Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angular dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Top-of-Atmosphere Shortwave Broadband Observed Radiance and Estimated Irradiance over Polar Regions from Clouds and the Earth's Radiant Energy System (CERES) Instruments on Terra

Empirical angular distribution models for estimating top-of-atmosphere shortwave irradiances from radiance measurements over permanent snow, fresh snow and sea ice are developed using CERES measurements on Terra. Permanent snow angular distribution models depend on cloud fraction, cloud optical thickness, and snow brightness. Fresh snow and sea ice angular distribution models depend on snow and sea ice fraction, cloud fraction, cloud optical thickness, and snow and ice brightness. These classifications lead to 10 scene types for permanent snow and 25 scene types for fresh snow and sea ice. The average radiance over clear-sky permanent snow is more isotropic with satellite viewing geometry than that over overcast permanent snow. On average, the albedo of clear-sky permanent snow varies from 0.65 to 0.68 for solar zenith angles between 60$logical and\circ$ and 80 deg, while the corresponding albedo of overcast scenes varies from 0.70 to 0.73. Clear-sky permanent snow albedos over Antarctica estimated from two independent angular distribution models are consistent to within 0.6%, on average. Despite significant variability in sea ice optical properties with season, the estimated mean relative albedo error is -1 % for very dark sea ice and 0.1% for very bright sea ice when albedos derived from different viewing angles are averaged. The estimated regional root-mean-square (RMS) relative albedo error is 5.6% and 2.6% when the sea ice angular distribution models are applied to a region that contains very dark and very bright sea ice, respectively. Similarly, the estimated relative albedo bias error for fresh snow is -0.1% for very dark snow.

Kato, S.↗

Constraints on Cosmological Parameters From The Sunyaev-Zel'dovich Effect and Thermal Bremsstrahlung

We discuss the possibility of constraining cosmological parameters using the Sunyaev-Zel'dovich (SZ) effect and thermal bremsstrahlung caused by intra-cluster gas in clusters of galaxies. The new generation of X-ray satellites and ground based interferometers dedicated to SZ observations will enable one to reduce uncertainties in these measurements, and thus make this method potentially quite promising in the near future. The importance of this method is that, unlike most other methods, it is based on physical principles, no 'standard candles' or 'rulers' needed. We estimate the accuracy achievable in the determination of the matter density, OMEGA(sub m), the cosmological constant, OMEGA(sub LAMBDA), and the Hubble constant, h, using the redshift dependence of the angular diameter distance derived from observations in the near future. We demonstrate that constraints from the angular diameter distance are orthogonal to those from Cosmic Microwave Background (CMB) fluctuations in the parameter space defined by OMEGA(sub m), OMEGA(sub LAMBDA), and h. Assuming a statistical error of five percent in the angular diameter distance for each cluster in a sample of five hundred clusters, we show that the redshift dependence of the angular diameter distance combined with constraints from CMB fluctuations can put stringent constraints on OMEGA(sub m) (+/- 0.03), OMEGA(sub LAMBDA) (+/- 0.03) and h (+/- 0.03, 3(sigma) errors). We also show that, with as few as 50 clusters between redshifts 0.01 and 1.5 with an assumed 10% statistical error in the angular diameter distance determination, one can distinguish between models with zero cosmological constant and spatially flat models with a cosmological constant with high confidence level (independently from the supernova results) and put meaningful constraints on OMEGA(sub m) (+/- 0.01), OMEGA(sub LAMBDA) (+/- 0.01) and h (+/- 0.01, 3(sigma) errors). With the expected advances in observational technology, we will be limited by systematic errors. We discuss the sources of systematic errors and how they can be reduced.

Molnar, S. M.↗

Ion guiding accompanied by formation of neutrals in polyethylene terephthalate polymer nanocapillaries: Further insight into a self-organizing process

A relatively large yield of neutralized atoms was observed when 3 keV Ar{sup 7+} ions were guided trough polyethylene terephthalate nanocapillaries. Time and deposited-charge dependence of the angular distribution of both the guided ions and the neutrals was measured simultaneously using a two-dimensional multichannel plate detector. The yield of neutrals increased significantly faster than that of guided ions and saturated typically at a few percent level. In accordance with earlier observations, both the yield and the mean emission angle of the guided ions exhibited strong oscillations. For the atoms, the equilibrium was achieved not only faster, but also without significant oscillations in yield and angular position. A phase analysis of these time dependencies provides insight into the dynamic features of the self-organizing mechanisms, which leads to ion guiding in insulating nanocapillaries.

