Search NASA⌕ Search

SEARCH · Search NASA

Results for “Background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

LA-ICP/MS Analysis of Plastics as a Method to Support Polymer Assay in the Assessment of Materials for Low Background Detectors

Ultra low-background radiation measurements are essential to several large-scale physics investigations, such as those involving neutrinoless double-beta decay, dark matter detection (such as SuperCDMS), and solar neutrino detection. There is a need for electrically and thermally insulating dielectric materials with extremely low-background radioactivity for detector construction. This need is best met with plastics. Most currently available structural plastics have milliBecquerel-per-kilogram total intrinsic radioactivity. Modern low-level detection systems require a large variety of plastics with low microBecquerel-per-kilogram levels. However, the assay of polymer materials for extremely low levels of radioactive elements, uranium and thorium in particular, presents new challenges. It is only recently that any certified reference materials (CRMs) for toxic metals such as lead or cadmium in plastics have become available. However, there are no CRMs for uranium or thorium in thermoplastics. This paper discusses our assessment of the use of laser ablation (LA) for sampling and inductively coupled plasma mass spectrometry (ICP-MS) for analysis of polyethylene (PE) samples, with an emphasis on uranium determination. Using a CRM for lead in PE, we examine LA and ICP-MS parameters that determine whether the total atom efficiencies for uranium and lead are similar, and explore methods to use the lead content in a plastic as part of the process of estimating or determining the uranium content by LA-ICP-MS.

laser ablation↗

Influence of Background H{sub 2}O on the Collision-Induced Dissociation Products Generated from [UO{sub 2}NO{sub 3}]{sup +}

Developing a comprehensive understanding of the reactivity of uranium-containing species remains an important goal in areas ranging from the development of nuclear fuel processing methods to studies of the migration and fate of the element in the environment. Electrospray ionization (ESI) is an effective way to generate gas-phase complexes containing uranium for subsequent studies of intrinsic structure and reactivity. Recent experiments by our group have demonstrated that the relatively low levels of residual H{sub 2}O in a 2-D, linear ion trap (LIT) make it possible to examine fragmentation pathways and reactions not observed in earlier studies conducted with 3-D ion traps (Van Stipdonk et al. J. Am. Soc. Mass Spectrom. 14, 1205–1214, 2003). In the present study, we revisited the dissociation of complexes composed of uranyl nitrate cation [U{sup VI}O{sub 2}(NO{sub 3})]{sup +} coordinated by alcohol ligands (methanol and ethanol) using the 2-D LIT. With relatively low levels of background H{sub 2}O, collision-induced dissociation (CID) of [U{sup VI}O{sub 2}(NO{sub 3})]{sup +} primarily creates [UO{sub 2}(O{sub 2})]{sup +} by the ejection of NO. However, CID (using He as collision gas) of [U{sup VI}O{sub 2}(NO{sub 3})]{sup +} creates [UO{sub 2}(H{sub 2}O)]{sup +} and UO{sub 2}{sup +} when the 2-D LIT is used with higher levels of background H{sub 2}O. Based on the results presented here, we propose that product ion spectrum in the previous experiments was the result of a two-step process: initial formation of [U{sup VI}O{sub 2}(O{sub 2})]{sup +} followed by rapid exchange of O{sub 2} for H{sub 2}O by ion-molecule reaction. Our experiments illustrate the impact of residual H{sub 2}O in ion trap instruments on the product ions generated by CID and provide a more accurate description of the intrinsic dissociation pathway for [U{sup VI}O{sub 2}(NO{sub 3})]{sup +}. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Walking solutions in the string background dual to N=1 SQCD-like theories

A new solution in the string background dual to N=1 SQCD-like theories is presented. The gauge coupling in this solution has walking property. The Wilson loop calculations show that quark anti-quark potential makes phase transitions. Additionally the effect of flavours on other solutions in this background is investigated by considering some unflavoured solutions and perturbing them with small parameter x=(N{sub f})/(N{sub c})

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Hamiltonian formalism for scalar fields coupled to gravity in a cosmological background

