Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

EnergyPlus™ [SWR-17-23]

Originally developed in 1999, an updated version 8.8.0 with bug fixes was released on September 30th, 2017. EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption—for heating, cooling, ventilation, lighting and plug and process loads—and water use in buildings. EnergyPlus is a console-based program that reads input and writes output to text files. It ships with a number of utilities including IDF-Editor for creating input files using a simple spreadsheet-like interface, EP-Launch for managing input and output files and performing batch simulations, and EP-Compare for graphically comparing the results of two or more simulations. Several comprehensive graphical interfaces for EnergyPlus are also available. DOE does most of its work with EnergyPlus using the OpenStudio® software development kit and suite of applications. DOE releases major updates to EnergyPlus twice annually.

Source record↗

Collaboration for Advanced Modeling of Particle Accelerators

The pverarching purpose is to accelerate and expand the scope of discoveries from high energy physics (HEP) particle accelerators by enabling the design of accelerators that are significantly more compact and cheaper to build and run. This will be realized through (i) developing high-performance computing (HPC) accelerator and beam modeling capabilities to design the full range of systems required (ii) developing community simulation ecosystems that seamlessly integrate accelerator elements to facilitate the design and control of next-generation accelerators.

43 PARTICLE ACCELERATORS↗

EnergyPlus™

Originally developed in 1999, an updated version 8.8.0 with bug fixes was released on September 30th, 2017. EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption—for heating, cooling, ventilation, lighting and plug and process loads—and water use in buildings. EnergyPlus is a console-based program that reads input and writes output to text files. It ships with a number of utilities including IDF-Editor for creating input files using a simple spreadsheet-like interface, EP-Launch for managing input and output files and performing batch simulations, and EP-Compare for graphically comparing the results of two or more simulations. Several comprehensive graphical interfaces for EnergyPlus are also available. DOE does most of its work with EnergyPlus using the OpenStudio® software development kit and suite of applications. DOE releases major updates to EnergyPlus twice annually.

Source record↗

Determination of a Generic Human Error Probability Distribution, Part 1: A Dynamic Formulation of SPAR-H

In almost all major nuclear power plants (NPP) events include a significant human error component. As an example, in Fukushima Daiichi (2011) nuclear meltdown, the human actions related to the high-pressure injection cooling strongly affected accident evolution. Furthermore, in the Three Mile Island accident (1979) (which was initiated by a stuck open valve and thus was triggered a loss of coolant accident) the unit operators made decisions based upon false assumptions that contributed negatively to the accident. Given these premises, the ability to accurately model human interactions with plant evolution and, in particular, dynamically calculate human error probability (HEP) plays a major role in a probabilistic risk analysis (PRA). Human reliability analysis (HRA) identifies and models the causes of human errors, and quantifies HEP by applying different methodologies. HRA methods identify errors and reflect on the understanding of error-prone people and systems. There are a number of HRA methods available that assist in identifying the vulnerabilities in the system and provide guidance in determining the HEP. HEP is the probability of a human failure event (HFE), and quantification of HEPs under various situations is utilized in PRA of large complex systems. One of the more prominent HRA methods is the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method that was developed to estimate HEPs for the use in the Standardized Plant Analysis Risk (SPAR) PRA models employed in U.S. NPPs. SPAR-H is implemented in U.S. NPPs by regulators at the U.S. Nuclear Regulatory Commission (NRC) to determine the HEP based on expert estimation through the use of calculation worksheets. In SPAR-H, the nominal HEPs (NHEPs) are multiplied by performance shaping factors (PSF) multiplier values to obtain the overall error probability. PSFs encompass the human components, individual characteristics, their environment, and aspects of the task. With PSFs, the goal is to capture all factors that can affect human performance. In SPAR-H there are eight PSFs used, each having respective levels corresponding to multipliers: Available Time, Stress/Stressors, Complexity, Experience/Training, Procedures, Ergonomics/Human Machine Interface, Fitness for Duty, and Work Processes. The PSF multipliers indicate enhanced, nominal, or degraded human performance. The SPAR-H method estimates the HEP through multiplying a NHEP with PSFs. Hence, SPAR-H is a traditional HRA method that assesses human performance at a fixed, or static, point in time. In a dynamic HRA framework, human performance is assessed on a continuous time basis. SPAR-H can be used within a dynamic PRA framework through the use of simulation and stochastic models. The goal of dynamic HRA is to build a more realistic model of the human-system interaction to enhance calculation of reliability, risk and safety analysis. The progression of events in dynamic SPAR-H considers that some PSFs may experience gradual change, while other change can be sudden due to individualistic differences or rapid plant status changes. The PSF changes are caused by contextual changes in the scenario. For example, as more time passes, the realization that a task should be completed sooner may cause the operator more stress. In another example, a sudden relay of information about sickness of a family member may alter the operator's general stress level and fitness for duty. Each PSF has a different dynamic nature; PSFs like stress and complexity change more quickly over the course of a task than experience and training. While the experience of an operator changes over the course of attaining the objective, the amount that this added experience changes the HEP is very minimal. In contrast, the stress, complexity, and procedures PSFs may change quite a bit over the course of task completion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Practical factors of envelope model setup and their effects on the performance of model predictive control for building heating, ventilating, and air conditioning systems