36 MATERIALS SCIENCE↗

A 2-D/1-D transverse leakage approximation based on azimuthal, Fourier moments

Here, the MPACT code being developed collaboratively by Oak Ridge National Laboratory and the University of Michigan is the primary deterministic neutron transport solver within the Virtual Environment for Reactor Applications Core Simulator (VERA-CS). In MPACT, the two-dimensional (2-D)/one-dimensional (1-D) scheme is the most commonly used method for solving neutron transport-based three-dimensional nuclear reactor core physics problems. Several axial solvers in this scheme assume isotropic transverse leakages, but work with the axial S N solver has extended these leakages to include both polar and azimuthal dependence. However, explicit angular representation can be burdensome for run-time and memory requirements. The work here alleviates this burden by assuming that the azimuthal dependence of the angular flux and transverse leakages are represented by a Fourier series expansion. At the heart of this is a new axial SN solver that takes in a Fourier expanded radial transverse leakage and generates the angular fluxes used to construct the axial transverse leakages used in the 2-D-Method of Characteristics calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Refinement of a formula for decay after weak coherent excitation of a sphere

A new formula has been given recently by A.A. Svidzinsky and M.O. Scully to describe the temporal evolution of the excitation function beta(t,r{sup -}>) in a large sphere satisfying the Markov condition after excitation by a single photon. This formula is based on a physically reasonable Ansatz from which differential equations are inferred for the undetermined radial functions in the Ansatz. The solution to these differential equations leads to the formula for beta. Numerical calculations from this formula yield a value approx10% for the maximum probability of occupancy of secondary excited states. In this paper, we refine the formula of Svidzinsky and Scully by allowing the radial functions in the Ansatz to depend on the angular index l of the spherical Bessel functions. By using the Debye formula for the asymptotic behavior of j{sub l}(u) for large l as well as u, we obtain differential equations in each angular sector, similar to theirs but with a dependence on l. The solution to these equations yields our improved formula, from which we calculate 17.1% for the maximum probability of secondary excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular-planar CMB power spectrum

Gaussianity and statistical isotropy of the Universe are modern cosmology's minimal set of hypotheses. In this work we introduce a new statistical test to detect observational deviations from this minimal set. By defining the temperature correlation function over the whole celestial sphere, we are able to independently quantify both angular and planar dependence (modulations) of the CMB temperature power spectrum over different slices of this sphere. Given that planar dependence leads to further modulations of the usual angular power spectrum C{sub l}, this test can potentially reveal richer structures in the morphology of the primordial temperature field. We have also constructed an unbiased estimator for this angular-planar power spectrum which naturally generalizes the estimator for the usual C{sub l}'s. With the help of a chi-square analysis, we have used this estimator to search for observational deviations of statistical isotropy in WMAP's 5 year release data set (ILC5), where we found only slight anomalies on the angular scales l=7 and l=8. Since this angular-planar statistic is model-independent, it is ideal to employ in searches of statistical anisotropy (e.g., contaminations from the galactic plane) and to characterize non-Gaussianities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE IMPACT OF HOT JUPITERS ON THE SPIN-DOWN OF THEIR HOST STARS

We present a numerical magnetohydrodynamic study of the dependence of stellar mass and angular momentum loss rates on the orbital distance to close-in giant planets. We find that the mass loss rate drops by a factor of {approx}1.5-2, while the angular momentum loss rate drops by a factor of {approx}4 as the distance decreases past the Alfven surface. This reduction in angular momentum loss is due to the interaction between the stellar and planetary Alfven surfaces, which modifies the global structure of the stellar corona and stellar wind on the hemisphere facing the planet, as well as on the opposite hemisphere. The simulation also shows that the magnitude of change in angular momentum loss rate depends mostly on the strength of the planetary magnetic field and not on its polarity. The interaction, however, begins at greater separation if the overall field topology of the star and the planet are anti-aligned. Our results are consistent with evidence for excess angular momentum in stars harboring close-in giant planets and show that the reduction in wind-driven angular momentum loss can compete with, and perhaps dominate, spin-up due to tidal interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

Expressing the equation of state parameter in terms of the three dimensional cosmic shear

We study the functional dependence of the spin-weighted angular moments of the two-point correlation function of the three dimensional cosmic shear on the expansion history of the universe. We first express the redshift dependent total equation of state parameter in terms of the growing mode of the gauge invariant metric perturbation in the conformal-Newtonian gauge for the case of adiabatic perturbations. We then express the redshift dependent angular moments of the shear two-point correlation function as an integral in terms of the metric perturbation. We present the final explicit expression for the case of a Harrison-Zeldovich spectrum of primordial perturbations. Our analysis is restricted to the linear regime. We use our results to make a preliminary study of the required sensitivity that will allow cosmic shear observations to add significant information about the expansion history of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