A novel routine to investigate the scalar fields in a cosmological context is discussed in the framework of the Hamiltonian formalism. Starting from the Einstein–Hilbert action coupled to a Lagrangian density that contains two components–one corresponding to a scalar field Lagrangian, L{sub ϕ}, and another that depends on the scale parameter, L{sub a}–one can identify a generalized Hamiltonian density from which first-order dynamical equations can be obtained. This set up corresponds to the dynamics of Friedmann–Robertson–Walker models in the presence of homogeneous fields embedded into a generalized cosmological background fluid in a system that evolves all together isentropically. Once the generalized Hamiltonian density is properly defined, the constraints on the gravity–matter–field system are straightforwardly obtained through the first-order Hamilton equations. The procedure is illustrated for three examples of cosmological interest for studies of the dark sector: real scalar fields, tachyonic fields and generalized Born–Infeld tachyonic fields. The inclusion of some isentropic fluid component into the Friedmann equation allows for identifying an exact correspondence between the dark sector underlying scalar field and an ordinary real scalar field dynamics. As a final issue, the Hamiltonian formulation is used to set the first-order dynamical equations through which one obtains the exact analytical description of the cosmological evolution of a generalized Chaplygin gas (GCG) with dustlike matter, radiation or curvature contributions. Model stability in terms of the square of the sound velocity, c{sub s}{sup 2}, cosmic acceleration, q, and conditions for inflation are discussed. -- Highlights: •The Hamiltonian formalism for scalar fields coupled to gravity in a cosmological background is constructed. •Real scalar, tachyonic and generalized Born–Infeld tachyonic-type fields are considered. •An extended formulation of the Hamilton–Jacobi description of the dark sector dynamics driven by scalar fields is obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Breathers and localized solitons for the Hirota–Maxwell–Bloch system on constant backgrounds in erbium doped fibers

In nonlinear erbium doped fibers, the Hirota–Maxwell–Bloch system with higher order effects usually governs the propagation of ultrashort pulses. New soliton solutions for this system are constructed on the constant backgrounds including one and two breathers and first and higher order localized soliton solutions. Considering the influence of higher order effects, propagation properties of those soliton solutions are discussed. -- Highlights: •The AB and Ma-breathers are derived on the constant backgrounds. •Dynamic features of two-breathers are discussed. •Localized solutions are generated from two different ways.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Background gauge renormalization and BRST identities

We show how the BRST identities can be used to control the renormalization of the background gauge in QCD, in spite of the fact that certain one-particle reducible graphs have to be omitted in general. We obtain the all order renormalized effective action for the background field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Boson–fermion duality in a gravitational background

We study the 2+1 dimensional boson–fermion duality in the presence of background curvature and electromagnetic fields. The main players are, on the one hand, a massive complex |ϕ|{sup 4} scalar field coupled to a U(1) Maxwell–Chern–Simons gauge field at level 1, representing a relativistic composite boson with one unit of attached flux, and on the other hand, a massive Dirac fermion. We show that, in a curved background and at the level of the partition function, the relativistic composite boson, in the infinite coupling limit, is dual to a short-range interacting Dirac fermion. The coupling to the gravitational spin connection arises naturally from the spin factors of the Wilson loop in the Chern–Simons theory. A non-minimal coupling to the scalar curvature is included on the bosonic side in order to obtain agreement between partition functions. Although an explicit Lagrangian expression for the fermionic interactions is not obtained, their short-range nature constrains them to be irrelevant, which protects the duality in its strong interpretation as an exact mapping at the IR fixed point between a Wilson–Fisher–Chern–Simons complex scalar and a free Dirac fermion. We also show that, even away from the IR, keeping the |ϕ|{sup 4} term is of key importance as it provides the short-range bosonic interactions necessary to prevent intersections of worldlines in the path integral, thus forbidding unknotting of knots and ensuring preservation of the worldline topologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of ultralow-background cryogenic calorimeters for the measurement of surface α contamination

Next-generation experiments searching for rare events must satisfy increasingly stringent requirements on the bulk and surface radioactive contamination of their active and structural materials. The measurement of surface contamination is particularly challenging, as no existing technology is capable of separately measuring parts of the 232 Th and 238 U decay chains that are commonly found to be out of secular equilibrium. We will present the results obtained with a detector prototype consisting of 8 silicon wafers of 150mm diameter instrumented as bolometers and operated in a low-background dilution refrigerator at the Gran Sasso Underground Laboratory of INFN, Italy. Furthermore, the prototype was characterized by a baseline energy resolution of few keV and a background <100nBq/cm 2 in the full range of α energies, obtained with simple procedures for cleaning of all employed materials and no specific measures to prevent recontamination. Such performance, together with the modularity of the detector design, demonstrate the possibility to realize an alpha detector capable of separately measuring all alpha emitters of the 232 Th and 238 U chains, possibly reaching a sensitivity of few nBq/cm 2 .