Model predictive control (MPC) for buildings is attracting significant attention in research and industry due to its potential to address a number of challenges facing the building industry, including energy cost reduction, grid integration, and occupant connectivity. However, the strategy has not yet been implemented at any scale, largely due to the significant effort required to configure and calibrate the model used in the MPC controller. While many studies have focused on methods to expedite model configuration and improve model accuracy, few have studied the impact a wide range of factors have on the accuracy of the resulting model. In addition, few have continued on to analyze these factors’ impact on MPC controller performance in terms of final operating costs. Therefore, this study first identifies the practical factors affecting model setup, specifically focusing on the thermal envelope. The seven that are identified are building design, model structure, model order, data set, data quality, identification algorithm and initial guesses, and software tool-chain. Then, through a large number of trials, it analyzes each factor's influence on model accuracy, focusing on grey-box models for a single zone building envelope. Finally, this study implements a subset of the models identified with these factor variations in heating, ventilating, and air conditioning MPC controllers, and tests them in simulation of a representative case that aims to optimally cool a single-zone building with time-varying electricity prices. It is found that a difference of up to 20%25 in cooling cost for the cases studied can occur between the best performing model and the worst performing model. The primary factors attributing to this were model structure and initial parameter guesses during parameter estimation of the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CHARMM-GUI Nanomaterial Modeler for Modeling and Simulation of Nanomaterial Systems

Molecular modeling and simulation are invaluable tools for nanoscience that predict mechanical, physicochemical, and thermodynamic properties of nanomaterials and provide molecular-level insight into underlying mechanisms. However, building nanomaterial-containing systems remains challenging due to the lack of reliable and integrated cyberinfrastructures. Here we present Nanomaterial Modeler in CHARMM-GUI, a web-based cyberinfrastructure that provides an automated process to generate various nanomaterial models, associated topologies, and configuration files to perform state-of- the-art molecular dynamics simulations using most simulation packages. The nanomaterial models are based on the interface force field, one of the most reliable force fields (FFs). The transferability of nanomaterial models among the simulation programs was assessed by single-point energy calculations, which yielded 0.01% relative absolute energy differences for various surface models and equilibrium nanoparticle shapes. Three widely used Lennard-Jones (LJ) cutoff methods are employed to evaluate the compatibility of nanomaterial models with respect to conventional biomolecular FFs: simple truncation at r = 12 Å (12 cutoff), force-based switching over 10 to 12 Å (10-12 fsw), and LJ particle mesh Ewald with no cutoff (LJPME). The FF parameters with these LJ cutoff methods are extensively validated by reproducing structural, interfacial, and mechanical properties. As a result, we find that the computed density and surface energies are in good agreement with reported experimental results, although the simulation results increase in the following order: 10-12 fsw <12 cutoff < LJPME. Nanomaterials in which LJ interactions are a major component show relatively higher deviations (up to 4% in density and 8% in surface energy differences) compared with the experiment. Nanomaterial Modeler's capability is also demonstrated by generating complex systems of nanomaterial-biomolecule and nanomaterial-polymer interfaces with a combination of existing CHARMM-GUI modules. We hope that Nanomaterial Modeler can be used to carry out innovative nanomaterial modeling and simulations to acquire insight into the structure, dynamics, and underlying mechanisms of complex nanomaterial-containing systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MODELING THE AMBIENT CONDITION EFFECTS OF AN AIR-COOLED NATURAL CIRCULATION SYSTEM

