orientation could be well adjusted under the action of a magnetic field and adjustment of printing parameters, thereby improving the tensile strength, young's modulus significantly with slightly decrease of fracture elongation. The recommended parameter combinations (printing speed and layer thickness) were 40 mm/s and 0.2 mm for 10 wt% fiber content CFRP composites.

36 MATERIALS SCIENCE↗