07 ISOTOPE AND RADIATION SOURCES↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Muon-induced backgrounds in the CUORICINO experiment

To better understand the contribution of cosmic ray muons to the CUORICINO background, ten plastic scintillator detectors were installed at the CUORICINO siteand operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV.kg.yr) (95percent c.l.) was obtained on the cosmicray induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Origin of the background absorption in carbon nanotubes: Phonon-assisted excitonic continuum

Excitonic effects in 1D semiconductors can be qualitatively different from those in higher dimensions. In particular, the Sommerfeld factor, the ratio of the above-band-edge excitonic continuum absorption to free electron-hole pair generation, has been shown to be less than 1 (suppressed) in 1D systems while it is larger than 1 (enhanced) in 2D and 3D systems. Strong continuum suppression indeed exists in semiconducting single-wall carbon nanotubes, a prototypical 1D semiconductor. However, absorption spectra for carbon nanotubes are typically fit with a combination of Lorentzians and a polynomial background baseline with little physical meaning. We performed absorption measurements in aligned single-chirality (6,5) carbon nanotube films. The obtained spectra were fit with our theoretical model obtained by solving the Boltzmann scattering equation involving fifty-nine different types of transitions among three different types of quasiparticles. Specifically, we took into account microscopic interactions between photons, phonons, and excitons, including their dispersions, which unambiguously demonstrated that the background absorption is due to phonon-assisted transitions from the semiconductor vacuum to finite-momentum continuum states of excitons. The excellent agreement we obtained between experiment and theory suggests that our numerical technique can be seamlessly extended to compute strongly out-of-equilibrium many-body dynamics and time-resolved spectra in low-dimensional materials.

36 MATERIALS SCIENCE↗

Thirdhand tobacco smoke exposure increases the genetic background-dependent risk of pan-tumor development in Collaborative Cross mice

Increasing evidence has shown that thirdhand smoke (THS) exposure is likely to induce adverse health effects. An important knowledge gap remains in our understanding of THS exposure related to cancer risk in the human population. Population-based animal models are useful and powerful in investigating the interplay between host genetics and THS exposure on cancer risk. Here, we used the Collaborative Cross (CC) mouse population-based model system, which recapitulates the genetic and phenotypic diversity observed in the human population, to assess cancer risk after a short period of exposure, between 4 and 9 weeks of age. Eight CC strains (CC001, CC019, CC026, CC036, CC037, CC041, CC042 and CC051) were included in our study. We quantified pan-tumor incidence, tumor burden per mouse, organ tumor spectrum and tumor-free survival until 18 months of age. At the population level, we observed a significantly increased pan-tumor incidence and tumor burden per mouse in THS-treated mice as compared to the control (p = 3.04E-06). Lung and liver tissues exhibited the largest risk of undergoing tumorigenesis after THS exposure. Tumor-free survival was significantly reduced in THS-treated mice compared to control (p = 0.044). At the individual strain level, we observed a large variation in tumor incidence across the 8 CC strains. CC036 and CC041 exhibited a significant increase in pan-tumor incidence (p = 0.0084 and p = 0.000066, respectively) after THS exposure compared to control. We conclude that early-life THS exposure increases tumor development in CC mice and that host genetic background plays an important role in individual susceptibility to THS-induced tumorigenesis. Genetic background is an important factor that should be taken into account when determining human cancer risk of THS exposure.

60 APPLIED LIFE SCIENCES↗

Incorporating civilian radioxenon background estimates in anomaly detection

A nuclear explosion screening exercise in 2023 (Maurer et al., 2023) found challenges with discerning anomalous radioxenon activity concentrations relative to elevated background concentrations. Research has continued into methods to detect anomalous radioxenon concentrations by comparing samples to estimates of atmospheric radioxenon background concentrations caused by releases at nuclear reactors or medical isotope production facilities. A new approach estimates the sample concentrations using time-varying radioxenon release rates obtained using optimization techniques that constrain the facility release rates to plausible amounts based on historical data or facility knowledge. The purpose of the optimization is to determine whether any combination of plausible release rates from emitting facilities can explain a series of radioxenon measurements at one or more sampling stations. A case study uses radioxenon data collected at three locations in western Europe for a month in 2021 and considers releases from 77 locations. Fewer samples are identified as being anomalous using a simplistic flagging rule than from an application of the current International Monitoring System (IMS) activity concentration-level rule.

