Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Birth and Evolution of the Universe: How Detectors Have Revolutionized Space Astronomy

The past century has seen tremendous advances in the capability of instruments used for astronomical imaging and spectroscopy. Capabilities of instruments have expanded in many dimensions; the scale of telescopes has grown tremendously, the wavelengths used for astronomy have grown from visible light to the full electromagnetic spectrum, extending from gamma rays to low frequency radio waves. Additional advances have been enabled by the availability of space facilities, which eliminate the effects of the earths atmosphere and magnetosphere, and allow cooling of instruments to avoid instrumental thermal radiation. Even with all these advances, the increase in capability of detection systems has produced truly revolutionary improvements in capability. Today, I will describe the advances in astronomical detection from the photographic plates of the early 20th century to the giant high efficiency focal planes being developed for modern space and ground based astronomical instrument. I will review the demanding performance requirements set by space astronomy, and show how the detector community has risen to the challenge in producing high performance detectors for the Hubble Space Telescope, the Spitzer Space Telescope, and the James Webb Space Telescope, now under development.

Moseley, Samuel H.↗

Boundary Layer Exploration of Aerosols and Clouds ON Ships (BEACONS)

BEACONS aims to demonstrate autonomous deployment of a shipborne system that routinely observes atmospheric, cloud, and aerosol properties. These observations enable scientists to study aerosol-cloud interactions, advancing energy resilience and the Department of Energy's mission to improve model prediction. Key Project Outcomes Autonomous deployment of aerosol and cloud measurement systems aboard a Pasha Hawaii Marjorie C commercial ship. Six-month campaign for continuous, high-resolution aerosol and cloud data collection with minimal crew intervention. Development and testing of instruments in two phases, advancing from essential to complex systems. AI-ready processed data on the BEACONS Data Platform for near-real-time data access. Validation of aerosol-cloud interaction hypotheses for improved modeling. Establishment of best practices for instrument deployment in marine environments. Scientific collaboration to support the U.S. Department of Energy (DOE) Biological and Environmental Research (BER) mission.

54 ENVIRONMENTAL SCIENCES↗

Visualization of Multi-Dimensional Imaging Data for the DIII-D National Fusion Facility

With funding provided from the Office of Fusion Energy Science’s program on Diagnostic Systems for Magnetic Fusion Energy Sciences, the PI and his team have pioneered the development of microwave imaging systems for magnetic fusion plasma diagnostics. Specifically, electron cyclotron emission (ECE) imaging [1], a passive radiometric technique, measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) [2], an active radar imaging technique, measures electron density fluctuations. These microwave imaging diagnostic instruments developed by UC Davis have made important contributions to fusion science in a relatively short period of time from their original installation on DIII-D. The microwave imaging diagnostic technique has matured considerably since the beginning of a fruitful collaboration with DIII-D and PPPL, and has also been adopted at preeminent tokamak facilities worldwide. As discussed in detail in the following, this has continued with the development of revolutionary microwave diagnostic instruments employing monolithic millimeter wave integrated circuit (MMIC) system-on-chip (SoC) technology. Specifically, “chip” receivers mounted in liquid crystal polymer (LCP) modules have been demonstrated to dramatically improve the performance of the electron cyclotron emission imaging (ECEI) system including: 30x improvement in noise temperature thereby permitting absolute 2-D electron temperature images, outstanding shielding against out-of-band interference including microwave bursting which had plagued previous ELM studies using the old quasi-optical mini-lens ECEI system, and independent modules facilitating flexible repair and replacement. Under the “Visualization of multi-dimensional imaging data for the DIII-D National Fusion Facility” program, funding was provided for a research scientist postdoc and a Ph.D. student to support physics studies at DIII-D employing these instruments. This endeavor is synergistic with our current grant under the DOE Fusion Energy Sciences (FES) program on Diagnostic Systems for Magnetic Fusion Energy Sciences. This support considerably increased the scientific output of the diagnostics. The activities were strongly focused in the areas of pedestal and ELM stability, energetic particle confinement, and the early detection and avoidance of tokamak disruptions employing the microwave imaging diagnostic instruments developed under the advanced diagnostics program where imaging of the ELM crash was made possible by the elimination of the interference from the associated microwave “bursts”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on plasma jet printer for sensor fabrication with process parameters optimized by simulation input

The In-Pile Instrumentation program conducts research to develop instrumentation that provides information regarding test conditions, as well as fuel and materials properties during irradiation. Such instruments must be miniaturized, robust to the nuclear reactor environment, and provide real-time data aligned with user needs. Towards this end, additive manufacturing techniques such as aerosol jet printing and Plasma Jet Printing, have demonstrated significant potential for the development of advanced in-pile instrumentation. Process control during the manufacturing process is critical in order to consistently create reliable sensors. This report details experimental and computational work aimed towards improved process control for robust sensor production using printing techniques.