ISOTROPY IN THE TWO-POINT ANGULAR CORRELATION FUNCTION OF THE COSMIC MICROWAVE BACKGROUND

We study the directional dependence of the angular two-point correlation function in maps of the cosmic microwave background (CMB). We propose two new statistics: one which measures the correlation of each point in the sky with a ring of points separated an angle {theta} away, and a second one that measures the missing angular correlation above 60 deg as a function of direction. Using these statistics, we find that most of the low power in cut-sky maps measured by the Wilkinson Microwave Anisotropy Probe experiment comes from unusually low contributions from the directions of the lobes of the quadrupole and the octupole. These findings may aid a future explanation of why the CMB exhibits low power at large angular scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular distribution of gamma-ray emission from velocity-dependent dark matter annihilation in subhalos

We consider the effect of velocity-dependent dark matter annihilation on the angular distribution of gamma rays produced in dark matter subhalos. We assume that the dark matter potential is spherically symmetric, characterized by a scale radius and scale density, and the velocity distribution is isotropic. We find that the effect of velocity-dependent dark matter annihilation is largely determined by dimensional analysis; the angular size of gamma-ray emission from an individual subhalo is rescaled by a factor which depends on the form of the dark matter distribution, but not on the halo parameters, while the relative normalization of the gamma-ray flux from different mass subhalos is rescaled by a factor which depends on the halo parameters, but not on the form of the dark matter distribution. We apply our results to a Navarro-Frenk-White profile for the case of an individual subhalo and comment on the application of these results to a distribution of subhalos.

79 ASTRONOMY AND ASTROPHYSICS↗

The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry

Purpose: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. Methods: The DMG is an array of 128 phosphor implanted n{sup +} strips on a p-type Si wafer. The sensitive area defined by a single n{sup +} strip is 20x2000 {mu}m{sup 2}. The Si wafer is 375 {mu}m thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S{sub cp}) of the SRS cones. Comparisons were made with the EBT2 film and standard S{sub cp} values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. Results: The dose per pulse dependency of the DMG was found to be <5% for a dpp change of 7.5 times. The angular response of the detector was investigated in the azimuthal and polar directions. The maximum polar angular response was 13.8% at the gantry angle of 320 deg., which may be partly due to the phantom geometry. The maximum azimuthal angular response was 15.3% at gantry angles of 90 deg. and 270 deg. The angular response at the gantry angle of 180 deg. was 6.3%. A correction function was derived to correct for the angular dependence of the detector, which takes into account the contribution of the azimuthal and polar angular response at different treatment couch positions. The maximum positioning errors due to collimator, gantry, and couch rotation were 0.2{+-}0.1, 0.4{+-}0.1, and 0.4{+-}0.2 mm, respectively. The SRS cone S{sub cp} agrees very well with the standard data with an average difference of 1.2{+-}1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. Conclusions: The DMG was investigated for dose per pulse and angular dependency. Its application to SRS/SRT delivery verification was demonstrated. The DMG with its high spatial resolution and real time capability allows measurement of dose profiles for cone applicators down to 5 mm in diameter, both accurately and rapidly as required in typical SRS/SRT deliveries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bound states for a Coulomb-type potential induced by the interaction between a moving electric quadrupole moment and a magnetic field

We discuss the arising of bound states solutions of the Schrödinger equation due to the presence of a Coulomb-type potential induced by the interaction between a moving electric quadrupole moment and a magnetic field. Furthermore, we study the influence of the Coulomb-type potential on the harmonic oscillator by showing a quantum effect characterized by the dependence of the angular frequency on the quantum numbers of the system, whose meaning is that not all values of the angular frequency are allowed. -- Highlights: • Interaction between a moving electric quadrupole moment and a magnetic field. • Arising of bound states solutions due to the presence of a Coulomb-type potential. • Influence of the Coulomb-type potential on the harmonic oscillator. • Dependence of the angular frequency on the quantum numbers of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The tunneling magnetoresistance current dependence on cross sectional area, angle and temperature

The magnetoresistance of a MgO-based magnetic tunnel junction (MTJ) was studied experimentally. The magnetoresistance as a function of current was measured systematically on MTJs for various MgO cross sectional areas and at various temperatures from 7.5 to 290.1 K. The resistance current dependence of the MTJ was also measured for different angles between the two ferromagnetic layers. By considering particle and angular momentum conservation of transport electrons, the current dependence of magnetoresistance can be explained by the changing of spin polarization in the free magnetic layer of the MTJ. The changing of spin polarization is related to the magnetoresistance, its angular dependence and the threshold current where TMR ratio equals zero. A phenomenological model is used which avoid the complicated barrier details and also describes the data.

