Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators,OTHER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Particle-in-cell simulation of x-ray wakefield acceleration and betatron radiation in nanotubes

Though wakefield acceleration in crystal channels has been previously proposed, x-ray wakefield acceleration has only recently become a realistic possibility since the invention of the single-cycled optical laser compression technique. We investigate the acceleration due to a wakefield induced by a coherent, ultrashort x-ray pulse guided by a nanoscale channel inside a solid material. By two-dimensional particle-in-cell computer simulations, we show that an acceleration gradient of TeV/cm is attainable. This is about 3 orders of magnitude stronger than that of the conventional plasma-based wakefield accelerations, which implies the possibility of an extremely compact scheme to attain ultrahigh energies. In addition to particle acceleration, this scheme can also induce the emission of high energy photons at ∼O(10–100) MeV. Our simulations confirm such high energy photon emissions, which is in contrast with that induced by the optical laser driven wakefield scheme. In addition to this, the significantly improved emittance of the energetic electrons has been discussed.

43 PARTICLE ACCELERATORS↗

Synchronous acceleration with tapered dielectric-lined waveguides

Here, we present a general concept to accelerate non-relativistic charged particles. Our concept employs an adiabatically-tapered dielectric-lined waveguide which supports accelerating phase velocities for synchronous acceleration. We propose an ansatz for the transient field equations, show it satisfies Maxwell's equations under an adiabatic approximation and find excellent agreement with a finite-difference time-domain computer simulation. The fields were implemented into the particle-tracking program {\sc astra} and we present beam dynamics results for an accelerating field with a 1-mm-wavelength and peak electric field of 100~MV/m. The numerical simulations indicate that a $\sim 200$-keV electron beam can be accelerated to an energy of $\sim10$~MeV over $\sim 10$~cm. The novel scheme is also found to form electron beams with parameters of interest to a wide range of applications including, e.g., future advanced accelerators, and ultra-fast electron diffraction.

43 PARTICLE ACCELERATORS↗

Differentiable Preisach Modeling for Characterization and Optimization of Particle Accelerator Systems with Hysteresis

Future improvements in particle accelerator performance are predicated on increasingly accurate online modeling of accelerators. Hysteresis effects in magnetic, mechanical, and material components of accelerators are often neglected in online accelerator models used to inform control algorithms, even though reproducibility errors from systems exhibiting hysteresis are not negligible in high precision accelerators. Here, we combine the classical Preisach model of hysteresis with machine learning techniques to efficiently create nonparametric, high-fidelity models of arbitrary systems exhibiting hysteresis. We experimentally demonstrate how these methods can be used in situ, where a hysteresis model of an accelerator magnet is combined with a Bayesian statistical model of the beam response, allowing characterization of magnetic hysteresis solely from beam-based measurements. Finally, we explore how using these joint hysteresis-Bayesian statistical models allows us to overcome optimization performance limitations that arise when hysteresis effects are ignored.

43 PARTICLE ACCELERATORS↗

Summary of Working Group 3: Laser and High-Gradient Structure-Based Acceleration

Accelerating particles at high gradients with high efficiencies is essential for reduction of size and cost of future accelerators for science and industry. This includes a future multi-TeV e+e- collider for particle, free-electron lasers for basic energy sciences and national security, industrial accelerators for energy and environmental applications, and accelerators for other applications. One way to achieve this is to use advanced externally-powered structures, both laser and RF driven. Working Group 3 (WG3) discussed novel accelerating structures with new geometries, new materials, frequencies from microwave to THz and optical spectrum, and operating conditions from room temperature to cryogenic. Presentations included recent advances in understanding RF breakdown and multipactor phenomena at different frequencies and materials, and other physics limitations to the accelerating gradient. Other relevant topics, such as developing high-gradient photoinjectors, high-efficiency RF power sources, and RF structures for a potential muon collider were discussed also. More details on each of the WG3 topics can be found in the articles published in these proceedings.

43 PARTICLE ACCELERATORS↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.

60 APPLIED LIFE SCIENCES↗

Start-to-End Simulation of the Drive-Beam Longitudinal Dynamics for Beam-Driven Wakefield Acceleration

Collinear beam-driven wakefield acceleration (WFA) relies on shaped driver beam to provide higher accelerating gradient at a smaller cost and physical footprint. This acceleration scheme is currently envisioned to accelerate electron beams capable of driving free-electron laser *. Start-to-end simulation of drive-bunch beam dynamics is crucial for the evaluation of the design of accelerators built upon WFA. We report the start-to-end longitudinal beam dynamics simulations of an accelerator beamline capable of producing high charge drive beam. The generated wakefield when it passes through a corrugated waveguide results in a transformer ratio of 5. This paper especially discusses the challenges and criteria associated with the generation of temporally-shaped driver beam, including the beam formation in the photoinjector, and the influence of energy chirp control on beam transport stability.

