Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A compact linear accelerator based on a scalable microelectromechanical-system RF-structure

Here, a new approach for a compact radio-frequency (RF) accelerator structure is presented. The new accelerator architecture is based on the Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) structure that was first developed in the 1980s. The MEQALAC utilized RF resonators producing the accelerating fields and providing for higher beam currents through parallel beamlets focused using arrays of electrostatic quadrupoles (ESQs). While the early work obtained ESQs with lateral dimensions on the order of a few centimeters, using a printed circuit board (PCB), we reduce the characteristic dimension to the millimeter regime, while massively scaling up the potential number of parallel beamlets. Using Microelectromechanical systems scalable fabrication approaches, we are working on further red ucing the characteristic dimension to the sub-millimeter regime. The technology is based on RF-acceleration components and ESQs implemented in the PCB or silicon wafers where each beamlet passes through beam apertures in the wafer. The complete accelerator is then assembled by stacking these wafers. This approach has the potential for fast and inexpensive batch fabrication of the components and flexibility in system design for application specific beam energies and currents. For prototyping the accelerator architecture, the components have been fabricated using the PCB. In this paper, we present proof of concept results of the principal components using the PCB: RF acceleration and ESQ focusing. Finally, ongoing developments on implementing components in silicon and scaling of the accelerator technology to high currents and beam energies are discussed.

43 PARTICLE ACCELERATORS↗

A compact membrane-driven diamond anvil cell and cryostat system for nuclear resonant scattering at high pressure and low temperature

In order to study the vibrational and thermal dynamic properties of materials using the nuclear resonant inelastic X-ray scattering (NRIXS) and the hyperfine interactions and magnetic properties using the synchrotron Mössbauer spectroscopy (SMS) at simultaneously high pressure (multi-Mbar) and low temperature (T< 10 K), a new miniature panoramic diamond anvil cell (mini-pDAC) as well as a special gas membrane driven mechanism have been developed and implemented at 3ID, Advanced Photon Source. The gas membrane system allows in situ pressure tuning of the mini- pDAC at low temperature. The mini-pDAC fits into a specially designed compact liquid helium flow cryostat system to achieve low temperature, where liquid helium flows through the holder of the mini-pDAC to cool the sample more efficiently. The sample temperature as low as 9 K has been achieved. Through the membrane, the sample pressure as high as 1.4 Mbar has been generated from this mini-pDAC. The instrument has been routinely used at 3ID for NRIXS and SMS studies. In this paper, technical details of the mini-pDAC, membrane engaging mechanism and the cryostat system are described, and some experimental results are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source-to-accelerator quadrupole matching section for a compact linear accelerator

Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of two compact permanent magnet spectrometers for high current electron linear induction accelerators

In this work, two compact, permanent magnet, electron spectrometers have been built to measure the electron beam energy at the Dual Axis Radiographic Hydrodynamic Test facility. Using H - and OH - anions, the spectrometers were calibrated at the Special Technologies Laboratory in Santa Barbara, California (USA). The spectrometers were mounted on a custom drift tube that allows the magnet assemblies to be translated, which increases the path length of the electrons traveling through the magnetic field and therefore increases the upper bound of the measurable electron kinetic energy. The measurable range of electron kinetic energies is between 2.8 MeV–4.1 MeV for the first spectrometer and 14.1 MeV–21.1 MeV for the second spectrometer, with an overall measurement uncertainty of 0.32%.

47 OTHER INSTRUMENTATION↗

Demonstration of waferscale voltage amplifier and electrostatic quadrupole focusing array for compact linear accelerators