36 MATERIALS SCIENCE↗

Analysis of Envisat Orbit Maintenance Strategies to Improve/Increase Envisat ASAR Interferometry Opportunities

The biggest and most advanced Earth Observation Satellite in-orbit, developed by the European Space Agency (ESA) and its member states, is Envisat. It was launched on March 1, 2002 by an Ariane V from French Guyana and holds a total of 10 multi-disciplinary Earth observation instruments, among which an Advanced Synthetic Aperture Radar (ASAR). The ASAR user community requested the Flight Dynamics division of the European Space Operations Centre (ESOC) to investigate how the orbit control maintenance strategy for Envisat could be changed to optimize ASAR interferometry opportunities overall and in addition support the International Polar Year 2007/2008 initiative. The Polar Regions play a pivotal role in understanding our planet and our impact on it as they are recognized as sensitive barometers of environmental change. One of the main themes of the International Polar Year 2007/2008 is therefore the study of Earth s changing ice and snow, and its impact on our planet and our lives. Naturally, ESA would like to support this very important initiative. This paper presents the investigations that have been conducted to support these requests in the best possible way. It discusses the orbit maintenance strategy that has been in place since its launch, ensuring the actual orbit to be within 1 km of a so-called reference orbit, and presents the new orbit maintenance strategy that is aimed at improving/increasing the opportunities for Envisat ASAR interferometry, while preserving the fuel on board the spacecraft. The hydrazine on-board Envisat happens to be a precious resource as only approximately 300 kg of it was available at launch, like ERS-2. The difference being however that the mass of Envisat is approximately 3.2 times that of ERS-2.

Kuijper, D.↗

Optical design of the Mapping Imaging Spectrometer for Europa (MISE)

e Mapping Imaging Spectrometer for Europa (MISE) is a high-throughput pushbroom imaging spectrometer designed for NASA’s planned flyby mission to Jupiter’s moon Europa. The MISE design utilizes heritage from previously demonstrated instruments on airborne platforms, while advancing the state of the art to operate within Europa’s challenging environment. The instrument operates at F/1.4 and covers a spectral range from 0.8 to 5 microns with 10 nm spectral sampling. Through high resolution mapping, MISE is designed to identify distributions of organics, salts, acid hydrates, water ice phases, altered silicates, radiolytic compounds, and warm thermal anomalies at global, regional, and local scales. Such distribution maps will help study surface and subsurface geologic processes, and assess the habitability of Europa’s ocean. We discuss the optical specifications and baseline performance of the MISE optical design.

Van Gorp, Byron E.↗

Developmental long trace profiler using optimally aligned mirror based pentaprism

A low-budget surface slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought into operation at the Advanced Light Source Optical Metrology Laboratory [Nucl. Instr. and Meth. A 616, 212-223 (2010)]. The instrument is based on a precisely calibrated autocollimator and a movable pentaprism. The capability of the DLTP to achieve sub-microradian surface slope metrology has been verified via cross-comparison measurements with other high-performance slope measuring instruments when measuring the same high-quality test optics. In the present work, a further improvement of the DLTP is achieved by replacing the existing bulk pentaprism with a specially designed mirror based pentaprism. A mirror based pentaprism offers the possibility to eliminate systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of a bulk pentaprism. We provide the details of the mirror based pentaprism design and describe an original experimental procedure for precision mutual alignment of the mirrors. The algorithm of the alignment procedure and its efficiency are verified with rigorous ray tracing simulations. Results of measurements of a spherically curved test mirror and a flat test mirror using the original bulk pentaprism are compared with measurements using the new mirror based pentaprism, demonstrating the improved performance.

47 OTHER INSTRUMENTATION↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Martian Radiation Environment Experiment (MARIE)