36 MATERIALS SCIENCE↗

SPT-3G D1: A Measurement of Secondary Cosmic Microwave Background Anisotropy Power

We report new measurements of millimeter-wave temperature power spectra in the angular multipole range $1700 \le \ell \le 11,000$ (wavelengths $13^\prime \gtrsim λ\gtrsim 2^\prime$). We use two years of data in three observing bands centered near 95, 150, and 220 GHz from the SPT-3G receiver on the South Pole Telescope that cover a 1646 deg$^2$ region of the Southern sky. Using the measured power spectra, we present constraints on the thermal and kinematic Sunyaev-Zel'dovich (SZ) effects, radio galaxies, and cosmic infrared background (CIB). We find that inferred SZ powers are dependent on the detailed modeling of the thermal SZ-CIB correlation, and to a lesser extent on the assumed angular dependence of the SZ spectra. We report constraints for simulation-based model templates as well as fits where the angular dependencies of the SZ and CIB power spectra are allowed to vary. In the latter case at $\ell=3000$, we find thermal SZ power at 143 GHz of $D_{3000}^{\rm tSZ} = 4.91\pm0.37\, μ{\rm K}^2$ and kinematic SZ power of $D_{3000}^{\rm kSZ} =1.75\pm0.86\, μ{\rm K}^2$. We use the measured kinematic SZ power to estimate the duration of reionization, noting that the reionization inferences are sensitive to the model choices and assumed level of homogeneous kinematic SZ power from the late-time universe. We find a 95% limit on the duration from an ionization fraction of 25% to 75% of $Δ^{50} z_{\rm re} <\,3.8$ based on a semi-analytic model, or a limit on the duration from an ionization fraction of 5% to 95% of $Δ^{90} z_{\rm re} <\,6.1$ based on the AMBER simulations.

Chaubal, P. [Melbourne U.]↗

Measuring pacemaker dose: A clinical perspective

Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

Angular Momentum Variation of the Milky Way Thick Disk: The Dependence of Chemical Abundance and Evidence of the Inside-out Formation Scenario

We investigate the angular momentum of mono-abundance populations (MAPs) of the Milky Way thick disk by using a sample of 26,076 giant stars taken from APOGEE Data Release (DR) 17 and Gaia early DR3. The vertical and perpendicular angular momentum components, L Z and L P , of the MAPs in narrow bins have significant variations across the [α/M]–[M/H] plane. L Z and L P systematically change with [M/H] and [α/M] and can be alternatively quantified by the chemical gradients: d[M/H]/dL Z = 1.2 × 10 -3 dex kpc -1 km -1 s, d[M/H]/dL P = -5.0 × 10 -3 dec kpc -1 km -1 s, and d[α/M]/dL Z = -3.0 × 10 -4 dex kpc -1 km -1 s, d[α/M]/dL P = 1.2 × 10 -3 dec kpc -1 km -1 s. These correlations can also be explained as the chemical dependence of the spatial distribution shape of the MAPs. We also exhibit the corresponding age dependence of the angular momentum components. Under the assumption that the guiding radius (R g ) is proportional to L Z , this provides direct observational evidence of the inside-out structure formation scenario of the thick disk, with dR g /dAge = -1.9 kpc Gyr -1 . The progressive changes in the disk thickness can be explained by the upside-down formation or/and the consequent kinematical heating.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the divergence of fast electrons in laser-irradiated spherical targets

In recent experiments using directly driven spherical targets on the OMEGA laser system, the energy in fast electrons was found to reach ~1% of the laser energy at an irradiance of ~1.1 × 10 15 W/cm 2 . The fraction of these fast electrons absorbed in the compressed fuel shell depends on their angular divergence. This paper describes measurements of this divergence deduced from a series of shots where Mo-coated shells of increasing diameter (D) were suspended within an outer CH shell. The intensity of the Mo–Kα line and the hard x-ray radiation were found to increase approximately as ~D2, indicating wide divergence of the fast electrons. Alternative interpretations of these results (electron scattering, radiation excitation of Kα, and an electric field due to return current) are shown to be unimportant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