Compact linear accelerators, with beam energies in the kiloelectron volt to megaelectron volt range, have applications in medicine, neutron/X-ray generation, surface modifications, etc. The size, weight, and power of existing accelerators preclude them from mass availability in portable formats. This paper presents a specific implementation of an ion accelerator architecture based on planar wafers with accelerating and focusing sections. Our low cost approach allows the control of the final ion beam energy with potential applications, for example, for accelerator-based ion implantation. In this paper, we demonstrate two important waferscale modules required to build a linear particle accelerator; these include (1) on-wafer voltage amplification for beam acceleration using Inductor-Capacitor (LC) resonators and (2) waferscale electrostatic quadrupole arrays (ESQA) to refocus the ion beams during transport. On-board LC resonators were developed using Printed Circuit Board fabrication processes to implement an LC element resonant at ~ 16.6 MHz with a quality factor of 25. An energy gain of ~ 250 eV was observed using a two wafer acceleration unit with an argon ion beam with 6.5 keV initial energy. A 3 × 3 ESQA was fabricated on a glass wafer with metal electrodes formed by depositing copper metal around the beam apertures. The ESQA was used to focus and defocus an argon ion beam, demonstrating a field gradient of ~ 500 V over a gap of ~ 250 μm.

43 PARTICLE ACCELERATORS↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

A compact x-ray diffraction system for dynamic compression experiments on pulsed-power generators

Pulsed-power generators can produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies using the magnetic loading technique. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength–strain rate dependence, structural phase transitions, and density of crystal defects, such as dislocations. Here, we present a cost-effective, compact, pulsed x-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically driven ramp compression of materials with a single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials’ community to investigate in situ dynamic phase transitions critical to equation of states. Finally, we present results using this new diagnostic to evaluate lattice compression in Zr and Al and to capture signatures of phase transitions in CdS.

47 OTHER INSTRUMENTATION↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Developing compact tuning fork thermometers for sub-mK temperatures and high magnetic fields

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. Here, we present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3 He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.

47 OTHER INSTRUMENTATION↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

A Grad-Shafranov model for compact quasisymmetric stellarators

A Grad-Shafranov equation (GSE) valid for compact quasisymmetric stellarators is derived by an asymptotic expansion around a vacuum field carried to first order. We obtain an equation for the existence of flux surfaces leading up to the GSE. The flux surface label must simultaneously satisfy the existence equation and the GSE, which generally leads to an overdetermined problem. We show how the overdetermined problem can be resolved within our model for a class of hybrid devices similar to that studied by Henneberg and Plunk [Phys. Rev. Res. 6, L022052 (2024)]. We are also able to solve the existence equation for flux surfaces analytically in the most general case by introducing a special coordinate system. This will enable us to carry out an optimization seeking to minimize the error in our GSE while obeying the flux surface existence equation, which will allow us to find solutions outside the class of hybrid devices. This will allow for a coarse-grained approximate search in the space of quasisymmetric equilibria that should be faster than a conventional stellarator optimization. Nevertheless, it would still be necessary to fine-tune the approximate solutions using conventional tools to obtain a more precise optimized equilibrium.

Nikulsin, N. (ORCID:0000000318611777)↗

Benchmarking core turbulence and transport predictions for an inductive compact tokamak reactor plasma

Motivated by the need for accurate, timely, and efficient calculations of plasma transport, predictions of plasma turbulence properties made using different TGLF saturation rules are benchmarked against corresponding predictions from linear and nonlinear gyrokinetic CGYRO simulations. This benchmarking is carried out using parameters taken from an inductive burning plasma scenario in a hypothetical compact high-field (R maj = 4 m, B T = 8 T) tokamak, lying in a much different regime of parameter space than either the TGLF calibration regime or current-day experiments. The core turbulent transport in this scenario is predicted to be dominated by ion temperature gradient (ITG) turbulence. In general, the ITG critical gradients predicted by various TGLF saturation rules are quite close to the CGYRO predictions. Both codes predict similar linear ITG growth rates and frequency spectra, as well as their scaling with R/L T i = −Rd ln(T i )/dr. However, TGLF systematically predicts unstable trapped-electron modes (TEMs) above k y ρ s ≃ 0.5 not seen by CGYRO for the same parameters, due to TGLF predicting a lower threshold in R/L T e than CGYRO for TEM onset. It is shown that for this scenario, nonlinear CGYRO simulations predict stiffer ITG turbulence than the TGLF SAT0 and SAT1 saturation rules, with energy fluxes close in magnitude and scaling with R/L T i to what is predicted by the SAT2 saturation rule. Self-consistent core profiles calculated using nonlinear CGYRO flux predictions and the PORTALS transport solver are shown to agree fairly well with corresponding predictions made using the TGLF SAT2 model, including a similar level of density peaking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