43 PARTICLE ACCELERATORS↗

Beam Dynamics Studies and the Design, Fabrication and Testing of Superconducting Radiofrequency Cavity for High Intensity Proton Accelerator

The application horizon of particle accelerators has been widening significantly in recent decades. Where large accelerators have traditionally been the tools of the trade for high-energy nuclear and particle physics, applications in the last decade have grown to include large-scale accelerators like synchrotron light sources and spallation neutron sources. Applications like generation of rare isotopes, transmutation of nuclear reactor waste, sub-critical nuclear power, generation of neutrino beams etc. are next area of investigation for accelerator scientific community all over the world. Such applications require high beam power in the range of few mega-watts (MW). One such high intensity proton beam facility is proposed at Fermilab, Batavia, US, named as Project-X. Project-X facility is based on H - linear accelerator (linac), which will operate in continuous wave (CW) mode and accelerate H - ion beam with average current of 1 mA from kinetic energy of 2.5 MeV to 3 GeV to deliver 3MW beam power. One of the most challenging tasks of the Project-X facility is to have a robust design of the CW linac which can provide high quality beam to several experiments simultaneously. Hence a careful design of linac is important to achieve this objective.

43 PARTICLE ACCELERATORS↗

Advanced Beamline Design for Fermilab's Advanced Superconducting Test Accelerator

The Advanced Superconducting Test Accelerator (ASTA) at Fermilab is a new electron accelerator currently in the commissioning stage. In addition to testing superconducting accelerating cavities for future accelerators, it is foreseen to support a variety of Advanced Accelerator R&D (AARD) experiments. Producing the required electron bunches with the expected flexibility is challenging. The goal of this dissertation is to explore via numerical simulations new accelerator beamlines that can enable the advanced manipulation of electron bunches. The work especially includes the design of a low-energy bunch compressor and a study of transverse-to-longitudinal phase space exchangers.

43 PARTICLE ACCELERATORS↗

Fermilab Accelerator Complex: Status and Improvement Plans

Fermilab carries out an extensive program of accelerator-based high-energy particle physics research, which relies on 8 GeV and 120 GeV proton accelerators. Routine operations with 700 kW, 120 GeV proton beam power on a neutrino target was achieved in 2017. There are plans to further increase the beam power to the 900 kW range. The next major upgrade of the Fermilab accelerator complex, the PIP-II project, is under development. Its goal is to deliver 1.2 MW of beam power on target at the start of the DUNE experiment in the middle of the next decade. PIP-II will replace the existing 40-year old 400 MeV normal-conducting Linac with a modern 800 MeV superconducting RF based linear accelerator. There are several concepts for future upgrades that will increase the beam power to >2.4 MW, after replacement of the existing 8 GeV Booster synchrotron. The Muon Campus provides 3.1 GeV polarized muons to the g-2 experiment and will provide 8 kW of 8 GeV protons to the Mu2e production target. The Fermilab Test Beam Facility provides a primary 120 GeV proton beam of moderate intensity, (1-300 kHz) and secondary particle beams of energies down to about 1 GeV, consisting of hadrons, muons and/or electrons/photons for detectors tests. In this article we discuss the current performance of the Fermilab accelerator complex, the upgrade plans for the next two decades, and the accelerator R&D program to address cost and performance risks for these upgrades.

43 PARTICLE ACCELERATORS↗

Collaboration on Radiation Driven Chemistry and Accelerator Operations

The Notre Dame Radiation Laboratory (NDRL) will contribute subject matter expertise to increase the Fermilab Illinois Accelerator Research (IARC) team’s knowledge of radiation chemistry processes. NDRL will do this by offering guidance on what analytical equipment to use to measure the effects of electron beam treatment during and post treatment. NDRL will also offer guidance that will help further develop IARC applications. The application areas are not limited to, but may include chemistries in the energy generation, industrial and environmental sectors. Fermi National Accelerator Laboratory’s IARC team will contribute subject matter expertise on accelerator operations to help NDRL optimize operation of their Titan-Beta accelerator. The objective of NDRL is to optimize accelerator output, as well as the beam transport and focusing from the accelerator to several experimental beam ports. NDRL also wants to install and optimize a new subharmonic pre-buncher to be able to deliver sub-nanosecond timescale doses for the study of reaction kinetics decoupled from molecular diffusion.