Environmental sciences↗

A low-background γγ-coincidence spectrometer for radioisotope studies

The performance of a new, low-background NaI(Tl) spectrometer, based on γγ-coincidence counting, is discussed. We present experimental coincidence efficiencies, timing resolutions, background count rates, and minimum detectable activities. The spectrometer has been simulated using Geant4, and the results are used for estimating coincidence efficiencies for volume sources. To test the device, we measured the cosmogenic 26 Al activity in a small (17.7 g) meteorite fragment. Here, we find a value of 52.9±7.8 dpm / kg, in agreement with the activity measured previously in a much larger fragment of the same meteorite using a HPGe detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of light backgrounds from relativistic electrons in air light-guides

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Moller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Moller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass spectrometric investigations into 3D printed parts to assess radiopurity as ultralow background materials for rare event physics detectors

The mass concentrations of 232 Th and 238 U in several 3D printing filaments and printed polymer parts are reported as measures of their radiopurity. In order to minimize background signals in rare event physics detectors, radiopure polymers are necessary as dielectric and structural materials in their construction. New data are reported for polyvinylidene fluoride (PVDF), polyphenylene sulfide (PPS), and two forms of polyetherimide (PEI, branded ULTEM 1010 and 9085). Data for starting filaments and both simple and complex printed parts are reported. PVDF filaments and simple printed beads, were found to have values of approximately 30 and 50 pg g -1 for 232 Th and 238 U, respectively, while a more complex spring clip part had slightly elevated 232 Th levels of 65 pg g -1 , with 238 U remaining at 50 pg g -1 . PPS filament was found to have concentrations of 270 and 710 pg g -1 for 232 Th and 238 U, respectively, and were not chosen to be printed as those levels were already higher than other material options. ULTEM 1010 filaments and printed complex spring clip parts were found to have concentrations of around 5 and 7 pg g -1 for 232 Th and 238 U, respectively, illustrating no significant contamination from the printing process. ULTEM 9085 filaments were found to have concentrations of around 9 and 5 pg g -1 for 232 Th and 238 U, respectively, while the printed complex spring clip part was found to have slightly elevated concentrations of 25 and 7 pg g -1 for 232 Th and 238 U, respectively. All these results were obtained using a novel dry ashing method in crucibles constructed of ultralow background electroformed copper or, when applicable, microwave assisted wet ashing digestion. Samples and process blanks were spiked with 229 Th and 233 U as internal standards prior to dry/wet ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). In order to maintain high radiopurity levels, pre-cleaning the filaments before printing and post-cleaning the parts is recommended, although the printing process itself has shown to contribute very minute amounts of radiocontaminants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In search of chiral magnetic effect: Separating flow-driven background effects and quantifying anomaly-induced charge separations

Here we report our recent progress on the search of Chiral Magnetic Effect (CME) by developing new measurements as well as by hydrodynamic simulations of CME and background effects, with both approaches addressing the pressing issue of separating flow-driven background contributions and possible CME signal in current heavy ion collision measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Background Free‐Tropospheric Ice Nucleating Particle Concentrations at Mixed‐Phase Cloud Conditions

Abstract Clouds containing ice are vital for precipitation formation and are important in determining the Earth's radiative budget. However, primary formation of ice in clouds is not fully understood. In the presence of ice nucleating particles (INPs), the phase change to ice is promoted, but identification and quantification of INPs in a natural environment remains challenging because of their low numbers. In this paper, we quantify INP number concentrations in the free troposphere (FT) as measured at the High Altitude Research Station Jungfraujoch (JFJ), during the winter, spring, and summer of the years 2014–2017. INPs were measured at conditions relevant for mixed‐phase cloud formation at T = 241/242 K. To date, this is the longest timeline of semiregular measurements akin to online INP monitoring at this site and sampling conditions. We find that INP concentrations in the background FT are on average capped at 10/stdL (liter of air at standard conditions [ T = 273 K and p = 1013 hPa]) with an interquartile range of 0.4–9.6/stdL, as compared to measurements during times when other air mass origins (e.g., Sahara or marine boundary layer) prevailed. Elevated concentrations were measured in the field campaigns of 2016, which might be due to enhanced influence from Saharan dust and marine boundary layer air arriving at the JFJ. The upper limit of INP concentrations in the background FT is supported by measurements performed at similar conditions, but at different locations in the FT, where we find INP concentrations to be below 13/stdL most of the time.

54 ENVIRONMENTAL SCIENCES↗