Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Spatial distribution of the charged particles and potentials during beam extraction in a negative-ion source

We report on the characteristics of the electronegative plasma in a large-scale hydrogen negative ion (H{sup -}) source. The measurement has been made with a time-resolved Langmuir probe installed in the beam extraction region. The H{sup -} density is monitored with a cavity ring-down system to identify the electrons in the negative charges. The electron-saturation current decreases rapidly after starting to seed Cs, and ion-ion plasma is observed in the extraction region. The H{sup -} density steps down during the beam extraction and the electron density jumps up correspondingly. The time integral of the decreasing H{sup -} charge density agrees well with the electron charge collected with the probe. The agreement of the charges is interpreted to indicate that the H{sup -} density decreasing at the beam extraction is compensated by the electrons diffusing from the driver region. In the plasmas with very low electron density, the pre-sheath of the extraction field penetrates deeply inside the plasmas. That is because the shielding length in those plasmas is longer than that in the usual electron-ion plasmas, and furthermore the electrons are suppressed to diffuse to the extraction region due to the strong magnetic field.

43 PARTICLE ACCELERATORS↗

Properties of the electron beam in a room-temperature electron beam ion source investigated by position sensitive x-ray detection

The evolution of the charge state distribution inside an electron beam ion source or trap (EBIS/T) is determined by interactions of the electron beam with the ions in the trap region. Hence, detailed information about the electron beam is required for evaluations of spectroscopic and ion extraction measurements performed at EBIS/T facilities. This article presents the results of investigations on the electron beam properties of an ion source of the Dresden EBIS type. For the first time theoretical predictions of the shape of the beam were tested for a noncryogenic EBIS working with low magnetic flux densities provided by permanent magnets. Position and width of the electron beam were measured at different electron energies showing an oscillation in the beam structure. At an energy of E{sub e}=16 keV and an emission current of I{sub e}=30 mA the beam is compressed to a radius of r{sub e}=57 {mu}m (80% current). This refers to an average current density of <j{sub e}>=232 A/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Boersch effect in a picosecond pulsed electron beam emitted from a semiconductor photocathode

The space charge effect has been clearly observed in the energy distributions of picosecond pulse beams from a spin-polarized electron microscope, and was found to depend upon the quantity of charge per pulse. The non-linear phenomena associated with this effect have also been replicated in beam simulations that take into account of a three-dimensional space charge. The results show that a charge of 500 aC/pulse provides the highest brightness with a 16-ps pulse duration, a 30-keV beam energy, and an emission spot of 1.8 μm. Furthermore, the degeneracy of the wave packet of the pulsed electron beam has been evaluated to be 1.6 × 10{sup −5} with a charge of 100 aC/pulse, which is higher than that for a continuously emitted electron beam despite the low beam energy of 30 keV. The high degeneracy and high brightness contribute to the realization of high temporal and energy resolutions in low-voltage electron microscopy, which will serve to reduce radiolysis damage and enhance scattering contrast.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SHarD: A beam dynamics simulation code for dielectric laser accelerators based on spatial harmonic field expansion

In order to demonstrate acceleration of electrons to relativistic scales by an on chip dielectric laser accelerator (DLA), a ponderomotive focusing scheme capable of capturing and transporting electrons through nanometer-scale apertures over extended interaction lengths has been proposed. Here we present a Matlab-based numerical code (SHarD) utilizing a spatial harmonic expansion of the fields within the dielectric structure to simulate the evolution of the beam phase space distribution in this scheme. The code can be used to optimize key-parameters for the accelerator performance such as the final energy, transverse spot size evolution and total number of electrons accelerated through currently fabricated structures. Eventually, the simulation model will be applied to inform the phase mask profile to be added to a pulse front tilt drive laser pulse using a liquid crystal mask in the experimental setup being assembled at UCLA Pegasus Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extricating New Physics Scenarios at DUNE with Higher Energy Beams

Here, the proposed Deep Underground Neutrino Experiment (DUNE) utilizes a wide-band on-axis tunable muon-(anti)neutrino beam with a baseline of 1300 km to search for CP violation with high precision. Given the long baseline, DUNE is also sensitive to effects due to matter induced non-standard neutrino interactions (NSI) which can interfere with the standard three-flavor oscillation paradigm. Hence it is desirable to design strategies to disentangle effects due to NSI from standard oscillations. In this article, we exploit the tunability of the DUNE neutrino beam over a wide-range of energies to devise an experimental strategy for separating oscillation effects due to NSI from the standard three- flavor oscillation scenario. Using χ 2 analysis, we obtain an optimal combination of beam tunes and distribution of run times in neutrino and anti-neutrino modes that would enable DUNE to isolate new physics scenarios from the standard. We can distinguish scenarios at 3σ (5σ) level for almost all (~50%) values of δ. To the best of our knowledge, our strategy is entirely new and has not been reported elsewhere.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Net-particle number fluctuations in a hydrodynamic description of heavy-ion collisions