43 PARTICLE ACCELERATORS↗

Maximizing the efficiency of plasma-based lepton accelerators

The next generation of particle accelerators will likely rely on compact accelerating structures to achieve very high gradients; one such candidate is accelerators using plasmas for the accelerating structures. Because of the small length scales of these structures, they can also be prone to the beam break-up instability, which would spoil the quality of the beam and leave it unsuitable for many applications. The goal of this project is to develop a framework for understanding the instabilities in plasma accelerators using language from conventional linear accelerator instabilities, such as wake fields and wake functions. During the course of this Phase I, we benchmarked a pseudo-spectral particle-in-cell code to determine its suitability for computing wake functions, and developed a procedure for extracting wake functions from a sequence of simulations using this code.

43 PARTICLE ACCELERATORS↗

RF Accelerator Technology R&D: Report of AF7-rf Topical Group to Snowmass 2021

Accelerator radio frequency (RF) technology has been and remains critical for modern high energy physics (HEP) experiments based on particle accelerators. Tremendous progress in advancing this technology has been achieved over the past decade in several areas highlighted in this report. These achievements and new results expected from continued R&D efforts could pave the way for upgrades of existing facilities, improvements to accelerators already under construction (e.g., PIP-II), well-developed proposals (e.g., ILC, CLIC), and/or enable concepts under development, such as FCC-ee, CEPC, C 3 , HELEN, multi-MW Fermilab Proton Intensity Upgrade, future Muon Colloder, etc. Advances in RF technology have impact beyond HEP on accelerators built for nuclear physics, basic energy sciences, and other areas. Recent examples of such accelerators are European XFEL, LCLS-II and LCLS-II-HE, SHINE, SNS, ESS, FRIB, and EIC. To support and enable new accelerator-based applications and even make some of them feasible, we must continue addressing their challenges via a comprehensive RF R&D program that would advance the existing RF technologies and explore the nascent ones.

43 PARTICLE ACCELERATORS↗

Strategy for Modernizing a 40-Year-Old Accelerator Control System

Modernizing the Fermilab accelerator control system is essential to future operations of the laboratory's accelerator complex. The existing control system has evolved over four decades and uses hardware that is no longer available and software that uses obsolete frameworks. The Accelerator Controls Operations Research Network (ACORN) Project will modernize the control system and replace end-of-life power supplies to enable future accelerator complex operations with megawatt particle beams. The project team is evaluating three design concepts, and the future deployment of artificial intelligence capabilities for accelerator operations is an important consideration. An overview of the ACORN Project will be presented, including R&D used for evaluating the conceptual designs in the context of requirements for future accelerator operations.

43 PARTICLE ACCELERATORS↗

Nondestructive Evaluation of Rexolite Insulators for the Purpose of Monitoring the Structural Health of Particle Accelerator

Rexolite is a cross-linked polystyrene plastic with stable electrical properties into the gigahertz frequency range. The ability to withstand high voltage makes Rexolite one of the most used materials as insulators for particle accelerators. Although, Rexolite’s poor outgassing performance relative to traditional vacuum materials such as stainless steel or aluminum deems the necessity to treat Rexolite prior to its use as insulators. Insulators are mandatory for an accelerator system because a uniform electric field is required to ensure the alignment of the accelerated particles. Furthermore, to operate properly, a particle accelerator is required to maintain a high vacuum or even an ultrahigh vacuum. Although, because outgassing is the major contributor to the gas load of a vacuum system, Rexolite insulators with uncontrolled outgassing characteristics can severely damage the particle accelerator. Disassembly and reassembly of a complex system like a particle accelerator is also time consuming.

36 MATERIALS SCIENCE↗

Design Philosophy for Accelerator Control Rooms

This report describes the foundational human factors principles needed to design user interfaces for accelerator control rooms. These principles are presented as recommendations for accelerator control system interface design and are illustrated with examples drawn from accelerator operations at Fermi National Accelerator Laboratory (Fermilab). These high-level principles are intended to serve as design objectives that apply generally across all control system interfaces developed for the accelerator complex. These principles will be mapped to more specific design guidance that will be provided in a style guide for accelerator operations.

43 PARTICLE ACCELERATORS↗

Collaboration for Advanced Modeling of Particle Accelerators

The pverarching purpose is to accelerate and expand the scope of discoveries from high energy physics (HEP) particle accelerators by enabling the design of accelerators that are significantly more compact and cheaper to build and run. This will be realized through (i) developing high-performance computing (HPC) accelerator and beam modeling capabilities to design the full range of systems required (ii) developing community simulation ecosystems that seamlessly integrate accelerator elements to facilitate the design and control of next-generation accelerators.

43 PARTICLE ACCELERATORS↗