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). One such variant, air-cooled RCCS, uses natural convection to drive the flow of air from outside the reactor building to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a half-scale model of the primary features of one conceptual air-cooled RCCS design. The facility was constructed to carry out highly instrumented experiments to study the performance of the RCCS concept for reactor decay heat removal that relies on natural convection cooling. Parallel modeling and simulation efforts were performed to support the design, operation, and analysis of the natural convection system. Throughout the testing program, strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under the same test procedures. Thus, significant analysis efforts were devoted to gaining a better understanding of these influences and the subsequent response of the NSTF to ambient conditions. It was determined that air humidity had negligible impacts on NSTF system performance and therefore did not warrant consideration in the models. However, temperature differences between the building exterior and interior air, along with the outside wind speed, were shown to be dominant factors. Combining the stack and wind effects together, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions. Some coefficients in the model were obtained based on best fitting the experimental data. The predictive capability of the empirical model was demonstrated by applying it to the new set of experimental data. The empirical model was also implemented in the computational models of the NSTF using both RELAP5-3D and STARCCM+ codes. Accounting for the effects of ambient conditions, simulations from both codes predicted the natural circulation flow rates very well.

Hu, Rui↗

Evaluating Implementations of the Immersed Boundary Method in the Weather Research and Forecasting Model

The terrain-following coordinate system used by many atmospheric models can cause numerical instabilities due to discretization errors as resolved terrain slopes increase and the grid becomes highly skewed. The immersed boundary (IB) method, which does not require the grid to conform to the terrain, has been shown to alleviate these errors, and has been used successfully for high-resolution atmospheric simulations over steep terrain, including vertical building surfaces. Since many previous applications of IB methods to atmospheric models have used very fine grid resolution (5 m or less), the present study seeks to evaluate IB method performance over a range of grid resolutions and aspect ratios. Two classes of IB algorithms, velocity reconstruction and shear stress reconstruction, are tested within the common framework of the Weather Research and Forecasting (WRF) Model. Performance is evaluated in two test cases, one with flat terrain and the other with the topography of Askervein Hill, both under neutrally stratified conditions. WRF-IB results are compared to similarity theory, observations, and native WRF results. Despite sensitivity to the location at which the IB intersects the model grid, the velocity reconstruction IB method shows consistent performance when used with a hybrid RANS/LES surface scheme. The shear stress reconstruction IB method is not sensitive to the grid intersection, but is less consistent and near-surface velocity errors can occur at coarse resolutions. This study represents an initial investigation of IB method variability across grid resolutions in WRF. Future work will focus on improving IB method performance at intermediate to coarse resolutions.

54 ENVIRONMENTAL SCIENCES↗

Measurement of space charge effects in the MicroBooNE LArTPC using cosmic muons

Large liquid argon time projection chambers (LArTPCs), especially those operating near the surface, are susceptible to space charge effects. In the context of LArTPCs, the space charge effect is the build-up of slow-moving positive ions in the detector primarily due to ionization from cosmic rays, leading to a distortion of the electric field within the detector. This effect leads to a displacement in the reconstructed position of signal ionization electrons in LArTPC detectors ("spatial distortions"), as well as to variations in the amount of electron-ion recombination experienced by ionization throughout the volume of the TPC. We present techniques that can be used to measure and correct for space charge effects in large LArTPCs by making use of cosmic muons, including the use of track pairs to unambiguously pin down spatial distortions in three dimensions. Finally, the performance of these calibration techniques are studied using both Monte Carlo simulation and MicroBooNE data, utilizing a UV laser system as a means to estimate the systematic bias associated with the calibration methodology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cation–Ligand Interactions Dictate Salt Partitioning and Diffusivity in Ligand-Functionalized Polymer Membranes