Utilizing viscous hydrodynamic simulations of heavy-ion collisions, we study the behavior of cumulants of (net-)(anti)proton number distributions at RHIC beam energy scan energies, incorporating non-critical contributions like baryon conservation and excluded volume. The experimental data on net-proton cumulants at √S NN > 20 GeV are consistent with simultaneous effects of global baryon conservation and repulsive interactions in baryon sector, whereas the data at lower collision energies show possible indications for sizable attractive interactions among baryons. We discuss the behavior of factorial cumulants in addition to the ordinary cumulants, and also address the quantitative difference between proton and baryon number cumulants.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High intensity, plasma-induced electron emission from large area carbon nanotube array cathodes

The plasma-induced electron emission properties of large area carbon nanotube (CNT) array cathodes under different pulse electric fields were investigated. The formation and expansion of cathode plasmas were proved; in addition, the cathodes have higher emission current in the double-pulse mode than that in the single-pulse mode due to the expansion of plasma. Under the double-pulse electric field of 8.16 V/mum, the plasma's expansion velocity is about 12.33 cm/mus and the highest emission current density reached 107.72 A/cm{sup 2}. The Cerenkov radiation was used to diagnose the distribution of electron beams, and the electron beams' generating process was plasma-induced emission.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EMIL project at BESSY II: Beamline design and performance

The Energy Materials In-Situ Laboratory Berlin (EMIL) at BESSY-II is currently under construction. Two canted undulators for soft- and hard X-rays will be installed into the BESSY II storage ring in one straight section, complex beamlines with more than twenty optical elements will be set up and a new laboratory building attached to BESSY II will host three endstations and a large UHV-transfer system connecting various HV- and UHV-deposition systems. The undulators, UE48 and U17, provide a broad energy spectrum of 80 - 10000 eV, of which the harder radiation (>700 eV) is provided by a cryogenic in-vacuum device. Three monochromators (two plane grating monochromators (PGM) and one LN{sub 2}-cooled double crystal monochromator (DCM)) disperse the radiation into separate pathways of 65 m length, while downstream of the monochromators split-mirror chambers distribute the photon beam to one (or simultaneously to two) of five upcoming endstations. Three of these endstations are designed for the full energy range with spatial overlap of the soft and hard foci, whereas one endstation (PEEM) uses only the soft and another one (PINK) only the hard branch, respectively.

43 PARTICLE ACCELERATORS↗

Modulating charge transport via 2 MeV He + irradiation in VO 2

Vanadium dioxide (VO 2 ) is of interest for adaptive electronic applications such as neuromorphic neuristor devices and variable emissivity or tunable thermal control materials, thanks to its key property—a metal–insulator transition (MIT) at 68 °C that is accompanied by a dramatic change in electrical and optical properties. To improve performance in these roles, it is critical to develop approaches to engineer transport properties and the MIT behavior. While many documented techniques exist to modulate the MIT and film resistivities via lattice strain and chemical doping, less is known about the effects of ion irradiation on the intrinsic properties of VO 2 , despite the ability to control the spatial distribution of irradiation beams and the prevalence of high energy ion implantation in the semiconductor industry. The impact of irradiation of different acceleration energies on the responses of VO 2 is of specific interest, as charged particle energy generally impacts both the resulting defect profile and corresponding transport behavior. Here, we demonstrate that 2 MeV He ions at equivalent calculated displacements per atom, in two different types of films, can create remarkable changes to the nature of charge transport in VO 2 , especially in the low-temperature insulating phase. Simulation of resulting changes in electrical conductivity reveals that He ion irradiation offers a strategy to increase both oscillation frequency and the signal transmission. These results provide insights into the intentional design of defect populations to modulate transport for neuromorphic VO 2 devices.

Gurrola, Rebeca M. [Texas A & M Univ., College Sta↗

Development and validation of a critical gradient energetic particle driven Alfven eigenmode transport model for DIII-D tilted neutral beam experiments

Recent experiments with the DIII-D tilted neutral beam injection (NBI) varying the beam energetic particle (EP) source profiles have provided strong evidence that unstable Alfven eigenmodes (AE) drive stiff EP transport at a critical EP density gradient. Here the critical gradient is identified by the local AE growth rate being equal to the local ITG/TEM growth rate at the same low toroidal mode number. The growth rates are taken from the gyrokinetic code GYRO. Simulation show that the slowing down beam-like EP distribution has a slightly lower critical gradient than the Maxwellian. The ALPHA EP density transport code, used to validate the model, combines the low-n stiff EP critical density gradient AE mid-core transport with the energy independent high-n ITG/TEM density transport model controling the central core EP density profile. For the on-axis NBI heated DIII-D shot 146102, while the net loss to the edge is small, about half the birth fast ions are transported from the central core r/a < 0.5 and the central density is about half the slowing down density. Lastly, these results are in good agreement with experimental fast ion pressure profiles inferred from MSE constrained EFIT equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synergy of coupled kink and tearing modes in fast ion transport