Space radiation presents a very serious hazard to crews of interplanetary human missions. The two sources of this radiation are the galactic cosmic rays (GCR) and solar energetic particle (SEP) events. The GCR provides a steady source of low dose rate radiation that is primarily responsible for stochastic effects, such as cancer, and can effect the response of the central nervous system. Nuclear interactions of these components with the Martian atmosphere produces substantial flux of neutrons with high Radio Biological Effectiveness. The uncertainty in the knowledge of many fragmentation cross sections and their energy dependence required by radiation transport codes, uncertainties in the ambient radiation environment, and knowledge of the Martian atmosphere, lead to large enough uncertainties in the knowledge of calculated radiation dose in both free space (cruise phase), in Martian orbit, and on Martian surface. Direct measurements of radiation levels, the relative contributions of protons, neutrons, and heavy ions, and Martian atmospheric characteristics is thus a prerequisite for any human mission. An integrated suite of two spectrometers to provide these data will be described. The Orbiter spectrometer will measure the energy spectrum of SEP events from 15 to 500 MeV/n, and when combined with data from other space based instruments, such as the Advanced Composition Explorer (ACE), would provide accurate GCR spectra also. The Lander spectrometer would measure the absorbed dose rate, dose equivalent dose rate, and the linear energy transfer (LET) spectra and is capable of separating the relative contribution of these quantities from protons, neutrons, and high Z particles. There are two separate flight instruments, one for the Orbiter and one for the Lander, based on a common design of the backplane, the central processing unit (CPU), power supply, and onboard data storage. The Orbiter instrument consists of an energetic particle spectrometer that can measure the elemental energy spectra of charged particles over energy range of 15-500 MeV/n. The spectrometer will be mounted on the science deck and has an angular acceptance of 50 degrees. As the spacecraft orbits Mars, the axis of this field of view sweeps a cone of directions on the sky. During each orbit, the angle between the axis of the spectrometer's field of view and the mean interplanetary field direction varies from 90 degrees to 180 degrees. The Lander instrument is designed: (1) to measure the accumulated absorbed dose and dose rate in tissue as a function of time, (2) to determine the radiation quality factor, (3) to determine the energy deposition spectrum from 0.1 keV/micron to 1500 keV/micron, and (4) to separate the contribution of protons, neutrons, and HZE particles to these quantities.

Badhwar, Gautam D.↗

Probing the Subsurface of the Martian Polar Regions with MARSIS on Mars Express

The European Space Agency (ESA) is currently conducting a mission to Mars known as Mars Express. The orbiter carries an instrument called the Mars Advanced Radar for Subsurface and Ionospheric Sounding (MARSIS). The MARSIS experiment is a joint project between NASA and the Italian Space Agency, and is being carried out by the University of Rome, the Jet Propulsion Laboratory, Alenia Aerospazio, and the University of Iowa. This paper describes the science objectives of the experiment, the instrument characteristics, and applications of the MARSIS investigation to studies of the martian polar regions.

Plaut, J. J.↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Electrochemical carbon dioxide concentrator subsystem development

The fabrication of a one-person Electrochemical Depolarized Carbon Dioxide Concentrator subsystem incorporating advanced electrochemical, mechanical, and control and monitor instrumentation concepts is discussed. This subsystem included an advanced liquid cooled unitized core composite cell module and integrated electromechanical components. Over 1800 hours with the subsystem with removal efficiencies between 90%. and 100%; endurance tests with a Fluid Control Assembly which integrates 11 gas handling components of the subsystem; and endurance testing of a coolant control assembly which integrates a coolant pump, diverter valve and a liquid accumulator were completed.

Heppner, D. B.↗

In Situ Resource Utilization (ISRU) on the Moon: Moessbauer Spectroscopy as a Process Monitor for Oxygen Production

Essential consumables like oxygen must to be produced from materials on the lunar surface to enable a sustained, long-term presence of humans on the Moon. The Outpost Precursor for ISRU and Modular Architecture (OPTIMA) field test on Mauna Kea, Hawaii, facilitated by the Pacific International Space Center for Exploration Systems (PISCES) of the University of Hawaii at Hilo, was designed to test the implementation of three hardware concepts to extract oxygen from the lunar regolith: Precursor ISRU Lunar Oxygen Testbed (PILOT) developed by Lockheed Martin in Littleton, CO; Regolith & Environmental Science and Oxygen & Lunar Volatiles Extraction (RESOLVE) developed at the NASA Kennedy Space Center in Cape Canaveral, FL; and ROxygen developed at the NASA Johnson Space Center in Houston, TX. The three concepts differ in design, but all rely on the same general principle: hydrogen reduction of metal cations (primarily Fe2+) bonded to oxygen to metal (e.g., Fe0) with the production of water. The hydrogen source is residual hydrogen in the fuel tanks of lunar landers. Electrolysis of the water produces oxygen and hydrogen (which is recycled). We used the miniaturized M ssbauer spectrometer MIMOS II to quantify the yield of this process on the basis of the quantity of Fe0 produced. Iron M ssbauer spectroscopy identifies iron-bearing phases, determines iron oxidation states, and quantifies the distribution of iron between mineral phases and oxidation states. The oxygen yield can be calculated by quantitative measurements of the distribution of Fe among oxidation states in the regolith before and after hydrogen reduction. A M ssbauer spectrometer can also be used as a prospecting tool to select the optimum feedstock for the oxygen production plants (e.g., high total Fe content and easily reduced phases). As a demonstration, a MIMOS II backscatter spectrometer (SPESI, Germany) was mounted on the Cratos rover (NASA Glenn Research Center in Cleveland, OH), which is one of several rover concepts designed to excavate and transfer regolith to the stationary hydrogen reduction plants. Spaceflight versions of the MIMOS II are part of the instrument payloads of NASA s Mars Exploration Rovers and still operating five years after landing on the surface of the planet. MIMOS II was also selected for Phobos-Grunt, a Russian sample return mission to the martian moon Phobos scheduled to launch in 2009, and ESA s ExoMars rover, an exobiology mission scheduled to launch in 2013. An advanced version of the instrument is currently under development. A new detector system with a higher energy resolution will not only reduce the necessary measurement time considerably, but also allow the simultaneous acquisition of an X-ray fluorescence spectrum to determine the elemental composition of samples.