Membranes are an attractive alternative to current thermal separations due to their scalability and energy efficiency in desalinating water. Unfortunately, many of the conventional membrane materials available today are unable to differentiate between ionic solutes, especially alkali cations, compromising their use in ion–ion separations. Inspired by the ion-specific interactions exhibited by biological ion channels, recent research efforts have focused on synthesizing and characterizing new polymeric materials that incorporate ligands into polymer networks to bias solubility and/or diffusivity of one cationic species over another. Despite these efforts, little is known about the influence of incorporating ligands into polymer membranes on solubility and diffusivity of the complexing species. In this study, we first build a qualitative model of salt partitioning, diffusivity, and permeability in generic cation-complexing ligand-functionalized polymer membranes. Next, to validate our model and hypotheses, we perform atomistic molecular dynamics simulations of a 12-crown-4-functionalized membrane in the presence of alkali halide salts at low concentration. Generally, cation complexation enhances cation solubility but decreases diffusivity. Interestingly, the reduction in diffusivity is predicted to be larger than the enhancement in solubility for materials which operate by the mechanisms proposed in our physical picture, ultimately resulting in a reduction in the permeability of the selectively complexing ion.

36 MATERIALS SCIENCE↗

Final Report on the Viability of Acoustic Techniques for Density and Mass Flow in Enrichment Plants

The primary purpose of this research is to study the viability of acoustic signatures and sensors that could support accurate, noninvasive, and unattended measurement of uranium hexafluoride (UF6) gas density and mass flow rate in situations representative of gaseous centrifuge enrichment plants (GCEP) under safeguards by the International Atomic Energy Agency. The measurement method under development can be readily retrofitted to the exterior of piping in existing systems, potentially facilitating acceptance by facility operators. The findings from the demonstration of a preliminary prototype design and first-generation analysis algorithms in this project will inform the safeguards community as to whether continued acoustic instrument and methods development are warranted. This project conducted two types of measurements, depending on the flow conditions of the gas. For static measurements, the focus is on understanding the acoustic properties at low pressure for non-flowing UF6. For flow measurements, the focus is on understanding the performance of the acoustic system in a simulation of a GCEP pipe using a surrogate gas under fully developed flow conditions. Testing with flowing UF6 was not considered because the cost of building a flowing UF6 system with flow similar to a GCEP was considerably greater than allocated project resources. This document summarizes the results of research conducted over the course of the project. Based on the results to date, the approach is seen to be promising with non-invasive acoustic measurements shown to be possible at the desired pressures. The project has demonstrated • 5% uncertainty of the UF6 gas density for static measurements at pressures relevant to GCEP operations over a 5-minute measurement window with a clear path forward to achieving considerably lower uncertainties over a two-hour period, • Measurements of flowing surrogate gases at pressures relevant to GCEP operations. However, additional research remains to be done to further develop the measurement approach and transition the technology for field use. These development needs include: • Understand the impact of flowing gas on gas density measurements, • Adding sensors and improving the measurement procedure, • Augmenting the data analysis methods by leveraging machine learning approaches, • Reevaluating uncertainty requirements for density and mass flow given observed Online Enrichment Monitor (OLEM) measurement uncertainties, • Designing a robust instrumentation package for field-testing, and • Evaluating measurement results to understand the potential impact on mass balance calculations within GCEP facilities.

42 ENGINEERING↗

City-Wide Distributed Roof-Top Photovoltaic System Adoption Forecast, Grid Impact Simulation, & Neighborhood Microgrid Contribution Assessment

The adoption of distributed photovoltaic (PV) systems grew significantly in recent years. Market projections anticipate future growth for both residential and commercial installations. To understand grid impacts associated with distributed PV, useful hosting capacity studies require accurate representations of the spatial distribution of PV adoptions. Prediction of PV locations and numbers depends on median income data, building use zoning maps, and permit records to understand existing trends and predict future adoption rates and locations throughout an entire city. Using the PV adoption data, advanced and realistic simulations were performed to capture the distributed PV impacts on the grid. Also, using graph theory community detection hundreds of neighborhood microgrids can be discovered for the entire city by identifying densely connected loads that are sparsely connected to other communities. Then, based on the PV adoption predictions, this work identified the contribution of PV within each of the newly discovered graph theory defined microgrid communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human-Building Collaboration: Toward lighting enabled collaborative system design