One aspect of the interaction between fast ions and magnetohydrodynamic (MHD) instabilities is the fast ion transport. Coupled kink and tearing MHD instabilities have also been reported to cause fast ion transport. Recently, the 'kick' model has been developed to compute the evolution of the fast ion distribution from neutral beam injection using instabilities as phase-space resonance sources. Overall, the goal of this paper is to utilize the kick model to understand the physics of fast ion transport caused by the coupled kink and tearing modes. Soft x-ray diagnostics are used to identify the mode parameters in the National Spherical Torus Experiment. The comparison of neutron rates measured and computed from time-dependent TRANSP simulation with the kick model shows that the coupling of kink and tearing mode is important in determination of the fast ion transport. The numerical scan of the mode parameters shows that the relative phase of the kink and tearing modes and the overlapping of kink and tearing mode resonances in the phase space can affect the fast ion transport, suggesting that the synergy of the coupled modes may be causing the fast ion transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase matching in three-dimensional nonlinear photonic crystals

The coupled-wave equations of three-wave interactions are generalized into three dimensions. The reciprocal lattice vectors (RLVs) of three-dimensional (3D) nonlinear photonic crystals (NPCs) which show some unique properties are analyzed in detail as compared to those in one- and two-dimensional cases. It is proposed as an example that the cross-distributing conical harmonic beams can be obtained from the 3D NPC by intentionally using the proper RLVs. Some other possible applications are suggested at the end of discussion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental verification of gain drop due to general ion recombination for a carbon-ion pencil beam

Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity of ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-194: Analyzing the Effect of Range Shifter Air Gap On TPS Dose Modeling Accuracy in Superficial PBS Proton Therapy

Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dose optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-02: Feasibility of Optimization for Dynamic Trajectory Radiotherapy

Purpose: Over the last years, volumetric modulated arc therapy (VMAT) has been widely introduced into clinical routine using a coplanar delivery technique. However, VMAT might be improved by including dynamic couch and collimator rotations, leading to dynamic trajectory radiotherapy (DTRT). In this work the feasibility and the potential benefit of DTRT was investigated. Methods: A general framework for the optimization was developed using the Eclipse Scripting Research Application Programming Interface (ESRAPI). Based on contoured target and organs at risk (OARs), the structures are extracted using the ESRAPI. Sampling potential beam directions, regularly distributed on a sphere using a Fibanocci-lattice, the fractional volume-overlap of each OAR and the target is determined and used to establish dynamic gantry-couch movements. Then, for each gantry-couch track the most suitable collimator angle is determined for each control point by optimizing the area between the MLC leaves and the target contour. The resulting dynamic trajectories are used as input to perform the optimization using a research version of the VMAT optimization algorithm and the ESRAPI. The feasibility of this procedure was tested for a clinically motivated head and neck case. Resulting dose distributions for the VMAT plan and for the dynamic trajectory treatment plan were compared based on DVH-parameters. Results: While the DVH for the target is virtually preserved, improvements in maximum dose for the DTRT plan were achieved for all OARs except for the inner-ear, where maximum dose remains the same. The major improvements in maximum dose were 6.5% of the prescribed dose (66 Gy) for the parotid and 5.5% for the myelon and the eye. Conclusion: The result of this work suggests that DTRT has a great potential to reduce dose to OARs with similar target coverage when compared to conventional VMAT treatment plans. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Simulation and optical spectroscopy of a DC discharge in a CH{sub 4}/H{sub 2}/N{sub 2} mixture during deposition of nanostructured carbon films

Two-dimensional numerical simulations of a dc discharge in a CH{sub 4}/H{sub 2}/N{sub 2} mixture in the regime of deposition of nanostructured carbon films are carried out with account of the cathode electron beam effects. The distributions of the gas temperature and species number densities are calculated, and the main plasmachemical kinetic processes governing the distribution of methyl radicals above the substrate are analyzed. It is shown that the number density of methyl radicals above the substrate is several orders of magnitude higher than the number densities of other hydrocarbon radicals, which indicates that the former play a dominant role in the growth of nanostructured carbon films. The model is verified by comparing the measured optical emission profiles of the H(n ≡ 3), C{sub 2}{sup *}, CH*, and CN* species and the calculated number densities of excited species, as well as the measured and calculated values of the discharge voltage and heat fluxes onto the electrodes and reactor walls. The key role of ion–electron recombination and dissociative excitation of H{sub 2}, C{sub 2}H{sub 2}, CH{sub 4}, and HCN molecules in the generation of emitting species (first of all, in the cold regions adjacent to the electrodes) is revealed.

36 MATERIALS SCIENCE↗