Morris, R.V.↗

The Alliance of Advanced Process Control and Accountability – A Future Safeguards-By-Design Tool

For any chemical separation process producing a valuable product, a material balance is an important process control measurement. That is particularly true for the separation of actinides from irradiated nuclear fuel, not only for their intrinsic value but also because an incomplete material balance may indicate diversion for unauthorized use. The DOE Office of Nuclear Energy is currently carrying out at the Pacific Northwest National Laboratory an experimental measurement of how well and with what precision current technologies can implement near real-time actinide material balances. This measurement effort is called the CoDCon project. It involves the separation of a product with a 70/30 uranium/plutonium mass ratio. Initial tests will use dissolved fuel simulants prepared with pure uranium and plutonium nitrates at the same input ratios as irradiated fuel. Subsequent testing with actual irradiated fuel would be done to verify the results obtained with simulants. The experiments will use advanced on-line instrumentation supported by dynamic process models. Since accountability uncertainties could mask diversions, the aim of the project is not only to measure present-day capabilities but also, through sensitivity analyses, to identify those measurements with the greatest potential for overall material-balance improvements. The latter results will help identify priorities for future fuel cycle R&D programs. Advanced separations process control and material accountability technologies thus have a common goal: to provide the best tools available for safeguards-by-design [defined by the International Atomic Energy Agency (IAEA) as the integration of the design of a new nuclear facility through planning, construction, operation and decommissioning]. Since the potential domestic use of CoDCon results may be later than their possible foreign applications, arrangements may be feasible for possible bilateral or multinational cooperation in the CoDCon project.

Lumetta, Gregg J.↗

Inertial corrections by dynamic estimation

The highlights are presented of an Engineering Memorandum, Dynamic Estimation for Floated Gradiometers. The original impetus for the work was that gradiometers, in principle, measure components of the gravity gradient tensor, plus rotation effects, similar to centrifugal and Coriolis effects in accelerometers. The problem is that the rotation effects are often quite large, compared to the gradient, and that available inertial instruments can't measure them to adequate accuracy. The paper advances the idea that, if the instruments can be floated in a package subject to very low disturbances, a dynamic estimation, based on the Euler and translational equations of motion, plus models of all the instruments, can be used to greatly strengthen the estimates of the gradient and the rotation parameters. Moreover, symmetry constraints can be imposed directly in the filter, further strengthening the solution.

Sonnabend, David↗

Cryogenic optical systems and instruments IV; Proceedings of the Meeting, San Diego, CA, July 10-12, 1990

Consideration is given to cryogenic system design and optical technology; cryogenic instruments, sensors, and detectors; space cryogenic dewars and coolers; and cryogenic mechanisms, testing, and structures. Particular attention is given to mission optimization of the Space Infrared Telescope Facility (SIRTF), alternative aperture stop position designs for SIRTF, scaling laws for lightweight optics, evaluation of a far-infrared Ge:Ga multiplexed detector array, cryogenic limb array etalon spectrometer calibration, reliability growth of coolers for advanced optical systems and instruments, flight-qualified solid argon cooler for the BBXRT instrument, precision mechanisms for optical alignments at cryogenic temperatures, versatile cryogenic rotary-positioning systems, and optical alignments of the Cosmic Background Explorer observatory.

Melugin, Ramsey K.↗

Heat pipes for wing leading edges of hypersonic vehicles

Wing leading edge heat pipes were conceptually designed for three types of vehicle: an entry research vehicle, aero-space plane, and advanced shuttle. A full scale, internally instrumented sodium/Hastelloy X heat pipe was successfully designed and fabricated for the advanced shuttle application. The 69.4 inch long heat pipe reduces peak leading edge temperatures from 3500 F to 1800 F. It is internally instrumented with thermocouples and pressure transducers to measure sodium vapor qualities. Large thermal gradients and consequently large thermal stresses, which have the potential of limiting heat pipe life, were predicted to occur during startup. A test stand and test plan were developed for subsequent testing of this heat pipe. Heat pipe manufacturing technology was advanced during this program, including the development of an innovative technique for wick installation.

Boman, B. L.↗