The profession of lighting design is evolving as contemporary lighting systems increasingly rely on cutting-edge computational technologies, sensors, and IOT systems. This trend requires designers to incorporate ideas of automation, dynamic controls, and user-system interaction into their design logic. However, real-time lighting simulations are constrained by inherent limitations arising from the reductive assumptions inevitably introduced in simulated lighting environments. This raises the question of how can designers account for the discrepancies between simulated and real lighting environments, and how can collaboration between humans and autonomous lighting systems bridge this gap. To address this question, we propose a protocol for designing collaborative interactions between humans and systems. Furthermore, this protocol builds on the Human-Lighting System Interaction Framework and demonstrates how human and system intelligence can be combined to fine-tune lighting qualities in a given space. Our paper shows how interactive lighting systems can customize lighting based on user preferences in real-time and how global lighting configurations can be adjusted over time. Specifically, we demonstrate: a) Human-system collaboration assumptions and goals, as well as how the protocol can be integrated into digitally programmable lighting systems. b) Implementations of collaboration that reveal how system autonomy, performance, and user experience are improved over short and long-term timeframes. c) How lighting design can be enhanced beyond simulation-driven design optimization capacities. The associated affordances and limitations are discussed with respect to existing lighting simulation design frameworks.

autonomous systems↗

Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States

Electrification of fossil-fuel combustion in buildings is a key component of achieving global greenhouse gas emissions targets. We use physics simulations of 550,000 statistically representative households to analyze distributions of the costs and benefits of three air-to-air heat pump performance levels, with and without insulation upgrades, across the diversity of the US housing stock. We find positive greenhouse gas reductions in every US state for all performance levels across five 2022-2038 electric grid scenarios, with full adoption reducing national emissions by 5%-9%. We find that air-to-air heat pumps could be cost effective without subsidies in 59% of households (65 million). However, efficiency is key: whereas minimum-efficiency equipment could increase energy bills in 39% of households, this fraction is only 19% when also upgrading insulation or 5% when using higher-efficiency equipment, though both strategies have higher upfront costs. Such affordability challenges could be addressed through supportive incentives, policy, and innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SHARP Assembly-Scale Multiphysics Demonstration Simulations

The NEAMS Reactor Product Line effort aims to develop an integrated multiphysics simulation capability for the design and analysis of future generations of nuclear power plants. The Reactor Product Line code suite’s multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. In this report, we describe our efforts to integrate thermal/hydraulics, neutronics, and structural mechanics modeling codes to perform coupled analysis of a representative fast sodium-cooled reactor fuel assembly. Over the past five years, the Reactor Product Line effort has developed high-fidelity single-physics codes for neutron transport modeling, in the PROTEUS code, and Large Eddy Simulation-based thermal/fluid modeling in the Nek5000 code. Both these codes have been exercised on over 100,000 processors of the IBM Blue Gene/P. The Diablo code has been used to perform structural mechanics and thermo-mechanical modeling. MOAB, the Reactor Geometry Generator (RGG), and MeshKit have been developed to generate and manipulate mesh and mesh-based data, in both serial and parallel environments. These tools together form a strong basis on which to build a multi-physics modeling capability. The goal of developing such a tool is to perform multi-physics neutronics, thermal/fluid, and structural mechanics modeling of the components inside a reactor core. While the focus of this report is on modeling a fast sodium-cooled reactor, it is also the goal that this simulation tool be useful for most reactor types. Here we report on the integration of PROTEUS and Nek5000 into the NEAMS framework. Both codes have been modified to read and write data from and to the MOAB library, in both serial and parallel environments. We focused on broad support for as many original physics code options as possible, rather than focusing only on near-term needs. Both codes were demonstrated through this interface on a relatively simple, seven-pin hexagonal fuel assembly. To support coupled analysis, the new multi-physics driver library COUPE was developed; this library provides flexible support for both loose and tight coupling, and can interface flexibly with codes in multiple programming languages. To couple results between the separate meshes used in each physics, the driver, PROTEUS, and Nek5000 all interface with the MBCoupler solution transfer tool provided with MOAB. Together, these tools form the basis of a new, coupled neutronics and thermal/fluid modeling code, that works in both serial and parallel. In a related effort, a driver in the Diablo code was used to access Nek5000-computed results written to a MOAB database, as well as the temperature data used to drive structural mechanics computations.

Tautges, Timothy J.↗